Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC COLABA MUMBAI | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹56.0 L+₹14.2 L (33.9%)Rejected-Finance | L2 | Rejected-Finance Bidder not quoted L1 rates | |
| 3 | L3₹58.7 L+₹16.9 L (40.6%)Rejected-Finance | L3 | Rejected-Finance Bidder not quoted L1 rates |
| Sl No | Description | Qty | Unit | J B ELECTRICALS L2 | DARSHAN CONSTRUCTION Co. L3 | Monarch Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | PHASE - I
(COMPRISES OF E/M PORTION & B/R PORTION)
(A) E&M PORTION
Dismantling carefully old unserviceable lift from its location (MH CTC) by removing car, panels, pullies, shutters, motors, ropes, cables etc and depositing in AGE E/M (S) Store yard with necessary transportation arrangement and making necessary arrangements to close all openings of the lift well to avoid any accident & preparing the existing lift well in all respect with necessary requirement for installation of new lift all as specified and directed by Engineer-in Charge.
(Note :- Cost of T&P required for dismantling of lift shall deemed to be included in quoated rate.) | 1 | EACH JOB | 1,00,000 ₹1,00,000 | 1,00,000 ₹1,00,000 | 60,000 ₹60,000 Lowest |
| 2.00 | Design, supply, install, testing & commissioning stretcher cum passenger lift (for 26 passengers), speed 1.0 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz conforming to IS-14665, suitable to serve G+03 upper floors with AC variable voltage & variable frequency drive (VVVF) drive complete with all standard accessories, simplex automatic & manual dual controlled operation with/ without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue drive (ARD) system, 3D infrared sensor in full height of door & built in annoucing system (03 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed with following specifications :- | 1 | EACH JOB | 48,68,480 ₹48,68,480 | 43,00,000 ₹43,00,000 | 34,68,900 ₹34,68,900 Lowest |
| 2.01SER. ITEM No. 2.00 Contd.... (a) Type of lift : Stretcher cum passenger lift 26 persons(1768 KG) (b) Rated speed : 1.0 metre/sec (c) Power supply : AC , Three phase ,50 Hz,415 volts (d) Type of control : AC variable voltage & variable frequency (e) Machine : Gearless traction machine installed in machine room (f) Machine room : Located above the top floor Tenderer to inspect the same at site before quoting the bid) (g) Car Size (Inside) : 1550mm(width)X 2450mm depth X 2200 mm height (NOTE : To be assessed by contractor on site before quoting the tender) (h) Car Door : Two-panel , Side opening (j) Landing door at all floor : Automatic Two Panel Telescopic Auto Door Finish, Door in Hairline Finish AISI441 (k) Car Enclosure : Stainless Steel Cabin (Hairline Finish AISI441, 1.0mm) in Hairline Finish with handrail on rear sides, having stainless steel, false ceiling with hairline finish, internal lighting arrangement with LED light fitting complete, internal ventilation system provided with concealed Arial flow/cross flow fan with auto cut off system and grill/wire mesh for protection. (l) Terminal buffer : Metal Special spring buffer (m) Door opening (in side): Clear opening size 1200mm wide x 2000 mm height (n) Car & CWT guide : Machined guide for car 114 mm x 89 mm x 16 mm and for CWT 70 mm x 66 mm x 09 mm (o) Flooring : Aluminum chequered plate 6.0 mm thick | ||||||
| 2.02SER. ITEM No. 2.00 Contd.... (p) Signals : (i)Combined luminous hall buttons with LED hall position indicators at all floor. (ii)LED for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with Luminous buttons in car (stainless steel) (iv) Car direction indicator in car & Landing. (v) Battery operated alarm bell & emergency light(rechargeable) along with suitable maintenance free battery (vi) Overload warning feature in car cabin (display and announcing type both) (vii) Fireman’s switch one Number per lift to be installed at ground floor near landing door. (viii) All singal fixture & car operating panel on stainless steel face plate with hair line finish. | ||||||
| 2.03SER. ITEM No. 2.00 Contd.... (q) Safety devices : (i) Infra and sensor safety edge of door for entire height. (ii) Automatic rescue device (ARD) / automatic landing device to be operating with maintenance free batteries for landing (iii) Built in announcing system (03 Nos. one each in car & near ground floor landing door & one announcing system, press & speak type, 2 way communication with machine room) (iv) The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. (v) Stainless steel hand rail 32 mm dia inside the car cabin (On two sides and rear side) (r) Stops & Opening: 04-04, 0+1+2+3( all Opening on same side). (s) Control operation : Simplex full collective, automatic operation with/ without attendant (t) Hoist way construction existing : Lift Well (RCC wall) (u)Machine Room :Located above the hoist way (v) AC-VVVF drive : Closed loop type. (w) Door drive : AC-VVVF controlled close loop operated, PM motor (x) Counter weight : Guide rail of T- section made out of mild steel counter weight to be on one side/rear of car enclosure as per manufacturer's design. (y) Battery alarm bell and emergency light alongwith luminous button in car. (z) Over load warning features in car with indication and announcing system. | ||||||
| 2.04SER. ITEM No. 2.00 Contd.... (ab) Auto rescue device with maintenance free batteries & auto charging (ac) Microprocessor based controller (ad) Built in voltage monitering & control in control panel with suitable rating and voltage ranges (ae) Landing call registered indicators at all floors (af) Voice annoucing system (ag) Inter phone system - Inside Car to machine room (ah) Fireman's switch at ground floor / main lobby (aj) Car direction in indicator in car and landings (ak) The interior of the car should be provided with a device that audibly indicates the floor lift car has reached and indicates that car entrance / exit door is open / closed (al) Providing MCB TPN DB 4 way way double door with suitable capacity MCB TPN -01 No, MCB 6-32Amps 04 Nos and point wiring in macine room and lift well & 15 Amps socket as required in lift well at each floor complete. | ||||||
| 2.05IMPORTANT NOTES :- 1. Work to be carried out in confirmity with Lift Act & Indian Electricity Act and compliance with IS-732. 2. Contractor quoting bid is requested/adviced to visit the actual site prior to quoting of tender/rates. 3. Dimemsions of Car Size, Shaft overhead and pit has been assessed by the executives on site. However contractor/bidder to measure the same at site and provide undertaking alongwith other documents that the existing structure meets the requirement with respect to lift to be supplied by contractor/bidder. 4. To ensure safety at site & avoid falling hazard, a wall/handrail (as per safety standards of construction/ good engineering practises) on both side of the stepped path is mandatory before start of work. 5. It should be ensured by Garrison Engineer before Commencement of Work that contractor shall have valid Lift License issued by Chief Electrical Inspector Mumbai Maharashtra for Maintenance and erection of Lifts 6. INSPECTION BY GOVT. LIFT INSPECTOR: The lift shall be got inspected by Govt. Lift Inspector for the worthiness certificate after completion of Lift installation. Lift licence shall be suitably framed & put in lift cabin. Charges for inspection or any on this account shall be payable by the contractor and are deemed to be included in the rate quoted. 7. Contractor shall provide 02 (TWO) years warranty against manufacturing defects and also provide services for the First Two Years "Free of Charge" after certified date of completion of PHASE-I. For this purpose contractor may obtain MOU from the Manufacturer and submit the same to EIC / GE for record & reference. 8. Contractor's quoted rate shall deemed to include cost of necessary scaffolding work and T&P required for installation of lift and nothing extra shall be payable to contractor on this account. | ||||||
| 3.00 | S&F in replacement of thermal release adjustable MCCB with each fault protection 100 Amps, 4 Pole, 25 KA with sheet metal enclosure fixed on wall/ board as requireed including all cutting holes in or through wall, making good to walls, including two coat of white/colour washing / distempering etc to the disturbed surface to match the existing all as directed and specified. | 1 | EACH | 8,000 ₹8,000 Lowest | 9,000 ₹9,000 | 14,980 ₹14,980 |
| 4.00 | S&F in replacement of RCCB FP 3 phase 63 A, 100 mA for main power supply with sheet metal enclosure complete all as specified and directed. | 1 | EACH | 3,500 ₹3,500 | 5,000 ₹5,000 | 2,980 ₹2,980 Lowest |
| 5.00 | M&L for earthing complete with galvanised steel earth plate electrode '60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not 'less'than 1.5 metres below normal ground level, connected to 'galvanised iron strip 25x4mm by means of bolts, nuts, check 'nuts and washers of galvanised iron steel riveted to the earth plate. The earth strip protected by provision of GI medium grade pipe 40mm dia including provision of concrete pit in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with 40mm thick RCC cover in 1:2:4 type B1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape, including GI medium grade 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of Phosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point all as specified or indicated and connected to lift machine as indicated 'including testing on completion complete all as specified and directed.
(NOTE :- Cost of galvanised iron strip 25x4mm and GI pipe 40mm bore 'medium grade' for encasing GI strip upto 7.50m length per earthing shall deemed to be included in quoted rate) | 2 | EACH JOB | 12,000 ₹24,000 | 8,000 ₹16,000 | 7,420 ₹14,840 Lowest |
Tender Value
₹60.1 L
EMD Value
₹1.2 L
Closing Date
24 Sept 2025, 6:00 pmClosed
COMMANDER WORKS ENGINEER PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85952 SPL REPAIR / REPLACEMENT AGAINST BER TO EXISTING STRETCHER CUM PASSENGER LIFT (LIFT NO. 09) OF PATIENTS TO CARRY 26 PASSENGER AND COMPREHENSIVE MAINT OF LIFT AT AICTS PUNE UNDER GE (SOUTH) PUNE.
2025_MES_726672_1
85952 CWE PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
123 days
GE (SOUTH) PUNE
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE (SOUTH)
₹1.2 L
Yes
8 Nov 2025
19 Aug 2025
1 Oct 2025
19 Aug 2025
24 Sept 2025
10 Sept 2025
20 Aug 2025 - 26 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .