| 1 | L-1₹33.2 LAccepted-AOC | ₹33.2 L | L-1 | Accepted-AOC Lowest Bidder |
| 2 | L-2₹36.8 L+₹3.6 L (10.8%)Rejected-Finance | ₹36.8 L+₹3.6 L (10.8%) | L-2 | Rejected-Finance Other than lowest bidder |
| 3 | L-3₹41.4 L+₹8.2 L (24.6%)Rejected-Finance | ₹41.4 L+₹8.2 L (24.6%) | L-3 | Rejected-Finance Other than lowest bidder |
| 4 | L-4₹44.1 L+₹10.9 L (32.9%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹44.1 L+₹10.9 L (32.9%) | L-4 | Rejected-Finance Other than lowest bidder |
| 5 | Rejected-Technical R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | - | - | Rejected-Technical Complete Documents as per NIT not submitted |
Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
28 Jan 2023, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
AUGMENTATION AND IMPROVEMENT OF LT UG CABLE NETWORK, PERIMETER LIGHTS, JUNCTION BOXES AND ALLIED EXTERNAL SERVICE AT DAMANA UNDER GE JAMMU
2022_MES_572331_1
GEJC-66/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AOR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹99,800
Yes
15 Feb 2023
2 Jan 2023
30 Jan 2023
2 Jan 2023
28 Jan 2023
16 Jan 2023
Amount
Dismantling and removing and setting aside PCC pole / struts any type by breaking PCC foundation after disconnecting electrical connection including site clearance complete all as specified and directed by Engineer-in-Charge.
Material and labour for steel swagged poles complete poles 9 metre long complete with cast iron base plate, finial taperplug, bolts, nuts and screws as specified type 410 SP-31 with one coat of red oxide primer and two coats of aluminium paint and including marking alternate 5 no's black and white strip 30 cm height with two coats of synthetic enamel paint over a coat of primer including preparation of new surfaces all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft / loose soil or hard / dense soil for taking up or laying of cable all as specified and directed.
Description all as per Ser Item No 3.00 here-in-before but depth exceeding 1.5 m and not exceeding 3.0 m complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and as directed.
Supply and laying dry river sand laid in trenches as cable cushioning and covering all as directed. Sand cushioning to underground electric cable 8 cm before laying and 15 cm after laying the cable in trenches all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) mechanically crushed stone for mass filling in pole, pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, stay pits etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and directed.
Material and labour for PCC (1:2:4) type C-2 (using 20 mm graded crushed stone aggregate) as in pole foundation, coping etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and directed.
Disconnecting and taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 10 Sqmm, 4 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 16 Sqmm, 4 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 25 Sqmm, 4 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 35 Sqmm, 3.5 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 50 Sqmm, 3.5 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 70 Sqmm, 3.5 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 95 Sqmm, 3.5 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 120 Sqmm, 3.5 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 150 Sqmm, 3.5 core complete all as specified and as directed.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 185 Sqmm, 3.5 core complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched cable having three phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS : 7098 Part-II of size 3 x 50 Sqmm + 1 x 35 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched cable having three phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS : 7098 Part-II of size 3 x 70 Sqmm + 1 x 50 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched cable having three phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS : 7098 Part-II of size 3 x 95 Sqmm + 1 x 70 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched cable having three phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS : 7098 Part-II of size 3 x 35 Sqmm + 1 x 16 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 / 4.0 x 25-50 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 50-95 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 120-185 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for fixing in replacement of GI tubing 50 mm bore light grade, on poles, on walls, under floors, road crossing, as required at site complete all as specified and as directed by Engineer-in-Charge. Note: - Clamps, Nut bolts, saddle etc will be measured and paid separately.
Supply and fixing in repair OFF load change over switch with sheet steel enclosure 415 V, 4 pole, 63 Amps capacity fixed on walls for electric supply distribution between main and DG set including necessary connection of cables from LT panels to change over switches complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair OFF load change over switch with sheet steel enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set including necessary connection of cables from LT panels to change over switches complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of MCCB TPN 160 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as per directions of Engineer-in-Charge.
Supply and fixing in replacement of MCCB TPN 100 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as per directions of Engineer-in-Charge.
Supply and fixing and fabrication street light bracket made out of GI tubing suitable for 45 / 60 / 90 watt LED light grade upto 1.2 metre length, bend to shape suitable for security light fitting with necessary mild steel clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 30 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy > 120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor>0.95, working temperature range -20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 45 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor>0.95, working temperature range -20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 60 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, TOP opening separate driver compartment with frame, suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy>120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor>0.95, working temperature range -20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 90 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, TOP opening separate driver compartment with frame, suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy>120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor>0.95, working temperature range -20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 120 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, TOP opening separate driver compartment with frame suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy>120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor>0.95, working temperature range -20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED flood light fittings of 120 watt, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor>0.95, working temperature range -20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED flood light fittings of 200 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy>120 lm/W and system efficacy 90 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor>0.95, working temperature range -20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement SMC pole mounted box of size 10" x 8" x 4" with hinged door including clamp, nuts, bolts and washers complete all as specified and directed and including taking down of old unserviceable junction boxes. The Box includes: - (a) MCB SP 10 Amp, 10 KA 'C' Series mounted on din rail - 1 No. (b) Connector block suitable for 3 phase, 4 wire minimum 16 Sqmm cable - 1 No.
Material and labour for replacement of old unserviceable switch fuse unit / MCB of any type / capacity with new MCB four pole 40 Amps, 415 AC, 50 Hz, 25 KA with sheet metal enclosure complete all as specified and as directed.
Material and labour for replacement of old unserviceable switch fuse unit / MCCB of any type / capacity with new MCCB four pole 63 Amps, 415 AC, 50 Hz, 25 KA with sheet metal enclosure complete all as specified and as directed.
Material and labour in replacement for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and including dismantling and taking down old unserviceable complete all as specified and as directed.
Material and labour in replacement of PVC insulated and sheathed cable of size 2.5 Sqmm 3 core copper conductor multistranded 1100 Volt grade 230 Volts running through PVC conduit of dia 20 mm with strip clamping on poles at 3 places complete all as specified and as directed by Engineer-in-Charge.
vishesh engineers
DARVESH ENGINEERING WORKS
SATISH AND CO
Bidder Name
SATISH AND CO
Sarbat Construction Co
DARVESH ENGINEERING WORKS
vishesh engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .