Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr | L1 | Accepted-AOC Tender accepted being L1 |
| 2 | L2₹3.9 Cr+₹32.5 L (9.13%)Rejected-Finance GURDWARA LINE SHOWROOM NO 6 DESHMESH MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹3.9 Cr+₹32.5 L (9.13%) | L2 | Rejected-Finance Not accepted being other than lowest |
Tender Value
₹3.3 Cr
EMD Value
₹4.0 L
Closing Date
23 Feb 2025, 6:30 pmClosed
CE A and N Zone
Headquarters Chief Engineer Andaman and Nicobar Zone Military Engineer Services Birchgunj Junglighat Post Sri Vijaya Puram - 744 103
PROVISIONING OF INFRASTRUCTURE AND ALLIED FACILITIES TOWARDS INSTALLATION AND COMMISIONING OF RADAR AT CAMPBELL BAY
2024_MES_679033_3
8012272R/E8
Open Tender
Civil Works
Lump-sum
650 days
Campbell Bay
As per NIT
8 documents required · 8 mandatory
₹2,000
GE (I) Campbell Bay
₹4.0 L
Yes
28 Mar 2025
21 Jan 2025
26 Feb 2025
21 Jan 2025
23 Feb 2025
4 Feb 2025
Amount
NOTE: Schedule ‘A’ Part-I is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
Design and construction of Steel lattice tower of height 40mts with flat base min area of 4 x 4 m on top to withstand a load of 1200 kgs with ground floor enclosed room of min size 4 x 4m with height 4m at ground level and Equipment room enclosed of min 4 x 4 mtr with 4m height at a height of 30 mtr from the ground level with hosting pulley arrangement for lifting 500 kgs load to top for mounting radar and pedestal on top and staircase suitably for seismic zone V and considering the coastal area & its heavy wind effect including foundation of tower with including structural design & drawing complete.
Design and construction of DG Shed of RCC framed structure construction, PCC Block Masonry, Aluminium windows & frames, steel rolling shutter including all fittings and fixtures complete all as shown on drawings as specified and as directed, with design & including structural drawings etc complete.
Note for item No 2 & 3 : The Contractor shall submit the following:- (a) All structural drawing and Steel Tower drawing including the details of all structural members, junction details required if any expansion joints for execution of work. (b) Design calculations, STAAD file and drawing duly vetted by any of the IIT/IISc Bangalore /SERC/NIT/Govt Engineering Colleges. (c) Certificate from above vetting agency that the design is meeting relevant codal requirement (d) Details of Quantities of: (i) Steel reinforcement & Structural Steel (section wise) (ii) RCC (Grade and location wise) (iii) Design parameter shall be followed as mentioned under relevant para of PS hereinafter. The rate includes the provisions of the following :- (i) Necessary foundation for structures as mentioned above shall be followed as per Sch 'A' notes. (ii) Necessary excavtion for the foundation. (iii) All types of joinery, building hardware and other items which are essential and required to complete the building in all respect as specified (iii) Any items which are essential and required to complete the structure as specified herein-before and not found mentioned hereinbefore/after shall be deemed to be included in quoted rate and as per sound engineering practices and IS codal provisions to complete the work in all respect. Nothing extra whatsoever shall be admissible. Decision of the Accepting Officer, shall be final, conclusive and binding.
GENERAL SUMMARY NOTE: Schedule ‘A’ Part - II to IX are prepriced by MES under Ser No. 6.00 to 13.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “EXCAVATION & EARTHWORK INCLUDING SITE CLEARANCE AND LAND DEVELOPMENT” as listed in Schedule ‘A’ Part - II , inserted by MES.
Lumpsum price worked out by the tenderer for "INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part-III, inserted by MES.
Lumpsum price worked out by the tenderer for "ROAD / PATH / CULVERT/HARD STANDING" as listed in Schedule ‘A’ Part- IV, inserted by MES.
Lumpsum price worked out by the tenderer for "AREA DRAINAGE " as listed in Schedule ‘A’ Part- V, inserted by MES.
Lumpsum price worked out by the tenderer for "FENCING AND GATE" as listed in Schedule ‘A’ Part- VI, inserted by MES.
Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIC SUPPLY " as listed in Schedule ‘A’ Part- VII, inserted by MES.
Lumpsum price worked out by the tenderer for "AIR CONDITIONING" as listed in Schedule ‘A’ Part- VIII, inserted by MES.
Lumpsum price worked out by the tenderer for "FIRE DETECTION AND ALARM SYSTEM" as listed in Schedule ‘A’ Part- IX, inserted by MES.
Subtotal
NOTE: Schedule ‘A’ Part - X (miscellaneous) are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
FENCING AND GATE Supply only PVC coated chain link fencing of mesh size 50x50mm & made out of 3mm GI wire with 1mm thick PVC coating incl transportation to site complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY Design, fabrication, supply and erecting connecting and testing totally enclosed LT cubical panel board of suitable size (proper space shall be provided for working in each compartment ),3 Phases 4 wire system outdoor type 3.15mm, double door front and back opening types, separate compartment of each control gear, cable alley, provision of knock out type plates for various sizes of cable 3.5 Core in and out, incoming and outgoing feeders duly marked on revited plates etc. CPRI approved factory made fabricated out of 3.15mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade color, built in industrial type locking arrangement on front and back and pre wired with PVC sleeved aluminium strip for connecting MCCBs,panel mounted on suitable size & thickness of angle iron frame (proper mounting shall be done)duly painted and embedded in necessary required quantity of PCC 1:3:6 type C1, 30 cm below the ground level and 30 cm above ground level and consisting the following provisions:- (a) Onload change over 4 pole 100 Amps,36 KA-01 Nos(Incoming) (b) MCCB 4 pole 100 Amps adj type 36KA-01 Nos(Incoming) (c) MCCB 3 pole 40-63 Amps , 25KA-03 Nos (outgoing-02+01 spare) (d) MCB 3 pole 25-63 Amps,10 KA -02 Nos(Outgoing-01+01 spare) (d) Aluminium Busbar 200 Amps with sleeves-04 (three phase with natural and connector set of 4)
M&L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Supply and fix time switches 3P Module, 24 hours program, Programmable every 15 min., backup of TA926453 3934 100 hrs., current capacity 16A, with 1 changeover (1 CO) 250V, with conductor fitted inside steel encloser all as specified and as directed.
Supply and fixing PVC junction box of size 200mm X 140mm X 95 mm, light weight pole mounting hinged type mounting of box on pole with MS flat frame arrangement and necessary connector for looping in and looping out cables connection and suitable glands complete.
Material & Labour for supply, installation, testing and commissioning of copper pipe electrode earthing maintenance free earthing based on 3 mtr long copper pipe 18mm dia (ID) with wall thickness of 2mm, copper strip in pipe and filled with MFC for improvement of conductivity of electrode duly fixed with connector at top connection of copper strip 25 x 3mm riveted/ nut bolt after 12mm boring and further earth continuity conductor made of copper strip 25 x 3 mm upto 7.5m., 60 Kg BFC shall be filled around the copper pipe electrode, including providing FRP pit cover of size 250mm x 250mm x 250mm complete as per manufacturer specification and complete all as specified and directed by Engr-in-Charge. (Item include a set of 3 Nos Earthing) Note:- (i) Rate included for testing, commissioning including checking of earth continuity and earth result complete all as specified and directed. (ii) Vendors are bound to get earthing result upto 1 Ohm with grid of three earthings, Any additional work and material required to achieve the required result is included in the cost. (iii) Earth strip beyond 7.5 m shall be measured and paid separately. (iv) Earth work is deemed to be included in the quoted rate. (v)Set of three jobs shall be measured & paid as one unit rate ,rates quoted deemed to be included in unit cost.
S&F for HDPE double door corrugated pipes conforming to IS-14930 Part-II IP protection of IP-67 having outer dia 120mm and inner dia of 103mm with necessary couplers bends etc for protection of LT UG cable all as specified and directed.
M&L LED Aviation Obstruction light with Neon lamp having temperature range from -10 to +60 and voltage range from 12 to 24 V including necessary wiring as required to operate the aviation light from nearest point all as specified and as directed.
AIR CONDITIONING Supply and install testing and commissioning Voltage Stabilizer for automatic correction and operation single phase neutral air cooled split type and designed for input various between 170 to 250 V with output stabilizer at 230V with necessary +/- 2.5% and of capacity 5 KVA complete.
M&L LCD display ,micro controlled Digital time switches comprising of supply voltage 110-240Volts, 50Hz, Power consumption max 6VA,minimum switching time 1 min,with current rating 16Amps,switching modes shall have Auto program run, Instant on up to next auto event ,instant off up to next auto event, continuous on, continuous off & shall have LED indications & all necessary wiring, connections loop in/out from split ac to AC metal clad box & this timer shall be house adequate size of PVC enclouser complete all as directed by Engr-in-Charge. Make: GIC cat no. 67DDT0(Crono) or its eqlt in Siemens/ABB/Schenieder
ELECTRICAL WINCH Supply, install, testing& commissioning of 1000kg tower hoist with 40m working height structure of capacity 1000 kg, heavy electric winch powered by 10HP electric geared motors complete all as directed. Mast : Made up of High tensile structure steel square 500X400mm , 1.5m height, High tensile bolts, Nut, washers, 50X50x6mm thick MS Angle. Anchorage complete with base plates, adjusting bolts Anchor fasteners and provided at every 6m Bucket & carrier : Bucket made up of 3.015mm thick, MS sheet capacity 750kg carrier is made up of high tensile structure steel, complete with 8 numbers hardened guide rollers with boaring for carrying high load and jerk free smooth travel operation and anti falling safety hooks Winch : Heavy duty electric winch capacity 1000kg powered by 10Hp electric geared motor with braking arrangements Speed:20-25 meter per minute Control Panel : Electric control panel, complete with remote is provided for working of tower hoist control panel is protected by overload relays, phase preventor and voltage fluctuations Safety features Bottom limit switch Anti-falling safety hooks Shockers Wire rope 6 X 19 construction Electric Control panel with protection relays, phase preventor from voltage fluctuations Foundation: Main frame fabricated from 100 x 50 ISMC complete with holes for foundation bolts/Anchor fasteners
Subtotal
SALCON ENGINEERS AND FABRICATORS (BID ID -3236675)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .