Loading…
Loading…
Tender Value
₹2.8 Cr
EMD Value
₹5.5 L
Closing Date
12 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DRAWING
29 conditions · 9 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a) Attested Certificates(s) issued by Executive or Nominated Authority of the government Departments or Semi-Government/Public Sector Undertakings for the value of the work done for them during the qualifying period including current financial year certifying the bill amounts paid Agreement-wise and Date-wise or attested photo copy of such certificate. Such certificates will be accepted only from Govt. / Govt. bodies / PSUs authorities. Certificates issued by Private Bodies will not be considered.
(b) Audited Balance Sheets clearly indicating contractual receipts from the works done for Govt./ Govt. bodies / PSUs/Pvt. Organization in the P&L Account of the balance sheet duly certified by the Chartered Accountant for the completed & current Financial years.
NOTE: (i) Financial Year shall normally, be reckoned as 1st April to 31 st March of the Next Year. However, for Turnover Criteria, the Financial Year as applicable to the Company /Tenderer is to be considered, if it defers from the above. (ii) Current Financial year is reckoned as the incomplete Financial year in which the date of tender submission falls. (iii) Chartered Accountant statements duly indicating yearly receipts will not be considered until and unless backed by Audited Balance Sheets. (iv) If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
If JV firms are allowed to participate; Financial eligibility of the JV Firm shall be adjudged based on satisfactory fulfilment of the Para No.17.15.2 of part-I of IRSGCC- 2019 for J.V guide lines (with upto date correction slip).
NOTE: If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
The individual / firm should have minimum valid "B" grade electrical license or above and should be on their own name/Firm name issued by the Electrical Inspectorate of the respective State Electrical Licensing Board". The License should have been issued on a date prior to the date of Tender opening. Clear scanned copy is to be submitted along with the tender. A copy of license should be uploaded through IREPS with their offer, failing which the tender will be rejected.
Similar Nature of work: "Supply, installation, testing and commissioning of solar power generating system at least 5 kWP capacity. Note: This is the minimum capacity of either grid connected or off grid systems". a copy of similar nature of work should be uploaded through IREPS with their offer, failing which the tender will be rejected.
94 conditions · 9 needing a document upload
TENDER SHALL BE REJECTED if it is not accompanied by the following:
Cost of tender document & EMD deposited through IREPS e- payment
In case of Partnership firm : The tender form shall be submitted only in the name of partnership firm.
In case tenderer is JV Firm : The tender form shall be submitted 1.1.2 only in the name of the JV and not in the name of any constituent member.
Uploading of Certificate in support of Technical Eligibility (As detailed in Standard Technical Criteria).
Submission of Certificate(s) in support of Financial Eligibility (As detailed in Standard financial criteria).
IN CASE OF ADVERTISED TENDER VALUE IS MORE THAN RS. 20 CRORES: Bid capacity is applicable, the tenderers should submit proforma attached in DOCUMENTS. In case, the tenderer/s failed 1.3.1 to upload BID CAPACITY PROFORMA along with offer, their/his offer shall be considered as incomplete and will be rejected summarily.
In case tenderer is other than sole proprietorship firm, following documents shall be uploaded by the tenderer:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered). [iv]An undertaking by all partners of the partnership firm that they are not blacklisted or 1.4.1 debarred by Railways or any other Ministry / Department of the Govt. of India / any State Govt. from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 1.4.2 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of 1.4.3 Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iv) copy of PAN number of the Company.
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 1.4.4 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Incase JV Firms are allowed to participate: Uploading of MEMORANDUM OF UNDERSTANDING as per the format given in "Documents attached with tender" and also below documents.
In case one or more members is/are Proprietary Firm or HUF, the following documents shall be enclosed:: A copy of notarized affidavit on Stamp Paper declaring that his/her Concern is a 1.5.1 Proprietary Concern and he/she is sole proprietor of the Concern OR he/she is in position of "KARTA" of Hindu Undivided Family (HUF) and he/she has the authority, power and consent given by other partners to act on behalf of HUF.act on behalf of HUF.
In case one or more of the members of the JV is/are partnership firm(s), following documents shall be submitted:]:(a)A copy of the Partnership Deed, (b)A copy of consent of all the partners or individual authorized by partnership firm, to enter into the Joint 1.5.2 Venture Agreement on a stamp paper, (c)A copy of Power of Attorney (duly registered as per prevailing law) in favour of the individual to sign the MOU/JV Agreement on behalf of the partnership firm and create liability against the firm.
In case one or more members of the JV is/are companies, the following documents shall be submitted: (a)A copy of resolutions of the Directors of the Company, permitting the company to enter into a JV agreement, (b) A copy of Memorandum and 1.5.3 Articles of Association of the Company. (c) A copy of Authorization/copy of Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender, sign MOU/JV Agreement on behalf of the company and create liability against the company.
IN CASE THE TENDER VALUE MORE THAN RS. 50 LAKHS; Tenderers shall submit a notarized affidavit on a non-judicial stamp paper stating that all their statements / documents submitted along with bid are true and factual.
Uploading of Declaration regarding Employment of Retired Engineer/Retired Railway Officer as per clause no.17 of Part-I of IRSGCC. [in the format attached in - Documents]
Uploading of NEFT FORM - as per the format attached with the tender document.
The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
Uploading of Statement Showing the particulars of Works on Hand & Works Completed as per the format attached to the tender document.
Uploading of certificate by local suppliers in regard to meeting the Minimum Local Content requirement to avail benefits under Public Procurement Policy Order-2017 (A) for procurement order of value less than Rs. 10 crores: self certificate in accordance with Para-9(a) of Public Procurement(Preference to Make in India) Order 2017. (B) For Procurement Order of value more than Rs. 10 crores, the certificate from Statutory auditor/cost auditor/practicing CA as the case may be in accordance with Para-9(b) of Public Procurement (Preference to Make in India) Order 2017.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
IN CASE OF SINGLE PACKET TENDERS; CONSORTIUM AGREEMENTS, JOINT VENTURE FIRMS AND MOUS SHALL NOT BE CONSIDERED
IN CASE OF TWO PACKET TENDERS CONSORTIUM AGREEMENTS AND MOUS SHALL NOT BE CONSIDERED . BUT JOINT VENTURE FIRMS ARE CONSIDERED FOR ELIGIBILITY.
CONDITIONS FOR PARTICIPATION OF PROPRIETARY FIRM / PARTNERSHIP FIRM /PRIVATE LIMITED COMPANY / LIMITED COMPANY/ JV FIRMS:
In case the tenderer is an individual / proprietary concern, the experience and turnover shall be in the name and style of the Individual / Proprietary concern only.
In case the tenderer is a Partnership Firm, the experience and received contractual payments shall be in the name and style of the firm only. The other guidelines at Clause 18 of Part I of 4.1.1 IRSGCC shall be applicable . Note: The partner of a Partnership Firm cannot claim the credentials of Partnership firm to the extent of his share either during the subsistence of the Partnership firm or after its dissolution.
FOLLOWING DOCUMENTS SHALL BE ENCLOSED:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create 4.2.1 liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) and AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company 4.2.2 (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iii) copy of PAN number of the Company.
In case of JOINT VENTURE (JV) FIRMS: Clause No.17 of Part-I of IRSGCC with upto date correction slip shall be applicable in all aspects for Participation of Joint Venture[JV] firms in works tenders. JV firm should submit Memorandum of 4.2.3 Understanding[MOU] as per the format attached as annexure to the tender in DOCUMENTS. Submission of all other documents by JV firm / Members of JV should also be as per Cl.No.17.14 of Part-I of IRSGCC.
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 4.2.4 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 4.2.5 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Uploading of other relevant documents connected to the tender; such as Declaration regarding employment of Retired Engineer/ Retired Railway officer, NEFT Form, List of Personnel/Organization, List of Plant/machinery, Particulars of works on hand and completed (As per the formats attached in the list of Documents)etc.
Hyderabad Division: Provision of Solar Pumps, Energy Efficient Pumps and Solar Street Lights
5-OEW-26-27-SrDEE-M-HYB
5-OEW-26-27-SrDEE-M-HYB
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹5.5 L
12 May 2026
16 Apr 2026
28 Apr 2026
93 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,76,97,656 | ||
| — | 5.00 | — | — | ||
| Supply, erection, testing & commissioning of 5 HP (3.7KW) solar submersible pump with VFD drive. Three phase with Single phasing protection, over load protection, dry run protection | — | — | — | 2,43,750 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing & commissioning of 5 KWp rooftop on Grid solar pump panels with MPPT technology with SPV array, Module mounting suitable & operate for 5 HP solar pump set, confirming to IEC or latest. | — | — | — | 13,88,600 | |
| — | 5.00 | — | — | ||
| Supply, erection, connecting, testing and commissioning of pump control panel consisting of solar inverter with MPPT (Maximum Power Point Tracking), three phase VFD, auto/manual change over system, single phase preventer, over load, dry run protection system etc. for three phase 5 HP vertical type submersible pump suitable to operate on an input voltage of 415V 50Hz AC system. | — | — | — | 3,70,500 | |
| — | 5.00 | — | — | ||
| Design, supply & erection of solar panel structure with hot dip galvanized module mounting structure for 5kWp solar power plant fabricated with "C" channel and 'L' angles with required stainless steel of SS304 grade hardware such as bolts, nuts and washers etc., to hold the solar panels, including foundation for mounting structure with 1:2:4 PCC construction. | — | — | — | 2,85,000 | |
| — | 5.00 | — | — | ||
| Supply and installation of polycarbonate Array junction box with IP-65 protection complete with blocking diodes, MOVs etc. for 5Kwp solar panel. The array junction box shall be dust, vermin, and water proof and shall have suitable cable entry points fitted with cable glands of appropriate size for both incoming and outgoing cables. Suitable markings are to be provided on the bus bar for easy identification and cable ferrules shall be fitted at the cable termination points for identification. | — | — | — | 76,000 | |
| — | 5.00 | — | — | ||
| Supply and erection of DC cables, Earthing and lightening arrestor as per standards. (i) Supply of DC cable i.e. PVC insulated sheathed, UV resistant unarmored single core 4.0 Sq.mm copper cable of 1100volts grade from the solar panel to the array junction box and to the VFD pump panel duly laying the cable in PVC conduit (cost inclusive) with proper fixing and connecting, testing & commissioning. | — | — | — | 1,23,500 | |
| — | 5.00 | — | — | ||
| Supply, erection, testing & commissioning of 3 HP (2.2 KW) solar submersible pump with VFD drive. Three phase with Single phasing protection, over load protection, dry run protection. | — | — | — | 2,22,300 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing & commissioning of 3 KWp rooftop on Grid solar pump panels with MPPT technology with SPV array, Module mounting suitable & operate for 3 HP solar pump set, confirming to IEC or latest. | — | — | — | 8,25,000 | |
| — | 5.00 | — | — | ||
| Supply, erection, connecting, testing and commissioning of pump control panel consisting of solar inverter with MPPT (Maximum Power Point Tracking), three phase VFD, auto/manual change over system, single phase preventer, over load, dry run protection system etc. for three phase 3 HP vertical type submersible pump suitable to operate on an input voltage of 415V 50Hz AC system. | — | — | — | 3,30,600 | |
| — | 5.00 | — | — | ||
| Design, supply & erection of solar panel structure with hot dip galvanized module mounting structure for 3kWp solar power plant (150WpX20 modules) fabricated with "C" channel and 'L' angles with required stainless steel of SS304 grade hardware such as bolts, nuts and washers etc., to hold the solar panels, including foundation for mounting structure with 1:2:4 PCC construction. | — | — | — | 2,85,000 | |
| — | 5.00 | — | — | ||
| Supply and installation of polycarbonate Array junction box with IP-65 protection complete with blocking diodes, MOVs etc. for 3Kwp solar panel. The array junction box shall be dust, vermin, and water proof and shall have suitable cable entry points fitted with cable glands of appropriate size for both incoming and outgoing cables. Suitable markings are to be provided on the bus bar for easy identification and cable ferrules shall be fitted at the cable termination points for identification. | — | — | — | 76,000 | |
| — | 5.00 | — | — | ||
| Supply and erection of DC cables, Earthing and lightening arrestor as per standards. (i) Supply of DC cable i.e. PVC insulated sheathed, UV resistant unarmored single core 4.0 Sq.mm copper cable of 1100volts grade from the solar panel to the array junction box and to the VFD pump panel duly laying the cable in PVC conduit (cost inclusive) with proper fixing and connecting, testing & commissioning for 3 KWp plant | — | — | — | 1,23,500 | |
| — | 2400.00 | — | — | ||
| Supply and laying of HDPE pipe with required fittings and joints of 40mm outer dia. Manufacturing of PE-100 grade material. The pipe pressure class of PN-16. The pipe should be suitable for drinking/raw water application as per direction of engineer at site. | — | — | — | 3,24,000 | |
| — | 1300.00 | — | — | ||
| Supply, laying, connecting and commissioning of 3 core 6 Sq.mm copper flat cable as per the direction of site Engineer. | — | — | — | 4,86,200 | |
| — | 1000.00 | — | — | ||
| Supply, laying, connecting and commissioning of 3 core 4 Sq.mm copper flat cable as per the direction of site Engineer. | — | — | — | 1,68,000 | |
| — | 1100.00 | — | — | ||
| Supply, laying, connecting and commissioning of 3 core 2.5 Sq.mm copper flat cable as per the direction of site Engineer. | — | — | — | 1,52,900 | |
| — | 300.00 | — | — | ||
| Supply & erection of 50 mm dia "B" class G.I. pipe should be of BS 1287 & EN 1025 ut side thickness 60.8mm, pipe thickness 4.5mm & weight measuring 6.9kg per mtr and as per the directions of Engineer at site (20' length & 2" thread on both the ends) | — | — | — | 2,67,900 | |
| — | 12.00 | — | — | ||
| Supply & fixing of Screw ends type Non-Return Valve, 50mm dia with all the connecting accessories as the direction of the engineer at site. | — | — | — | 51,000 | |
| — | 12.00 | — | — | ||
| Supply & fixing of flange ends type gate valve, 50mm dia with all connecting accessories as per the direction of the engineer at site. | — | — | — | 80,160 | |
| — | 20.00 | — | — | ||
| Supply and fixing of 4" length 50mm dia heavy duty coupler suitable for 50mm dia 'B' class GI pipe as per the direction of site Engineer. | — | — | — | 5,760 | |
| — | 26.00 | — | — | ||
| Supply of stainless steel sand/mud proof submersible pump of 5HP vertical type energy efficient submersible pump with a total head of 275Mts with a discharge of 20LPM at total head suitable to work on 3-ph with pump maximum outer dia 98mm as per the directions of engineer at site | — | — | — | 11,41,166 | |
| — | 30.00 | — | — | ||
| Supply, testing, installation & commissioning 3Ph, 10HP mono submersible, 415V, delivery 50mm, head range 35mts-50mts, 1000LPM, star delta connection including all connected accessories etc. as per the direction of site Engineer. | — | — | — | 16,98,150 | |
| — | 26.00 | — | — | ||
| Supply & fixing of control panel consisting of DOL starter, single phase preventer with power automatic ON & OFF system, with dry run, pilot lamps, selector switch, Voltmeter, Ammeter in suitable sheet steel box of 16 SWG upto 7.5HP pumps including all connected accessories as per the directions of engineer at site. | — | — | — | 3,27,600 | |
| — | 35.00 | — | — | ||
| Supply & fixing of control panel consisting of STAR AND DELTA starter, single phase preventer with power automatic ON & OFF system, with dry run, pilot lamps, selector switch, Voltmeter, Ammeter in suitable sheet steel box of 16 SWG upto 30 HP pumps including all connected accessories as per the directions of engineer at site. | — | — | — | 15,01,605 | |
| — | 5.00 | — | — | ||
| Supply and erection of 30W All-in-One Solar Street Light with 6 meter GI pole as per specification enclosed | — | — | — | 1,62,275 | |
| — | 5.00 | — | — | ||
| Supply and erection of 30W Hybrid All-in-One Solar Street Light with 6 meter GI pole as per specification enclosed | — | — | — | 1,78,750 | |
| — | 10.00 | — | — | ||
| Excavation of pit for octagonal pole/ poles of suitable size in all type of soils as per the direction of engineer at site | — | — | — | 10,000 | |
| — | 8.00 | — | — | ||
| Provision of concrete foundation and constructing the plinth as per the directions of engineer at site. | — | — | — | 32,024 | |
| — | 10.00 | — | — | ||
| Supply, transportation, erection and commissioning of 500 LPD Non-Pressurized Evacuated Tube Collector type Solar Water heating System with temperature application of 60 degrees with stainless steel - 304L grade inner tank with PUF Insulation and aluminum cladding for outer cover, suitable EPDM rubber pipe connection from Collector to Solar Tank with electrical Heating back up etc., with 3 years guarantee for Solar system and additional 2 years warranty. Similar to make: TATA/ BHEL/ BOSCH/ ETC/ V-GUARD/ RACOLD | — | — | — | 7,06,100 | |
| — | 999.00 | — | — | ||
| Supply, installation of CPVC pipe only suitable for hot water application (upto 90 deg C) with thermal insulating properties 1.25" dia connection with required bends & tees etc. | — | — | — | 5,59,440 | |
| — | 1000.00 | — | — | ||
| Supply, installation of CPVC pipe suitable for cold water application in blue colour with thermal insulating properties 1.25" dia connection with required bends & tees etc. | — | — | — | 3,50,000 | |
| — | 30.00 | — | — | ||
| Supply, installation, testing & commissioning of 1 1/4" Gate Valve (ISI Marked) (Screwed End) made of brass with connected materials | — | — | — | 36,000 | |
| — | 30.00 | — | — | ||
| Supply and provision of ½" size ISI marked push cock type stainless steel water tap in every solar water heating system. | — | — | — | 15,000 | |
| — | 10.00 | — | — | ||
| Supply and installation Sintex 1000LTR water tank with suitable stand with all connected works. Make: Sintex/ Plasto | — | — | — | 1,09,790 | |
| — | 1000.00 | — | — | ||
| Supply of LT XLPE aluminium cable complete of size 4Cx16 sq.mm. size confirming to IS: 7098 Pt.I or latest | — | — | — | 1,82,000 | |
| — | 1000.00 | — | — | ||
| Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 16 Sq.mm | — | — | — | 9,000 | |
| — | 1186.00 | — | — | ||
| Supply and fixing of G.I. wire earth continuity of 8 SWG G.I. wire | — | — | — | 10,674 | |
| — | 750.00 | — | — | ||
| Excavation of cable trench 30 cm widex90cm deep in all types of soils for LTUG cable as per the site conditions and as per directions of Rly. Engineer. | — | — | — | 97,500 | |
| — | 200.00 | — | — | ||
| Cutting of asphalted road/ concrete/ cement/ under the track etc., and excavation of cable trench 30 cm widex90cm deep road etc., for laying of LTUG cable. After laying of cable the trench should be brought to its original position by providing tar/ concrete/ cement as per the site conditions and as per directions of Rly. Engineer. | — | — | — | 43,200 | |
| — | 950.00 | — | — | ||
| Supply & erection of HDPE pipe of 50 mm dia, PN-6, PE-100 of material grade as per IS: 4984-2016 or latest as per the directions of Engineer at site | — | — | — | 1,71,000 | |
| — | 1.00 | — | — | ||
| Supply of Electric Pipe Threader kit with upgraded machines similar to model VZ-PTM- 2300 of make VOLTZ and as per the instructions of engineer at site | — | — | — | 42,904 | |
| — | 1.00 | — | — | ||
| Supply of 160 A Inverter Welder with Advanced IGBT Technology Hot Start, ARC Force. Anti-Stick with 1 year warranty make similar to ibell black IBL M220-39 and as per the instructions of engineer at site | — | — | — | 9,096 | |
| — | 4.00 | — | — | ||
| Supply of handheld laser measuring device similar to model PRO GLM 50-23 G, Make Bosch and as per the instructions of engineer at site | — | — | — | 27,272 | |
| — | 18.00 | — | — | ||
| Design, supply and fixing of 5 KWp rooftop on-grid solar plant with MPPT technology with Mono PERC Solar Panels of 535wp or above, Module Mounting Structure, Power Conditioning Unit (PCU) consisting of Maximum Power Point Tracker (MPPT), Inverter (5 KW output puresine wave inverter), and Controls and Protections, interconnect cables and switches including net meter, earthing arrangements, Lighting arresters, etc. all complete as per the standard specifications and as per the direction of site Engineer. | — | — | — | 57,78,360 | |
| — | 6.00 | — | — | ||
| Design, supply and fixing of 20 KWp rooftop on-grid solar plant with MPPT technology with Mono PERC Solar Panels of 535wp or above, Module Mounting Structure, Power Conditioning Unit (PCU) consisting of Maximum Power Point Tracker (MPPT), Inverter (20 KW output puresine wave inverter), and Controls and Protections, interconnect cables and switches including net meter, earthing arrangements, Lighting arresters, etc. all complete as per the standard specifications and as per the direction of site Engineer. | — | — | — | 77,04,480 | |
| — | 55.00 | — | — | ||
| Design, supply, installation, testing and commissioning of online monitoring system of solar power plant with 5 years validity and access to web portal, including SIM charges, server charges and connected accessories etc. as per the direction of Engineer at site. | — | — | — | 9,08,600 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NEFTForm.pdf
ATTACHMENT
GCCACS11dt.13.03.2026.pdf
ATTACHMENT
ExperianceCertificate.pdf
ATTACHMENT
GCC_April-2022_2022_New.pdf
ATTACHMENT
CorrectionSlip2022_CE-I_CT_GCC-2022Policy14.07.2022_1.pdf
ATTACHMENT
ACS-3toGCCApril.2022RBCE_CE-I-CT2023_04_26.pdf
ATTACHMENT
ACS-2toGCC-2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
ApprovedTB5-OEW-26-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].