| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC H NO 2884 SEC 14 PART 2 125001 | HISAR | HISAR | HARYANA | 125001 | ₹22.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.9 L+₹51,739.80 (2.31%)Rejected-Finance 790 STREET NO 1 PATEL NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | ₹22.9 L+₹51,739.80 (2.31%) | L2 | Rejected-Finance L2 |
Tender Value
₹20.4 L
EMD Value
₹40,866
Closing Date
20 Mar 2024, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Extension of the existing Terminal Building at Maharaja Agrasen Airport, Hisar (Phase-II) (Pdg. VRF, FIDS and PA System only) RECALL
2024_HRY_368558_1
2024A4950031 BAD7 43E3 B1E7 7AB2F3620523666BAR
Open Tender
Electrical Works
Works
60 days
Hisar
2 documents required · 2 mandatory
₹1,000
₹40,866
Yes
21 Jun 2024
14 Mar 2024
21 Mar 2024
14 Mar 2024
20 Mar 2024
14 Mar 2024
Amount
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
Supply, Installation, Testing and commissioning of Ceiling mount Speaker Max Power - 15W or higher , Rated power (PHC) - 15 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 115dB/ 103dB, Effective frequency range (-10 dB) - 120-18000 Hz, Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70, Rated voltage - 100 V,(Rates are included GST) Make Honeywell/JBL/AHUJA
Supply Installation Testing and Commissioning of 17U rack for 450 MM depth switch Mounting with Fan and 15 AmpX3 socket power Strip, PDU, Hardware Mounting Kit (Rates are included GST)Make: Comrack/Valrack/ cp plus .
Supply Installation Testing and Commissioning of 1 KVA UPS Overvoltage cut-off device (OVCD), Support for Generator Compatible with Wide Input. Wide Input Voltage Window (110 – 280Vac) for Indian Environmental Conditions and for Optimized BatteryPerformance. UPS would support SNMP Mnagaer and web browser On-Line With 2-hour Backup (Rates are included GST) MAKE APC/ElNOVA/MICROTEK.
Supply, Installation, Testing and commissioning of single core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc. (Rates are included GST) Make: Finolex/plaza/Havells
Supply of wireless Single channel UHF Handled Microphone with 20m W(max) Modulation mode FM with Red 1 ed for low battery .Green Led for Mic on 9 V battery Power Requirment (Rates are included GST) Make Honeywell / JBL / Ahuja.
Supply Installation Testing and Commissioning of Commercial series QLED 4K, High quality 3840*2160 display 7*24 working with latest android google play, fully Smart, with wi-fi, Bluetooth ,75` LED Monitor, Full HD, 24x7 operation,2 HDMI Port, Component Video Inputs, 1 Digital Audio Out, VGA Port complete in all respect (Rates are included GST) (Make: Sony/Samsung/Panasonic/LG)
SITC of Ceiling hanging Stand FOR LED TV With Heavy M.S Channel with all Nut Bolt and Assessries .(Rates are included GST)
Supply Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V plus /- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The ODU shall have low noise condenser fans with extrenal static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. For enhanced energy savings the COP of each refrigerant circuit system mentioned below shall be 7.5 minimum at 50% load, at AHRI Condition in cooling mode. The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency. The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.(Rates are included GST) Make ( Daikin/Hitachi//voltas/O`GENERAL) 10 HP
ODU CONNECTION KIT complete in all respects (rates are included GST)
VRV Indoor Units: Supply, installation, testing and commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation, corded remote control etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall also have dual sensors additionally which detect the presence of people and floor temperature to provide comfortable air- conditioning and energy saving. (Rates are included GST) Make ( Daikin/Hitachi//voltas/O`GENERAL) 0.8 TR Cassette Round Flow with wireless remote
VRV Indoor Units: Supply, installation, testing and commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation, corded remote control etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall also have dual sensors additionally which detect the presence of people and floor temperature to provide comfortable air- conditioning and energy saving. (Rates are included GST) Make ( Daikin/Hitachi//voltas/O`GENERAL) 1.6 TR Cassette Round Flow with wireless remote
VRV Indoor Units: Supply, installation, testing and commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation, corded remote control etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall also have dual sensors additionally which detect the presence of people and floor temperature to provide comfortable air- conditioning and energy saving. (Rates are included GST) Make ( Daikin/Hitachi//voltas/O`GENERAL) 2.6 TR Cassette Round Flow with wireless remote
VRV Indoor Units: Supply, installation, testing and commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation, corded remote control etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall also have dual sensors additionally which detect the presence of people and floor temperature to provide comfortable air- conditioning and energy saving. (Rates are included GST) Make ( Daikin/Hitachi//voltas/O`GENERAL) 4 TR Cassette Round Flow with wireless remote
Supply Installation, testing and commissioning of Y-joints as required to connection the outdoor unit and indoor units complete in all repect (Rates are included GST) make:- Voltas / Daikin/ Hitachi/OGENERAL
COPPER PIPE Supplyand Fixing of Interconnecting copper refrigerant pipe work 19 mm / 13 mm thick between indoor and outdoor units as per specifications. (Rates are included GST) Make - Mandev / Totaline / Maxflow 6.4 mm O.D. (Insulation -13 mm Thick)
COPPER PIPE Supplyand Fixing of Interconnecting copper refrigerant pipe work 19 mm / 13 mm thick between indoor and outdoor units as per specifications. (Rates are included GST) Make - Mandev / Totaline / Maxflow 9.5 mm O.D. ( Insulation - 13 mm Thick )
COPPER PIPE Supplyand Fixing of Interconnecting copper refrigerant pipe work 19 mm / 13 mm thick between indoor and outdoor units as per specifications. (Rates are included GST) Make - Mandev / Totaline / Maxflow 12.7 mm O.D. ( Insulation - 13 mm Thick )
COPPER PIPE Supplyand Fixing of Interconnecting copper refrigerant pipe work 19 mm / 13 mm thick between indoor and outdoor units as per specifications. (Rates are included GST) Make - Mandev / Totaline / Maxflow 15.9 mm O.D. ( Insulation - 13 mm Thick )
COPPER PIPE Supplyand Fixing of Interconnecting copper refrigerant pipe work 19 mm / 13 mm thick between indoor and outdoor units as per specifications. (Rates are included GST) Make - Mandev / Totaline / Maxflow 22.2 mm O.D. ( Insulation - 19 mm Thick )
COPPER PIPE Supplyand Fixing of Interconnecting copper refrigerant pipe work 19 mm / 13 mm thick between indoor and outdoor units as per specifications. (Rates are included GST) Make - Mandev / Totaline / Maxflow 28.6 mm O.D. ( Insulation - 19 mm Thick )
DRAIN PIPING Supply and fixing of PVC drain water piping complete with fittings, support as per specification and insulated with 6 mm thick insulation. (Rates are included GST) Make - Suprime/ Prince/ Ravindra 32 mm
Communication wire 2 core * 1.5 sq mm Cu shielded with PVC Counduiting (Rates are included GST) make - Polycab/ Grandlay/ RR Kabel
Dhamija Power Constructions
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .