Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC H NO 1 7 1 79 1 ROAD NO 7 REDDY ENCLAVE TEMPLE ALWAL SECUNDERABAD 500 010 | HYDERABAD | TELANGANA | 500010 | L1 | Accepted-AOC FOUND LOWEST | |
| 2 | L2₹28.7 L+₹67,109 (2.39%)Rejected-AOC 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹29.5 L+₹1.4 L (4.95%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹29.7 L+₹1.6 L (5.66%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹30.2 L+₹2.2 L (7.74%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
26 Jan 2022, 6:00 pmClosed
SHRI MAHAVIR SINGH, IDSE, GE (SOUTH)
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABD
SPECIAL REPAIRS TO WATER PROOFING TREATMENT TO ROOF OF BUILDING NOS P-12, P-13, T-30 AND P-226 OF 554 ASC BN AND SPECIAL REPAIR TO ROOF TREATMENT IN PAO (ORS) AOC BUILDING UNDER GE (SOUTH) SECUNDERABAD
2021_MES_498402_1
GE (S)/SEC/TOKEN - 47 OF 2021 - 22
Open Tender
Civil Works
Item Rate
240 days
Secunderabad
For Enlisted contractors class D and above category a (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹87,000
Yes
8 Mar 2022
30 Dec 2021
28 Jan 2022
30 Dec 2021
26 Jan 2022
13 Jan 2022
31 Dec 2021 - 12 Jan 2022
Amount
Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof incl tarfelt etc complete all as specified and as directed.
M&L for 40mm thick plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in padding (level course) on roof including finishing cement concrete surfaces even & fair complete all as specified and as directed.
M&L for rendering 10 mm thick in CM (1:3) using water proofing compound as per manufacturer instruction as in roof and chajjas including finishingcement concrete surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. (Note : Water proofing compound will be measured and paid separately).
Matrial & labour for water proofing treatment with APP based standerd membrane over PCC padding of roof with the following courses of treatment :- (a) Applying of bituminous primer @0.40 Ltr/Sqm as per IS-3384 including cleaning the surfaces complete all as specified and directed (b) Applying of 3mm thick APP plastomeric bitumen based mineral finished water proofing membrane,polyster reinforced (3.50/Sqm) with 10cm overlaps and tourch bounded at joints including surface preparation before and after application of treatment as per manufacturers instructions complete all as specified and directed.
Supply only water proofing compound complete all as specified and as directed.
S & F steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls,(concealed) 15mm bore.including taking down old pipe complete all as specified and as directed.
S & F steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls, 20mm bore.including taking down old pipe complete all as specified and as directed.
Demolition and breaking up drain AC pipes/PVC pipe set in cement mortar of any size complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 110mm complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 75mm complete all as specified and as directed.
S&F in repair PVC (SWR) bends 110mm all as specified and as directed.
S&F in repair PVC (SWR) bends 75mm all as specified and as directed.
Disconnecting existing PVC water tanks exc 250 & n exc 500ltrs setting a side (or loweringif required) for repairs , cleaning etc., and hoisting if required reconnecting and re-fixing in position (cleaning repairing etc., measured separetely)
Disconnecting existing PVC water tanks exc 500 & n exc 1000ltrs setting a side (or loweringif required) for repairs , cleaning etc., and hoisting if required reconnecting and re-fixing in position (cleaning repairing etc., measured separetely)
S&F 500 Ltrs capacity rotational moulded polythelene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball brass valve high pressure with polythene float and fly nut complete all as specified and directed.
S&F 1000 Ltrs capacity rotational moulded polythelene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball brass valve high pressure with polythene float and fly nut complete all as specified and directed.
Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick works in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or cement concrete surfaces in cement mortar 1:4, finished fair and even without using extra cement incl mixing of water proofing compound complete all as specified. (Note: Water Proofing compound shall be measured and paid for separately)
M&L for applying two coats of oil bound distemper over a coat of primer with 3mm thick wall care putty including prepartion of new surfaces on walls complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over a coat of primer with 3mm thick wall care putty including prepartion of new ceiling surfaces complete all as specified and as directed.
M&L for applying two coats of cement base paint on new plastered surfaces of wall including preparation of surfaces over a coat of priming paint complete all as specified & directed
M & L for applying One coat of Oil bound Distemper on Old wall surfaces including preparation of surfaces complete all as specified and directed.
M & L for applying One coat of OBD on Old ceiling surfaces including preparation of surfaces complete all as specified and directed.
M&L for applying one coat of cement base paint on old plastered surfaces of wall including preparation of surfaces complete all as specified & directed
M&L for applying three costs of white wash on new plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
M&L for applying three coats of white wash on new plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets complete all as specified and as directed.
M&L for providing false ceiling with anodised aluminium snap grid frame work with size of grid 605 x 605 mm with aluminium main tee size 25 x25 x1.60mm thick and, cross T section of size 25 x 25 x 1.60mm thick and wall angle of size 25x25x2mm thick fixed to roof with rawl plugs/GI wire suspenders complete all as specified and directed.
M & L 4 mm thick Non-Asbestos Cement Plain ceiling boards, fixed to timber/ Aluminium frame work with screws in ceilings and applying two coats of OBD over a coat of primer including preparation complete all as sepcified and directed.
M&L for crack filling with approved crack filler to arrest seepage and running water through masonry / RCC surfaces etc., complete all as specified . Make: Dr Fixit Leak Plug or its equivalent.
M&L for preparation of plastered surfaces and applying two coats of water proof coating (Dr. Fixit Rain coat exterior water proof coating) over a coat of primer (Dr. Fixit prime seal diluated with potable water by volume in 2:1 ratio 2 parts primer and 01 part water ) including filling of cracks upto 5mm width with Dr.Fixt Crack-X or Dr.Fixit unifiller on external surfaces of wall to arrest the seepage / dampness and running water in the masonry surfaces complete all as specified and as directed. Make: Dr. Fixit or its equivalent.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M & L Non skid caramic coloured tile 7 to 8 mm thick (square/ rectangular ) area of eachtile exceeding .11 sqm but not exceeding .18 sqm in floor laid over 15mm thick screed bed in CM 1:6etc set and jointed in neat cement slurry and pointed in white or colour to match complete all as specified and directed.
M & L for10mm thick Vitrified ceramic tiles light shade (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed or bedding in layer of CM 1:6 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregate as in base of water tank on roof surface complete all as specified and as directed.
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3.complete all as specified and as directed.
M&L PCC1:2:4 using B0 (using12.50mm graded aggregate) for coping, corner of roof and similar work complete all as sepcified and directed.
S&F in repairs rotational moulded polyethylene water storage tanks 2000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I including dismantling of existing damaged water tanks.complete all as specified and as directed.
S&F in repair rotational moulded polyethylene water storage tanks 1000 ltrs(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I including dismantling of existing damaged water tanks.complete all as specified and as directed.
S&F PTMT ball valves 20 mm dia high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes and fixed to iron pipes.complete all as specified and as directed.
S&F in repairs Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore complete all as specified and directed.
M&L for uprooting of wild trees such as grass/bushes etc from the roof/wall surface/AC sheets/soil pipes surrounding including its penetrated roots with suitable cleaning chemical and making good to the damaged plaster by providing CM 1:3 and finish the surfaces to match with the existing surface complete all as specified and as directed.
ATUL ENTERPRISES
NARAYANA CONSTRUCTIONS
BEEGEE DESIGN SYSTEMS
M/S DIVIJA BUILDERS
LAKSHMI ENGINEERS
SAMBASIVA RAO
K LAKSHMAN SINGH AND CO
VENKATA PRABHAVATHI CONSTRUCTIONS
Saiansh Associates
MVS ENTERPRISES
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .