| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18 LAccepted-AOC | ₹18 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹20.2 L+₹2.2 L (12.2%)Rejected-Finance 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹20.2 L+₹2.2 L (12.2%) | L2 | Rejected-Finance L2 Bidder |
| 3 | L3₹20.9 L+₹2.9 L (16.0%)Rejected-Finance | ₹20.9 L+₹2.9 L (16.0%) | L3 | Rejected-Finance L3 Bidder |
| 4 | L4₹23.4 L+₹5.4 L (30.2%)Rejected-Finance | ₹23.4 L+₹5.4 L (30.2%) | L4 | Rejected-Finance L4 Bidder |
| Sl No | Description | Qty | Unit | M/s.GOODWILL ELECTRICALS L4 | R. P. Suppliers and Construction Co. L2 | M/s PRATAP VIJAYSINGHRAO DESAI L3 | J.D INFRA ENGINEERING L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 m wide & not exc 1.5m in depth for laying under ground cables/erection of poles and getting out in hard/dense soil complete all as specified and directed. | 445 | Cum | 250 ₹1,11,250 | 200 ₹89,000 Lowest | 360 ₹1,60,200 | 350 ₹1,55,750 |
| 2.00 | All as per Srl item No.1 above but depth exc 1.5m but not exc 3.0 m | 1.22 | Cum | 300 ₹364.5 | 500 ₹607.5 | 450 ₹546.75 | 120 ₹145.8 Lowest |
| 3.00 | Returning , filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed | 431.71 | Cum | 25 ₹10,792.75 Lowest | 200 ₹86,342 | 60 ₹25,902.6 | 300 ₹1,29,513 |
| 4.00 | Removal of excated surplus material (soil) to a distance not exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed | 14.5 | Cum | 25 ₹362.5 Lowest | 300 ₹4,350 | 90 ₹1,305 | 200 ₹2,900 |
| 5.00 | M&L for duct pipe double wall, corrugated HDPE 50mm dia outer dia, conforming to IS:14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and as directed. | 1,600 | RM | 80 ₹1,28,000 | 40 ₹64,000 Lowest | 135 ₹2,16,000 | 150 ₹2,40,000 |
| 6.00 | M&L for plain cement concrete 1:4:8, type D2 (using 40mm graded crushed stone aggregates) as in foundation of poles and mass concrete complete all as specified and directed | 9.82 | Cum | 3,500 ₹34,370 | 2,000 ₹19,640 Lowest | 4,500 ₹44,190 | 2,000 ₹19,640 Lowest |
| 7.00 | Taking down/out unserviceable under ground cables of any cross sectional area and connections including bricks, GI pipes etc of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials viz bricks, cables, GI pipes complete all as specified and as directed. | 2,000 | RM | 2 ₹4,000 Lowest | 3 ₹6,000 | 6 ₹12,000 | 5 ₹10,000 |
| 8.00 | Supplying, laying or fixing or passing through pipe testing and commissioning of 1100 volts grade "Heavy duty" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 16 Sqmm nominal cross sectional area, 4 core confirming to IS specification complete all as specified and directed | 500 | RM | 190 ₹95,000 | 180 ₹90,000 | 180 ₹90,000 | 150 ₹75,000 Lowest |
| 9.00 | Supplying, laying or fixing or passing through pipe testing and commissioning of 1100 volts grade "Heavy duty" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 25 Sqmm nominal cross sectional area, 4 core confirming to IS specification complete all as specified and directed. | 400 | RM | 260 ₹1,04,000 | 200 ₹80,000 Lowest | 225 ₹90,000 | 230 ₹92,000 |
| 10.00 | Supplying, laying or fixing or passing through pipe, XLPE insulated, Armoured, Electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 06 Sqmm, 2 core including Brass compression cable gland, terminal lug etc and tesing completed all as specified and as directed.. | 700 | RM | 90 ₹63,000 | 115 ₹80,500 | 80 ₹56,000 | 50 ₹35,000 Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Mar 2026, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
REPLACEMENT/REPAIR AND MAINT OF STREET LIGHTS, TIMER SWITCH, UG CABLE, OLD PCC TO GI POLE AND ALLIED WORKS AT ATS UNDER GE(AF) SAMBRA
2026_MES_754443_1
GE(AF)/SAM/TOK-64 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE AF Sambra
₹50,000
Yes
4 May 2026
3 Mar 2026
30 Mar 2026
3 Mar 2026
25 Mar 2026
20 Mar 2026
Excavation in trenches not exc 1.5 m wide & not exc 1.5m in depth for laying under ground cables/erection of poles and getting out in hard/dense soil complete all as specified and directed.
All as per Srl item No.1 above but depth exc 1.5m but not exc 3.0 m
Returning , filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed
Removal of excated surplus material (soil) to a distance not exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed
M&L for duct pipe double wall, corrugated HDPE 50mm dia outer dia, conforming to IS:14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and as directed.
M&L for plain cement concrete 1:4:8, type D2 (using 40mm graded crushed stone aggregates) as in foundation of poles and mass concrete complete all as specified and directed
Taking down/out unserviceable under ground cables of any cross sectional area and connections including bricks, GI pipes etc of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials viz bricks, cables, GI pipes complete all as specified and as directed.
Supplying, laying or fixing or passing through pipe testing and commissioning of 1100 volts grade "Heavy duty" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 16 Sqmm nominal cross sectional area, 4 core confirming to IS specification complete all as specified and directed
Supplying, laying or fixing or passing through pipe testing and commissioning of 1100 volts grade "Heavy duty" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 25 Sqmm nominal cross sectional area, 4 core confirming to IS specification complete all as specified and directed.
Supplying, laying or fixing or passing through pipe, XLPE insulated, Armoured, Electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 06 Sqmm, 2 core including Brass compression cable gland, terminal lug etc and tesing completed all as specified and as directed..
M&L for LT cable, two core PVC insulated, PVC sheathed multi stranded copper conductor size 1.5 Sqmm for security light complete all as specified and directed
S&F in replacement thermo plastic cable junction box of size 300mmx200mmx105mm suitable for cable IP 65 protection including single phase and neutral aluminium bus bar with 10 amp MCB with metric knockout for cable entry incl MS clamp of size 25x3mm, incl 3 nos HDPE gland fixed on pole with clamp nuts, bolts, etc complete all as specified and directed
S&F in replacement street light luminaires 30 watt fitting New generation, (Nexus+) aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminium housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage 120 to 270 V 100 Lum/W complete all as specified and directed. Make: Crompton/Bajaj/Havells
S&F in replacement street light luminaires 60 watt fitting New generation, (Nexus+) aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminium housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage 120 to 270 V 100 Lum/W complete all as specified and directed. Make: Crompton/Bajaj/Havells
S&F in replacement street light luminaires 45 watt fitting New generation, (Nexus+) aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminium housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage 120 to 270 V 100 Lum/W complete all as specified and directed. Make: Crompton/Bajaj/Havells
S&F in replacement street light Luminaires 90 watt fitting New generation, (Hawk) aerodynamically designed with better thermal management for road lighting, having Pressure die cast aluminium housing powder coated in graphite grey and toughened glass, IP 66 protection, class I with operating voltage 120 to 270 V 100 Lum/W complete all as specified and directed. Make: Crompton/Bajaj/Havells
S&F in replacement LED Post top/ Gate light 1x40 watt decorative type, 360 indirect light including fixing with suitable size GI pipe as require on the top of the gate pillor, control by two way SP DB with suitable MCBs as per direction and wiring complete 100 Lum/W complete all as specified and directed. Make: Crompton/Bajaj/Havells
S&F in replacement Garden light/Bollard light 10 W pressure die casted powder coated housing with IP 66 prectection 100 Lum/W and driver complete all as specified and directed. Make:- Crompton LBLA3-10-CDL or equivalent make in Phillips/ Havells
S&F in replacement Flood light made up of pressure die casted aluminium housing with toughned glass and high power LED 120 W with IP 66 protection 100 Lum/W complete all as specified and directed. Make: Crompton/Phillips/ Havells/Bajaj.
S&F in replacement Flood light made up of pressure die casted aluminium housing with toughned glass and high power LED 200 W with IP 66 protection 100 Lum/W complete all as specified and directed. Make: Crompton/Phillips/ Havells/Bajaj.
S&F in replacement smart integrated solar all in one street light with more than 100 Lum/W PWM charger controller, LI Ion Battery. Mono Crystalline Solar panel PIR motion sensor easy installation 45 Watt including 50MM DIA POLE 7 MTR long with clamp,nut and bolt for mounting on pole complete all as specified and directed. Make: Crompton/Bajaj/Havells
S&F in replacement street light bracket fabricated out of GI tubing light grade 40 mm bore, bend to the shape as directed of length not less than 1.0 mtr complete with mounting MS clamp of flat iron size 40x5 mm of suitable length, 02 Nos incl nut bolt etc of suitable sizecomplete all as specified and directed.
Taking down Old /unsv/damaged PCC/steel pole complete with all accessories incl demolition of concrete with necessary excavation and earth work incl site clearence complete all as specified and as directed
S&F steel tubular swaged poles with cast iron base plate, final taper plug bolts, nuts, screws as specified type 410 SP-31 (9.0 Mtr long) incl embossing the manufacturers name and IS No of pole and erecting in position all as specified and directed incl painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat red oxide primer and painting of 30 cm wide red and white strips upto 1.5 mtr from bottom of the errected pole including marking of pole number complete all as specified and directed. Note: Necessary excavation, earth work and PCC shall be measured and paid for separately
S&F in replacement GI tubing medium grade ISI marked including all fititngs laid in trenches/fixed on wall of size 50mm bore complete all as specified and directed.
S&F in replacement including connecting and testing time switch panel box size 400mm x 350mm x 170mm dust and vermin proof made of 16 guage MS sheet factory made duly painted with two coats of synthetic enamel paint recommended colour over a coat of red oxide primer comprising the following:-
(a) MCB triple pole 32 Amps 230 Volts-01 No. (b) Analog electro mechanical time switch 24 hours with minimum setting 30 minutes for daily working contact rating 16 Amps, 240 volts, AC with initialcharging battery backup having supply and reserve failure upto 150 Amp hours and coil voltage 415 Volts. (c) AC contractror, 3 pole, ML-2 415 volt, 50 Hz(d) Internal wiring with PVC insulated stranded copper conductor of suitable size and making electric connection - 01 No (e) By pass MCB single pole, 32/40Amp, 230 volts- 01 No Note: Time switch pannel box shall be fixed on one pole/wallin feeder pillar box with flat iron clamp 40x6 mm or other suitable fixing arrangement
Taking down old /burnt LED street light driver from existing LED street light of 45 Watt from pole and supply and fixing new LED driver of existing make after making functional refixing it at the same pole complete all as specified and directed.
All as per Srl item No. 27 above but LED street light 60 Watt
All as per Srl item No. 27 above but LED street light 90 Watt
All as per Srl item No. 27 above but LED flood light 120 Watt
All as per Srl item No. 27 above but LED flood light 200 Watt
All as per Srl item No. 27 above but LED Gate light 36/40 Watt
S&F in replacement LED bulb30/ 45/60W 230V on street light pole complete all as specified and directed. Make- Havells,/Crompton/Phillips
Taking down carefully unserviceable Garden light/Street liight/Security light/High Mast light fitting from pole/structure and repair/replacement of worn out parts and carbon cleaning of fittings,cover,copper wire/aluminium wire,clamps ,nuts and bolts, mounting bracket and re assembling the same after repair,testing and refixing in pole/other location and repairing of cable /junction box / timer / contract L1 &L2 /MCB SPN/service wire including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of street light complete all as specefied and directed.
Note: (i) Replacement of defective spare parts of fitting (to make functional ) shall be measured and paid separately as supply only. However, cost of replacement screws, nuts, bolts, and cleaning of fittings shall be deemed to be included in quoted rate. (ii) Minor consumable material required to complete the job as (like tape, thimbles,, , electrical gloves, M seal etc) are included in quoted rates. (iii) Mobile no of superrvisor to be distributed. 24 hrs availability of supervisor and his electricians at Sub stn, complaint book to be maintained. (iv) Contractor shall be provide/depute sufficient number of electricians and helpers and vec (as directed by Enginerr-in-charge) to attend the complaints and rectified/replacement of parts, and the complaint shall be resolve within 24 hours of receipts of complaints.If contractor fails to attend &resolve the complain within 24 hours an recovery of Rs.100 par day /complaint shall be recovered from contractor dues. (v) contractor manpower shall attend dail to receive complaints at complaint cell at 9.00 a from JE E/M and report after completion of complaint and handover a complaint slip to JE E/M user signature as a record of attending the complaints for payment purpose
Taking down carefully unserviceable High Mast light fitting through lowering device from pole/Structure and repair/replacement of worn out parts and Clean lowering device, apply the grease or lubricate to lowering device. Test lowering devices and fully operate to fully down position. Serviceing the mechanical device (winch), check the oil level in gear box before operating winch and fill the gear oil (oil SAE 140 grade), Motor chains and sprockets should neither be too loose nor too tight, repair/fitting the high mast pole door compeletly functioning. Check all elements of the electrical system, Check pole cable insulation and connections for rust and cracks, Remove any unwanted elements such as bird nests, remove debris from around and inside the light pole; remove critter guard and remove any debris and restore critter guard; Mow, weed remove and tree trim as required; remove any soil buildup from around the pole and cleaning of fittings/replace of high mast/ flood light and, fuse hOld ers, photocells, ballasts, and other work required to keep the lights operational, proper connected/fitting copper wire/aluminium wire,clamps ,nuts and bolts at lower ring and re assembling the same after repair,testing and reposition in high mast pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of high mast light complete all as specefied directed by Engineer-in-Charge.
Note : (i) Replacement of defective spare parts of fitting (to make functional ) shall be measured and paid separately as supply only. However, cost of replacement screws, nuts, bolts, and cleaning of fittings shall be deemed to be included in quoted rate. (ii) Minor consumable material required to complete the job as (like tape, thimbles,, , electrical gloves, M seal etc) are included in quoted rates. (iii) Mobile no of superrvisor to be distributed. 24 hrs availability of supervisor ad his electricians at Sub stn, complaint book to be maintained. (iv) Contractor shall be provide/depute sufficient number of electricians and helpers and vec (as directed by Enginerr-in-charge) to attend the complaints and rectified/replacement of parts, and the complaint shall be resolve within 24 hours of receipts of complaints.If contractor fails to attend & resolve the complain within 24 hours an recovery of Rs.100 par day /complaint shall be recovered from contractor dues. (v) contractor manpower shall attend dail to receive complaints at complaint cell at 9.00 a from JE E/M and report after completion of complaint and handover a complaint slip to JE E/M user signature as a record of attending the complaints for payment purpose
M&L for PCC 1:3:6, type C-2 (using 40 mm grade stone aggregrates) as in foundation, mass concrate filling of poles & stay complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) as in coping for Old and new poles including form work and finishing the surfaces with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specified and as directed
S&F in replacement MNX40 power contactor 4 pole 3 phase 415 Volts , 40 Amps, coil voltage of rating 240 Volts including taking down Old unserviceable power contactor all as specified and as directed . Make:- L&T Cat No. CS94190 or equivalent in Siemens, GE
S&F in replacement MNX32 power contactor 4 pole 240 Volts,32 Amps , coil voltage of rating 240 Volts including taking down Old unserviceable power contactor all as specified and as directed. Make:- L&T Cat No. CS 94111 or equivalent in Siemens, GE
S&F MCB SPN 240 volts 6 to 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed. Make: Havelles/L&T/Legrand
S&F in replacement MCCB four pole 63 Amps with breaking capacity 16KA , 415 Volts, thermal & magnetic release including making all incoming/ outgoing connections fixed in repair complete all as specified and directed Make: Legrand/Siemens/Schneider
Supplying, laying, testing and commisioning LT UG XLPE insulated 1100 volt grade heavy duty cable multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and connecting up to the electrical system with suitable size of aluminium lugs of size 10 sqmm, 2 core complete all as specified and directed.
S&F in replacement LED aviation light luminaire , comprising of aluminium housing with polycarbonate enclosure including making necessary electric connection and mounting arrangement complete all as specified and directed Make:- Bajaj Model No-BGAV 302 LED/ Surya Model No- SLE SURYA SLEAL 54 LDR-SEN IP-65 /Kalin Model No- AOL/SE-15
M&L for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI wire 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected up to main DB/LT Panel /Test point and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) complete all as specified and directed.
M&L for preparation of old painted steel surface of LT poles and applying two coats of aluminium paint approx 6 mtr height on outer surfaces of pole from 1.5 m above the couping/ground level up to the top of steel poles including painting of MS cross arms, clamps, nuts and bolts etc and painting alternative black and white strips of 30 CM height with two coats of synthetic enamel paint up to 1.5 mtr height from the ground/couping level including writing pole No. with letters of size 25 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and as directed
Labour only for re-stretching properly sagged/loose ACSR conductor of any size fixed on LT poles by means of machine method to the permissible limit at different location including tightening of cross arms or D clamps and binding with new binding wire, tightening of jumpers complete all as specified and directed. Note: 1. Each line of conductor shall be measured and paid. 2. Rate including unwinding of Old winding wire and rewind with new binding wire after restretching
S&F in replacement insulator, shackle type, vitreous, porcelain, white, brown or green insulator for working pressure 1100 volts grade of 115 mm dia and 100 mm height including galvanised mild steel section of straps 31x5 mm and 14 mm dia insulator bolt, washers and nuts complete all as specified and directed.
S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator 1100 V grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia complete all as specified and directed
M&L for stay assembly complete with accessories as shown in electrical plate No: 1 using stay rod 20mm dia and 30x30x6mm stay plate, including painting to exposed surfaces of MS work with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed. Note : Stay clamps, PCC 1:3:6 and earth work shall be measured and paid separately
S&F Aluminium Conductor Steel Re-inforced of any sizes & shapes including taking down existing Old ACSR from PCC/Steel poles complete all as specified and directed
Excavation of road cutting by manually including making good the disturb surfaces after the completion of work with PCC 1:2:4 type B2 on top not less than 150 mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc complete all as specified and directed.
S&F in replacement thermoplastic cable junction boxes IP 55/IP 65 with metric knockout for cable entry with terminal of size 333X233X120 mm on pole with MS clamps, nut bolts, washers and glands suitable for 16 sqmm, 04 core cable complete all as specified and directed Make- Sintex Cat No GSJB 3020 or equivalent make as specifiedin list of makes of Particular Specifications
Cutting and trtmming of tree branches to clear the over head lines in the arc of LT over head lines (including repairing and jointing of ACSR Conductor if damaged during cutting of tree) and removing of the trimmed branches of trees,removing and depositing the same away from the site ,complete all as specified and directed. Note:-All tools and ladder required for the job should be arranged by the the contractor with the over all cost quoted in the item rate.pole to pole distance shall be measured as one span.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_845012.xls
BOQ • 3.47 MB
tender.pdf
Tender Documents • 1.03 MB
psiiLT.pdf
Additional Documents • 1.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .