Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹13.8 L+₹99,992.50 (7.81%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Higher than L1 Bidder | |
| 3 | L3₹13.9 L+₹1.1 L (8.79%)Rejected-Finance | L3 | Rejected-Finance Higher than L1 Bidder | |
| 4 | L4₹14.1 L+₹1.3 L (10.5%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L4 | Rejected-Finance Higher than L1 Bidder | |
| 5 | L5₹14.3 L+₹1.5 L (12.0%)Rejected-Finance | L5 | Rejected-Finance Higher than L1 Bidder |
Tender Value
₹12.2 L
EMD Value
₹24,400
Closing Date
25 Nov 2019, 6:00 pmClosed
MAJ VAIBHAV UPASNI
GE 872 EWS, C/O 99 APO
REPAIRS/MAINT OF INTERNAL ELECTRIC SERVICES, REPAIRS/ MAINT AND SERVICING TO VARIOUS TYPES OF FANS AND GEYSER, REPAIRS TO LT EXTERNAL ELECTRICAL INSTALLATIONS AND REPAIRS/ MAINT OF EXTERNAL WATER SUPPLY AT NLP MIL STN UNDER GE 872 EWS(8722/E8)
2019_MES_292735_1
C/8722/T-22/E8
Open Tender
Civil Works
Works
243 days
NLP
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹24,400
Yes
20 Jan 2020
25 Oct 2019
26 Nov 2019
25 Oct 2019
25 Nov 2019
11 Nov 2019
25 Oct 2019 - 30 Oct 2019
Amount
REPAIRS/MAINT TO INTERNAL ELECTRIFICATION
M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings, etc., Making Good disturbed surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE FAN POINT controlled by One 1-way Switch 6 Amp/Fan Regulator, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET 6 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. for ONE 3/5 PIN SOCKET 6 AMP POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3 PIN SOCKET OUTLET 16 AMP POINT on INDEPENDENT BOARD, complete all as specified and all as directed.
S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Casing Capping (ISI Marked) of size 32mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed
S&F PVC Rectangular Block of size 175x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F PVC Rectangular Block of size 200x150x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F Switch Piano Flush type, 6 Amp, Single Pole, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Piano Flush type, 6 Amp, Single Pole, 1-way, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Piano, complete all as specified and as directed.
S&F Switch Socket Outlet 3 Pin, 6 Amp, Flush type and connecting up, complete all as specified and as directed.
S&F Switch Socket Outlet 5 Pin, 6 Amp, Multi-Plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 5 Pin, 6 Amp, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Switch Socket combination 5 Pin, 6/16 Amp, Multi-Plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket combination 5 Pin, 16 Amp, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Pendant Holder Ordinary with Insulated Body Lamp Holder and connecting up, complete all as specified and as directed.
S&F Ceiling Rose Surface type, Bakelite 65x50mm 2 to 3 Terminal suitable for 230 Volt AC, 6 Amp and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Rotary Stepped Electronic type 120/280 Volt including necessary Connection and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Rotary Stepped Electronic type 120/280 Volt and connecting up including Taking down/ out unserviceable Fan Regulator, complete all as specified and as directed.
S&F LED Bulb 10 Watt suitable for fixing in Normal Pendent/Batten Holder, 230 Volt including Taking down/ out unserviceable Bulb, complete all as specified and as directed. MAKE : HAVELLS
S&F LED Batten 18 Watt 4 Feet Cool Day Light including Taking down/ out unserviceable Batten, complete all as specified and as directed. MAKE : CROMPTON/ HAVELLS/ PHILIPS/ WIPRO
S&F Flouroscent Tube Light Rod 36/40 Watt suitable 4 Feet long Tube Light Fittings including Taking down/ out unserviceable Tube Rod, complete all as specified and as directed. MAKE : BAJAJ/ HAVELLS/ WIPRO
S&F Electronic Ballast High Performance (THD 10%) 1x36 Watt and connecting up including Taking down/ out unserviceable Ballast, complete all as specified and as directed. MAKE : BAJAJ/ HAVELLS/ PHILIPS
S&F MCB Single Pole 6 to 32 Amp, 'C' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB Single Pole 40 to 63 Amp, 'C' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB Distribution Board, SPN 2-way, 240 Volt AC, Double Door type of Steel Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. MAKE : HAVELLS or equivalent Model of LEGRAND/ L&T
S&F MCB Distribution Board, SPN 4-way, 240 Volt AC, Double Door type of Steel Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. MAKE : HAVELLS or equivalent Modal of LEGRAND/ L&T
REPAIRS/MAINT OF FANS
M&L Taking down unserviceable Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Air Circulator Fan of any Make & Size after disconnecting and removing to AGE E/M Store Yard for Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Re-hanging the same in Original Position after repaired and providing Electric Connection, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involved to make the Fan completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Rewinding & Other Parts required to be replaced will be Measured and Paid separately as "S&F"/"M&L" under relevant Items.
S&F Condenser 2.5 mfd suitable for Ceiling Fan & Wall Mounted Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed.
S&F Condenser 4.0 mfd suitable for Exhaust Fan/ Air Circulator Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed.
S&F Ball Bearing (size as per existing one/ as approved) suitable for Ceiling Fan 1200/1400mm Sweep including Taking down/out unserviceable Ball Bearing, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
S&F Gun Metal Bush (size as per existing one/ as approved) suitable for Ceiling Fan of any Make and Size including Taking down/out unserviceable Bush, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
S&F Rubber Bush (Reel type) standard size and type duly fixed with suitable size Mild Steel Bolt, Nuts, etc. including Taking down/out unserviceable Rubber Bush, complete all as specified and as directed.
S&F Mild Steel Down Rod 15mm nominal dia and 250mm to 450mm long, heavy duty, duly painted in matching Colour of Fan, necessary drilling, etc. for hanging of Ceiling Fan including Taking down/out unserviceable Down Rod, complete all as specified and as directed.
S&F Oscilating Mechanism suitable for Wall Fan 400mm Sweep including Taking down/out unserviceable Oscilating Mechanism, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1200mm Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1400mm Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Exhaust Fan 250/ 300/ 350mm Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Wall/ Cabin Fan 400mm Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
S&F PVC Stranded Copper Conductor Flexible Cable 1.5 Sqmm 3 Core for Electric Connection including Taking down unserviceable Cable, complete all as specified and as directed.
M&L Taking down Ceiling Fan of any Sweep from any Situation after disconnecting, Preparing old Painted Surfaces of Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, Re-hanging the Fan in Original Postion & Re-connecting and Testing, complete all as specified and as directed.
REPAIRS/MAINT OF GEYSERS
M&L Taking down/Lowering unserviceable Water Heater of any capacity, any Make and type from any Height by disconnecting all Water and Electric Connections, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Repairing/ Replacing of unserviceable Accessories, removing all rusted Nuts, Bolts, de-scaling Inner Tank & Inter Connection Assembly, cleaning thoroughly with diluted Acid, Brazing/Gas welding of Inter Connection Assembly, checking of Inner Tank to make Fully Leakeage Proof and Testing the same with Water Filling/Air Pressure, Re-fixing/ Re-mounting the same in Original Position and providing necessary Water/Electric Connection and Testing on Completion, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Water Heater (Geyser) completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Parts required to be replaced will be Measured and Paid separately as "S&F" under relevant Items and Quantities are Provisional.
S&F Heating Element 1.5 KW 230 Volt suitable for Water Heater (Geyser) of any capacity, any Make including Taking down/out unserviceable Heating Element, complete all as specified and as directed.
S&F Heating Element 2.0 KW 230 Volt suitable for Water Heater (Geyser) of any capacity, any Make including Taking down/out unserviceable Heating Element, complete all as specified and as directed.
S&F Indication Lamp Rounded type 230 Volt suitable for Water Heater (Geyser) of any capacity, any Make including Taking down/out unserviceable Indication Lamp, complete all as specified and as directed.
S&F Pressure Release Valve Dead Weight type suitable for Water Heater (Geyser) of any capacity, any Make including Taking down/out unserviceable Pressure Release Valve, complete all as specified and as directed.
S&F Thermostate Switch with Thermal Setting 40 °C to 90 °C capacity and Relay 230 Volt including Taking down/out unserviceable Pressure Release Valve, complete all as specified and as directed.
M&L Repairs to Water Heater of any capacity and type by Taking out Unserviceable Water Tank (Inner Shell), brazing to leaking Portion or Patching Work as required with using Copper Plate 1.5mm thick including shaping to Original size, complete all as specified and as directed.
S&F PVC Pipe 15mm bore (dia), heavy duty for Inlet and Outlet Connections suitable for Water Heater (Geyser) including Taking down/out unserviceable PVC Pipe, complete all as specified and as directed.
S&F PVC Connection 15mm bore (dia) of length 450mm with PTMT Nuts suitable for Cold/Hot Water including Taking down/out unserviceable PVC Connection, complete all as specified and as directed.
REPAIRS TO LT EXTERNAL ELECTRICAL INSTALLATIONS
Dismantling unserviceable Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
Taking down ACSR Conductor including Line Spacers of OH Electric Lines from LT Electric Poles of any size and capacity, complete all as specified and as directed.
Dismantling LT Stay Assembly complete of any description, complete all as specified and as directed.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc., complete all as specified and as directed. NOTE : Necessary Earth Work will be Measured and Paid under appropriate Items.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Mete for Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removal Excavated Materials (Soil) to a distance not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed.
S&F Pin type Insulator 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed.
S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 150mm High and 150mm dia including Galvanised Mild Steel Straps of Section 38x5mm, 20mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 11000 Volt including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed.
S&F Insulator Loop type, Small in size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed.
S&F ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Size of Conductor will be as per Site requirement as directed by Engineer-in-Charge.
M&L Restretching, Tightening & Fixing of ACSR Conductor of any size on LT Electric Poles including necessary Aluminium Binding Wire including Refixing of Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed.
S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 2/3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
M&L Trimming/Cutting of Tree Branches of any girth/size and Clearing of OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 3.0 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed.
M&L Painting LT Electric Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with the Strips 300mm high around the Pole with Two different Colours Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp 7/3.15 Mild Steel Galvanised Stay Wire, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 65x90mm and Clearance of Hole 16mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles, 16mm dia Mild Steel Galvanised Stay Rod and Mild Steel Galvanised Stay Plate all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.
S&F Air Breaks Gang Operating Switch 11 KV, Triple Pole with DO Mechanically Vertical Operated, mounted on Insulator and Steel Frame with operating mechanism worked from Ground Level for current rating up to 200 Amp including Taking down unserviceable GOD, complete all as specified and as directed.
S&F LED Street Light 45 Watt made up of Pressure Die-cast, Housing with Toughned Glass and Individual High Power LEDs having Secondary Optics, IP-66 Protection and Impact Resistance of IK-07 complete with all Acessories and connecting up, fixing on existing Bracket mounted on Steel Tubular Poles including Taking down unserviceable Light Fitting from Electric Pole, complete all as specified and as directed. MAKE : HAVELLS, Cat No. LHETAXU7PN6JO45 or equivanent Model of BAJAJ/ PHILIPS/ SYSKA LED
S&F Electronic Ballast Low Harmonics (THD<10%) and fixing on existing Light Fitting T5, 4x14 Watt of MAKE : HAVELLS and connecting up including Taking down/out unserviceable Ballast, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt, 30 Watt and Output Voltage and fixing on existing LED Light Fitting 30 Watt of MAKE : HAVELLS and connecting up including Taking down/out unserviceable Driver, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt, 45 Watt and Output Voltage and fixing on existing LED Light Fitting 45 Watt of MAKE : HAVELLS and connecting up including Taking down/out unserviceable Driver, complete all as specified and as directed.
Supply & Laying or Fixing to/ Passing through Pipe, 1100 Volt grade heavy duty Cable with PVC insulated Aluminium Conductor served with an inner sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed, Cross-sectional area 4.0 Sqmm, 2 Core as Service Connection Cable and connecting up including Taking down/out unserviceable Cable from any Situation, complete all as specified and as directed.
Supply & Laying or Fixing to/ Passing through Pipe, 1100 Volt grade heavy duty Cable with PVC insulated Aluminium Conductor served with an inner sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed, Cross-sectional area 6.0 Sqmm, 2 Core as Service Connection Cable and connecting up including Taking down/out unserviceable Cable from any Situation, complete all as specified and as directed.
Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 16 Sqmm, 4 Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 25 Sqmm, 4 Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of size 300x180x40mm thick, Class LV, Type 2, Flat, Concrete grade M-20 minimum, complete all as specified and as directed.
S&F MCCB 63 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and fixing on existing Panel Board of MAKE : HAVELLS and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed. MAKE : HAVELLS, Cat No. IHLFENF0063
S&F MCCB 100 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and fixing on existing Panel Board of MAKE : HAVELLS and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed. MAKE : HAVELLS, Cat No. IHLFENF0100#
S&F MCCB 125 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and fixing on existing Panel Board of MAKE : HAVELLS and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed. MAKE : HAVELLS, Cat No. IHLFENF0125#
S&F MCCB 200 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and fixing on existing Panel Board of MAKE : HAVELLS and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed. MAKE : HAVELLS, Cat No. IHLFENF0200#
S&F On Load Change Over Switch (Side Handle) in Sheet Enclosure, 415 Volt, 100 Amp rating 4 Pole, conforming to IS:13947 (Part I & II) and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed.
S&F HBC Fuse Link Bolted type, Central Tag type C-2 TTS, 415 Volt, 80 kA, Rating 400 Amp and fixing on existing Panel Board of MAKE : HAVELLS and connecting up including Taking down/out unserviceable Fuse Link, complete all as specified and as directed. MAKE : HAVELLS, Cat No. IHHTTSO400
M&L Breather Assembly including Silca Gel and fixing including Taking down/out unserviceable Breather Assembly and Silca Gel, complete all as specified and as directed.
S&F V Belt of No. 48 suitable for Compressor and fixing including Taking down/out unserviceable V Belt, complete all as specified and as directed.
Supply & Filling New Filtered and Tested completely Transformer Oil confirming to IS:33593 (4th Revision) suitable for Transformer/ Voltage Stabliser, etc. to the required Level, complete all as specified and as directed.
M&L Filtreration and Centrifusing of Transformer Oil for Improvement of Die-electric Strength of Transformer 11 KV/ 415Volt installed in different locations at NLP Mil Stn by Electrally Operated Oil Centrifusing Machine to achieve Die-electric Strength more than 60 KV at 3.0mm Gap for 1 Minute including Transformer Oil Testing Machine for Mearurment of Die-electric Strength, complete all as specified and directed.
M&L Cleaning, Scraping of Exposed Surfaces of Transformer 250 KVA, 11 KV/ 415 Volt, Indoor/ Outdoor Type and applying One coat of Synthetic Enamel Paint (Paint & Shade as approved) with Spray Painting Machine including Writing MES No. and Machine No. with Black Paint, Letters 50mm High and 15mm Wide, complete all as specified and as directed.
M&L Cleaning, Scraping of Exposed Surfaces of LT Panel/ Feeder Pillar /Pole Box, Indoor/ Outdoor Type and applying One coat of Synthetic Enamel Paint (Paint & Shade as approved) with Spray Painting Machine including Writing MES No. and Machine No. with Black Paint, Letters 50mm High and 15mm Wide, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4(20mm graded stone aggregate) reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
REPAIRS/MAINT OF EXTERNAL WATER SUPPLY
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Water Mains/ Pipes, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, providing Heaps along the Route of the Pipe Line with Surplus Soil (if any) in Soft/Loose Soil, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 25mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 32mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 50mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 80mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 100mm bore (dia) with Connections of any description, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 25mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 32mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 50mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 63mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 90mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
S&F Gate Valve 25mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 32mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 50mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 63mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 80mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 100mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 60x60x60 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 100x100x100 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
M&L Cleaning Existing Water Sump 42000 LITRE capacity by carry out the following Works, complete all as specified and as directed :- (a) Dewatering the Sump by employing Tulu Pump and Man Power. (b) Removing the Sludge, Muddy and dissolved Iron Water from the Sump by employing Man Power and required Tools & Plants. (c) Scrubbing the Algae from Walls, Corners, etc. completely by using Wire Brush and Man Power. (d) Washing Walls, Bottom, Conrners, etc. using Bleaching Powder. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
M&L Cleaning Existing Water Sump 80000 LITRE capacity by carry out the following Works, complete all as specified and as directed :- (a) Dewatering the Sump by employing Tulu Pump and Man Power. (b) Removing the Sludge, Muddy and dissolved Iron Water from the Sump by employing Man Power and required Tools & Plants. (c) Scrubbing the Algae from Walls, Corners, etc. completely by using Wire Brush and Man Power. (d) Washing Walls, Bottom, Conrners, etc. using Bleaching Powder. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
M&L Preparing Surfaces by removing Rust, etc. by rubbing of Surfaces with Wire Brush from Walls of Pressed Steel Storage OH Tank 42000 LITRE capacity having 20 Metre High Stagging and applying Two Coats of Aluminium Paint over a coat of Red Oxide Zinc Chrome Primer on Outer Surface Area & Stagging and applying Two Coats of Black Bituminous Paint (suitable for Drinking Water purpose) on Inside Walls and Connected Assesories including GI Pipes 80mm bore (dia) & 100mm bore (dia) and Other Accessories, etc. complete all as specified and as directed.
REPAIRS/MAINT OF PUMPS & MOTORS
M&L Repairs Monoblock Pump 3.0 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 3.0 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 3.0 HP capacity, complete all as specified and as directed.
M&L Taking out burnt Copper Windings from Motor of Monoblock Pump 3.0 HP capacity, Cleaning Slots of Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing after Rewinding, complete all as specified and as directed.
M&L Repairs Monoblock Pump 5.0 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 5.0 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 5.0 HP capacity, complete all as specified and as directed.
M&L Taking out burnt Copper Windings from Motor of Monoblock Pump 5.0 HP capacity, Cleaning Slots of Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing after Rewinding, complete all as specified and as directed.
M&L Repairs Monoblock Pump 10 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 10 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 10 HP capacity, complete all as specified and as directed.
M&L Taking out burnt Copper Windings from Motor of Monoblock Pump 10 HP capacity, Cleaning Slots of Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing after Rewinding, complete all as specified and as directed.
M&L Lifting of Submersible Pump & Motor Assembly 12.5 HP capacity alongwith complete Column Pipes, Submersible Cable, Safety Rope, etc. from the existing Borewell by employing Chain Pulley Block, etc., Dismantling Column Pipes by Opening Nuts, Bolts, Pump & Motor, etc, Seggregating & Stacking of Serviceable Column Pipes & Other Materials and Keep in Safe Custody for re-use, complete all as specified and as directed.
M&L Removing Submersible Pump & Motor Assembly 12.5 HP capacity to AGE E/M Store Yard, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Cover and Parts as required, Transporting defective Submersible Pump & Motor Assembly to nearest Workshop for Repairs, Repairing & Replacing of Unserviceable Parts, Reassembling Submersible Pump Motor Assembly after repaired, Transporting repaired Submersible Pump Motor Assembly back to Work Site, complete all as specified and as directed. NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Submersible Pump & Motor Assembly Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) The Cost of Minor Spares Parts/Items viz Nuts, Bolts, Washers, Gasket, etc. will deem to be include in the Quoted Unit Rate. (d) Rewinding of Submersible Motor, wherever invloves will be Measured and Paid separately under relevant Item.
M&L Dismantling Submersible Motor 12.5 HP capacity, Taking out burnt Windings, Cleaning of Slots of the Motor and Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing for Smooth Functioning after Rewinding, complete all as specified and as directed.
Supply only Bush for Impeller, 'C' type, Part No. 1091 (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Gun Metal Bush for Intermediate Part No. 933.1 (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Gun Metal Bush (Upper Part No. 1175, Lower Part No. 1176) (as per existing/ as approved) suitable for Submersible Motor 12.5 HP capacity, complete all as specified and as directed.
Supply only Gun Metal Impeller Part No. 151 complete (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Stainless Steel Sleeve for Impeller Part No. 2004 (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Stainless Steel Shaft of Standard size complete Part No. 180 (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Thurst Bearing for Part No. 1225 (as per existing/ as approved) suitable for Submersible Motor 12.5 HP capacity, complete all as specified and as directed.
M&L Lowering down Submersible Pump & Motor Assembly 12.5 HP capacity (after Repaired & Testing of Functionability) alongwith Column Pipes of any Size and Length, Submersible Cable, Steel Wire Rope, etc. with the help of Chain Pulley Block and Tool & Plants, Testing on Completion, complete all as specified and as directed. NOTE : Serviceable Materials viz Column Pipes, etc. will be keep in Safe Custody for Lowering . Rusted/ Unserviceable Column Pipes shall be replaced with New Pipes and the same will be Measured & Paid as 'Supply only' under approprite Item.
M&L Direct Online Starter suitable for 3.0 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*D
M&L Direct Online Starter suitable for 5.0 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*E
M&L Direct Online Starter suitable for 10 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*G
M&L Deluxe Automatic Star Delta Starter suitable for 12.5 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Star Delta Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPASDMB*
STANDARD ELECTRIC WINDERS
NChetia and Sons Trading
Bimal Trading Company
FREEZCON
Kaushik Enterprises
M/S A K BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .