Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹28.4 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | 2₹40.8 L+₹11.2 L (38.0%)Rejected-Finance 0 KALIKAPUR KALIKA PUR CHAMPAHATI SOUTH 24 PARGANAS WEST BENGAL 743330 | 24 PARAGANAS SOUTH | WEST BENGAL | 743330 | 2 | Rejected-Finance Other than lowest | |
| 3 | 3₹42.4 L+₹12.9 L (43.7%)Rejected-Finance 0 GANGARAM DHARMKANTA TRUCK UNION JIROTA KALAN DAUSA DAUSA RAJASTHAN 303303 | DAUSA | RAJASTHAN | 303303 | 3 | Rejected-Finance Other than lowest | |
| 4 | 4₹42.9 L+₹13.4 L (45.3%)Rejected-Finance 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | 4 | Rejected-Finance Other than lowest | |
| 5 | 5₹43.0 L+₹13.5 L (45.6%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | 5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹66,500
Closing Date
2 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700 022
REPAIR/ MAINT OF EXTERNAL ELECTRIC SUPPLY AT OTM/ MD ACCN AT FORTWILLIAM UNDER GE FW) KOLKATA
2020_MES_338791_3
GE(FW)/8647/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Fort William Kolkata
Ref tender document
6 documents required · 6 mandatory
₹500
Yes
GE (FW) Kolkata
₹66,500
Yes
15 Sept 2020
20 Aug 2020
4 Sept 2020
20 Aug 2020
2 Sept 2020
20 Aug 2020
60 days
Amount
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :-
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 50 Sqmm, 3.5 core
70 Sqmm to 120 Sqmm, 3.5 core
150 Sqmm to 185 Sqmm, 3.5 core
240 Sqmm to 400 Sqmm, 3.5 core
1000 sqmm, single core
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed.
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed.
Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) complete all as directed by the Engr-in-Charge of the following sizes :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 50 Sqmm, 3.5 core
70 Sqmm to 120 Sqmm, 3.5 core
150 Sqmm to 185 Sqmm, 3.5 core
240 Sqmm to 400 Sqmm, 3.5 core
1000 sqmm, single core
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole complete of the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 Sqmm, 4 core
16 Sqmm, 4 core
25 Sqmm, 3.5 core
70 Sqmm, 3.5 core
95 Sqmm, 3.5 core
120 Sqmm, 3.5 core
185 sqmm, 3.5 core
240 sqmm, 3.5 core
400 sqmm, 3.5 core
1000 sqmm, single core
M&L for sand cushioning/sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. (NOTE: Punned thickness shall be measured for payment)
M&L fly ash bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
S&F straight through Joints (epoxy) using Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
upto 50 sqmm 3.5/4 core
70 sqmm to 150 sqmm, 3.5 core
185 sqmm to 300 sqmm, 3.5 core
400 sqmm, 3.5 core
1000 sqmm, single core
Taking out old burnt thimble from cable terminals and cutting the cable and socketing and crimping new aluminium thimble and connecting with panel board complete all as specified and directed by Engr-in-Charge for the following size of cables :-
25 sqmm to 35 sqmm
50 sqmm to 95 sqmm
120 sqmm to 185 sqmm
240 sqmm to 400 sqmm
Taking out old burnt thimble from cable terminals and cutting the cable and socketing and crimping new copper thimble and connecting with panel board complete all as specified and directed by Engr-in-Charge for the following size of cables :-
16 sqmm to 25 sqmm
35 sqmm to 70 sqmm
95 sqmm to 120 sqmm
Supply and fix (in replacement) MCCB, 4 pole, 36 KA, with thermal maganetic release range, 630 Amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Type DN3-630D, Cat No: CM94106OOT1OG / LEGRAND, Cat No: 4220 09 / C&S, Cat No: CSC6N4630 / HAVELLS, Cat No: IHB3HEMF0630 / or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
Supply and fix (in replacement) MCCB, 4 pole, 36 KA, with thermal maganetic release range, 400 amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Type DN3-630D, Cat No - CM94106OOS1OG / LEGRAND, Cat No: 4220 07 / HAVELLS, Cat No: IHBA9EMF0400 / C&S, Cat No: CSE3M400ATM4P_400 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
Supply and fix (in replacement) MCCB, 4 pole, 25 KA with thermal maganetic release range, 250 Amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Type DN1-250C, Cat No - CM90642OOPO/ LEGRAND, Cat No: 4202 19 / C&S, Cat No: CSE2M250ATM4P-250 / HAVELLS, Cat No: IHD2HOBF0250 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
S & F in repairs MCCB 4 pole 25 KA with thermal magnetic release range 200 Amps, Ics= 100% of Icu, complete with all accessories including taking down existing old MCCB complete all as specified and directed. (Make : L&T, Cat No - CM90642OONO / LEGRAND, Cat No: 420218 / C&S, Cat No: CSE2M250ATM4P-200 / HAVELLS, Cat No: IHD2HOBF0200 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
Supply and fix (in replacement) MCCB, 4 pole, 25 KA with thermal maganetic release range, 160 Amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Type DN1-250C, Cat No - CM90642OOMO / LEGRAND, Cat No: 4200 57 /C&S, Cat No: CSE2M250ATM4P-160 / HAVELLS, Cat No: IHD2HOBF0160 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
S & F in repairs MCCB 4 pole 25 KA with thermal magnetic release range 125 Amps, Ics= 100% of Icu, complete with all accessories including taking down existing old MCCB complete all as specified and directed. (Make : L&T, Cat No - CM90642OOLO / LEGRAND, Cat No: 420056 / C&S, Cat No: CSE1M125ATM4P-125 / HAVELLS, Cat No: IHDA6OBF0125 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
Supply and fix (in replacement) MCCB 4 pole 25 KA with thermal maganetic release range 100 Amps Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Type DN1-250C, Cat No - CM90642OOLO / LEGRAND, Cat No: 4200 55 /C&S, Cat No: CSE1M125ATM4P-100 / HAVELLS, Cat No: IHDA6OBF0100 or equivalent model in ABB / SCHNEIDER / INDO ASIAN (OPTI POWER) / HAGER)
Supply and fix (in replacement) MCCB 4 pole 25 KA with thermal maganetic release range 63 Amps Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make : L&T, Type DN0-100C, Cat No - CM91712OOHOOG / LEGRAND, Cat No: 4200 53 / HAVELLS, Cat No: IHDA6OBF0063 / C&S, Cat No: CSE1M125ATM4P-63 or equivalent model in SCHNEIDER /ABB / INDO ASIAN (OPTI POWER) / HAGER)
M & L for Earthing with Galvanised Steel Earth Plate Electrode 600X600X6.0mm thick, buried directly in Ground (Earth Pit not less than 2.25 METRE deep below Ground Level) with Top Edge of the Plate not less than 1.50 METRE below Normal Ground Level connected to GI strip 32x6mm Earthing Lead up to 7.5 METRE from Testing Point by means of Bolts, Nuts, Check Nuts and Washers of Galvanised Iron or Steel, Earth Plate Electrode surrounded by a packed thickness of Char Coal mixed with Common Salt in alternate layers of not exc.150mm thick, Strip protected with and including GI Pipe 40mm Bore (dia) ‘Medium Grade’ for mechanical protection including PCC Pit in Cement Concrete (1:3:6) Type C1 (20mm Graded Stone Aggregate) and Pre-Cast RCC Cover of Size 450X450X50mm in RCC (1:2:4) Type B1 (20mm Graded Stone Aggregate) with Mild Steel Round Bar 10mm Handle of suitable Size, Reinforced with and including 8.0mm dia TMT Bars @ 100mm Centre to Centre both ways GI Wire Mesh, Funnel, GI Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/Loose Soil, Returning Filling in and Removal of Surplus Spoil up to a distance of 50 metre and complete all as shown in Figure 15A of IS 3043 :1987, and Testing on completion including taking down Unserviceable Earthing, complete all as specified and directed.
Supply and fixing in repair 80 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing in repair GI tubing 50mm bore (light grade) in trenches/floor/fixed along pole for cable/earth strip protection with proper size of clamp, nuts and bolts or for fixing lightning conductors etc all as specified and as directed by Engineer-in-Charge.
Material and labour for PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge.
Taking down old unserviceable Feeder Pillar box/ LT Panel and Supply, install, commissioning and testing in replacement cubical type outdoor type Bus bar junction box, made out of 3.15 mm thick mild steel sheet, of size not less than 700 mm x 650 mm x 500 mm, fabricated in CPRI approved factory with mild steel angle iron frame and legs (of length 300 mm) of section 40 mm x 40 mm x 6 mm thick, with front openable door (with locking arrangement) duly powder coat painted over a coat of red oxide primer dust and vermin proof with provision of cable entry and exit at mid portion of the feeder pillar box (with cable gland), and providing one number Danger Notice Plate (of size 15 cm x 10 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with clamps and nuts-bolts of suitable size) and providing necessary foundation of the feeder pillar box in PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) complete all as directed by the Engr-in-Charge comprising of the following accessories :-
Copper bus bar 630 Amps (size 40mm x 10mm x 400mm) capacity - 4 Nos
LED indicating Lamp with holder for main & standby supply indicating RYB (Set of three) - 01 Set
MCCB (Incoming) 125 Amps, 4 Pole, 25 KA, Ics= 100% of Icu - 01 No (Make : L&T, Cat No - CM90642OOLO / LEGRAND, Cat No: 420056 / C&S, Cat No: CSE1M125ATM4P-125 / HAVELLS, Cat No: IHDA6OBF0125 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
MCCB (Outgoing) 63 Amps, 4 Pole, 16 KA, Ics= 100% of Icu - 02 Nos (Make : L&T, Cat No - CM90518OOHO / LEGRAND, Cat No: 420013 / HAVELLS, Cat No: IHDA3BBF0063 or equivalent model in SCHNEIDER / ABB / HAGER / INDO ASIAN (OPTI POWER)/ C&S)
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
Taking out unserviceable LT panel board / FEEDER PILLER box (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1200 mm x 900 mm x 500 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar of section 50 mm x 6 mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 50X 50X 6 mm with legs not more then 60 cm including grouting with P C C complete including earthing all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
MCCB (incoming) with thermal-magnetic release of capacity 400 Amps, 4 pole, 50HZ, 36 KA, Ics= 100% of Icu - 01 No. (Make: L&T, Type DN3-630D, Cat No - CM94106OOS1OG / LEGRAND, Cat No: 4220 07 / HAVELLS, Cat No: IHBA9EMF0400 / C&S, Cat No: CSE3M400ATM4P_400 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
MCCB (Outgoing) with thermal-magnetic release of capacity 100 Amps, 4 pole, 50HZ, 36 KA, Ics= 100% of Icu - 4 Nos. (Make : L&T, Cat No - CM90642OOLO / LEGRAND, Cat No: 420095 / HAVELLS, Cat No: IHBA6FLF0100 / C&S, Cat No: CSCN125EM1004Por equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
GHOSH ENTERPRISE
Shanti Construction Company
JAGATMATA ENTERPRISE
dutta and dutta
JOY-EN-JOY
MS HORIZEN
SINHA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .