Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹17.3 L+₹11,672.75 (0.68%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹17.5 L+₹23,841.45 (1.38%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹17.5 L+₹31,760.63 (1.84%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹17.6 L+₹33,734.56 (1.96%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹22.3 L
EMD Value
₹44,640
Closing Date
4 Jan 2021, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
SPECIAL REPAIR TO BLDG NO NP-03 AT SUB AREA UNDER GE (WEST) PATHANKOT
2020_MES_400289_1
CWE/P-99/2020-21
Open Tender
Civil Works
Item Rate
180 days
Pathankot
class E and above Category (a) (i)
9 documents required · 9 mandatory
₹500
Yes
GE (West) Pathankot
₹44,640
Yes
13 Jan 2021
3 Dec 2020
6 Jan 2021
3 Dec 2020
4 Jan 2021
17 Dec 2020
Amount
Demolition of brick or stone masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Demolition of cement concrete or lime concrete (un-reinforced) of any description and in any position not otherwise and removing the debris outside from defence land, complete all as specified and as directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing near cement slurry with 3 kg of cement per sqm, complete all as specified and directed.
M&L for brick work with old size sub class ‘B’ burnt bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:4), complete all as specified and directed.
All as per item No 05 here-in-before but except old size sub class 'B' bricks. Note : Old bricks retrieved from demolition shall be used.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4, complete all as specified and directed.
Dismantling water tanks and removing from site of capacity exceeding 500 ltr and not exceeding 1000 ltr, complete all as specified and directed.
S&F of Rotational moulded polythene water storage tank tripple layer cylindrical vertical with closed threaded top 1000 litre capacity hoisted and fixed in position, including all fittings, complete all as specified and directed.
S&F of 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms), complete all as specified and directed.
Demolition of existing roof treatment of any description such as wornout tarfelt, mortar of any description and any thickness, shrubs, vegetation, tree, terracing tile (where as required) or concrete bedding and Cleaning of all foreign material such as fungus, mass, dust ,debris etc by brushing and dusting,washing down with water, sprinkle water on the surface and ensure water does not stand any where and making the roof surface levelled with 20 mm thick rendering in cement mortar (1:4) with water roofing compound (as per manufacturer's instructions). Applying a coat of approved cold applied bituminous oil based primer (IS-3384) @0.30 litre/sqm complete all as specified and directed Applying roof treatment on top of roof with APP modified membrane with non-woven polyster reinforcement (centre core) with thermal insulation with white mineral gravel finish on upper side of weight not less than 3.5 kg/sqm & thickness not less than 3mm, laid by torch application method with overlap 100 mm on length side and 100 mm on the width side as per manufacturer's instructions complete all as specified and directed by Engr –in Charge. Note: WPC shalll be measured and paid separetely.
Supply only liquid water proofing compound, complete all as specified and directed
M&L for coloured Glazed ceramic coloured tiles 300 x 450 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in cement mortar 1:4, complete all as specified and directed. Note:-The texture ,colour ,shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and rates also including in this item for necessary raking circular cutting or notching and waste on tiles.
M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exc 0.11Sqm but n exc. 0.18Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed
M & L for marble work 18-20mm thick (table rubbed and polished green shade) in cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc, complete all as specified or as directed including taking down of old stone slabs.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over and including screed bed or bedding layer 20mm thick in cement mortar 1:6, complete all as specified and directed. Note :-The size of kota stone shall not be less than 55 cm x 55cm & Rate included for all cutting ,waste including machine cutting to make it square or rectangular,cutting and polishing by machine.
M & L for machine cut kota stone slab 14-18 mm thick on walls skirting dado, riser steps and pillar laid over cement screed 10 mm thick in cement mortar 1:4 as backing coat complete and jointed with grey cement and pigment to match the shade of the slab including rubbing and granite polishing, complete all as specified or as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm and not exceeding 4Sqm each including taking out hold fast, complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5 Sqm each including taking out hold fast, complete all as specified and directed.
Taking down shutters of any description exceeding 1 sqm and not exceeding 2 sqm each, complete all as specified and directed.
Refixing of shutters in same opening of any description exceeding 1.00 sqm but not exceeding 2.00 sqm, complete all as specified and directed.
M&L for pressed steel farmes 165 x60 mm x1.25 mm thick with one or more rebates including fixing necessary lugs/ hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate, complete all as specified and directed including cement concrete type B-1, 1:2:4 using 20 mm graded crushed stone aggregate as in filling hollow of frame with plain cement concrete and hold fast complete all as specified and directed.
M&L for pressed steel farmes 105 x60 mm x1.25 mm thick with one or more rebates including fixing necessary lugs/ hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate, complete all as specified and directed including cement concrete type B-1, 1:2:4 using 20 mm graded crushed stone aggregate as in filling hollow of frame with plain cement concrete and hold fast complete all as specified and directed.
S&F PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Sq tube complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed.
S & F of Framed work such as grills, grating etc with ends of bars shouldered and or riveted, or forged into spikes, framed guard bars, barrel, iron doors, ladders, balusters, walkway, frame work of water tanks and similar work confirming to Fe-290 Gde E-165, complete all as specified and directed.
S&F in repair second class hard wood Plain fillets, square, rectangular or triangular in section and secured with nails or screws, clean sawn and sectional area exceeding 13 Sq cm & not exceeding 25 Sq cm, including two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
S & F of Continuous (piano) hinges, stainless steel 40mm Width of flaps (when open) fixed with screws, complete all as specified and directed
Supply and fixing of Hasp and staple, 150 mm long aluminium anodised, including bolt to hinge plate and fixed with screws, complete all as specified. ISI Marked
S&F of Factory made solid panel PVC shelf as in cup board shelves/ shutter of required size consisting of panel 20mm thick celuka PVC ply and for supporting the hold of shelf and self provided 3 edged in size 18mm x 18mm as per required length. The front size of the edge visible in the front side of the shelf to be edge lipped by 18mm width x 1mm thick PVC sheet of density 600Kg / cum density manufactured by an ISO-9000 certified company, using solvent. PVC ply shall be fixed in wall by M.S screw of required length, complete all as specified and directed.
S&F of 150mm ordinary rat tail mild steel rod pattern springs including roller and roller plate, complete all as specified and directed.
S&F of 300 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed with machine nut and bolts, complete all as specified and directed.
S&F of Stainless steel butt hinges, medium weight, cold rolled,100mm long, complete all as specified and directed.
S&F of Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
S&F of extruded aluminium alloy handles, fabricated type, anodised of size 150mm and fixed, complete all as specified and directed.
M&L for factory made Solid Panel PVC door shutters 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stile and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles and rail with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing to frame at site as per specification complete all as specified and directed.
M&L for 40mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
M&L for factory made Glazed and skelton shutters 35mm thick of 2nd class hard wood rail & style open rebated and prepared to receive glass or wire gauze etc. shutters (without shash bars), size of members of shutters as specified in SSR Part-1, secton 8, clause 8.24(a) kiln seasoned and pressure treated, complete all as specified and directed.
M&L two coats of synthetic enamel paint including preparation on wooden or wood base surface of any description, not otherwise described over 10cm width or girth, complete, all as specified and directed
Preparation of old painted wooden or wood based surfaces of any description not otherwise described, over 10cm width or girth including applying one coat of synthetic enamel paint, complete all as specified.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.
M&L for preparation of old steel surfaces of any description over 10cm in girth and applying a coat of synthetic enamel paint, complete all as specified and as directed.
Supply and fixing of 25mm outer dia stainless steel decorative drapery rod ( Model No- SS-25FL of Vista) of thickness 20 gauge and for every 01 RM length, provide 10 numbers stainless steel wings (Model No:- SS CRNG of Vista) with 50 mm dia and proportionate for part there off, with stainless steel brackets ( Model:- SS 25 BR, Vista) near to ends with stainless steel finials ( Model:- SS-1 of Vista with adapter) for 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/windows Including necessary fittings
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone/ concrete, glazed with putty or fixed with beads, complete all as specified and directed.
S & F of sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads in squares not exc. 0.50 sqm in each pane, complete all as specified or as directed.
Dismantling of wire mesh of any thickness, fixed with steel or wood fillets if any, complete all as specified and directed.
S&F of stailness steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples or nuts and bolts including MS flat strip as required at site includiing taking out old unserviceable wire mesh from doors/ steel windows etc, complete all as specified and directed.
M&L for Box type steel windows and ventilator comprised of tubular frame and shutters made out of 1.25 mm thick M S sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter including stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm,03mm thick sheet glass ordinary quality or 03 mm thick Figured glass as directed with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150 mm long for each leaf and including 10 mm square bar grills at spacing as shown on drg welded to FI frame work, including all other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer including taking down existing spoiled and unserviceable windows/ventilators of any type (wooden/steel), complete all as specified and directed
Taking up or down of steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal, complete all as specified and directed.
Taking up or down of steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal, complete all as specified and directed.
Taking up or down of steel tubing of 25mm to 32mm steel tubing and connections including cleaning for refixing or removal, complete all as specified and directed. Note :- Refixing will be paid separately.
S&F of Steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like elbow, tee, socket, bend etc and fixed to wall and ceilings or laid in floors, complete all as specified.
Fixing only of 15mm bore old Steel water tubing including all new galvanized fittings and fixed to wall, ceiling or laid in floor, complete all as specified and directed. Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings)
M&L for Steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like elbow, tee, socket, bend etc and fixed to wall and ceilings or laid in floors, complete all as specified and directed.
Fixing only of 20mm bore old Steel water tubing including all new galvanized fittings and fixed to wall, ceiling or laid in floor. complete all as specified and directed. Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings)
M&L for Steel water tubing of 25 mm bore ‘medium grade’ galvanized with all fittings like elbow, tee, socket, bend etc and fixed to wall and ceilings or laid in floors, complete all as specified.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick masonry, complete all as specified.
Supply and fixing in repairs Bib taps 15mm bore of cast copper alloy chromium plated (ISI marked) fancy type, screwed down, high presure, screwed both ends for iron pipe or for brass ferrule, complete all as specified and directed.
Supply and fixing in repairs 15mm bore angle valve CP wall with half turn flange, brass chromium plated fancy type, complete all as specified and directed.
Supply and fixing in repairs stop valve of cast copper alloy chromium plated with long shank concealed type with wall flange screwed down high pressure screwed both ends for iron pipe or for unions 15 mm bore, complete all as specified and directed.
S&F in repair central hole basin mixer without pop up waste system with 450mm long braided hoses, brass chromium plated, fancy type with all accessories and fixed, complete all as specified and directed.
Supplied and fixed in repairs Viterous China wash basin, oval type under / over counter shape of size 550x460mm laid over stone slab including brackets of approved size including necessary cutting for and pinning in ends of brackets in cement mortar 1:3 including 32mm dia chromium plated waste coupling, complete all as specfied and as directed.
S&F in repair Vitreous china urinal half stall complete incl providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and incl 60mm long brass secrews, pointing around urinal in back in cement including fixing automatic cistern with brackets, flush pipe, grating and union for discharge pipe, complete all as specified and directed.
S&F 15mm dia 450 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes of 15mm bore, complete all as specified and directed.
S&F in repair for vitreous china squatting pan 'Orissa' pattern of size 580mm x 440mm white with integral foot rest with 'P' or 'S' trap 100mm, front or back inlet and connection to trap with cement mortar etc incl lime concrete bedding in 1:3 with brick bats, complete all as specified or as directed.
Supply and fxing in repairs of PVC valve less symphonic action type flushing cistern 10ltr capacity , low level white with inlet ball valve float and handle including brackets including 32mm dia PVC flush pipe for low level cistern including all joints, complete all as specified.
S&F of soap dish brass chromium plated Round/oval shaped fixed to wall with PVC gutty and CP screws, complete all as specified and directed.
M&L for Tubular towel rail, ISI marked 60cm long between flanges , 20mm dia 'D' type Brass Chromium plated incl necessary brackets, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
S&F of Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed
S&F in repairs of Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long fixed with chromium plated brass screws and wooden/plastic cleats, complete all as specified and directed.
S&F in repair of 20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe fixed in repair, complete all as specified and directed.
S&F in repair of 25mm bore gun metal globe or gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe fixed in repair, complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for RCC nominal mix 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in slab supported on walls, columns in floors, roofs, landings, balconies and in shelves, complete all as specified and directed.
M&L for Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces of concrete, complete all as specified and directed.
M&L for Precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4), complete all as specified and directed. Note : Reinforcement shall be measured and paid separately
M&L for mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia or securing with clips quality, complete all as specified and directed.
M&L for (a) cleaning all foreign material such as fungus, mass, dust, debris etc by brushing and dusting, washing down with water, sprinkle water on the surface and ensure water does not stand anywhere. If it is so, the roof surface shall be levelled with cement. (b) Applying a coat of approved cold applied bituminous oil based primer (IS-3384) @ 0.30 litre/Sqm complete all as specified and directed. (c) Applying roof treatment on top of roof with APP modified membrane with non-woven polyster reinforcement (centre core) with thermal insulationwith white mineral gravel finish on upper side of weight not less than 3.5 Kg/Sqm and thickness not less than 3 mm, laid by torch application method with overlap of 100 mm length side and 100 mm on the width side as per manufacturer's instructions, complete all as specified and directed.
M&L for PCC 1:5:10 type E-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, filling of sunken floor complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floors, complete all as specified and directed.
Dismantling/ taking down of cast iron or rienforced concrete or PVC soil waste and drain pipe 75mm or 100 mm dia with all fittings, complete all as specified and directed.
M&L for PVC (SWR) pipes 110mm dia of any length single socketed with rubber ring joint fixed to walls as drainage pipe, complete all as specified and directed.
M&L for PVC (SWR) pipes 75mm dia of any length single socketed with rubber ring joint fixed to walls as drainage pipe, complete all as specified and directed.
M&L for PVC (SWR) pipes 75mm dia of any length single socketed with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
M&L in repair PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement, complete all as specified and directed
M&L for PVC (SWR) bends any radius 110mm bore, complete all as specified and directed.
M&L for PVC (SWR) bends any radius 75mm bore, complete all as specified and directed.
M&L for PVC (SWR) bends any radius 110mm junction single, (single T) equal or unequal with access door, complete all as specified and directed.
M&L for PVC (SWR) 75mm junction double (double T), equal or unequal with access door complete all as specified and directed.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed.
S&F for PVC (SWR) vent cowl 110mm, complete all as specified and directed.
M&L for PVC (SWR) 'S' trap 125/110 mm bore, complete all as specified and directed.
S&F of stack clamp made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including boltsand nuts and securing ends of stays to wall or roof for 100mm bore pipe, complete all as specified.
S&F of stack clamp made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including boltsand nuts and securing ends of stays to wall or roof for 75mm bore pipe, complete all as specified.
Cutting holes into or through brick walls built in cement mortar or cement lime mortar and stone walls built in line mortar or walls of depth lime concrete (Superficial area excluding 150 Sq cm but not exceeding 400 Sq cm), complete all as specified and as directed.
Taking down of cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land, complete all as specified and as directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and fair complete walls/fins facia/ chajjas, complete all as specified and directed on exterior surfaces.
M&L for Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete walls/fins facia/ chajjas, complete all as specified and directed on exterior surfaces.
M&L for two coats plaster 35 mm thick (20mm +15mm) on rough concrete surfaces of fin, facia, chajjas and similar article in cement mortar 1:3 finished even and smooth without using extra cement in any height including necessary scaffolding, complete complete all as specified and directed. Note:- Two coat plaster shall be carried out as mentioned in clause 14.18 of SSR-2009, Part-I complete all as specified and directed.
M&L for Rendering 10 mm thick on fair faces of concrete surfaces in cement mortar 1:3 on ceiling surface including finished even and smooth without using extra cement, complete all as specified and directed.
M&L for Preparation of old plastered/ un-plastered wall surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots, and applying one coat of white wash on walls including cornices, pilasters etc, complete all as specified.
M&L for preparation of old decorated plastered or unplastered surfaces of walls, including cornices, pilasters etc by washing, rubbing, stopping, brooming down with steel wire brushing, scrapping down smoke soots, moulds, efflorescent salts and trading oil greasy spots, complete and providing one coat of white wash on ceiling comlpete all as specified and directed.
M&L for complete removal of existing treatment from wall surfaces and applying two coats of cement base paint over a coat of cement primer, complete all as specified and directed.
M & L for prepration of newly plastered surfaces/roof facia and applying two coats of cemenrt base paint over a coat of cement primer, complete all as specified and as directed.
M&L for Preparation of new plastered surface of wall and applying white cement based wall care putty (Birla. JK white) on the surfaces with minimum 1.5 mm uniform thickness and making surface absolutely smooth by applying two coats of oil bound distemper (water thinable) white or tinted over one coat of primer on wall surface, complete all as specified and directed.
M&L for complete removing existing wall surface treatment and finishes incluidng cornices etc by scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation any type by vigorously wire brushing, brooming, dusting and finally washing with water to clear the cracks absolutely free from any kind of existing finishes and foreign materials, making good minor surface imperfections such as holes, dents, cracks etc in cement mortar 1:3 and applying white cement based wall care putty (Birla/JK white) on the surfaces with minimum 1.5mm uniform thickness and making surface absolutely smooth, applying two coats of oil bound distemper over a coat of primer on wall surface, complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floor and pavings not exceeding 15 cm thickness below and above ground level complete all as specified and as directed by Engr-in-Charge.
M&L for Cement concrete (1:3:6), type C-2 using 40 mm graded crushed stone aggregate as in plinth protection & paving 75mm thick laid in slope finished the even & fair including making joints at every 2.5m and at corner filled with bitumen 85/25 grade and 1:2 part of sand by weight, complete all as specified and directed
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removal of excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point, complete all as specified and directed
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by Engr –in Charge
Demolition or breaking of drain pipe (salt glazed ware, AC, PVC or reinforcement concrete) set in cement mortar/concrete, complete all as specified and directed.
S&F of unplasticisted PVC drainage pipe 160mm dia type 'B' with wall thickness 4mm (min) of pressure rating 4KN/Sqm laid in tranches and joined with cement solvent including testing, complete all as specified and directed
M&L for Concrete bed to drain pipes including packing under and haunching against the sides of pipes for 150mm drain pipe after they are laid in PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate), complete all as specified and directed.
M&L Non abrasive paving (rectified endura) cement concrete coloured tiles 300 mm x 300 mm x 10 mm thick set jointed and pointed in neat cement slurry mixed with pigment laid over 15 mm thick screed bed in cement mortar 1:6, complete all as specified and as directed.
M&L for Plain cement Concrete 1:2:4 type-B1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts plinth band, bed blocks and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified.
Taking down carefully of copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L for Point wiring for light/fan/bell point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel sunkun boxes having thickness as specified not less than 2mm with 3mm bakalite laminated sheet for switches and sockets, including 1.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour, complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) (b) On RCC roof ceiling PVC conduit shall be provided on surface for fan with proper fixing clips, completre all as specified and directed.
Description all as per item No.120 here-in-before but for 5 Pin socket outlet 5 Amps point on independent board with PVC insulated copper conductor cable 1.5sqmm, complete all as specified and directed.
All as per above item no 120.00 here in before but for one 3 pin socket outlet 5 amp on same board, complete all as specified and directed.
M&L for Point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel sunkum boxes having thickness as specified not less than 2mm with 3mm bakalite laminated sheet for one 3 pin socket outlet 15 Amp on independent board including 2.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour, complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) complete all as specified and directed.
S&F of Switch piano flush type one way 5 Amps single pole 240 volts, complete all as specified and directed.
S&F of Switch piano flush type one way 15 Amps single pole 240 volts, complete all as specified and directed.
S&F of socket outlet 2 in 1, 3 pin 5 amps flush type 240 volt, complete all as specified and directed.
S&F of socket outlet 2 in 1, 3 pin 5 and 15 amps flush type 230 volt complete all as specified and directed.
S&F of Lamp holder PVC/Polycarbonate type with back plate having matching colour to holder for angle/batten fittings (ISI marked) complete all as specified and directed.
S & F of Ceiling rose of 65x50mm three therminals isolated body (ISI marked), complete all as specified.
S&F for celling fan regulator electronic socket type 5 stage speed variation (ISI marked), complete all as specified and directed.
Supply and Fix of in replacement existing unsv sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast, bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as required at site or directed.
Taking down of ceiling fan by disconnecting the electric connection & dismantling the blades & after removing from ceiling/roof of bldg by de-screwing the nut bolt etc, complete all as specified and directed.
Rehanging only of ceiling fan and connecting up including provision of PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm from ceiling rose or connector to fan including minor repairs such as replacement of locking pin, hanging bracket, reel insulators, bolts, nuts, capacitor of required capacity, bearing of suitable size etc and spraying one coat of synthetic enamel paint of required color, complete all as per required and directed by Engr-in-Charge.
S&F LED smart lamp, B22 type 14 watt, complete all as specified & directed
S & F of energy saving decorative LED box type with LED Rod 20 watt (4 Feet), 230 volts, 6500 K energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings. (Note power factor should not be less than 0.95), complete all as specified and directed.
S & F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete, all as specified and directed by Engr-in-charge.
S & F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification, complete all as specified and directed by Engr-in-charge.
S&F of MCB SP 240 volts any rating from 20 to 40 ampsamps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and directed by Engr-in-charge.
S&F of MCB SPN 240 volts any rating from 6 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and directed by Engr-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, connected to galvanized iron wire 4mm dia as earth lead by means of bolts,nuts and washers of GI up to test point,earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3 of SSR Part I, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI medium grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result, complete all as specified and directed. Note: (i) The rate quoted include cost of 7.5 metre earthing wire with protection pipe. (ii) Excavation and earth work is deemed to be included in the rate quoted.
M & L for for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing AC ventilating fans, Single phase, 230 volts 300 mm sweep or 12" HD Ex fan (900 RPM) and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side ( on outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
S & F of sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and comprising of the following (a)MCCB four pole 100 Amp AC 415 volts 25 KA=01 NO as incoming and 12 nos. MCB SP 40 Amps, C series as outgoing. (Note :- (i)The DB shall be VTPN (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii) connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. (iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (vi)MCCB's and MCB's should have a same make as of DB.
Supply and laying in replacement of existing unserviceable/ burnt submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 2x6 sqmm drawing into and including concealed PVC rigid conduit of 20mm dia , 1.8 mm wall thickness and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 6 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing, complete all as specified & directed. Note: (i) Two runs of 6 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 6 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 20mm dia , 1.8 mm wall thickness wiil be measured as a one unit. (ii) Proper colour coding is to be followed as per IS Specification. (iii) Test certificates of cables to be submitted before commencement of work/ claiming for payment. (iv) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.
Supply and fix of bldg security light fittings energy saving high efficiency LED street light fitting 25 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including I bracket of size 32 mm diia bent to shape having length on less than 1.5 metre fixing with clamp etc and making connections using cordflexible 3 core copper cable of size 23 / .0076 from ceiling rose / PVC connector to light fittings, complete all as specified and as directed by Engr-in-Charge.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
M/S SALARIA BUILDERS
kay gee construction co
VIKRAM SINGH MANHAS
OMKAR SHARMA AND CO
Om Sai Ram Builders
M/S Raghuvanshi Builders
malghotra construction co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .