WORK OF Issue of 90 KW new connection to Govt. ITI Marhara on Semi Turnkey basis in the area of EDD IInd Etah under deposit scheme.
2024_DVVNL_927707_3
01/2024-25/EDC ETAH
Open Tender
Electrical Works
Item Rate
Distt Etah
As per Tender Documents
2 documents required · 2 mandatory
₹1,180
DVVNL
₹5,000
7 Nov 2024
18 Aug 2024
23 Aug 2024
18 Aug 2024
23 Aug 2024
18 Aug 2024
Amount
Supply of 11 KV Line Material as per relevant ISS
F-Clamp
Barbed wire
N&B off size
Stone Pad 300x300x75
Clamp with N&B
Danger Board
PG Clamp
Number Plate
O/D Jointing Kit suitable for 3x70 sq mm XLPE Cable
I/D Jointing Kit suitable for 3x70 sq mm XLPE Cable
Aluminium Binding Wire
Dropper Chanel
Top Channel 125x65x2240 mm with Clamp
MS Angle 65x65x6x3800 mm
Earthing Complete
Guarding Angle
T off Channel with Clamp
11 KV Cross Arm Clamp
GI Pipe 6" Dia
Erection Work
Safe carriage of line material from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side.
Safe carriage of 8.5 Mtr Long PCC pole from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side.
Safe carriage of 11 Mtr Long ST pole from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side.
Safe carriage of 11 KV VCB from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side.
Safe Carriage of 250 KVA TF from Electricty store center Etah/nearest 33/11 KV S/S to direect Pit site in distance range 0 to 30 Kms. Including loading and unloading at both side.
Erection of 8.5 mtr long PCC Pole as single support including fixing of HT/LT accessories etc complete, pole should be gruted properly as per DVVNL/Respo norms.
Erection of 11 mtr ST Pole as single support including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms.
Erection of 11 mtr ST Pole as Try Pole including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms.
Construction of 250 KVA T/F plinth for size 2x2x1.5 M with the help of first class brick and masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely as per norms with RCC top 1:2:4 cement, sand coarse and stone grit with MS Bar and MS channel for resting transformer wheel (100x50x6mm) and plaster. All material shall be provided by the contractor.
Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended metal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut
Installation of 250 KVA T/F on newly constructed Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work
Pipe earthing up to water level of 250 KVA medium Power Transformers
Laying, sagging stringing, binding, jumpering & fixing of all accessories etc of following conductor on the newly/old erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work.
ACSR Rabbit Conductor
ACSR Dog Conductor
11 KV XLPE Cable 3x70 sq mm
Stone Pad 300x300x75
Danger Board with Clamp
PG Clamp
Number Plate
Installation of 11 KV VCB O/G
O/D Jointing Kit suitable for 3x70 sq mm XLPE Cable
I/D Jointing Kit suitable for 3x70 sq mm XLPE Cable
Earthing Complete
Stay Set Complete
GI Pipe 6" Dia
Grouting of main metering cubicle inside the meter room alongwith termination of 11 KV cable.
New Guarding of HT Line with GI wire as per RESPO norms
ABG ENGINEERS
M/s APOORWA ELECTRICALS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .