Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | ₹23.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹24.2 LRejected-AOC D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 UDYAM UP 50 0021159 | LUCKNOW | UTTAR PRADESH | 226012 | ₹24.2 L | L2 | Rejected-AOC L2 |
| 3 | L3₹24.4 LRejected-AOC | ₹24.4 L | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Anoop Refrigeration L2 | COOL CURE L3 | M/S LUCKY VANIJYA L1 |
|---|---|---|---|---|---|---|
| 1.00PART-A…..Operation & CAMC of the following Package AC Plants.:- | ||||||
| 1.10 | Calibration Centre package A.C plants (2 X 15TR); as required; Make: VOLTAS, Model No: 50BA016N with: (a) Semi Hermetic Compressor - 15TR X 02 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No. | 1 | Set | 1,42,371 ₹1.4 L | 1,20,000 ₹1.2 L | 1,19,500 ₹1.2 L |
| 1.20 | Library package A.C plants (4X15TR); as required; Make: VOLTAS, Model No: DPUW-SH150S with: (a) Semi Hermetic Compressor -7.5TR X 08 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No. | 1 | Set | 3,30,920 ₹3.3 L | 2,50,000 ₹2.5 L | 2,29,500 ₹2.3 L |
| 1.30 | Conference hall package A.C plants (2X10TR); as required; Make: BLUE STAR, Model No: PAW1028 with: (a) Semi Hermetically Sealed Compressor-5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No. | 1 | Set | 93,515 ₹93,515 | 1,10,000 ₹1.1 L | 1,11,500 ₹1.1 L |
| 1.40 | Analytical Chemistry Lab. package A.C plants (2 X 10TR); as required; Make: BLUE STAR, Model No: PAW1028 with:(a) Semi Hermetically Sealed Compressor-5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps-2Nos. (c) Cooling Tower (with fan motor) -01 No. | 1 | Set | 1,06,109 ₹1.1 L | 1,10,000 ₹1.1 L | 1,11,500 ₹1.1 L |
| 2.00PART-B (includes Item no-2 and 3)…..Comprehensive AMC of room air conditioners (Split AC, Window AC, Floor Mounted AC,Cassette AC & Ductable AC), of below mentioned capacity (with supply installation testing of new compressor in case of failure of compressor) as complete: | ||||||
| 2.10 | 1.5TR/2.0TR Window AC | 129 | Each | 2,860 ₹3.7 L | 2,300 ₹3.0 L | 2,325 ₹3.0 L |
| 2.20 | 1.5TR Split AC | 266 | Each | 2,451 ₹6.5 L | 2,600 ₹6.9 L | 2,525 ₹6.7 L |
| 2.30 | 1.5TR Cassette AC | 22 | Each | 2,615 ₹57,530 | 5,500 ₹1.2 L | 3,450 ₹75,900 |
| 2.40 | 2TR Split AC/Floor Mounted AC | 50 | Each | 3,269 ₹1.6 L | 2,900 ₹1.4 L | 2,550 ₹1.3 L |
Tender Value
₹25.1 L
EMD Value
₹50,200
Closing Date
27 Jan 2026, 6:00 pmClosed
Director, CSIR-NML
CSIR-NML, Jamshedpur
Operation and Comprehensive AnnualMaintenanceContract(CAMC) of Package AirConditioning Plants, CAMC of Refrigeration and AirConditioning equipments, Miscellaneous works at Main Laboratory, Pilot Plants, Housing Complexes of CSIR-NML, Jamshedpur(2025)
2025_CSIR_260892_1
NML/ENG./WSM/eNIT/12(20)/25-26
Open Tender
Miscellaneous Works
365 days
CSIR-NML, Jamshedpur
As per eNIT
8 documents required · 8 mandatory
₹0
₹50,200
13 Mar 2026
5 Jan 2026
29 Jan 2026
6 Jan 2026
27 Jan 2026
6 Jan 2026
PART-A…..Operation & CAMC of the following Package AC Plants.:-
Calibration Centre package A.C plants (2 X 15TR); as required; Make: VOLTAS, Model No: 50BA016N with: (a) Semi Hermetic Compressor - 15TR X 02 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Library package A.C plants (4X15TR); as required; Make: VOLTAS, Model No: DPUW-SH150S with: (a) Semi Hermetic Compressor -7.5TR X 08 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Conference hall package A.C plants (2X10TR); as required; Make: BLUE STAR, Model No: PAW1028 with: (a) Semi Hermetically Sealed Compressor-5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Analytical Chemistry Lab. package A.C plants (2 X 10TR); as required; Make: BLUE STAR, Model No: PAW1028 with:(a) Semi Hermetically Sealed Compressor-5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps-2Nos. (c) Cooling Tower (with fan motor) -01 No.
PART-B (includes Item no-2 and 3)…..Comprehensive AMC of room air conditioners (Split AC, Window AC, Floor Mounted AC,Cassette AC & Ductable AC), of below mentioned capacity (with supply installation testing of new compressor in case of failure of compressor) as complete:
1.5TR/2.0TR Window AC
1.5TR Split AC
1.5TR Cassette AC
2TR Split AC/Floor Mounted AC
5.5 TR Ductable AC
7.5 TR Ductable AC
Comprehensive AMC for Water Chilling Units (WCU), Water Cooler(WC) & Water Cooler-Cum-Purifier (WCP); of below mentioned capacity (with supply installation testing of new reciprocating compressor in case of failure of compressor) as complete:
WCU upto 1.0TR
WCU upto 4TR
WC upto 40/80 Ltrs.
WC upto 150/150 Ltrs.
WCP 80 ltr; The tank capacity: 80Ltr & Cooling capacity: 60LPH. Filtration process: 3-stage Purification process viz. (a) Sediment filter (b) Carbon Filter (c) UV e-boiling /filtration; SV Switch, SMPS Power Supply; UV Lamps, & all accessories; as complete.
PART-C (Miscellaneous Work includes Item no-4 to 15)...Installation,Testing & Commissioning of window type room Air-Conditioner, including supply of sal wood frame for fixing of Window AC frame, well varnished/ polished teak wood beat (3"or 4"Wide, thickness: 0.5") around the wooden frame, making pockets for window AC, plastering, POP work /Painting to match with the site as complete.
Shifting/Installation,Testing & Commissioning of window type room Air-Conditioner with little modification in the existing window/pocket as complete. (Excluding supply of sal wood frame and teak wood beat).
Supply & Fixing of Copper pipe (suction+ discharge line) duly insulated with nitrile foam tube on surface of wall, as complete.
For 1.5TR Split AC/Cassette AC
For 2TR Split AC
Supply & Fixing of Copper pipe (suction+discharge line) duly insulated with nitrile tube in recess/concealed including cutting, making holes, POP work, painting & making good to match with existing site as complete.
For 1.5TR Split AC/Cassette AC
For 2 TR Split AC
Supply and fixing of following sizes of uPVC (sch. 40) water line pipe along with accessories in surface/recess including cutting the wall/iron saddling work and making good the same as complete.
Installation, testing & commissioning of split A.C 1.5TR/2.0TR (Hi-wall mounted) IDU & ODU including refrigerant charging, leak tesing, as complete. (Excluding supply of compressor,Copper pipe, Drain Line, Cable).
Supply of 1.1KV grade, FR/FRLSH PVC insulated and PVC sheathed Copper multistrand conductor flexible cables suitable upto 1100V conforming to IS:694 of following sizes etc, as required:
3(core)X2.5 sq.mm
3(core)X4 sq.mm
Supply, Installation, Testing, and Commissioning of New Compressor, including system flushing (with nitrogen), vacuumising, leak testing & supply of refrigerant as complete. N.B: The agency has to provide one year warranty on complete work.
1.5TR (Rotary Compressor)
2TR (Rotary Compressor)
Dismantling of Window/Split AC (Cassette/Hi-wall mounted AC) as complete & handing over the material to the daparatment, as per direction of engineer in-charge.
Supply of Window AC Grill suitable for Window AC (Model No.GWRAC018ER010) Make: Carrier, with all accessories.
Dismantling of old fountain accessories like pipe lines etc. & Design, Fabrication, Supply installation testing & commissioning of new three-stage fountain in existing pool/pond-2nos connected together as complete. For ready reference the image of the fountain is given in scope of work. The various features/componets to be used are as below: (a) 3-stage Brass Nozzle-2Nos; (b)1HP,1-Ph subermsible pump motor set/suitable capacity-1No.- to achieve the targeted water spray height of 6 feet to 7 feet ; (c.) 30 Watt (minimum), RGB Light IP-68 -6Nos. (3Nos.-For each pool/pond). (d) SMPS Power Suppy-1No; (e) RGB controller for providing minimum six different colours; (f) Water proof, painted, fountain operating panel with all components; (g) uPVC/GI pipe, fitting, valves, strainer, bypass valves to adjust the spray height; (h) 3Cx1.5 Sq.mm connecting PVC flat copper cable of voltage:1100V, confirming to IS:694 for submersible pump, 4Cx1.5sq.mm copper, FR/FRLS, PVC Sheathed, flexible cable of voltage:1100V, confirming to IS:694 for other connection of suitable length; etc. as complete. N.B: The fountain operating panel should be fixed at the suitable place/as per direction of engineer-in charge.
Dismantling of defective window AC blower motor/ split AC indoor or Outdoor Motor & supply & fixing of new copper wound motor of required capacity for 1.5TR/2TR air-conditioners as complete.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.54 MB
AGR_GCC_WORKS.pdf
Tender Documents • 0.52 MB
SOP_norms_for_Safety_in_Works.pdf
Other Document • 0.20 MB
List_Cooling_Appliances_2025.pdf
Other Document • 3.74 MB
Quarterly_CheckingReport.pdf
Other Document • 0.53 MB
Cooling_Appliances_Special.pdf
Other Document • 2.51 MB
BOQ_301767.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid