COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
REPAIRS TO TRANSFORMERS, VCBS, HT CABLE, HT POLES, GOD AND ALLIED WORKS AT ZONE III AND IV AND AVN BASE AND MAIN OF 33 KVA MRS UNDER GE DINJAN
2021_MES_490462_2
84028E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE DINJAN
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE DINJAN
₹50,800
Yes
24 Feb 2022
15 Jan 2022
5 Feb 2022
15 Jan 2022
3 Feb 2022
22 Jan 2022
15 Jan 2022 - 20 Jan 2022
Amount
Supply only vacuum interrupter for VCB 11 kV of capacity upto 650 Amps of any Make
Supply only PT Public 11KV/110 VAC for vertical VCB for incorporating in 11 KV Indoor VCB Vertical Isolation
Supply only Vacuum circuit with Assy Epoxy Chamber for incorporating in 11 KV Indoor VCB Vertical Isolation
Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside by diconnecting all electrical connections for re-use or removing to store or for schedule of credit all as directed by Engr-in-Charge
M & L for spray painting of transformers (any type power or distribution)) of capacity above 300 kVA and upto and including 500 kVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the GE including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Spray painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed.
Supply only new transformer oil of dielectric strength not be less than 60 kV and conforming to IS-335 of 1993 for filling/ topping up oil of transformer up to desired level complete all as directed.
Dehydration and filtration of existing transformer oil of transformer at different location with filtration machine and heating system to get the minimum di-electric strength of oil 40 kV minimum without disturbing the power supply system and refilling/ topping up /replacement of unserviceable transformer oil complete all as specified and as directed.( Note: Transformer oil required extra for filling/topping up shall be measured and paid separately under the relevant items of this schedule).
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for broken stone/ boulders aggregate for loose filling, of gauge 80 mm to 150 mm graded complete all as specified and as directed.
S & F drop out fuse unit expulsion type for outdoor air brake gang operated switches single pole mounted and including insulator for 22 kV working pressure fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line taps and suitable for current carryout capacity 25 Amps.
S & F XLPE cable end termination, heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 11 kV (Earthed), 3 core 50 sqmm complete all as specified and as directed.
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core 95 sqmm complete all as specified and as directed.
S & F cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
S & F in repairs 32 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F in repairs 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. or carrying to MES store (spare/components for replacement to be provided free by department)
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 11 kV, rated voltage 12 kV, rated normal current 200 Amps, rated frequency 50 Hz, with 15 no of insulators, rated one minute power frequency withstand voltage between (i) earth & poles 28 kV (rms) (ii) across the isolating distance 32 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 75 kV (Peak) (ii) across the isolating distance 85 kV (Peak), Rated short-time withstand current 25 kA for 3 seconds, rated peak withstand current 63 kA for climatic conditions at the site, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
Supply and erection of lightning arrestor explusion type suitable for 11 kV continuous operating voltage (3 phase) with rated voltage 24 kV (rms) with nominal discharge capacity of 65 kA and complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and as directed. Note- Lightning attester shall be able to withstand wind load of 196Kg/Sqm and seismic acceleration of 0.39g.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 11 kV, nominal cross sectional area of main conductor 95 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit (credit for above items should be made as per conditions separately) all as specified and directed by the Engineer-in-Charge.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 11 kV, three phase, earthed system, 3 core, screened, armoured power cable, 95 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing including taking down complete all as specified and as directed.
Supplying & laying in trenches 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 6.35 kV/ 11 kV, three phase, earthed system, 3 core, screened, armoured power cable, 95 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
Supply & laying unreinforced precast concrete cable cover class HV type 1, flat shape, dimension 300 mm X 180 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed.
Laying only unreinforced precast concrete cable cover class HV type 1, flat shape, dimension 300 mm X 180 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed.
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green, two-in-series assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and as directed.
S & F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
Fixing and stringing only ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
Dismantling ACSR or AAC conductors from HT oh lines/structures and removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling HT insulators any type, any size by diconnecting all electrical connections complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
Dismantling steel poles/ struts, any size, setting aside for reuse within 50 metres
M & L for steel tubular swaged pole 410 SP-55 (11.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
M & L for preparing and painting and painting on steel tubular swaged pole 410 SP-55 (11.00 metre long) including cross arms, GI brackets with two coats of aluminium paint over a coat of aluminium red oxide primer on exposed portion and including making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Clearing tree branches upto 3 metre distance from conductor complete all as specified and as directed.
Clearing of vegetation/ creepers/ grass etc. from pole complete all as specified and as directed.
M & L for cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 mm or 4 mm dia complete all as specified and as directed.
M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 250 mm X 200 mm complete all as specified and as directed.
Repair/maintenance/Servicing of 33 KV MRS for commissioning Disconnecting existing incoming & outgoing connections and repair , overhauling and maintenance of , 33 KV Auto Recloser and making serviceable for charging 33 KV MRS including all spares as required all as directed. Note : Spares required deemed to be included in quoted rate.
M & L for repairing & servicing of 33 KV Gang Operated Air Break Isolator & Earth Switch including carrying out following activities complete all as specified and as directed: [a] Cleaning of contact for dust, oxidation & pitting with CTC. [b] Cleaning of all insulators with CTC and observing any cracks and carbon deposits / contents. [c] Repairing, adjusting the rotating arms for perfect operation including lubrication with Petroleum Jelly [d] Repairing / Replacement of Tension Spring in Fixed Contacts. [e] Lubricating of all moving parts for smooth operation. [f] Checking of Auxiliary Contacts and their Calibration [g] Applying Petroleum Jelly to all Electrical Contacts / Moving Contacts. [h] Tightening of all Electrical and Mechanical Connections. Note: The rate quoted is deemed to be inclusive of Consumables like nuts & bolts, washers, petroleum jelly, CTC, T & P etc. complete and necessary safety measures for working in 33 KV Yard.
M & L for inspecting, checking, servicing of 33 KV Lightening Arrestors by decarbonising of lighting arrestors, tightening all earthing connections and HV connections for proper contact, application of petroleum jelly to the electrical connections, replacement of corroded nuts and bolts etc. complete all as specified and as directed. Note : Spares required deemed to be included in quoted rate.
M & L for Repairing / Servicing of 33 KV / 110 V PT [Outdoor type] including carrying out following activities complete all as specified and as directed: [a] Checking PT Limb[Ceramic insulator] for any cracks, pitting and burns [b] Cleaning / Decarbonising with CTC [c] Replacing insulator oil with New Oil. [d] Carrying / conducting Ratio Test. [e] Tightening all Primary and Secondary connections. [f] Tightening and fixing basement Nuts & Bolts Note : Spares required deemed to be included in quoted rate.
M & L for Servicing of 33 / 11 KV CT [Outdoor Type] by Checking CT Limb for any cracks, pitting and burns, Cleaning / Decarbonising the Limbs with CTC, Complete drain out of old insulating oil and filling new Insulator Oil, conducting Ratio Test and Tightening all Primary and Secondary connections complete all as specified and as directed. Note : Spares required deemed to be included in quoted rate.
Material and labour for servicing of 33 KV/433 Volt Station Transformer for ensuring servicibility including checking HT/LT Bushes,insulators and mounting arrangement all as directed.Note:Spares required shall be deemed to be included in the unit rate. Note : Spares required deemed to be included in quoted rate.
Disconnecting all incomming /out going connections of 33/11 KV, 2.5 MVA Transformers and carry out all servicing/maintenance duly visually inspection of all parts for ensuring servicibilities of parts such as Bushing,gasket,silica gel,temperature gauge and relays including reapir as required at site including carrying out following Onsite Tests for 33 / 11 KV Transformer with required / suitable testing equipment by Qualified and Licensed Personal, Recording Test Results and submitted to GE to keep on record duly signed by all concerned complete all as specified and as directed: [a] IR Test [b] PI [c] Magnetic Balance Test [d] Ratio test [e] Di-electric Test of Oil [f] Short Circuit Test [g] Vector Group [h] Winding Resistance. Note:Materils required at site are deemed to be included in the unit rate.
Supply and Fix Earth Mat as per existing specification all as directed.
Materil and Labour for inspection of Earth Pits and checking the earthing values including necessary addition/alteration for ensuring correct earth values as desired. Note:Materials such as salt/charcoal including excavation if required shall be deemed to be included in the quoted rate.
Calibration & testing of all the electromagneitic/ thermal/ digital microprocessor based relays of 33KV and setting the relay tripping timings in advance to the feeding sub station to ensure re-installation of various relays in position with complete testing, commissioning and ensure proper functioning with following testing:- (i)CT Calibration through Primary injection test. (ii) Secondary injection for relay calibration. Notes :- (a). Primary & secondary injection kit shall be arranged by the contractor (b) DC Supply for relay testing shall arranged by the contractor (c) The contractor shall prepare the relay adjustment and tripping timing chart in the follow up fashion and submit to Engineer-in-Charge33 KV, Control & Relay Panel (d) Spares required deemed to be included in quoted rate.
Calibration & testing of all the electromagneitic/ thermal/ digital microprocessor based relays of 11KV and setting the relay tripping timings in advance to the feeding sub station to ensure re-installation of various relays in position with complete testing, commissioning and ensure proper functioning with following testing:- (i)CT Calibration through Primary injection test. (ii) Secondary injection for relay calibration. Notes :- (a). Primary & secondary injection kit shall be arranged by the contractor (b) DC Supply for relay testing shall arranged by the contractor (c) The contractor shall prepare the relay adjustment and tripping timing chart in the follow up fashion and submit to Engineer-in-Charge33 KV, Control & Relay Panel (d) Spares required deemed to be included in quoted rate.
M & L for Filtration of Transformer Oil of transformers installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with Portable Filtration Plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as specified and as directed. Note : Spares required deemed to be included in quoted rate.
Supply, filling and topping up new transformer oil of dielectric strength not be less than 60 kV and conforming to IS 335: 1993 complete all as specified and as directed.
Materil and Labour for inspection of Battery Bank & Battery Charger and checking the serviceability of batteries including necessary addition/alteration for ensuring serviceability as desired. Note:Materials if required shall be deemed to be included in the quoted rate.
M & L for inspecting, checking, servicing of 33 KV Disc / Post Top Insulator including carrying out following activities complete all as specified and as directed: [a] Checking insulator for any cracks & pitting [b] Checking Interlocking Pins for corrosion and replacing if necessary, cleaning / decarbonising with CTC. [c] Replacing the corroded, rusted nuts & bolts of clamps of conductors if necessary. [d] Tightening of all supporting connections. Note : Spares required deemed to be included in quoted rate.
M & L for cleaning and servicing of complete HT 33 / 11 KV structure by greasing, cleaning, servicing of jumpers, re-jumpering wherever required, tightening of nuts & bolts etc at main receiving point to distribution bus bar bay structures up to transformers inside MRS complete all as specified and as directed.
ms singh construction
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .