| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC R O VILL CHEOG TEH THEOG DISTT SHIMLA | ₹2.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.8 L+₹2,857.62 (1.02%)Rejected-Finance R O VERMA NIWAS LOWER CEMETERY SANJAULI SHIMLA | SHIMLA | HIMACHAL PRADESH | 171001 | ₹2.8 L+₹2,857.62 (1.02%) | L2 | Rejected-Finance L2 |
| 3 | L3₹4.0 L+₹1.1 L (40.6%)Rejected-Finance | ₹4.0 L+₹1.1 L (40.6%) | L3 | Rejected-Finance L3 |
| 4 | L4₹4.9 L+₹2.1 L (74.0%)Rejected-Finance HIMACHAL PRADESH HP | MANDI | HIMACHAL PRADESH | 175001 | ₹4.9 L+₹2.1 L (74.0%) | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | MANOHAR LAL VERMA L2 | MADHU SHARMA L4 | BRIJ MOHAN SUMAN L3 | SUNEEL CHAUHAN L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolishing cement concrete manually / by mechanical means disposal of unserviceable materials within all lead complete as per direction of Er-in-Charge | 4 | Per Cum | 600 ₹2,400 | 1,500 ₹6,000 | 500 ₹2,000 | 10 ₹40 Lowest |
| 2.00 | Excavation in earth work and disposal of all excavated earth up to all leads and lifts, disposed earth to be levelled neatly dressed as per direction and to the entire satisfaction of the Engineer-in-Charge | 24.67 | Per Cum | 120 ₹2,960.4 | 430 ₹10,608.1 | 200 ₹4,934 | 10 ₹246.7 Lowest |
| 3.00Providing, laying jointing & testing in trenches centrifugal cast ductile iron (spun) pressure pipes as per IS:8329/2000 Class K-7 duly ISI marked, inside cement mortar lined suitable for tyton (push on joints) for sewer lines including cutting of pipes, chamfering where required (earth work in trenches and jointing of pipes to be measured and paid for separately) including carriage up to the site of work, testing etc., complete as per instructions of the Engineer-in-charge | |||||||
| 3.01 | 150 mm | 90 | Meter | 1,900 ₹1,71,000 | 2,300 ₹2,07,000 | 1,850 ₹1,66,500 Lowest | 1,900 ₹1,71,000 |
| 4.00Providing & fixing in trenches centrifugal cast ductile iron fittings of 9523/2000 class A, series K-12 with inside cement mortar lined suitable for tyton (push on joints) with sewers, such as socketed bends of all degrees, socketed, tees, collars and all other required fittings, including carriage up to the site of work, testing etc., complete as per instructions of the Engineer-in-charge. (earth work in trenches and jointing of fittings to be measured and paid for separately) | |||||||
| 4.01 | 150mm dia double socket DI bend of required degree (90 degree) | 3 | Each | 2,400 ₹7,200 Lowest | 2,500 ₹7,500 | 3,000 ₹9,000 | 3,100 ₹9,300 |
| 4.02 | 45 degree | 2 | Each | 2,000 ₹4,000 Lowest | 2,400 ₹4,800 | 2,800 ₹5,600 | 2,500 ₹5,000 |
| 4.03 | 22.50 degree | 5 | Each | 1,900 ₹9,500 | 2,300 ₹11,500 | 2,600 ₹13,000 | 10 ₹50 Lowest |
| 4.04 | 11.25 degree | 2 | Each | 10 ₹20 Lowest | 2,200 ₹4,400 | 2,200 ₹4,400 | 10 ₹20 Lowest |
| 4.05 | providing and fixing DI Tee 150mm x 150 mm x 100mm | 2 | Each | 3,000 ₹6,000 Lowest | 4,000 ₹8,000 | 3,800 ₹7,600 | 3,100 ₹6,200 |
Tender Value
₹4.9 L
EMD Value
₹9,900
Closing Date
10 Apr 2026, 11:00 amClosed
AGM sewerage division US Club Shimla
AGM sewerage division, SJPNL US Club Shimla
Operation and Maintenance of sewerage Network Restoration of rain damage Providing and laying 150mm dia DI sewer pipe line at above side of St Edward School under STP Lalpani Network
2026_SJPNL_133124_1
SJPNL/sewerage/NIT/14-17
Open Tender
Civil Works
Item Rate
90 days
Shimla
Please refer Tender documents.
8 documents required · 8 mandatory
₹350
₹9,900
6 Aug 2026
2 Apr 2026
10 Apr 2026
2 Apr 2026
10 Apr 2026
2 Apr 2026
2 Apr 2026 - 10 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Demolishing cement concrete manually / by mechanical means disposal of unserviceable materials within all lead complete as per direction of Er-in-Charge | - | Per Cum | - | - |
| - | Excavation in earth work and disposal of all excavated earth up to all leads and lifts, disposed earth to be levelled neatly dressed as per direction and to the entire satisfaction of the Engineer-in-Charge | - | Per Cum | - | - |
| - | Providing, laying jointing & testing in trenches centrifugal cast ductile iron (spun) pressure pipes as per IS:8329/2000 Class K-7 duly ISI marked, inside cement mortar lined suitable for tyton (push on joints) for sewer lines including cutting of pipes, chamfering where required (earth work in trenches and jointing of pipes to be measured and paid for separately) including carriage up to the site of work, testing etc., complete as per instructions of the Engineer-in-charge | - | - | - | - |
| - | 150 mm | 90 | Meter | - | - |
| - | Providing & fixing in trenches centrifugal cast ductile iron fittings of 9523/2000 class A, series K-12 with inside cement mortar lined suitable for tyton (push on joints) with sewers, such as socketed bends of all degrees, socketed, tees, collars and all other required fittings, including carriage up to the site of work, testing etc., complete as per instructions of the Engineer-in-charge. (earth work in trenches and jointing of fittings to be measured and paid for separately) | - | - | - | - |
| - | 150mm dia double socket DI bend of required degree (90 degree) | 3 | Each | - | - |
| - | 45 degree | 2 | Each | - | - |
| - | 22.50 degree | 5 | Each | - | - |
| - | 11.25 degree | 2 | Each | - | - |
| - | providing and fixing DI Tee 150mm x 150 mm x 100mm | 2 | Each | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Form6.pdf
Tender Documents • 0.59 MB
Form8.pdf
Tender Documents • 1.94 MB
conditions.pdf
Tender Documents • 0.36 MB
BOQ_196872.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .