Administrative Officer Purchase
IUCAA, Pune
Supply and installation of Air Condition
2022_IUCAA_699692_1
M22-0307
Limited
Electrical Goods/Equipment
Supply
30 days
IUCAA
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
19 Jul 2022
8 Jul 2022
19 Jul 2022
8 Jul 2022
18 Jul 2022
8 Jul 2022
8 Jul 2022 - 12 Jul 2022
Amount
Supply, Installation, Testing and commissioning of Hiwall Split AC Units with all inverter compressor consisting of - (1) Condensing unit with reputed make hermetically sealed DC Twin/Swing Rotary inverter compressor, air cooled condenser with copper Tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. (2) Indoor unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. (3) The minimum acceptable value of Coefficient of Performance (COP) of the offered Split AC model shall be not less than 3.85 for 1.5 TR on 100% (5.0 Kw) and and 3.90 for 1.8/2 TR (6 Kw) Hiwall Split AC at rated Capacity with 35 deg. C outdoor and 19 deg. C wet bulb conditions. The COP confirmation should be done by the OEM on their authentic letter head. (4) The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. (5) Necessary charge of oil and refrigerant gas as required up to handling over & defects liability period of the system. (6) Interconnecting piping between evaporator and condensing units as per site requirement insulated suction line & liquid line for all the circuits of one machine. The suction lines shall be insulated with closed cell Nitrile rubber tube insulation. (7) The units shall be with individual cordless remote. (8) The units shall be suitable for operation on 220/240 Volts, 1 ph., 50 Hz, 3 wire A.C. supply. 1.8/2 TR capacity (6 Kw & above cooling capacity) - 5 Star, Inverter Hiwall Split AC Unit
Supply, Installation, Testing and commissioning of Hiwall Split AC Units with all inverter compressor consisting of - (1) Condensing unit with reputed make hermetically sealed DC Twin/Swing Rotary inverter compressor, air cooled condenser with copper Tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. (2) Indoor unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. (3) The minimum acceptable value of Coefficient of Performance (COP) of the offered Split AC model shall be not less than 3.85 for 1.5 TR on 100% (5.0 Kw) and and 3.90 for 1.8/2 TR (6 Kw) Hiwall Split AC at rated Capacity with 35 deg. C outdoor and 19 deg. C wet bulb conditions. The COP confirmation should be done by the OEM on their authentic letter head. (4) The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. (5) Necessary charge of oil and refrigerant gas as required up to handling over & defects liability period of the system. (6) Interconnecting piping between evaporator and condensing units as per site requirement insulated suction line & liquid line for all the circuits of one machine. The suction lines shall be insulated with closed cell Nitrile rubber tube insulation. (7) The units shall be with individual cordless remote. (8) The units shall be suitable for operation on 220/240 Volts, 1 ph., 50 Hz, 3 wire A.C. supply. 1.5 TR capacity (5 Kw cooling capacity) - 5 Star, Inverter Hiwall Split AC Unit
Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation 5/8" & 3/8" or 1/2" & 1/4" /Suitable for above machines
Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation Drain piping in hard CPVC with all fittings, supports and clamps upto 50 mm dia. including drilling hole in wall chipping wall etc to conceal and to route drain pipe.
Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation Set of Power & Control Cabling complete for all circuits of machine with insulation and conduiting complete with supporting arrangement etc. for Hiwall Split AC.
Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation MS structural work and special supporting structure for condensing units, Powder Coated
Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation Core cutting in wall/slab for AC piping (pleaser refer tender document for details).
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .