Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable rate | |
| 2 | L2₹17.9 L+₹72,592 (4.23%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDER | |
| 3 | L3₹18.8 L+₹1.7 L (9.79%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDER | |
| 4 | L4₹19.7 L+₹2.5 L (14.6%)Rejected-Finance SR NO 281 3 7 ANAND NAGAR NEAR DHANORI JAKAT NAKA LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance NOT THE LOWEST TENDER | |
| 5 | L5₹20.9 L+₹3.8 L (22.0%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹47,000
Closing Date
5 Jun 2024, 6:00 pmClosed
CWE Khadki
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
SPECIAL REPAIR TO THE OFFICE BUILDING OF ADG (D AND C) PUNE UNDER GE(CENTRAL) KHADKI
2024_MES_652625_1
CWE/KKE/TOKEN-68 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
CWE Khadki
As per Tender documents
6 documents required · 6 mandatory
₹500
GE CENTRAL KHADKI
₹47,000
Yes
6 Sept 2024
7 May 2024
7 Jun 2024
7 May 2024
5 Jun 2024
22 May 2024
8 May 2024 - 14 May 2024
Amount
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each complete all as specified and directed.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc. 1.50 Sqm and n.exc 4.00 Sqm each complete all as specified and directed.
Taking down Shutters of any description exc 1 sqm but n exc 2 sqm each complete all as specified and as directed by Engr-in-charge.
Dismantling floor hearth or wall tiling incl cement mortar bedding but not backing and removing rubbish off the premises complete all as specified as specified and directed
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing rubbish off the premises complete all as specified and as directed by Engr-in-charge.
M&L for 20mm thick Granite (of any type) slab machine cut, in Cill,Jambs, soffits etc., of windows laid over 10mm thick cement screed bed in CM 1:4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, bullnosed and polishing complete all as directed.
M&L for complete removal of existing surface, preparation of old painted surfaces of walls and applying two coats of plastic emulsion paint over a coat of primer on wall surfaces complete all as specified and directed.
M&L for complete removal of existing treatment of old surfaces and applying two coats of weather proof acrylic exterior paint (100%) Acrylic over one coat of self primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and directed by Engr-in-Charge.
Taking down cement or cement lime plaster on brick, PCC block masonry or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed by Engineer- in-charge.
M & L for 10 mm thick plastering on fair faces of brickwork or concrete surface in CM 1:6 finished even and smooth without using extra cement all as specified and directed by Engr-in-Charge.
M&L providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM 1:3 mixing with liquid water proofing compound all as per manufacturers instructions, finishing surface even and fair without using extra cement complete all as specified and as directed by Engr-in-charge.. Note: Liquid WPC shall be measured & paid separately under relevant item of this BOQ.
Supply only Liquid water proofing compound complete etc. all as specified and as directed.
M&L for 75mm thick cement concrete M-10 grade (Nominal Mix) using 40mm graded stone aggregate as in sub base floor and paving etc. including necessary form work etc. complete all as specified and as directed by Eng.-in-charge.
Hacking out old broken glass, (any thickness, size , quality or description) metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new one all specified and directed
Supply only sheet glass, 3mm thick , ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane , all as specified and directed.
S & F 35mm thick factory made IInd hard wood plain , framed , panelled shutter ( 2 panel ) with lock rail and panel commercial ply or 12 mm veneered particle board with of 9 mm B.W.P commercial veneering on both faces.The size of rail and stile as per IS:1003 ( part-I ), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F aluminium powder coated window sliding type (3 track) with frame size 100x35x1.2mm and shutter 39.40x17.70x1.2mm with two glass shutter & one mesh shutter incl necessary jointing cleats cleats, glazing clips, rubber packing, powder coated aluminium snap beading screws with 4mm plain float glass & 0.56 mm dia SS wire mesh, fittings etc. including taking down old steel window of complete all as specified.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube, supplying & fixing in opening as per specification & drawing
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail. MS frame shall be coverd with heat moulded plain colour PVC 'C' channel having a PVC sheet strys of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail of either side and as gap insert for top rail and bottom rail panelling of plain colour PVC to be fitted in the ms frame welded/ sealed in the stiles and rail with suitable PVC sheet and loading and jointed together with solvent cement, supplying and fixing in the frame at site all as directed by Engineer -in -charge.
S & F 125 mm size extruded aluminium alloy handles, fabricated type anodised.
S & F aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 150mm.
S & F aluminium alloy , anodised , sliding door bolt with hasp , staple ( bolt type ) & fixing clips of sheet, cast or extruded section & fixing bolts & sliding bolts of extruded section or cast aluminium alloy & fixed - length of bolt 200 mm
S&F 100 mm mild steel butt hinges medium weight, cold rolled mild steel and fixed all as specified and as directed by Engr-in-charge.
M&L painting to wooden surfaces of any description over 10 cm width or girth including preparation of new or untreated surface and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engr-in-charge.
M&L colour Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile and laid over & including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engr-in-charge.
M&L colour Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile and laid over & including15 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engr-in-charge.
All as per item No 27 above but as in dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tile and laid over & including 10mm thick backing coat in CM 1:4 all as specified and as directed by Engr-in-charge.
S & F Vitrified ceramic coloured tiles 8mm to10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile and laid over & including15 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engr-in-charge.
All as per item No 29 above but in skirting/dado laid over including 10mm thick rendering as in backing coat in CM 1:4 complete all as specified and as directed by Engr-in-charge.
M & L for rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finishing even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed by Engineer-in-charge
M&L rendering 10 mm thick in cement mortar 1:4 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of newly plastered surface and applying three coats of white wash on ceiling complete all as specified and as directed by Engineer-in-charge
M&L for preparation of old plastered surface and applying two coats of white wash on wall complete all as specified and as directed by Engineer-in-charge
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed by Engr-in-Charge.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Wash basins, vitreous China (flat back or angle back type) size 580X450mm, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing and supply of waste pipe all as specified and as directed by Engr-in-Charge.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe etc. complete and making good to floor all as specified and as directed by Engr-in-charge.
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe)
S&F in repairs Plastic water closet seat cover (any colour) closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device all as specified and as directed by Engr-in-charge.
S & F in repair PVC valve less syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and as directed by Engr-in-charge.
S & F in repair Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and as directed by Engr-in-charge.
S&F in repairs 15 mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified.
S&F in repairs 15mm dia fancy type Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F in repairs 15mm dia bore fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F in repairs CP two way bib taps screwed for iron pipe 15 mm bore and fixed necessary fitting with and incl PVC connection all as specified and as directed by Engr-in-charge.
S&F in repairs PVC waste outlet pipe 32/40mm dia for WHB complete all as specified and directed. all as specified and as directed by Engr-in-charge.
S & F in repairs PVC connection of 600 mm length, suitable for 15 mm bore pipe with PTMT nuts, all as specified and as directed by Engr-in-charge.
S&F in repair tubular towel rail 20mm dia, D type 60cm long between flanges brass chromium plated, all as specified and as directed by Engr-in-charge.
Dismantling wall and ceiling boards (Fiber pulp, insulation etc. or insulation boards any thickness including cover fillets.
S&F E-board 'Everest' make or equivalent as approved by GE of size 600x600x4mm thick white prelaminated sett embossed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers of GI wire 2mm dia to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm centre to form 1200x600mm modules cross tee longer than 600mm to be supported independently. 600x600mm modules to be formed by fitting 600mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacture instruction, including taking down wall/ceiling boards(fibre, pulp insulation etc.) or insulation boards any thickness incl fillets complete all as directed.
S &F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair Harrison rails, of anodised aluminium alloy with fixing brackets, stops, rollers etc complete all as specified and as directed .
Dismantling fencing, wire mesh any type complete all as specified and directed by Engr in Charge
Dismantling of RCC post or struts carefully of any section embedded in concrete incl taking out embedded portion and making good disturbed ground incl taking down/out worn out unserviceable old barbed wire, chain link fencing complete.
Excavation in post hole each n.exc 0.50 Cum getting out returning filling in and ramming earth around in layers n.exc 25cm watering and removed surplus soil to a distance n.exc 50m in soft/loose soil.
S&F Mild steel for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0
M&L for PCC M-10 grade (nominal mix) using 40mm graded stone aggregate cement concrete in foundations, filling and mass-concrete for fencing post etc.
Supply only galvanized steel chain link fence fabric of mesh any size, made out of 2.50 mm nominal dia of mesh wire complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
S&F in repairs galvanised 2 strand barbed wire 2.24mm dia of wire and 2mm dia of barbed at 75mm spacing and straining and fixing to any type of stranded nails straining bolts, including securing or tying at crossing with and provn of galvanised MS wire staples or steel pins etc as specified.
All as per item No. 63 here in before but restraining resecuring old fence including making good staples etc only all old wire fit for reuse as directed.
M&L for preparation of untreated new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint ( 1st grade quality ) over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint ( 1st grade quality ) complete all as specified and as directed.
Taking down / removing existing water proofing treatment from RCC roof slab including removal of plaster bed below felt / membrane and disposal of the same off the premises where directed and M & L for 10 mm thick screeding / rendering in cement mortar 1:4 on concrete roof surface, using liquid Water Proofing Compound as per manufacturers instruction, surface finished even and smooth without using extra cement all as directed. Note: Liquid water Proofing Compound shall be measured and paid separately under relevant item of this BOQ.
M & L for applying APP (Atactic Poly Propylene) bitumen membrane 3mm thick APP modified weight not less than 3.60 Kg/Sqm reinforced with non woven polyester fibre of weight 160 gms/sqm as centre core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene, applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer 0.40Kg/Sqm over roof ( An overlap of 100mm & 150mm shall be provided on sides and ends respectively ) and finally applying a coat of solar reflective bituminous aluminium paint @0.15 Kg/Sqm over the membrane. Complete all as per manufacturers instructions.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) removing rubbish off the premises all as specified and as directed by Engr-in-charge
M&L 75mm thick PCC M-7.5 grade (nominal mix) using 40 mm graded stone aggregate as in sub base or similar items all as specified and as directed.
M&L for Sand filling under floors including consolidation. The thickness of sand cushion should not be less than 25mm for laying paver blocks.
M&L for 80mm thick coloured rubberised, glossy finish colour machine pressed interlocking pattern paver block any shape and size conforming to IS 15658-2006 of M-40 Grade incl all as specified and as directed by Engineer-in Charge.
S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and as directed by Engineer-in Charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame complete all as specified and as directed by Engineer-in Charge.
M & L for Welding in repairs n. exc 5cm in length thickness of metal to be welded n exc 6mm all as specified and as directed by Engineer-in Charge.
Taking down copper/aluminium point wiring ( light, fan, socket, power ) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surface of walls, floors, etc
M&L concealed Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLSH cable as earth continuity wire including modular metal flush box with white/coloured top cover plate and frame of required modules for mounting of modular switches, sockets, bell push and fan regulators complete incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and as directed by Engineer-in-Charge. for the following:-
One Light point /Fan/Ex Fan/Bell point controlled by one switch
one 3/5 pin socket outlet 5/6 Amps on the same board
one 3/5 pin socket outlet 5/6 Amps on independent Board
All as per item No. 77.00 but one 3 pin socket outlet 15/16 Amps independent Board with cable of size 2.5sqmm nominal area.
All as per item No. 77.00 but one 3 pin socket outlet 15/16 Amps independent Board with cable of size 4sqmm nominal area.
Supply & fix modular switch 1 way, 5/6 Amps, 1 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular Bell push, 5/6 Amps, 1 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket, 5/6 Amps, 2/3 pin combined 2 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular switch 1 way, 16 Amps, 1 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket, 6/16 Amps, 2/3 pin combined 2 module (ISI marked).complete all as specified and as directed.
Supply & fix modular type fan regulator 100 Watt, 1/2 module complete all as specified and directed by Engr-in-Charge.
M & L for submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6sqmm (Nominal area) drawn through in and including PVC conduit/casing capping with all fittings and accessories as required at site along with one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of 6sqmm cable with one run of 6sqmm cable as earth wire and one run of casing capping/conduit shall be measured as one unit length.
M & L for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4sqmm (Nominal area) drawn through in and including PVC conduit/casing capping with all fittings and accessories as required at site along with one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of 4sqmm cable with one run of 4sqmm cable as earth wire and one run of casing capping/conduit shall be measured as one unit length.
M & L for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5sqmm (Nominal area) drawn through in and including PVC conduit/casing capping with all fittings and accessories as required at site along with one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of 6 sqmm cable with one run of 1.5sqmm cable as earth wire and one run of casing capping/conduit shall be measured as one unit length.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F recess mounted LED panel, 36 watt ( 2'x2'), highly efficient suitable for celling complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable all as specified and directed by Engr-in-Charge.
S & F Lamp holder of PVC/ Polycarbonate type with back plate complete all as specified and directed by Engr-in-Charge.
S&F LED lamp 9 watt, CDL, B22/E27, 230V, PF-0.95 (min), complete all as specified and directed by Engr-in-Charge.
S&F call bell electric, ding dong, AC 240 volt, 50 HZ. all as specified and as directed.
S&F ceiling rose surface Bakelite three terminal all as specified and directed by Engr-in-Charge.
S&F Sheet metal enclosure SPN 08 way (MCB DB) Double door, 240 Volts AC.
S&F Sheet metal enclosure SPN 04 way (MCB DB) Double door, 240 Volts AC .
S&F MCB, SPN (Double Pole) 32 amps, 240 Volts, 10 KA ‘’C” curve all as specified and directed by Engr-in-Charge.
S&F MCB, Single Pole, 5 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’B” curve all as specified and directed by Engr-in-Charge.
S&F Vertical MCB distribution board, as MCB TPN incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismantling taking down unserviceable one all as specified and directed by Engr-in-Charge.
S&F MCCB 63 Amps, 4 Pole, 16 KA complete all as specified and directed by Engr-in-Charge.
S&F Metal plug and socket board with MCB SP 16/20 amp, 16 KA incl dismantling taking down unsv one all as specified and directed by Engr-in-Charge.
Taking down ceiling fan, dismantling blades and removing blades and painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and refixing the same with all new fitting like down rode, (suitable length reqd at site), washer, nut & bolt etc. complete all as specified and directed by Engr-in-Charge
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge. Note - Old unserviceable ceiling fan deposit to MES store
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers incl making of suitable hole in brick / stone wall for fixing of Exhaust Fan and making good the disturbed surface to match with existing complete all as directed by Engineer-in-charge. Note - Old unserviceable Exhaust fan shall be deposit in MES store
S&F Exhaust fan 250 mm sweep made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300m incl making of suitable hole in brick / stone wall for fixing of Exhaust Fan complete all as directed by Engineer-in-charge.
S&F LED building security light 35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener all as specified and directed.
S&F LED Flood light 70 Watt, 230 V with lens complete with all accessories and including connecting up to ceiling rose with 1.5 sqmm three core copper flexible conductor cable, all as specified and directed.
M & L for Earthling complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion complete all as directed by Engineer-in-charge.
M & L for 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 4sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire from OH conductor to building incl dismantling taking down unserviceable one all as specified and directed.
M/S J J ENTERPRISES
M/S KISHAN CONSTRUCTION
VP DEVELOPERS AND CONTRACTOR
M/S JAYCONSTRUCTION CO
AJINKYA VIKRAM GAIKWAD
S.R.M.K Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .