| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹49.5 L+₹95,164.90 (1.96%)Rejected-Finance | L2 | Rejected-Finance BEING L2 REJECTED | |
| 3 | L3₹49.5 L+₹97,635.65 (2.01%)Rejected-Finance 1501 BHAGWATI EMINENCE SAVITRIBAI PHULE MARG BESIDES R R PATIL GARDEN SECTION 13 NERUL E NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400702 | L3 | Rejected-Finance BEING L3 REJECTED | |
| 4 | L4₹49.7 L+₹1.2 L (2.41%)Rejected-Finance | L4 | Rejected-Finance BEING L4 REJECTED | |
| 5 | Rejected-Technical 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | - | Rejected-Technical NOT ADMITTED |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
9 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
CERTAIN REPAIRS TO RAILING, STEPS AND BOLLARDS, STRUCTURAL REPAIRS TO CONCRETE MEMBERS AT AMN JETTY AT NAVAL STATION KARANJA
2023_MES_608879_1
8680/E8
Open Tender
Civil Works
Item Rate
270 days
GE NW KARANJA
Class D and above and Category a i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹98,000
Yes
5 Sept 2023
13 Jul 2023
11 Aug 2023
13 Jul 2023
9 Aug 2023
27 Jul 2023
Amount
Notes : (i) The work consists of 01 job as under:- TPP NO 49 FOR YR 2023-24 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department.
Note:- The Unit Rate quoted is deemed to be include scaffolding, mobilization equipment and other safety equipments as the works will be caried underneath bridge of jetty. Nothing will be paid extra on account of working in difficult area.
Removing, chipping and cleaning of existing loose and damaged concrete carefully upto 60mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete including cleaning the surface by air jet and stacking & disposal of unserviceable materials outside the premises to a distance not exceeding 100 mtrs with & including all necessary scafolding safety net, props etc. complete all as specified and as directed
Providing and applying Bi-polar migratory corrosion inhibitor on concrete surface by spraying at 4 sqm/ltr and wiping the surface with moist cloth after few minutes to remove any residual material which has not penetrated, including all necessary surface preparation, necessary scaffolding, props, etc. as per requirement, complete all as specified and as directed
Cleaning all existing reinforcement bars with wire brush/rotary wire brush to make entire surface of bars free from rust scales, loose material, dirt etc. and M&L for applying alkaline rust converting primer on the existing rebars and allowing it to react with rust and form a corrosion resistant, insoluble protective layer, as per manufacturer's instructions with & including necessary scaffolding, props etc. complete all as specified and as directed. (Mode of measurement: per sqm of breaking area of concrete.)
M&L Drilling Holes of 12mm dia upto 100mm deep in structureal members at the interval of 300mm in stagered manner or along the crack line in RCC structural member including cleaning of the holes by air blower and inserting 12mm dia NRV nozzles compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix the nozzles inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 hrs before grouting: Cut and remove nozzle projections, excess putty, if any, over concrete element by grinding, levelling and finishing the external surface, after completion of the work, etc. complete all as specified and directed. The rate shall incude scaffolding and other necessary works.
Providing and injecting two part, low viscous, high strength epoxy resin based moisture insensitive liquid using pressure injector with accessories till nozzle refuses to accept the grout including mixing of grout material components in adequate proportions as per manufacturer's instructions by weight batching and grouting the mixed material into the structural member by grouting gun, maintaining desired pressure in the gun by air compressor and maintaining pressure at exit about 2 to 3 kg/cm2 by monitoring pressure guage at exit. The mixed grout should have following properties and sealing the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle complete all as specified and directed:- (i) Mixed Density 1.1 kg/I (at + 27°C); Viscosity ~ 250 mPas at + 30 °C and should comply according to ASTM C 881, Type II and IV, Grade-1, class E+F (i° Compressive strength >+ 70 N/ sqmm (7 days) according to ASTM C 579 (ii) Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638) (iii) Tensile Modulus ~2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638) (iv) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30oC cure (v) Flexural strength ~ 50 N/sqmm according to ISO 178.
M&L for TMT bars 10 mm and above, cut to length , bent to shape required, including cranking bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and as directed
M&L for TMT bars 6 mm to 8mm dia cut to length , bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and as directed
Providing and applying Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars,the product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per Sqm of application area of concrete, the rate shall include cost of scaffolding necessary for the work for any height complete all as specified & directed.
Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or microconcrete as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. including necessary scaffolding work for any height, all complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C.
Rebuilding the section of damaged RCC elements to its original size in thickness upto 60mm by providing and casting with ready to use non shrink, cementitious free flow micro-concrete having having compressive strength >60 N/sqmm (28 days) according to ASTM C 1107-99 including. drilling holes and fixing shear connectors, mixing the microconcrete with adequate quantity of water, placing, levelling the surface by grinding off cementitious slurry or cementitious joints diffencess if any and curing complete all as specified and directed. (The rate to include cost of scaffolding as per site requirement at any height)
M&L Formwork to sides of rough finish surfaces of concrete pillars, posts, struts, piers, columns, and stanchions fair finished surfaces of concrete etc all as specified and directed.
Design, fabrication supply and laying of FRP system for strengthening of structural elements comprising of FRP sheet and compatible saturant, by dry/wet layup system including surface preparation: Grinding, moulding concrete substrate. Cleaning it with wire brush, removing oil, laitance if present. Rounding off sharp edges to minimum 25mm radius. Proofing:Applying epoxy primer on prepared substrate, filling holes and uneven surfaces with thixotropic putty, etc. complete. Wrapping: Wrapping the fibre sheet to structural element at desired orientation with application of compatible epoxy saturant using tamping roller to avoid any air voids. Sand pasting: Applying second coat of saturant, rectify air voids if any; paste the river sand on it to make surface rough to take further finishes complete all as specified and directed. Note : (Mode of measurement: Fiber area or application, not surface area of RCC member. Rate to include scaffolding as per site requirement at any height). CFRP 230 GSM
Taking down cement or cement lime plaster, any description on brick or stone, concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed
Rebuilding the section of structural damaged RCC/PC elements to its original size and shape upto 20 mm thickness by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >=50 N sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/sqmm (7days) according to ASTM C 293-79 complete all as specified and as directed. (The rate shall include cost of scaffolding required for the work at any height).
M&L 20 mm thick polymer modified ready mix cement based plaster on external surfaces finished even and smooth complete all as specified and directed.
M & L 15 mm thick ready mixed cement base plaster on internal surfaces on brick or concrete surfaces finished even and smooth complete all as specified and directed.
M&L 5 mm thick (average) polymer modified ready mix cement based plaster on ceiling surfaces finished even and smooth complete all as specified and directed.
M&L for new or old surfaces of exterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clan water & allow to dry, fill visible cracks/ joints by chemistic crack seal caulking compound & allow to dry for 24 hours, apply a primer coat of chemistic prime M Seal (water base primer) and allow to dry for 6 hours, thereafter apply 02 coats of chemistik PDS-50 (WB high build anti caronatin coating cum waterproofing) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc complete all as per specified and directed.
M&L Preparation of newly plastered surfaces and applying two coats of oil emulsion distemper on walls over a coat of chalk whiting primer complete all as specified and as directed
Preparation of new plastered surfaces and M&L for applying three coats of white wash on ceilings complete all as specified and as directed Note : (For BOQ Serial item No 21 to 21.09). 1.Supplying & erecting scaffolding upto required height (max 25 to 30m) with necessary H frames, pipes, couplers, buckles, bracing, top platform with support railing at top necessary H-frames, pipes, couplers, buckles, bracing, top platform with support ralling at top etc. at an levels of building including carriage of the materials to the location, erecting, fixing the scaffolding and dismembering the same after working and taking away the scaffolding materials etc 2.Providing and erecting temporary bamboo scaffolding around the building as required. The scaffolding is to be secured properly in position by bracings, ties clamps, etc. complete including providing and erecting working platform at all heights as required, including removal after completion of work complete all as specified and as directed. 3.Providing and fixing dust proof netting with all required accessories/ fixing arrangement so as to cover existing installations and arrest the materials generated during repair work in adjoining areas and to prevent damage or nuisance to the existing structure; including proper provision of netting system at shown area before start of work, removal after completion of work, carrying out regular cleaning etc. 4.Supporting the structural components temporarily during repair and streghthening works using heavy duty flat-headed steel pipes vertically in plumb, braced horizontally and diagonallay at centre with each other using 40 B heavy steel tubes, and resting on wooden blocks to support the structure provisionally during repairs and maintaining them in position for required duration, complete all as specified and as directed by Engineer-in-charge. (Note: Mode of measurement - per prop per repetition). 5. Structural retrofitting work shall be got executed through one of the specialist firm(s) listed below: - (a) Rebuild Technologies Services Pt Ltd 602, 6th Floor, Tulsee Chamber, Teen Petrol Pump, Thane (W) E (b) Techton Buildcons Pt Ltd 203, Plot No 6, Milenium Plaza, Sakinaka Telephone Exchange Lane, Off AK Road Andheri E-Mumbai 72 (c) Sanrachana Structural Strenthening Pt Ltd 103, 104, Monalisa CHS, Hariniwas Circle, Thane West - 400602 (d) USHTA Infinity Construction Co Pt Ltd Ushta House, C-17/79 Krishna Industrial Estate, Gorwa, Vadodara - 390016 India (e) Gubbi Civil Engineers 18/26 Dev Prayag CHS, Op Thanawala garage, Bhakti Mandir Road, Near Hari Nivas Circle Thane (W), Thane, Maharashtra 400602
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC (1:2:4) type B-1 (Using 40 mm graded stone aggregate) as in surface channel complete all as specified and as directed
Extra for forming fair finished channel 30 cm inner girth in cement concrete, using extra cement including moulds forms, mitred-stops ends etc. complete all as specified and as directed
M&L for PCC (1:4:8 ) type D2 (Using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed
M&L for Plain cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in plinth courses, parapets, and railings, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for 100 mm thick Plain cement concrete (1:2:4) type B-1, (Using 20mm graded stone aggregate) as in paths/flooring complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D2 as in sub-base of floors complete all as specified and as directed
M&L for cement concrete work in pavement/hard standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre thickness of concrete 25 cm or more complete all as specified and as directed.
Finishing the cement concrete of roads pavements, by brooming complete all as specified and as directed
M&L for forming construction (Dummy) joints, 50 mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed
S&F in repairs pre cast cement concrete manhole/drain cover of size 600mm×600mm ×50mm thick arounded with steel strip 50x1.25mm reinforced as per manufacturer's design in manufacturer's process laid over existing drain complete all as specified and as directed
Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed.
M&L 25 mm thick Granite( of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking plat forms and like in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete with & including 10mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:4) as in backing coat of tiles complete all as specified and as directed
S&F Stainless steel 304 grade framed work fancy/ornamental type in hand rails in stair, baluster and posts, stair nosing gate work and other similar works including all or any type of welding followed by buffering and polishing for smooth finish including dismantling of existing complete all as specified and as directed
Demolition of brick work or stone boulded masonry built in cement mortar or cement lime mortar complete all as specified and as directed.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6m mean radius built in CM (1:6) etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished even and smooth without using extra cement complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed
M&L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) setin cement mortar (1:6) work for landings, cover slabs, manholes, chaijas, water troughs, manger shleves and similar articles with plain faces complete all as specified and as directed
M&L for Reinforced cement concrete (1:2:4) type B1 (using 20mm graded aggregate) as in footings, bases of columns, plinth beams etc.complete all as specified and as directed
M&L form work to sides of concrete foundations, footings, bases of columns, plinth beams and similar work; vertical or batter complete all as specfied and as directed.
Dismantling plain or corrugated steel sheeting ,any gauge ,thickness incl Nainital or similar pattern roof covering complete all as specified and as directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed
S&F pre-painted galvalume aluminium zinc coating Gl based Plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed
Dismantling of wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed
S&F for Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, welding etc. Fe-410W(GdeE-250) quality complete complete all specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-410-W (Ge- E- 250 quality)-A complete.all as specified and as directed
S&F mild steel Hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, running bars for nosing steps, including embeding in concrete and screwing etc. wind ties for roofs, posts,and struts in fencing, flat iron fillets etc and similar work conforming to Fe-290 de E-165 complete all as specified and as directed
S&F Famed work such as grills, gratings, etc. with ends of bars shouldered and for riveted, or forged in to spikes; framed guard bars; barred iron doors, ladders; framed balusters; walk ways; railings; and conformimg to Fe-290. Gde-E-165 complete all as specified and as directed
S&F Frame work as in doors, or gates of angle or other section with gusset plates, rails, braces etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings complete all as specified and as directed.
S8F mild steel work as in bollards and foundation complete fixing with bolting/welding and make the good the disturbed surface around the bollards complete all as specified and as directed
S&F MS plates (plain or chequered) channels, square cut or nocthed (ordinary and counter sunk forming holes, without any attachemnet complete all as specified and as directed
S&F Hard drawn steel wire fabric wt n. exc 4 kg per square cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement complete all as specified and as directed
Preparation new steel surface exc 10 cm width/girth and M&L for applying one two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Preparation of Old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and M&L for applying one coats of synthetic enamel paint complete all as specified and as directed.
Dismatling timber scantlings 40 sqcm and over in section, in any position complete all as specified and as directed
M&L 2nd class hard-wood scantlings complete all as specified and as directed.
Preparation new wooden surfaces of any description, not other wise described over 10 cm width or girth and M&L for applying two coats of synthetic enamel paint over one coat of pink primer complete all as specfied and as directed.
Preparation of old wall surfaces of any description & M&L for applying one coat of acrylic (antifungal) exterior grade paint on wall/roof complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
Preparation of new or previously untreated surfaces of any description & M&L for applying two coats of acrylic (antifungal) exterior grade paint over one coat of primer on wall/roof complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
Preparation of old plastered surfaces of walls& M&L for applying one coat of white wash complete all as specified and as directed.
M&L for running welding in repairs having thickness of metal to be welded exc 6mm but n.exc 9mm complete all as specified and as directed
INDIA ENGINEERS AND CONTRACTORS
SREE HARITHA ASSOCIATES
K N CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .