Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAdmitted-Finance | ₹10.9 L | L1 | Admitted-Finance |
| 2 | L2₹16.3 L+₹5.4 L (49.8%)Admitted-Finance | ₹16.3 L+₹5.4 L (49.8%) | L2 | Admitted-Finance |
| 3 | L3₹17.8 L+₹6.9 L (62.9%)Admitted-Finance | ₹17.8 L+₹6.9 L (62.9%) | L3 | Admitted-Finance |
| 4 | L4₹18.1 L+₹7.2 L (65.6%)Admitted-Finance FLAT NO 93 POCKET 03 SECTOR 11 DWARKA NEW DELHI 110 075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹18.1 L+₹7.2 L (65.6%) | L4 | Admitted-Finance |
| 5 | L5₹18.1 L+₹7.2 L (65.7%)Admitted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹18.1 L+₹7.2 L (65.7%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Prakash Enterprises L6 | Commercial Traders L5 | M/S PRADEEP ENTERPRISES L4 | OM ASSOCIATES L2 | V.K. Enterprises L8 | YANSHIKA SECURITY SERVICES L1 | M P TYAGI ENGINEERS AND CONTRACTORS L7 | PARAS ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out hard/Dense soil complete all as specified and as directed for foundation of stay, laying of cable etc complete all as specified and directed. | 10 | Cubic Meter | 200 ₹2,000 | 85 ₹850 Lowest | 500 ₹5,000 | 199 ₹1,990 | 300 ₹3,000 | 105 ₹1,050 | 99 ₹990 | 475 ₹4,750 |
| 2.00 | Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc, complete all as specified and as directed. | 120 | Cubic Meter | 200 ₹24,000 | 120 ₹14,400 | 100 ₹12,000 | 129 ₹15,480 | 130 ₹15,600 | 95 ₹11,400 | 49 ₹5,880 Lowest | 265 ₹31,800 |
| 3.00 | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed. | 85 | Cubic Meter | 200 ₹17,000 | 25 ₹2,125 | 50 ₹4,250 | 19 ₹1,615 | 70 ₹5,950 | 20 ₹1,700 | 9 ₹765 Lowest | 150 ₹12,750 |
| 4.00 | Removal of excavated surplus soil to a distance n exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed. | 45 | Cubic Meter | 200 ₹9,000 | 30 ₹1,350 | 60 ₹2,700 | 19 ₹855 | 70 ₹3,150 | 20 ₹900 | 9 ₹405 Lowest | 280 ₹12,600 |
| 5.00 | Material and Labour for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and 18cm punnd thickness shall be paid complete all as specified and as directed. | 11.7 | Cubic Meter | 200 ₹2,340 | 300 ₹3,510 | 600 ₹7,020 | 249 ₹2,913.3 | 600 ₹7,020 | 200 ₹2,340 | 99 ₹1,158.3 Lowest | 1,550 ₹18,135 |
| 6.00 | Supply and laying reinforced precast concreate cable cover, HV , flat size 450mm x 230mm x 50 mm for HT cable protection complete all as specified and as directed. | 1,150 | EACH | 20 ₹23,000 | 22 ₹25,300 | 12 ₹13,800 | 19 ₹21,850 | 26 ₹29,900 | 2.5 ₹2,875 | 0.99 ₹1,138.5 Lowest | 140 ₹1,61,000 |
| 7.00 | Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregates for repairing / filling in road cuts/ hard standing etc all as specified and as directed. | 1 | Cubic Meter | 5,000 ₹5,000 | 3,000 ₹3,000 | 3,000 ₹3,000 | 1,999 ₹1,999 | 4,000 ₹4,000 | 1,200 ₹1,200 | 999 ₹999 Lowest | 4,500 ₹4,500 |
| 8.00 | Material and Labour complete for drilling hole with trenchless technology under hard standing /road for laying of pipe for protection of cable etc by means of manual booklet and without disturbing the top surface or cutting and making good the disturbed surface to the existing if any, complete all as specified and directed. | 12 | Running Meter | 300 ₹3,600 | 500 ₹6,000 | 500 ₹6,000 | 299 ₹3,588 | 800 ₹9,600 | 150 ₹1,800 | 99 ₹1,188 Lowest | 350 ₹4,200 |
| 9.00 | Supply and laying GI tube light grade 100 mm bore pipe with ISI marked fittings complete all as specified and directed. | 6 | Running Meter | 300 ₹1,800 | 450 ₹2,700 | 500 ₹3,000 | 449 ₹2,694 | 1,100 ₹6,600 | 200 ₹1,200 | 199 ₹1,194 Lowest | 650 ₹3,900 |
| 10.00 | Supply and Fix GI Tubing light grade of size 80mm bore for LT cable protection including clamps, nut, bolts and washer etc complete all as specified and as directed. | 6 | Running Meter | 300 ₹1,800 | 275 ₹1,650 | 400 ₹2,400 | 299 ₹1,794 | 770 ₹4,620 | 190 ₹1,140 | 149 ₹894 Lowest | 575 ₹3,450 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
19 Aug 2026, 6:00 pmClosed
CWE (AF) TUGHLAKABAD
Headquarters CWE AF Tughlakabad, Air Force Station, Tughlakabad, PO Sangam Vihar, New Delhi 110 080
REPAIR/ MAINT OF HT DISTRIBUTION SYSTEM, HT JOINT CABLE AND MAINT OF TRANSFORMER AT SEKHON VIHAR UNDER GE (AF) GURGAON NO. 1
2026_MES_780047_1
CWE/TKD/GUR/TOKEN-38 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PALAM UNDER GE AF GURGAON NO 1
As per NIT.
7 documents required · 7 mandatory
₹500
GE (AF) GURGAON NO. 1
₹50,000
Yes
16 Sept 2026
22 Jul 2026
21 Aug 2026
22 Jul 2026
19 Aug 2026
5 Aug 2026
23 Jul 2026 - 30 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out hard/Dense soil complete all as specified and as directed for foundation of stay, laying of cable etc complete all as specified and directed. | 10 | Cubic Meter | - | - |
| 2 | Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc, complete all as specified and as directed. | 120 | Cubic Meter | - | - |
| 3 | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed. | 85 | Cubic Meter | - | - |
| 4 | Removal of excavated surplus soil to a distance n exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed. | 45 | Cubic Meter | - | - |
| 5 | Material and Labour for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and 18cm punnd thickness shall be paid complete all as specified and as directed. | 11.7 | Cubic Meter | - | - |
| 6 | Supply and laying reinforced precast concreate cable cover, HV , flat size 450mm x 230mm x 50 mm for HT cable protection complete all as specified and as directed. | 1,150 | EACH | - | - |
| 7 | Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregates for repairing / filling in road cuts/ hard standing etc all as specified and as directed. | 1 | Cubic Meter | - | - |
| 8 | Material and Labour complete for drilling hole with trenchless technology under hard standing /road for laying of pipe for protection of cable etc by means of manual booklet and without disturbing the top surface or cutting and making good the disturbed surface to the existing if any, complete all as specified and directed. | 12 | Running Meter | - | - |
| 9 | Supply and laying GI tube light grade 100 mm bore pipe with ISI marked fittings complete all as specified and directed. | 6 | Running Meter | - | - |
| 10 | Supply and Fix GI Tubing light grade of size 80mm bore for LT cable protection including clamps, nut, bolts and washer etc complete all as specified and as directed. | 6 | Running Meter | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
CompleteTenderDocuments.pdf
Tender Documents • 0.57 MB
BOQ_873742.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .