Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | ₹2.8 Cr Quoted ₹3.3 Cr | L1 | Accepted-AOC Qualified |
| 2 | Not Admitted-Fee/PreQual/Technical OFF 215 ASHOKA MALL NEAR RANKA JWELLERS BUND GARDEN ROAD PUNE 411001 | PUNE | PUNE | MAHARASHTRA | 411001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
30 Jul 2021, 3:00 pmClosed
Registrar, SPPU, Pune
Registrar Office, SPPU, Pune-411007
Supply, Installation, Testing And Commissioning Of Lifts at Various Departments in Savitribai Phule Pune University.
2021_UOFP_680484_2
CANo 2021-22/SPPU/EST/EE/ELECT/05
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Campus of Savitribai Phule Pune University
1)Single Similar Lift/Electrical Work Costing Not Less than Rs.50.00 Lakhs ii) Avg. Annual Turnover Lift/Electrical Works Not Less than Rs.211.00 Lakhs.
6 documents required · 6 mandatory
₹7,500
₹2.1 L
22 Oct 2021
13 Jul 2021
31 Jul 2021
13 Jul 2021
30 Jul 2021
13 Jul 2021
13 Jul 2021 - 30 Jul 2021
Amount
Supplying, Installation, Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Placement Cell & Alumni Association building as per the following specifications including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 1.01 Rated capacity :- 6 Passenger (total capacity not less than 408 kg), 1.02 Floors :- G+4 floor (5 Stops / 5Landings), 1.03 Rise/Total Travel - :- 16 meter (Approximate), 1.04 Machine room less lift, 1.05 Rated speed :- 1 m/s, 1.06 Car Size & Dimensions :- suitable for shaft size and capacity, 1.07 Shaft Size :- 1507x1590 mm (+‐ 5 % Deviation as per site condition) , 1.08 Pit Depth : - 1600mm, 1.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation, 1.10 Car Panels :- Stainless steel Hairline Finish, 1.11 Car Flooring :- Stainless steel Chequred Plate, 1.12 Car illumination :-LED lights, 1.13 Car Entrance :- Preferabely central opening / if not possible then Telescopic Opening Power Door in stainless steel Hairline Finish., 1.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 700mm W X 2000mm H Door Operator :- DC Door operator, 1.15 Fire Rated Doors :- Fire Rating 60 Mins., 1.16 Controller Type :- PLC Based or Microprocessor Based, 1.17 Drive :- VF Regenrative (Closed Loop), 1.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels., 1.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS , 1.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system,1.21 Mirror on the rear side of the wall,1.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder..,1.23 Direction & Position Indicator of Car,1.24 Emergency Alarm System,1.25 Hands Free Press and Speak Intercom (two way),1.26 Full height Infra red curtains,1.27 Pit ladder,1.28 Signal Fixtures in Stainless steel finish,1.29 Emergency light system,1.30 Micro movement LED Based buttons,1.31 .minimum +10 % to -10% capacity to withstand the voltage fluctuation,1.32 Automatic phase reversal,1.33 Necessary Manual Rescue Device arrangement,1.34 Stainless Steel Button with LED Lights,1.35 Landing announcement System.
Supplying, Installation, Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Jayakar Library building as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 2.01 Rated capacity :- 6 Passenger (total capacity not less than 408 kg),2.02 Floors :- G+5 floor (6 Stops / 6 Landings),2.03 Rise/Total Travel - :- 18 meter (Approximate),2.04 Machine room less lift,2.05 Rated speed :- 1 m/s, 2.06 Car Size & Dimensions :- suitable for shaft size and capacity , 2.07 Shaft Size :- 1600x1530 mm (+‐ 5 % Deviation as per site condition) , 2.08 Pit Depth : - 1600mm, 2.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation, 2.10 Car Panels :- Stainless steel Hairline Finish, 2.11 Car Flooring :- Stainless steel Chequred Plate, 2.12 Car illumination :-LED lights, 2.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish., 2.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 700mm W X 2000mm H Door Operator :- DC Door operator, 2.15 Fire Rated Doors :- Fire Rating 60 Mins., 2.16 Controller Type :- PLC Based or Microprocessor Based, 2.17 Drive :- VF Regenrative (Closed Loop), 2.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels. , 2.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS, 2.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system, 2.21 Mirror on the rear side of the wall, 2.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder., 2.23 Direction & Position Indicator of Car, 2.24 Emergency Alarm System, 2.25 Hands Free Press and Speak Intercom (two way), 2.26 Full height Infra red curtains, 2.27 Pit ladder, 2.28 Signal Fixtures in Stainless steel finish, 2.29 Emergency light system, 2.30 Micro movement LED Based buttons, 2.31 .minimum +10 % to -10% capacity to withstand the voltage fluctuation, 2.32 Automatic phase reversal, 2.33 Necessary Manual Rescue Device arrangement, 2.34 Stainless Steel Button with LED Lights, 2.35 Landing announcement System.
Supplying, Installation , Testing and commissioning of 100kg Capacity Dumb Waiter lift in Library Building at Social Sciences - II, G+3 floors , 4 stops and 4 landings ,approximate travel up to 12-18 meter , Lift Duty Machine installed Above the Hoist way, 1 Nos. 6mm Dia. Lift Duty Traction Rope, 1.0 m/s speed, UP/DN Car direction indicators on every Landing, Floor Position indications, Door Open Bell, Call register Indication, 415V / AC, 3 Phase, 50 Hz Power Supply, Stainless Steel – Hairline Finish Car Door with opening 550 mm X 900 mm, Stainless Steel - Hairline Finish Cabin Finish, Stainless Steel Chequred Plate Flooring, Regular SS Finish LOP,V,Automatic Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS,Necessary Manual Rescue Device arrangement,Landing announcement System,Full height Infra red curtains. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any).Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder.
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at International Boys Hostel building as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 4.01 Rated capacity :- 8 Passenger (total capacity not less than 544 kg)., 4.02 Floors :- G+5 floors (6 Stops / 6 Landings)., 4.03 Rise/Total Travel - :- 18 meter (Approximate), 4.04 Machine room less lift, 4.05 Rated speed :- 1 m/s, 4.06 Car Size & Dimensions :- suitable for shaft size and capacity, 4.07 Shaft Size:- 1800x1800 mm (+‐ 5 % Deviation as per site condition) , 4.08 Pit Depth : - 1600mm, 4.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation, 4.10 Car Panels :- Stainless steel Hairline Finish, 4.11 Car Flooring :- Stainless steel Chequred Plate, 4.12 Car illumination :-LED lights, 4.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish., 4.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 800mm W X 2000mm H Door Operator :- DC Door operator, 4.15 Fire Rated Doors :- Fire Rating 60 Mins., 4.16 Controller Type :- PLC Based or Microprocessor Based, 4.17 Drive :- VF Regenrative (Closed Loop), 4.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels., 4.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS, 4.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system, 4.21 Mirror on the rear side of the wall, 4.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder..,4.23 Direction & Position Indicator of Car, 4.24 Emergency Alarm System, 4.25 Hands Free Press and Speak Intercom (two way), 4.26 Full height Infra red curtains, 4.27 Pit ladder, 4.28 Signal Fixtures in Stainless steel finish, 4.29 Emergency light system, 4.30 Micro movement LED Based buttons, 4.31 minimum +10 % to -10% capacity to withstand the voltage fluctuation, 4.32 Automatic phase reversal, 4.33 Necessary Manual Rescue Device arrangement, 4.34 Stainless Steel Button with LED Lights, 4.35 Landing announcement System.,
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Women's Hostel building building as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 5.01 Rated capacity :- 8 Passenger (total capacity not less than 544 kg), 5.02 Floors :- G+4 floors (5 Stops / 5 Landings) , 5.03 Rise/Total Travel - :- 20 meter (Approximate) , 5.04 Machine room less lift, 5.05 Rated speed :- 1 m/s , 5.06 Car Size & Dimensions :- suitable for shaft size and capacity, 5.07 Shaft Size:- 1800x1800 mm, 5.08 Pit Depth : - 1600mm, 5.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation (+‐ 5 % Deviation as per site condition) , 5.10 Car Panels :- Stainless steel Hairline Finish, 5.11 Car Flooring :- Stainless steel Chequred Plate, 5.12 Car illumination :-LED lights, 5.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish. , 5.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 800mm W X 2000mm H Door Operator :- DC Door operator , 5.15 Fire Rated Doors :- Fire Rating 60 Mins. , 5.16 Controller Type :- PLC Based or Microprocessor Based, 5.17 Drive :- VF Regenrative (Closed Loop) , 5.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels. , 5.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS, 5.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system, 5.21 Mirror on the rear side of the wall, 5.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder. , 5.23 Direction & Position Indicator of Car, 5.24 Emergency Alarm System, 5.25 Hands Free Press and Speak Intercom (two way) , 5.26 Full height Infra red curtains, 5.27 Pit ladder, 5.28 Signal Fixtures in Stainless steel finish, 5.29 Emergency light system, 5.30 Micro movement LED Based buttons , 5.31 .minimum +10 % to -10% capacity to withstand the voltage fluctuation, 5.32 Automatic phase reversal, 5.33 Necessary Manual Rescue Device arrangement, 5.34 Stainless Steel Button with LED Lights, 5.35 Landing announcement System. ,
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Ladies Hostel Building for Competitive Exam as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 6.01 Rated capacity :- 8 Passenger (total capacity not less than 544 kg), 6.02 Floors :- G+5 floors (6 Stops / 6 Landings), 6.03 Rise/Total Travel - :- 18 meter (Approximate), 6.04 Machine room less lift, 6.05 Rated speed :- 1 m/s , 6.06 Car Size & Dimensions :- suitable for shaft size and capacity, 6.07 Shaft Size:- 1820x1820 mm (+‐ 5 % Deviation as per site condition) , 6.08 Pit Depth : - 1600mm , 6.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation, 6.10 Car Panels :- Stainless steel Hairline Finish, 6.11 Car Flooring :- Stainless steel Chequred Plate, 6.12 Car illumination :-LED lights, 6.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish. 6.14 Door Safety :- Full Height Infra red Safety Curtains.Door Opening - 800mm W X 2000mm H Door Operator :- DC Door operator, 6.15 Fire Rated Doors :- Fire Rating 60 Mins., 6.16 Controller Type :- PLC Based or Microprocessor Based, 6.17 Drive :- VF Regenrative (Closed Loop), 6.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels., 6.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS, 6.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system, 6.21 Mirror on the rear side of the wall, 6.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder. 6.23 Direction & Position Indicator of Car, 6.24 Emergency Alarm System, 6.25 Hands Free Press and Speak Intercom (two way), 6.26 Full height Infra red curtains, 6.27 Pit ladder, 6.28 Signal Fixtures in Stainless steel finish, 6.29 Emergency light system, 6.30 Micro movement LED Based buttons, 6.31 minimum +10 % to -10% capacity to withstand the voltage fluctuation, 6.32Automatic phase reversal, 6.33 Necessary Manual Rescue Device arrangement, 6.34 Stainless Steel Button with LED Lights, 6.35 Landing announcement System.,
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Chemistry Department Extension Building building as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 7.01 Rated capacity :- 8 Passenger (total capacity not less than 544 kg) 7.02 Floors :- G+5 floors (6 Stops / 6 Landings) 7.03 Rise/Total Travel - :- 18 meter (Approximate) 7.04 Machine room less lift 7.05 Rated speed :- 1 m/s 7.06 Car Size & Dimensions :- suitable for shaft size and capacity 7.07 Shaft Size:- 1900x1900 mm (+‐ 5 % Deviation as per site condition) , 7.08 Pit Depth : - 1600mm 7.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation 7.10 Car Panels :- Stainless steel Hairline Finish 7.11 Car Flooring :- Stainless steel Chequred Plate 7.12 Car illumination :-LED lights 7.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish. 7.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 800mm W X 2000mm H Door Operator :- DC Door operator 7.15 Fire Rated Doors :- Fire Rating 60 Mins. 7.16 Controller Type :- PLC Based or Microprocessor Based 7.17 Drive :- VF Regenrative (Closed Loop) 7.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels. 7.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS 7.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system 7.21 Mirror on the rear side of the wall 7.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder.. 7.23 Direction & Position Indicator of Car 7.24 Emergency Alarm System 7.25 Hands Free Press and Speak Intercom (two way) 7.26 Full height Infra red curtains 7.27 Pit ladder 7.28 Signal Fixtures in Stainless steel finish 7.29 Emergency light system 7.30 Micro movement LED Based buttons 7.31 minimum +10 % to -10% capacity to withstand the voltage fluctuation 7.32 Automatic phase reversal 7.33 Necessary Manual Rescue Device arrangement 7.34 Stainless Steel Button with LED Lights 7.35 Landing announcement System.
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Gents Hostel Building Competitive Exam as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 8.01 Rated capacity :- 8 Passenger (total capacity not less than 544 kg) 8.02 Floors :- G+5 floors (6 Stops / 6 Landings) 8.03 Rise/Total Travel - :- 18 meter (Approximate) 8.04 Machine room less lift 8.05 Rated speed :- 1 m/s 8.06 Car Size & Dimensions :- suitable for shaft size and capacity 8.07 Shaft Size:- 1820x1820 mm (+‐ 5 % Deviation as per site condition) 8.08 Pit Depth : - 1600mm 8.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation 8.10 Car Panels :- Stainless steel Hairline Finish 8.11 Car Flooring :- Stainless steel Chequred Plate 8.12 Car illumination :-LED lights 8.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish. 8.14 Door Safety :- Full Height Infra red Safety Curtains Door Opening - 800mm W X 2000mm H Door Operator :- DC Door operator 8.15 Fire Rated Doors :- Fire Rating 60 Mins. 8.16 Controller Type :- PLC Based or Microprocessor Based 8.17 Drive :- VF Regenrative (Closed Loop) 8.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels. 8.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS 8.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system 8.21 Mirror on the rear side of the wall 8.22Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder.. 8.23 Direction & Position Indicator of Car 8.24 Emergency Alarm System 8.25 Hands Free Press and Speak Intercom (two way) 8.26 Full height Infra red curtains 8.27 Pit ladder 8.28 Signal Fixtures in Stainless steel finish 8.29 Emergency light system 8.30 Micro movement LED Based buttons 8.31 .minimum +10 % to -10% capacity to withstand the voltage fluctuation 8.32 Automatic phase reversal 8.33 Necessary Manual Rescue Device arrangement 8.34 Stainless Steel Button with LED Lights 8.35 Landing announcement System
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Academic Staff College Building building as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 9.01 Rated capacity :- 13 Passenger (total capacity not less than 884 kg) 9.02 Floors :- G+5 floors (6 Stops / 6 Landings) 9.03 Rise/Total Travel - :- 18 meter (Approximate) 9.04 Machine room less lift 9.05 Rated speed :- 1 m/s 9.06 Car Size & Dimensions :- suitable for shaft size and capacity 9.07 Shaft Size:- 2400x2400 mm (+‐ 5 % Deviation as per site condition) 9.08 Pit Depth : - 1600mm 9.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation 9.10 Car Panels :- Stainless steel Hairline Finish 9.11 Car Flooring :- Stainless steel Chequred Plate 9.12 Car illumination :-LED lights 9.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish. 9.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 900mm W X 2000mm H Door Operator :- DC Door operator 9.15 Fire Rated Doors :- Fire Rating 60 Mins. 9.16 Controller Type :- PLC Based or Microprocessor Based 9.17 Drive :- VF Regenrative (Closed Loop) 9.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels. 9.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS 9.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system 9.21 Mirror on the rear side of the wall 9.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder.. 9.23 Direction & Position Indicator of Car 9.24 Emergency Alarm System 9.25 Hands Free Press and Speak Intercom (two way) 9.26 Full height Infra red curtains 9.27 Pit ladder 9.28 Signal Fixtures in Stainless steel finish 9.29 Emergency light system 9.30 Micro movement LED Based buttons 9.31 .minimum +10 % to -10% capacity to withstand the voltage fluctuation 9.32 Automatic phase reversal 9.33 Necessary Manual Rescue Device arrangement 9.34 Stainless Steel Button with LED Lights 9.35 Landing announcement System.
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Physical Education Department Building as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 10.01 Rated capacity :- 8 Passenger (total capacity not less than 544 kg) 10.02 Floors :- G+3 floors (4 Stops / 4 Landings) 10.03 Rise/Total Travel - :- 12 meter (Approximate) 10.04 Machine room less lift 10.05 Rated speed :- 1 m/s 10.06 Car Size & Dimensions :- suitable for shaft size and capacity 10.07 Shaft Size:- 1900x1785 mm(+‐ 5 % Deviation as per site condition) ,10.08 Pit Depth : - 1600mm 10.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation 10.10 Car Panels :- Stainless steel Hairline Finish 10.11 Car Flooring :- Stainless stell Chequred Plate 10.12 Car illumination :-LED lights 10.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish. 10.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 800mm W X 2000mm H Door Operator :- DC Door operator 10.15 Fire Rated Doors :- Fire Rating 60 Mins. 10.16 Controller Type :- PLC Based or Microprocessor Based 10.17 Drive :- VF Regenrative (Closed Loop) 10.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels. 10.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS 10.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system 10.21 Mirror on the rear side of the wall 10.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder.. 10.23 Direction & Position Indicator of Car 10.24 Emergency Alarm System 10.25 Hands Free Press and Speak Intercom (two way) 10.26 Full height Infra red curtains 10.27 Pit ladder 10.28 Signal Fixtures in Stainless steel finish 10.29 Emergency light system 10.30 Micro movement LED Based buttons 10.31 .minimum +10 % to -10% capacity to withstand the voltage fluctuation 10.32 Automatic phase reversal 10.33 Necessary Manual Rescue Device arrangement 10.34 Stainless Steel Button with LED Lights 10.35 Landing announcement System.
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at Library Building at Social Sciences - II as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 11.01 Rated capacity :- 8 Passenger (total capacity not less than 544 kg) 11.02 Floors :- G+3 floors (4 Stops / 4 Landings) 11.03 Rise/Total Travel - :- 12 meter (Approximate) 11.04 Machine room less lift 11.05 Rated speed :- 1 m/s 11.06 Car Size & Dimensions :- suitable for shaft size and capacity 11.07 Shaft Size:- 1800x1800 mm (+‐ 5 % Deviation as per site condition) , 11.08 Pit Depth : - 1600mm 11.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation 11.10 Car Panels :- Stainless steel Hairline Finish 11.11 Car Flooring :- Stainless stell Chequred Plate 11.12 Car illumination :-LED lights 11.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish. 11.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 800mm W X 2000mm H Door Operator :- DC Door operator 11.15 Fire Rated Doors :- Fire Rating 60 Mins. 11.16 Controller Type :- PLC Based or Microprocessor Based 11.17 Drive :- VF Regenrative (Closed Loop) 11.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels. 11.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS 11.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system11.21 Mirror on the rear side of the wall 11.22Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder.. 11.23 Direction & Position Indicator of Car 11.24 Emergency Alarm System 11.25 Hands Free Press and Speak Intercom (two way) 11.26 Full height Infra red curtains 11.27 Pit ladder 11.28 Signal Fixtures in Stainless steel finish 11.29 Emergency light system 11.30 Micro movement LED Based buttons 11.31 .minimum +10 % to -10% capacity to withstand the voltage fluctuation 11.32 Automatic phase reversal 11.33 Necessary Manual Rescue Device arrangement 11.34 Stainless Steel Button with LED Lights 11.35 Landing announcement System.
Supplying, Installation , Testing and commissioning of Electric Passenger Lift with Power operated Automatic doors at CAP Bhavan Building as per the following specifications. including applying for and obtaining necesaary licenses from authorities ( Government fees will be paid by university if any). 12.01 Rated capacity :- 8 Passenger (total capacity not less than 544 kg) 12.02 Floors :- G+4 floors (5 Stops / 5 Landings) 12.03 Rise/Total Travel - :- 15meter (Approximate) 12.04 Machine room less lift 12.05 Rated speed :- 1 m/s 12.06 Car Size & Dimensions :- suitable for shaft size and capacity 12.07 Shaft Size:- 1800x1800 mm (+‐ 5 % Deviation as per site condition) ,12.08 Pit Depth : - 1600mm 12.09 Car Ceilling :- Stainless steel Hairline Finish with exhaust fan for ventilation 12.10 Car Panels :- Stainless steel Hairline Finish 12.11 Car Flooring :- Stainless stell Chequred Plate 12.12 Car illumination :-LED lights 12.13 Car Entrance :- Central Opening Power Door in stainless steel Hairline Finish. 12.14 Door Safety :- Full Height Infra red Safety Curtains. Door Opening - 800mm W X 2000mm H Door Operator :- DC Door operator 12.15 Fire Rated Doors :- Fire Rating 60 Mins. 12.16 Controller Type :- PLC Based or Microprocessor Based 12.17 Drive :- VF Regenrative (Closed Loop) 12.18 Hand Rails :- Stainless Steel Mirror Finish Hand rails on the rear car panels. 12.19 Automatic rescue device with 12AH 6 Nos. of battery with adequate rating UPS 12.20 Power Supply - 3 phase, 415 Volt, 50 Hz. 4 wire system12.21 Mirror on the rear side of the wall 12.22 Incoming cable from electrical panel room to lift shaft duct, earthing pits, earthing strip/cable up to lift shaft duct will be provided by university. Further provision i.e. bulkheads, DB'S, scaffholding, necessary protecting electrical devices MCB, MCCB, RCCB etc. complete is in the scope of successful bidder.. 12.23 Direction & Position Indicator of Car 12.24 Emergency Alarm System 12.25 Hands Free Press and Speak Intercom (two way) 12.26 Full height Infra red curtains 12.27 Pit ladder 12.28 Signal Fixtures in Stainless steel finish 12.29 Emergency light system 12.30 Micro movement LED Based buttons 12.31 minimum +10 % to -10% capacity to withstand the voltage fluctuation 12.32 Automatic phase reversal 12.33 Necessary Manual Rescue Device arrangement 12.34 Stainless Steel Button with LED Lights 12.35 Landing announcement System.
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -1 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -2 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -3 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -4 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -5 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) Note : Applicable for 2 Nos Lift A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -6 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) Note : Applicable for 2 Nos Lift A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -7 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) Note : Applicable for 2 Nos Lift A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -8 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) Note : Applicable for 2 Nos Lift A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -9 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -10 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -11 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
Additional Full Comprehensive Maintenance Including all parts and labour for Item No -12 (Period of maintenance and support is 5 years which will commence after successful completion of defect liability period of 24 months) Note : Applicable for 4 Nos Lift A) Year 1
B) Year 2
C) Year 3
D) Year 4
E) Year 5
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .