Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.2 L+₹94,753 (4.07%)Rejected-AOC D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.4 L+₹1.2 L (5.09%)Rejected-AOC | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Anoop Refrigeration L2 | COOL CURE L3 | M/S LUCKY VANIJYA L1 |
|---|---|---|---|---|---|---|
| 1.00PART-A…..Operation & CAMC of the following Package AC Plants.:- | ||||||
| 1.10 | Calibration Centre package A.C plants (2 X 15TR); as required; Make: VOLTAS, Model No: 50BA016N with: (a) Semi Hermetic Compressor - 15TR X 02 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No. | 1 | Set | 1,42,371 ₹1,42,371 | 1,20,000 ₹1,20,000 | 1,19,500 ₹1,19,500 Lowest |
| 1.20 | Library package A.C plants (4X15TR); as required; Make: VOLTAS, Model No: DPUW-SH150S with: (a) Semi Hermetic Compressor -7.5TR X 08 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No. | 1 | Set | 3,30,920 ₹3,30,920 | 2,50,000 ₹2,50,000 | 2,29,500 ₹2,29,500 Lowest |
| 1.30 | Conference hall package A.C plants (2X10TR); as required; Make: BLUE STAR, Model No: PAW1028 with: (a) Semi Hermetically Sealed Compressor-5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No. | 1 | Set | 93,515 ₹93,515 Lowest | 1,10,000 ₹1,10,000 | 1,11,500 ₹1,11,500 |
| 1.40 | Analytical Chemistry Lab. package A.C plants (2 X 10TR); as required; Make: BLUE STAR, Model No: PAW1028 with:(a) Semi Hermetically Sealed Compressor-5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps-2Nos. (c) Cooling Tower (with fan motor) -01 No. | 1 | Set | 1,06,109 ₹1,06,109 Lowest | 1,10,000 ₹1,10,000 | 1,11,500 ₹1,11,500 |
| 2.00PART-B (includes Item no-2 and 3)…..Comprehensive AMC of room air conditioners (Split AC, Window AC, Floor Mounted AC,Cassette AC & Ductable AC), of below mentioned capacity (with supply installation testing of new compressor in case of failure of compressor) as complete: | ||||||
| 2.10 | 1.5TR/2.0TR Window AC | 129 | Each | 2,860 ₹3,68,940 | 2,300 ₹2,96,700 Lowest | 2,325 ₹2,99,925 |
| 2.20 | 1.5TR Split AC | 266 | Each | 2,451 ₹6,51,966 Lowest | 2,600 ₹6,91,600 | 2,525 ₹6,71,650 |
| 2.30 | 1.5TR Cassette AC | 22 | Each | 2,615 ₹57,530 Lowest | 5,500 ₹1,21,000 | 3,450 ₹75,900 |
| 2.40 | 2TR Split AC/Floor Mounted AC | 50 | Each | 3,269 ₹1,63,450 | 2,900 ₹1,45,000 | 2,550 ₹1,27,500 Lowest |
Tender Value
₹25.1 L
EMD Value
₹50,200
Closing Date
27 Jan 2026, 6:00 pmClosed
Director, CSIR-NML
CSIR-NML, Jamshedpur
Operation and Comprehensive AnnualMaintenanceContract(CAMC) of Package AirConditioning Plants, CAMC of Refrigeration and AirConditioning equipments, Miscellaneous works at Main Laboratory, Pilot Plants, Housing Complexes of CSIR-NML, Jamshedpur(2025)
2025_CSIR_260892_1
NML/ENG./WSM/eNIT/12(20)/25-26
Open Tender
Miscellaneous Works
Item Rate
365 days
CSIR-NML, Jamshedpur
As per eNIT
8 documents required · 8 mandatory
₹0
₹50,200
13 Mar 2026
5 Jan 2026
29 Jan 2026
6 Jan 2026
27 Jan 2026
6 Jan 2026
PART-A…..Operation & CAMC of the following Package AC Plants.:-
Calibration Centre package A.C plants (2 X 15TR); as required; Make: VOLTAS, Model No: 50BA016N with: (a) Semi Hermetic Compressor - 15TR X 02 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Library package A.C plants (4X15TR); as required; Make: VOLTAS, Model No: DPUW-SH150S with: (a) Semi Hermetic Compressor -7.5TR X 08 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Conference hall package A.C plants (2X10TR); as required; Make: BLUE STAR, Model No: PAW1028 with: (a) Semi Hermetically Sealed Compressor-5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Analytical Chemistry Lab. package A.C plants (2 X 10TR); as required; Make: BLUE STAR, Model No: PAW1028 with:(a) Semi Hermetically Sealed Compressor-5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps-2Nos. (c) Cooling Tower (with fan motor) -01 No.
PART-B (includes Item no-2 and 3)…..Comprehensive AMC of room air conditioners (Split AC, Window AC, Floor Mounted AC,Cassette AC & Ductable AC), of below mentioned capacity (with supply installation testing of new compressor in case of failure of compressor) as complete:
1.5TR/2.0TR Window AC
1.5TR Split AC
1.5TR Cassette AC
2TR Split AC/Floor Mounted AC
5.5 TR Ductable AC
7.5 TR Ductable AC
Comprehensive AMC for Water Chilling Units (WCU), Water Cooler(WC) & Water Cooler-Cum-Purifier (WCP); of below mentioned capacity (with supply installation testing of new reciprocating compressor in case of failure of compressor) as complete:
WCU upto 1.0TR
WCU upto 4TR
WC upto 40/80 Ltrs.
WC upto 150/150 Ltrs.
WCP 80 ltr; The tank capacity: 80Ltr & Cooling capacity: 60LPH. Filtration process: 3-stage Purification process viz. (a) Sediment filter (b) Carbon Filter (c) UV e-boiling /filtration; SV Switch, SMPS Power Supply; UV Lamps, & all accessories; as complete.
PART-C (Miscellaneous Work includes Item no-4 to 15)...Installation,Testing & Commissioning of window type room Air-Conditioner, including supply of sal wood frame for fixing of Window AC frame, well varnished/ polished teak wood beat (3"or 4"Wide, thickness: 0.5") around the wooden frame, making pockets for window AC, plastering, POP work /Painting to match with the site as complete.
Shifting/Installation,Testing & Commissioning of window type room Air-Conditioner with little modification in the existing window/pocket as complete. (Excluding supply of sal wood frame and teak wood beat).
Supply & Fixing of Copper pipe (suction+ discharge line) duly insulated with nitrile foam tube on surface of wall, as complete.
For 1.5TR Split AC/Cassette AC
For 2TR Split AC
Supply & Fixing of Copper pipe (suction+discharge line) duly insulated with nitrile tube in recess/concealed including cutting, making holes, POP work, painting & making good to match with existing site as complete.
For 1.5TR Split AC/Cassette AC
For 2 TR Split AC
Supply and fixing of following sizes of uPVC (sch. 40) water line pipe along with accessories in surface/recess including cutting the wall/iron saddling work and making good the same as complete.
Installation, testing & commissioning of split A.C 1.5TR/2.0TR (Hi-wall mounted) IDU & ODU including refrigerant charging, leak tesing, as complete. (Excluding supply of compressor,Copper pipe, Drain Line, Cable).
Supply of 1.1KV grade, FR/FRLSH PVC insulated and PVC sheathed Copper multistrand conductor flexible cables suitable upto 1100V conforming to IS:694 of following sizes etc, as required:
3(core)X2.5 sq.mm
3(core)X4 sq.mm
Supply, Installation, Testing, and Commissioning of New Compressor, including system flushing (with nitrogen), vacuumising, leak testing & supply of refrigerant as complete. N.B: The agency has to provide one year warranty on complete work.
1.5TR (Rotary Compressor)
2TR (Rotary Compressor)
Dismantling of Window/Split AC (Cassette/Hi-wall mounted AC) as complete & handing over the material to the daparatment, as per direction of engineer in-charge.
Supply of Window AC Grill suitable for Window AC (Model No.GWRAC018ER010) Make: Carrier, with all accessories.
Dismantling of old fountain accessories like pipe lines etc. & Design, Fabrication, Supply installation testing & commissioning of new three-stage fountain in existing pool/pond-2nos connected together as complete. For ready reference the image of the fountain is given in scope of work. The various features/componets to be used are as below: (a) 3-stage Brass Nozzle-2Nos; (b)1HP,1-Ph subermsible pump motor set/suitable capacity-1No.- to achieve the targeted water spray height of 6 feet to 7 feet ; (c.) 30 Watt (minimum), RGB Light IP-68 -6Nos. (3Nos.-For each pool/pond). (d) SMPS Power Suppy-1No; (e) RGB controller for providing minimum six different colours; (f) Water proof, painted, fountain operating panel with all components; (g) uPVC/GI pipe, fitting, valves, strainer, bypass valves to adjust the spray height; (h) 3Cx1.5 Sq.mm connecting PVC flat copper cable of voltage:1100V, confirming to IS:694 for submersible pump, 4Cx1.5sq.mm copper, FR/FRLS, PVC Sheathed, flexible cable of voltage:1100V, confirming to IS:694 for other connection of suitable length; etc. as complete. N.B: The fountain operating panel should be fixed at the suitable place/as per direction of engineer-in charge.
Dismantling of defective window AC blower motor/ split AC indoor or Outdoor Motor & supply & fixing of new copper wound motor of required capacity for 1.5TR/2TR air-conditioners as complete.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.54 MB
AGR_GCC_WORKS.pdf
Tender Documents • 0.52 MB
SOP_norms_for_Safety_in_Works.pdf
Other Document • 0.20 MB
List_Cooling_Appliances_2025.pdf
Other Document • 3.74 MB
Quarterly_CheckingReport.pdf
Other Document • 0.53 MB
Cooling_Appliances_Special.pdf
Other Document • 2.51 MB
BOQ_301767.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .