Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹23.1 L+₹3.4 L (17.0%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹24.5 L+₹4.7 L (23.8%)Rejected-Finance HOUSE NO 8 T SHIVPUR MAHADEV JHARKHANDI TUKRA NO 1 P O KUNRAGHAT DISTT GORAKHPUR UTTAR PRADESH 273008 | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273008 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹27.6 L+₹7.8 L (39.5%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹27.6 L+₹7.8 L (39.6%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY AT TECHNICAL AND DOMESTIC AREA AT AF STN GORAKHPUR
2022_MES_557883_1
8944/E8
Open Tender
Civil Works
Item Rate
330 days
GE(AF) GORAKHPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE(AF) GORAKHPUR
₹60,000
Yes
10 Dec 2022
15 Oct 2022
15 Nov 2022
15 Oct 2022
14 Nov 2022
1 Nov 2022
Amount
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable trench complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exec 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exec 50 mtrs and depositing where directed at a level not exec 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
S&F in replacement 80mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Boring of holes horizontally for laying of 80 mm die pipe (minimum depth 1200mm from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply, laying and testing in replacement 10 Sqmm, 3 core XLPE insulated, armored heavy duty electric cable, screened PVC bedded, galvanized steel strip or wire, with aluminum conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
All as per item No. 8 above but for 16 Sqmm, 4 core XLPE cable.
All as per item No. 8 above but for 25 Sqmm, 4 core XLPE cable.
All as per item No. 8 above but for 50 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 70 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 95 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 120 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 150 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 185 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 240 Sqmm, 3.5 core XLPE cable.
Taking out old existing LT UG cable of any size from trench and relaying of LT Cable after repair in trench including excavation, returning, refilling of sand and bricks complete all as specified and directed. Note:- Cable joint will be measured and paid separately under relevant item.
M&L for straight through LT cable joint kit including cutting of faulty cable, preparation and jointing complete of size 16 Sqmm to 50 Sqmm 3.5 core including taking out old joint complete all as specified and directed. Make: Denison/ MS-Seal/ Rotech/3-M
M&L for straight through LT cable joint kit including cutting of faulty cable, preparation and jointing complete of size 70 Sqmm to 150 Sqmm 3.5 core including taking out old joint complete all as specified and directed.
M&L for straight through LT cable joint kit including cutting of faulty cable, preparation and jointing complete of size 185 Sqmm to 240Sqmm 3.5 core including taking out old joint complete all as specified and directed.
Restringing of old ACSR or AAAC conductor of any size and make on LT/HT 9/11 mtr long poles including earth wire, replacement of binding wire and aluminum taps reconnection, street light connections, service connections and binding to insulators with suitable size of new binding wire including pruning and cutting of tree branches 3 mar all around OH LT/HT line and cleaning of creepers around pole complete all as specified and directed. Note: 04/03 Nose of ACSR or AAAC conductor shall be measured as one unit length.
Repairing / replacement of unserviceable MCCBs / MCBs / changeover switch in LT panel / DBs any type including replacing of burnt out lugs, including cutting of burnt cable terminals, prepare and crimping the cable lugs with LT cables in no light / unhealthy light complaints and making serviceable. Work shall also include checking and removal of leakages in neutral and phase in 440 / 220 Volts connection as and when directed. NOTE:- (a)The contractor or his representative will take complaints from MES and rectify the complaint (b) The ladder and T&P as required will be provided by the contractor (c) Risk factor will be the contractor's end (d) Minor items like cable lugs, Insulation tape,nut,bolts etc deemed to be included in rate quoted (e) MCCB will be measured and paid separately in the relevant items.
S&F in replacement MCCB, 160 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB, 200 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB, 250 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB, 400 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB, 630 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 50 KA complete all as specified and directed.
S&F in replacement on load change over switch in steel sheet enclosure, 4 pole of capacity 200 Amps complete all as specified and directed.
S&F in replacement on load change over switch in steel sheet enclosure, 4 pole of capacity 400 Amps complete all as specified and directed.
M&L in replacement for earthling with Galvanized iron earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mar deep below normal GL) with top of earth plate not less than 1.5 mar below GL connected to GI strip of size 25x6 mm connected to earth plate electrode by means of GI nuts, bolts, and washers with and inch, PCC 1:3:6 type C-1 pit with cover of RCC 1:2:4 type B-1 reinforced with welded steel wire fabric not less than 4 Kg per Sam, watering arrangements with 20mm die GI medium grade pipe, GI funnel with GI mesh, filling with mixture of common salt and charcoal, necessary excavation and earth work in any type soil, including test point, testing and commissioning complete all as specified and directed. Note: GI strip up to 7.5 mtr will be included in quoted rate.
Supply only in replacement of bamboo ladder 12 mtr long for day to day complaints like checking fuse wire, insulator, jumper etc by climbing on two pole/four pole structure complete all as specified and directed.
Supply, installation,commisioning and testing out door type LT Junction Box of size 1mtr x 1mtr x 0.6mtr made out of mild steel CRCA sheet of 3.15 mm thick with angle iron frame with canopy top two side ventilators, both front and back open able door hinged, double door shutters with locking arrangement, weather and vermin proof suitable for working on 440 volts AC supply including bus bar chamber and aluminium bus bar of suitable size 4 Nos 400 amps mounted on hygroscopic insulators fixed in separate bus bar chamber including painted with two coats of powder coated paint over a coat of red oxide zinc chromate primer on internal surfaces including provision of lugs and cable glands including necessary PCC foundation complete all as specified and directed.
R.S Enterprises
M/S RAJEEV KUMAR
Unitech India
M/S SHAILZA TRADERS
sri krishna construction
SHARP ENGINEERING WORKS
Instrumentation and Electric Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .