GE (AF) Amla
GE (AF) Amla, Amla Depot Distt Betul (MP) 460553
REPAIR/REPLACEMENT OF CEILING FANS, EXHAUST FAN AND GEYSERS AND SUMMER APPLIANCES AT AFS AMLA
2026_MES_795752_1
8751/E8 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Amla
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹40,000
Yes
26 Oct 2026
26 Oct 2026
18 Nov 2026
26 Oct 2026
16 Nov 2026
9 Nov 2026
26 Oct 2026 - 2 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down ceiling/exhaust fan from any height and of any make / type for servicing & overhauling and replacing of rubber bushing, nuts, bolts, pins etc complete all as specified and as directed. | 25 | Each | - | - |
| 2 | M&L for winding of motor of 1200/1400 mm sweep ceiling fan of any make with super enameled copper winding wire of existing gauge including cutting and getting out old burnt winding, sleeve work, varnishing with E-class insulation varnish, threading, connections with twin core copper flexible wire of size 0.5 Sqmm of length not more than one meter with each fan including white/gray synthetic enamel spray painting of fan and blades after rewinding complete all as specified and directed. | 25 | Each | - | - |
| 3 | S&F in replacement exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding of sweep 250mm complete all as specified & directed.
Note: Old UNSV exhaust fan shall be deposited to MES store yard | 20 | Each | - | - |
| 4 | S&F in replacement ceiling fans complete with blades, down rods and accessories, 230 V, 1200mm sweep min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without remote complete all as specified & directed.
Note: Old UNSV ceiling fan shall be deposited to MES store yard | 150 | Each | - | - |
| 5 | S&F in replacement exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, frame and louvers complete all as specified & directed.
Note: Old UNSV exhaust fan shall be deposited to MES store yard | 25 | Each | - | - |
| 6 | S&F wall mounted fan, made of sturdy engineering plastic, voltage 230 V, 50 Hz, RPM 1350 copper winding of sweep 450 mm including connection as required complete all as specified and directed. | 15 | Each | - | - |
| 7 | Supply and fix louvers shutter section fabricated out of GI Sheet of 22 gauge suitable for 230 / 300 / 450 mm dia exhaust Fan complete all as specified and as directed. | 10 | Each | - | - |
| 8 | S&F of electric water heater 25 Ltr capacity, ABS body with SS inner tank and heating element upto 2 KW capacity, 230 Volts, BEE 5 star rated with all accessories such as safety valve, thermostate, NRV, connection piece etc, fixing on wall through proper nut, bolt, and fastner including electric and water connection complete all as specified and directed.
Note : (i) Srl Number of geyser and 'GE (AF) Amla and CA No. shall be marked on geyser with Red/Black colour paint and cost for the same shall deemed to be included in the quoted unit rate.
(ii) Old UNSV geysers shall be deposited to MES store yard. | 10 | Each | - | - |
| 9 | M & L for Preventive maintenance of storage type electric water heater (Geyser) of capacity 25/35/50 ltrs comprising of the following tasks at different locations of any make.
(a) Inspection of geyser after opening bottom cover plate.
(b) Examine water tightness of storage tank.
(c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.
(d) Check and correct temperature setting of thermostats and functioning of indicator lamp.
(e) Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection cleaning the seat and ensuring that the waste hole is not blocked / chocked including replacing washers / spring etc.
(f) Replacing of fusible plug & ensure it intactness.
(g) Descalling of the immersion type heating element and cleaning with diluted hydrochloric acid or cleaning solution and testing.
(h) Testing of geysers after repairs/maintenance in all respect for proper functioning.
(Note.: Replacement of defective components such thermostat, safety valves fusible, plug, heating elements, PRV dead wt valve etc., will be measured and paid separately under relevant items. | 150 | Each Job | - | - |
| 10 | Supply & fix heating element of geysers of capacity 1.5 KW including rubber washers triangular/ cup type base (ISI marked) complete all as specified and directed. | 25 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
BOQ_892511.xls
BOQ • 1.10 MB
FinalTD.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .