| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC | L1 | Accepted-AOC Successful Bidder | |
| 2 | L2₹44.6 L+₹3.8 L (9.26%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹85,400
Closing Date
25 Nov 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
ADDN ALTN TO BILLET NO T167 T168 T169 E7 AND E8 AT ATS BELAGAVI
2022_MES_560224_1
8732/E8
Open Tender
Civil Works
Item Rate
90 days
GE AF Sambra
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE AF sambra
₹85,400
Yes
8 Dec 2022
28 Oct 2022
28 Nov 2022
28 Oct 2022
25 Nov 2022
12 Nov 2022
Amount
Material and labour sub main wiring two single core PVC insulated cables with copper conductor 1100Volts grade, 1.5 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed on walls, roofs or floors including one run of 1.5 sqmm PVC insulated cable as earth continuity conductor and connecting up complete all as specified & directed. Note:- 3 runs of 1.5 sqmm cable and one run of PVC conduit / casing & capping will be measured as one unit length.
Material and labour sub main wiring two single core PVC insulated cables with copper conductor 1100Volts grade, 2.5 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed on walls, roofs or floors including one run of 2.5 sqmm PVC insulated cable as earth continuity conductor and connecting up complete all as specified & directed. Note:- 3 runs of 2.5 sqmm cable and one run of PVC conduit / casing & capping will be measured as one unit length.
Material and labour sub main wiring two single core PVC insulated cables with copper conductor 1100Volts grade, 6 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed on walls, roofs or floors including one run of 6 sqmm PVC insulated cable as earth continuity conductor and connecting up complete all as specified & directed. Note:- 3 runs of 6 sqmm cable and one run of PVC conduit / casing & capping will be measured as one unit length.
Material and labour sub main wiring two single core PVC insulated cables with copper conductor 1100Volts grade, 10sq mm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed on walls, roofs or floors including one run of 10 sqmm PVC insulated cable as earth continuity conductor and connecting up complete all as specified & directed. Note:- 3 runs of 10 sqmm cable and one run of PVC conduit / casing & capping will be measured as one unit length.
Supply and fix switch socket outlet 2/3 pin 5 Amps, flush type alongwith Gang Box complete all as specified & directed.
Supply and fix switch socket combination, multipurpose 2 in 1, 3 pin 5 /15 Amps universal type controlled by one switch flush type alongwith Gang Box complete all as specified & directed.
S & F sheet metal enclosure, factory made, double door for Vertical TPN Distribution board 4 Way suitable for fixing Four Pole MCCB main incoming complete all as specified and as directed. Note : MCCB four pole will be measured and paid seperately under relevant item of thisschedule.
S & F sheet metal enclosure, factory made, double door for Distribution board 415 volts with 200 Amps rated bus bar, TPN 4 Way, IP 43 Protection complete all as specified and as directed.
S & F sheet metal enclosure, factory made, double door for Distribution board 240 volts with 200 Amps rated bus bar, SPN 2 Way, IP 43 Protection complete all as specified and as directed.
S & F MCCB four pole 100 Amps, 16 KA, 415 volts, 50 Hz AC supply, fixed thermal magnetic complete all as specified and directed.
S & F MCCB four pole 63 Amps, 16 KA, 415 volts, 50 Hz AC supply, fixed thermal magnetic complete all as specified and directed.
S & FL MCB TPN 40 Amps, C Curve, 415 volts, 50 Hz AC supply complete all as specified & directed.
S & F MCB TPN 32 Amps,C Curve, 415 volts, 50 Hz AC supply complete all as specified & directed.
S & F MCB SPN 6-32 Amps, C Curve, 240 volts, 50 Hz AC supply complete all as specified & directed.
S & F MCB SP 06 to 32 Amps, C Curve, 240 volts, 50 Hz AC supply complete all as specified & directed.
Supply, installation, Testing & Commissioning of 1 KVA Isolation transformer, Single phase, 50 Hz, Copper wound, class of insulation A, metallic body duly powder coated, designed for input Voltage range 240+-2.5% and output voltage range 240+-2.5%, Ratio 1:1, Vector Group : Dyn 11, eficiency more than 95%, Potential difference between neutral to earth less than one volt with all standard fittings, wall/floor mounted, indoor type all as specified and directed.
M & L Earthing with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip 32x6 mm as earth lead by means of G I bolts and nuts, check nuts and washers etc & connected to equipment and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia GI watering pipe and 40 mm dia light grade GI for protection of earth strip, wire mesh, funnel, charcoal dust & common salt, etc including necessary testing on completion all as specified and directed
M & L Galvanised iron strip 25 mm x4 mm for extending the earth continuity to the utility point / equipment including fixing properly on procelain insulators as required complete all as specified and directed.
M & L Copper strip 20 x 3 mm for inter connection of earthings and to connect the earthing to the main panel/equipment complete all as specified and directed.
Supply &Installation of Waterless and maintenance free Earthing (grounding) electrode of size Dia 85 mm x Length 3000 mm with 17 mm Cu bonded M S conductor in Pre cast in high purity electrically conductive granular (Marconite), having ultra low resistivity of 0.001 Ohm - m. (Provide the resistivity certificate for the same) Electrode made of electrically conductive granular mixed with cement to pre cast or backfill the voids surrounding the metal conductor in augured bore hole of 85 mm dia x 3000 mm depth, resulting in increase of effective surface area of the earth electrode and in case of high soil resistivity a grid of multiple electrodes to be installed to lower the desired earth resistance value, permanently with no further maintenance or periodic watering or recharge during it’s life of over 50 years in all type of soil including dry or rocky soils all as specified & directed
Earth enhancing material should not leach into the adjacent soil or underground water channels and it’s pH should be in neutral range and connected with copper strip 32mm x 6mm duly brazed and by means of bolts, nuts and washers upto 7.5 metre length with G I pipe of suitable dia for earth strip protection and connected to earthing test point, including provision of earth pit with necessary earth work, PCC 1:2:4 type B1 chamber, Cast iron frame with hinged pit cover of size 12” x 12” having not less than 7 kilogram of weight complete all as specified and directed and testing on completion.
Note:- (a) Earth enhancing material should permanently protect the encased metal conductor of corrosion. (b) Electrode's top terminal should be sealed permanently with the conductive concrete and extension strip taken out be terminated at earth bus bar. (c) Other hardware like nuts, bolts and washers should be of Copper. (d) Electrode should withstand fault current up to 30 kA for 1 second (Bidder Provide the certificate for the same). (e) Supplier of the Marconite Earthing Material should provide authorization letter from the Manufacturer for the Genuine material and also furnish certifications as per IEC 62516-7 & resistivity certificate confirming 0.001 ohm-m.
S & F PVC Cable ducts channel routing Standard Slotted Type A, specially designed profiles of duct and cover for fast and efficient locking of minimum encumbrance and maximum grip of size 45mm x 45mm complete all as specified and directed. Note:- All ducts are ROHS compliant and FRLS.
Supply and laying L T XLPE cable 3.5 core 120 sq mm, Insulated, screened, PVC bedded, galvanized steel strip or wire, armoured, electric power cables, heavy duty, 1100 Volts grade with stranded aluminium conductor including testing complete complete all as specified and directed.
Supply and laying L T XLPE cable 3.5 core 25 sq mm , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including testing complete all as specified and directed.
Supply and laying H T XLPE cable, 3 core 95 sq mm, insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor, 11000 volts grade complete all as specified and as directed
S & F Double walled corrugated HDPE Pipe IS-16205, size inner dia 103 mm, outer dia 120 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed.
S & F Double walled corrugated HDPE Pipe IS-16205, size inner dia 63 mm, outer dia 75 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed.
Excavation in trenches for laying underground cables, poles and stays in any type of soil not exceeding 1.5mtr wide and not exceeding 1.5 mtr deep and getting out all as specified and as directed.
All as per item No 27 here-in-before but exceeding 1.5 m deep and not exceeding 3.0 m deep.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cms thick all as specified and as directed.
Removing surplus excavated material to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point all as specified and as directed.
Cutting the tar macadam road / hard standings for laying cable and excavating not exe. 1.5 wide and 1.5m in depth and getting out all as directed including filing back and finishing it with PCC 1:2:4 type B-1 200mm thick all as specified and as directed.
M & L Galvanised Iron pipes 40 mm dia, light grade with all fitting and fixed to poles/route/drains, ceillings or laid in floors complete all as specified and as directed.
M & L Galvanised Iron pipes 80 mm dia, light grade with all fitting and fixed to poles/route/drains, ceillings or laid in floors complete all as specified and as directed.
Supply and erection 11 meter RCC pole, 152mm x 152mm mm at top and 152mm x 279mm at bottom, class 9, erecting in vertical position including cement base painting upto 1.2 mtr height from top of copping and then 03 nos of each black and yellow alternate strip of 20 cm complete all as specified and as directed.
M & L Plain cement concrete 1:4:8 type D-2, using 40 mm graded crushed stone aggregate as in foundation filling for poles complete all as specified and directed
M& L Providing cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in foundation filling for poles complete all as specified and as directed.
M & L Providing cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in coping around poles including necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and as directed.
M & L Anti climbing devices comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately) inclusive two coat of Aluminium paint over a coat of red oxide primer complete all as specified and as directed.
M & L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for H T 25x20 cm size complete all as specified and as directed.
M & L Mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and including two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fix lightening arrestor 11000 Volts, expulsion type, transmission class, discharge capacity 65 Kilo Amp complete with all fittings all as specified and as directed.
Supply and fix switch air break gang operated, triple pole, mechanically operated, mounted on insulators & steel frame with operation mechanism worked from ground level for current rating 200 Amps, 11000 volts and drop out expulsion fuse suitable for vertical mounting rotating type single pole 11000 volts, having 12 insulators of rating upto 200 Amps complete all as specified and as directed Note:- (a) GOD shall be vertical type. (b) Expulsion fuse should be set of three.
Supply, install, testing and commmisioning of outdoor type step down transformer of capacity 200 KVA copper wound HT 11 KV, 3 Phase, LT 433 volts, 3 Phase 4 wire, 50 Hz, ONAN cooled with 7 position off load tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group Dyn-11 all as per IS-1180 (Part-I) 2014 wtih energy efficiency level 2 with first filling of transformer oil and following accessories including necessary foundation and fencing with gate:- (a) LV cable box with cable glands (b) Name, Rating & Diagram Plate - 1 No (c) OFF circuit tap changing switch - 01 No (d) Earthing Terminals - 02 Nos (e) Lifting Lugs - 02 Nos (f) Oil level indicator (flush tube) - 01 No (g) Oil drain valve with plug - 01 No (h) Oil filter valve with plug - 01 No (j) Conservator with oil filling hole - 01 No (k) Thermometer pocket - 01 No (l) 4" dial type thermometer stem type - 01 No (m) Air release plug - 01 No (n) Silica gel breather - 01 No (o) Explosion vent - 01 No (p) Unidirectional rollers - 04 Nos
Note:- Quoted rate is deemed to be included the following work :- (i) Block masonary platform of size 1.5x1.5x1.2m above & 0.6m below GL on PCC 1:4:8 type D=2 foundation, Pre-cast cement concrete block masonary in CM 1:4,moorum filling & consolidating inside block masonary, sub base 75mm thick 1:3:6 type C-2, PCC 1:2:4 type B-2 100mm thick top, Plastering 15mm thick in CM 1:4 on walls , 3 coats white wash, 2 Nos supporting channels ISMC 100 of 1.2m long etc complete (ii) Any left out standard accessories which are not mentioned above and required for smooth functioning of the transformer
Supply, install, testing and commissioning of L T Feeder pillar Box 415 Volts AC, 50 HZ, 3 Phase, 4 wire, CPRI approved , internal wiring, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof, outdoor type, suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, 450 Amps electrical grade aluminium bus bar for phases and neutral, suitable digital type meters resin cast CTs, made out of 3.15 mm thick MS sheet, IP 54 protection, bottom cable entry with suitable cable glands, structure with angle iron 40x40x6mm frame work, four legs grouted into PCC (1:2:4) type B1 foundation block with double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, treated under 7 - tank metal treatment process and duly powder coated, suitable size to accomodating the following accessories complete all as specified and directed (LT Panel-1):-
Note:-(i) Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires (ii) Quoted rate is deemed to be included the all accessories such as MCCBs, voltmetrs, Ampere meter, indicators etc
Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm hard / dense soil all as specified & directed.
M & L Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde,-E-165 complete all as specified & directed.
M & L Preperation of new steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Demolition of Stone slabs and tiles, laid bedded & pointed in any mortar, of any description or thickness in floors, aprons etc. all as specified and directed.
M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and mirror polishing laid over & including cement mortar 20mm thick 1:6 screed base complete all as specified and directed.
Demolition of plain cement concrete in ground floors and pavings not exc 15cm thickness(below or above ground level) all as specified and directed
M & L complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M/s.GOODWILL ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .