Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 CrAccepted-AOC 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICATION 124103 | JHAJJAR | HARYANA | 124103 | ₹17.6 Cr Quoted ₹18.8 Cr | L1 | Accepted-AOC Admitted |
| 2 | L2₹19.5 CrRejected-AOC 1804 SECTOR 2 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹19.5 Cr | L2 | Rejected-AOC Rate on higher side |
Tender Value
₹14.4 Cr
EMD Value
₹28.8 L
Closing Date
27 Dec 2021, 5:00 pmClosed
Executive Engineer
Near Anaj Mandi Punhana
Providing and fixing of pumping machinery Providing and fixing of DG set transformer at Main Boosting Station Kot Bahin Uttawar laying jointing testing and commissioning of 800 mm id DI Rising Main from MBS Sultanpur to MBS Kot Bahin Uttawar
2021_HRY_200122_1
PHED/97870 dt. 10/12/2021
Open Tender
Civil Works
365 days
MBS Kot Bahin Uttawar
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
₹28.8 L
Yes
10 Feb 2022
16 Dec 2021
28 Dec 2021
16 Dec 2021
27 Dec 2021
16 Dec 2021
Amount
PART-B
Pumping Machinery
(iii) Supplying, erection, testing and commissioning of Horizontal split casing pumps with squirrel cage induction electric motor of miniumum 4 star rating as per detailed specification and drawings including testing commissioning etc. complete in all respects as per DNIT.
At MBS Kot/ Bahin/ Uttawar
i) 139 lps with 45 M Head with 155 HP (8400 LPM)
Supplying, erection, testing and commissioning of Cubical type L.T. Panel Board, having independent incoming and outgoing feeder, fabricated from 16 SWG, CRCA sheet, comprising with the following protection devices, including aluminium bus bar of cross section area for 1000 Amp. For phase and half cross suction area for neutral, suitable for operation on 415 volts, 3 phase, 50 cycle/seconds AC supply complete with internal wiring containing following items complete in all respects
For MBS Kot/ Bahin/ Uttawar (139 lps)
INCOMING FEEDER:-
i) 1000 Amp. TP E/o ACB equipped with 6NO+6NC auxiliary contacts, 240Volt. AC shut release, service position micro switch, 240V AC motor ACB will be horizontal draw out type.
ii) Earth fault and Over current relay of “LT-LK/C&S/BCH” - 1 No.
iii) Automatic Power Factor connector relay of LT-LK/AVOMECH, 6 stages - 1 No.
vi) Power capacitor bank of suitable rating to improve PF to 0.95 (whether one or three pumping operation) - 1 lot
vii) RYB LED Indicating lamp. - 1 set
viii) Incoming and outgoing cable box - 1 lot
ix) Busbar & suitable cross section for 1000Amps. For phase and Neutral of half of cross sectional area of main busbar. -1 Lot
OUTGOING FEEDER:-
i) 4Pole, 400Amp., MCCB - 3Nos.
iii) RYB Indicating lamps(LED) Type. - 8 sets
iv) 16Amp. MCB for vacuum pump - 2 Nos.
v) 16Amp. MCB for dewatering pump - 2 Nos.
vi) DoL starter - 4 Nos.
vii) Ameter(0-20Amp.), digital type - 4 Nos.
viii) 16Amp. MCB for lighting & auxiliary load - 4 Nos.
ix) Soft starter for 110 KW motor - 3 Nos.
Providing Chemical earthing with G.I. strip of 50 Sqmm. Confirm to ISI specification including cost of connecting material complete in all respect for all electrical equipment complete for Pumps, LT panel & Gen Set
For MBS Kot/ Bahin/ Uttawar
Pipes & Fittings, Providing, laying jointing, testing & commissioning C.I. D/F pipes, valves and specials required for suction & delivery pipes including testing etc. complete in all respects. All sluice valves shall be with gear assembly.
D/F C.I. Pipe = 350 mm i/d
D/F M.S. Pipe = 600 mm i/d
D/F C.I./ M.S. Specials various sizes
Providing, laying jointing, testing & commissioning of Hand operated Travelling crane with Trolley & Chain Block & girder etc. 5 tonne capacity including cost of all connecting material complete in all respect. For span 10 M.
For MBS Kot/ Bahin/ Uttawar
Sump Pump
Supply, Erection, testing & commissioning of sump pump of 900 LPM with 12 M Head alongwith G.I. pipe & cable and all connecting material complete in all respect as per specifications
For MBS Kot/Bahin
Dewatering pump
Supply, Erection, testing & commissioning of Dewatering pump of 100 lpm with 12 m head alongwith pipe & cable complete in all respect.
For MBS Kot/ Bahin/ Uttawar
Vacuum Pumps with piping
Supply, Erection, testing & commissioning of vaccum pump with 3 HP motor alongwith G.I. pipes and specials/valves arrangement complete in all respects as per specifications and drawings including all additional Civil work like digging trenches making khudas in walls and repairs there of still supporting suction and delivery line and thrust block at T/Junctions as per DNIT.
For MBS Kot/ Bahin/ Uttawar
Supply, Erection, testing & commissioning of Electromagnetic type flow meter suitable to measure discharge 50 cum / hr. to 160 cum/hr.as per specifications of
For MBS Kot/ Bahin/ Uttawar
Supply, fixing, testing & commissioning IVC make D.I. recoil non return type Zero Velocity valve having body in D.I. to IS: 1865 Gr. 400/15, Slant seat design, PN-1.6 rating, flanges to be drilled as per IS: 1538 complete in all respect to the satisfaction of Engineer-in-charge
Supply, fixing, testing & commissioning M.S. D/F pipe for scouring arrangement complete in all respects to the satisfaction of Engineer-in-Charge. 250mm i/d
Supply and placing in position coarse Yamuna sand to be filled under road cuts etc. to the satisfaction of the Engineer-in-Charge
Providing under reamed cast in situ piles using controlled concrete grade M-30 designed mix, 6.5m deep incldugin boring and getting out the soil and disposal upto a lead of 100 m including cost of steel reinforcement, joiting the tiles with main bars with welding and also all T & P reruined completed in all respect. the code be followed. 400 mm dia under reamed piled.
Providing and fixing M.S. Chequered plates 5 mm thick compelte inclduing cost of cutting & welding on steel truss bridge agra canal complete in all respect.
Supply & Paintings 2 coats of shalpoxy CTC (LB) type coalar epoxy to protect steel structure complete to the entire satisfaction of the Engineer-in-charge.
Hiring of heavy duty crane for lifting of truss bridges to plae on various crossings including cost of labour, fuel T&P etc. complete in all respects taking working period 2 days deploing of 4 nos. heavy duty crane on both end of banks including insurance of stucture to be placed and workmen executing the work of placing of truss bridge in position as complete job.
Upto span of 5 - 15 mtr.
Upto span of 15 - 30 mtr.
Upto span of 30 - 50 mtr.
Boring/excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/Boulders/any underground utility like foundation, water supply line coming in alignment or other underground obstruction under railway tracks agra - Delhi suitable for M.S Casing pipe of following sizes including caution & sign board complete in all respects.
i) Boring 1340 mm dia per insertion of 1300 mm i/d M.S. pipe
Providing and insertion of M.S. casing pipe (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS: 2062 of the following size cutting , beleling grinding & radio graphically welding of pipe as per IS-1182 complete in all respects including cartage to site of work and testing.
ii) For 1340 mm i/d M.S. casing pipe 20 mm thick
i) For 1124 mm o/d M.S. casing pipe 16 mm thick
Providing and Insertion of water carrier pipe 866 mm o/d M.S. pipe 10 mm thick (Fe-330 grade) fabricated as per IS:- 3589 of 1991, from steel plate conforming to IS:- 2062, including inner lining by cement concrete mortar which shall be prepared from aggregates/sand and cement mixed in ratio 2:1 by weight with minimum cement of contents of 450 kg/m3 having strength of 25Nmm2 after 20 days complete as per IS: 1916-1989 with latest revision, providing roller arrangement for smooth insertion & anchoring of pipe through out of length with HDPE spacers at A distance of 2 m apart to avoid contact of casing pipe & carrier pipe including cutting, jointing, Radiographic welding as per IS: 1182 Hydraulic testing complete in all respects including cartage of site work
Cleaning of surface of M.S. pipe (casing pipe and Carrier pipe) inner surface and outer surface by sand blasting at site to make the surface ready for P.U. coating/high built epoxy paint/polythene tap system complete in all respects.
Coating of outer surface & inner surface of casing pipe with epoxy paint for protection against corrosion complete in all respects.
Coating of outer surface of water carrier pipe with bitumenous paint for protection against corrosion complete in all respects.
Coating of inner surface of casing pipe with Food grade epoxy paint of R.D.S.O. specification No. M & C/PCN/111/88 to dry film thickness of 250 micron.
Providing and fixing H.D.P.E. spacer at a distance of 2 m apart to avoid contact of casing pipe and carrier pipe complete in all respects.
i) For 1100 mm o/d M.S. pipe
providing concrete block (1:11/2 :3) on both ends to plug annular space between casing and carrier pipe including cost of 5mm thick M.S. end plate complete in all respects.
i) For 1340 mm o/d casing pipe
Ground probe radar survey to check any under ground obstruction before finalzing the alignment .
Boring/excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/Boulders/any underground utility like foundation, water supply line coming in alignment or other underground obstruction under KGP Express way suitable for M.S Casing pipe of following sizes including caution &sign board complete in all respects.
i) For 1124 mm o/d M.S pipe 12 mm thick casing pipe.
Providing & insertion of M.S Casing pipe( Fe-330 grade ) fabricated as per IS : 3589 of 1991 from steel plates confirming to IS-2062 of following size including cutting , beveling grinding & radio graphically welding of pipes as per IS-1182 complete in all respect including cartage to site of work and testing.
i) For 1124 mm o/d M.S pipe 12 mm thick casing pipe.
Providing & insertion of water supply pipe 866 mm o/d M.S pipe 8mm thick (Fe-330 grade) fabricated as per IS :3589 of 1991, from steel conforming to IS :2062, including inner lining by cement concrete mortar which shall be prepared from aggregates/sand and cement mixed in ratio 2:1 by weight with minimum cement content of 450 kg/m^3 having strength of 25 N/mm2 after 20 days complete as per IS: 1916-1989 with latest revision, providing roller arrangement for smooth insertion & anchoring of pipe through out the length with HDPE spacers at a distance of 2 m apart to avoid contract of casing pipe & carrier pipe including cutting, joining, radio graphically welding as per IS: Hydraullic testing complete in all respects.
Cleaning of surface of M.S. pipe (casing pipe and carrier pipe) inner surface and outer by sand blasting at site to make the surface ready for P.U. coating/High built epoxy paint/polythene tap system complete in all respects.
Coating of outer surface of casing pipe with P.U. coating to dry film thickness 1500 micron for protection against corrosion complete in all respects.
Coating of outer surface of water carrier pipe with polythene tape system for protection against corrosion complete in all respects.
Coating of inner surface of casing pipe with High built epoxy paint to R.D.S.O. specification no M & C/PCN/111/88 to a dry film thickness of 250 micron
Providing and fixing H.D.P.E. spacer at a distance of 2 m apart to avoid contact of casing pipe and carrier pipe complete in all respects.
i) For 1124 mm o/d M.S. pipe
Providing concrete block 1:11/2 : 3 on both ends to plug the annular space between casing and carrier pipe including coast of 5mm thick M.S. end plate complete in all respects.
i) For 1124 mm o/d casing pipe
Ground probe radar survey to check any under ground obstruction before finalizing the alignment.
Providing chemical earthing with G.I. completed for all electrical aquipment complete as approved NIT .
For Pumps , LT panel & Gen Set for MBS Sultanpur
Supply, erection, testing & commissioning of 11 KV panel complete as per DHBVN specifications as per approved NIT.
Supply and installation of KV 3.5 CORE LT cable 630 sqm.armoured with termination kit complete in all respects as per approved NIT
Supply and fixing VCB 24 volts as per DHBVN requirement complete in all respects as per approved NIT.
Supply , erection, testing and commissioning of HT outdoor cable box XLPE 300 sqmm complete in all respect as per DHBVN specifications as per approved NIT.
Supply, erection, testing and commissioning of HT Indoor Cable box XLPE 300sqmm complete in all respect as per DHBVN specifications as per approved NIT.
Supply, erection, testing & commisioning of 11 KV Gang operated air break switch conforming to ISS -2544/1963 with latest amendments suitable for 400 amp. HT load & fitted on the "H" pole fcomplete the job in all respects upto the entire satisfaction of the Engineer -in-charge as per approved NIT .
Supply, erection , testing & commissioning of HT CT 20/5 amp. Complete as per DHBVN specification as per approved NIT.
Supply, erection , testing & commissioning of 11 KV PT complete as per DHBVN specification as per approved NIT.
Providing chemical earthing with cooper plate as per ISI specification complete as per DHBVN requirement as per approved NIT.
Operation & Maintenance
Operation & Maintenance during defect liability period of 1 year after 3 month trial run period
1st year maintenance after defect liability period of 12 months.
2nd year maintenance after defect liability period
3rd year maintenance after defect liability period
4th year maintenance after defect liability period
5th year maintenance after defect liability period
Bidder Name
Amount
Chahar Construction Co(GSTN-06AAMFC2979A1ZI)
Narender Singh Contractor(GSTN-06AXBPS0272N1Z8)
Narender Singh Contractor
Narender Singh Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid