| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹46.5 L+₹3.7 L (8.62%)Rejected-Finance 10 SANJAY HSG SOCIETY RACCA COLONY SHARANPUR ROAD NASHIK 422 002 | NASHIK | MAHARASHTRA | 422002 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹48.9 L+₹6.1 L (14.2%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹49.1 L+₹6.3 L (14.7%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹49.6 L+₹6.8 L (15.9%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
11 Jan 2021, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2020_MES_403638_1
83567/E8
Open Tender
Civil Works
Item Rate
180 days
NASIK
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE NASIK ROAD CAMP
₹98,000
Yes
18 Feb 2021
15 Dec 2020
13 Jan 2021
15 Dec 2020
11 Jan 2021
29 Dec 2020
16 Dec 2020 - 21 Dec 2020
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces finished even and smooth without using extra cement.
Rendering 10 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces finished even and smooth without using extra cement.
Rendering 5mm thick in cement mortar 1:3 on faces of brick work or concrete surfaces including roof projections and chhajjas upto first floor of building, surface finished even and smooth without using extra cement.
Preparing new plastered surfaces of walls and three coat of white wash.
Preparing new plastered surfaces and two coats of cement based paint over a coat of primer.
Preparing new plastered surfaces of ceiling and three coats of white wash
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar.
Machine cut kota stone slab flooring 20-25mm thick, laid over and including 20mm thick cement mortar screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
Kota stone slab 15-20mm thick in treads and riser of steps, skirting, dado and pillar laid over and including 15mm thick cement mortar screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L Granite (Telephonic black/Ruby red) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite 18 to 20mm thick. all as specified and directed.
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations.
Demolition of concrete in ground floors and pavings n exc 15cm thickness (below or above ground level).
Plaincement concrete type D-2, 1:4:8 (40mm graded aggreagate) 75mm thick in sub floors.
Rough dressed lime stone slab flooring 25 mm thickness laid bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 over and including 15 mm thick screed base in cement mortar 1:6 as specifed and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises.
Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm to 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick cement mortar as backing coat in cement mortar 1:4 complete all as specified and direted.
Non - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. laid over and including 15mm thick cement mortar screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match.
Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick cement mortar screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match.
Viritfied Ceramic tiles 10 mm thick (square/ rectangular) polished in skirting etc. cut out of tiles of area not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10 mm thick cement mortar backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match.
Taking down PVC waste, drain or rain water pipes upto 110mm bore.
Fixing only old 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints or with solvent cement including provision of fixing clamps as specified.
S & F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints or with solvent cement fixed to walls.
Fixing only old 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints or with solvent cement including provision of fixing clamps as specified.
S & F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints or jointed with solvent cement fixed to walls.
S & F in repairs 110mm bore PVC (SWR) bends any radius with rubber ring joints or jointed with solvent cement fixed to walls including cutting around for inserting into wall, roof slab etc. and sealing/making good to match the existing surface.
S & F in repairs 75mm bore PVC (SWR) bends any radius with rubber ring joints or jointed with solvent cement fixed to walls including cutting around for inserting into wall, roof slab etc. and sealing/making good to match the existing surface.
S & F in repairs 110mm bore PVC (SWR) bends provided with access door any radius with rubber ring joints or jointed with solvent cement fixed to walls including cutting around for inserting into wall, roof slab etc. and sealing/making good to match the existing surface.
S & F in repairs 75mm bore PVC (SWR) bends provided with access door any radius with rubber ring joints or jointed with solvent cement fixed to walls including cutting around for inserting into wall, roof slab etc. and sealing/making good to match the existing surface.
S & F in repairs 110mm bore PVC (SWR) branch piece provided with access door, single (single Y) equal or unequal with rubber ring joints or jointed with solvent cement fixed to walls including cutting around for inserting into wall, roof slab etc. and sealing/making good to match the existing surface.
S & F in repairs 75mm bore PVC (SWR) branch piece provided with access door, single (single Y) equal or unequal with rubber ring joints or jointed with solvent cement fixed to walls including cutting around for inserting into wall, roof slab etc. and sealing/making good to match the existing surface.
S & F in repairs 110mm bore PVC (SWR) junction single (Single T), provided with access door, equal or unequal with rubber ring joints or jointed with solvent cement fixed to walls including cutting around for inserting into wall, roof slab etc. and sealing/making good to match the existing surface.
S & F in repairs 75mm bore PVC (SWR) junction single (Single T), provided with access door, equal or unequal with rubber ring joints or jointed with solvent cement fixed to walls including cutting around for inserting into wall, roof slab etc. and sealing/making good to match the existing surface.
S & F in repairs 110mm bore PVC (SWR) vent cowl.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads.
Sheet glass, 3mm thick, ordinary quality and glazing with oil putty in square n exc 0.5sqm in each pane.
3mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane.
Dismantling boarding, any description, fixed in any position with nails/screw etc complete all as specified and directed.
M&L for 25 mm thick prelaminated MDF board interior grade,prelaminated one side with decorative choice lamination and other side with white lamination including necessary locking divice, catches suitable for kitchen cabinet and 0.45 mm thick PVC beading on all edges as in kitchen cabinet etc complete all as specified and directed.
M&L for 18 mm thick prelaminated MDF board interior grade,prelaminated one side with decorative choice lamination and other side with white lamination including necessary locking divice, catches suitable for kitchen cabinet and 0.45 mm thick PVC beading on all edges as in kitchen cabinet etc complete all as specified and directed.
Taking down Chowkhats with shutters ( without taking off shutters from the frames exc 1.5 Sqm each not exc 4 Sqm each
Taking down Chowkhats with shutters ( without taking off shutters from the frames (not exc 1.5 Sqm each).
Taking down shutters of any descriptin exc 1 Sqm and n. exc 2 Sqm each.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS suquare tube, suppling and fixing in opening as per specification and drawings .
S&F Factory Made Solid PVC Moulded Door Shutter, with particle board core 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 5mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC Sheet on back face and as directed by Engineer in-charge.
S and F 2nd class hardwood plain, solid, straight, chowkhats & frames, wrought,framed, rebated on the solid,rounded or champered,put togetherwith glue pinned at joints , supplied and fixed.
35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.
S&F 2nd class HW glazed and skelton shutters, 35mm thick made glazed and skelton shutter, open rebated and prepare to receive glass, gauze etc without sashbars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members as specified in SSR Part-I section 8, clause 8.24 (a) supplied and fitted to chowkats. all as specified and directed by Engr-in-Charge.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded.
Steel ventilator with top hung shutter including hinges, steel peg stay, complete.
Preparation of new or previously untreated steel or iron surfaces of any description over 10cm width or girth and two coats of synthetic enamel paint over a coat of red oxide primer.
S&F solid PVC frame of size 50 x 95 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS suare tube, with necessary arrangement for fixing of glass for louer type window / ventilator and additional PVC beading around the frame for fixing of wire mesh supplying and fixing in opening all as specified & directed (note :- Glazing / wiremesh shall be measure & paid separately).
Cutting holes in brick walls built in CM or cement lime mortar and stone walls built in lime mortar depth of embedded portion of hold fasts or lugs measured from the faces of jamb into the wall exc half brick but n.exc one brick for inserting hold fasts and making good dismantled portion incement mortar 1:3 or cement concret 1:2:4 type B-1 as required.
S&F mild steel hold fasts confirming to FE-290 Gde E165.
Preparing the surfaces of wood and wood based material, steel and iron work, new or old and treated with tar or coal tar black paint treating ends of pasts, backs of chowkhats etc area of tarred surface exc 0.1 Sqm each.
S&F 75mm size extruded brass handles, fabricated type polished
S&F for stainless steel cabinet hinge with spring, size 100 mm, suitable for modulor type cabinet for holding the shutter in shut/open position
S&F 100mm size extruded aluminium alloy handles, fabricated type, anodised
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised
S&F 75mm size butt hinges medium weight cold rolled mild steel
S&F 100mm size butt hinges medium weight cold rolled mild steel
S&F 75mm aluminium anodisd, barrel tower bolts of excturded section.
S&F100mm aluminium anodisd, barrel tower bolts of excturded section.
S&F 150mm aluminium anodisd, barrel tower bolts of excturded section.
S&F aluminium alloy,anodised, sliding door bolt with hash, staple(bolt type) and fixing clip of sheet,cast over exturded sectionand fixing bolt and sliding bolt of exturded section or cast alumimium alloy and fixing 300 mm length
S &F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aparture 1.40mm dia with stainless steel wire stapples/GI screws/wooden beadings etc all as specified and directed.
M/L painting to wood and wood base surface of any description not otherwise described, over 10 cm width or girth preparation of new surfaces, priming coat pink primer and two coat of synthetic enamelled paint
Dismantling water tanks exc 250 & n exc 500 ltr capacity.
Dismantling water tanks exc 500 & n exc 1000 ltr capacity.
Disconnecting existing tanks, exc 250 & n exc 500 setting aside (or lowering if required), cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position.
Taking up or down steel tubing and connections 15mm bore.
Taking up or down steel tubing and connections 20mm bore.
Taking down carefully existing bitumenous membrane/tarfelt treatment any description and cleaning and making good damaged surface in cement mortar 1:4 where ever required to make surface ready to receive fresh water proofing treatment on roof and flashing and junctions of parapet, kerb, wall etc. and removing rubbish out of defence land.
Demolition of concrete (unreinforced) of any description and in any position not otherwise specifically provided for.
Providing, cement concrete type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges.
Providing, cement concrete type B1 1:2:4 (20 mm graded aggregate) in steps, parapets and copings, kneelers, bases for water tanks, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork.
Waterproofing on roof including flashing and junctions of parapet, kerb, wall etc. as under:- (a) Applying bituminous primer on cleaned and dried surface @ 0.20 Kg/Sqm. (b) A coat of hot blown type bitumen of grade 85/25, applied hot at the rate of 2.25 kg/sqm. (c) Laying on primed surface by thermo fusion (torch application) 3mm thick APP based polymeric water proofing membrane weighing not less than 3.50kg/sqm and reinforced with polyester non woven fabric (not less than 150 gms/sqm). (d) Painting the exposed APP membrane surface with bituminous aluminium paint @ 0.15 Kg/Sqm.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 litre capacity, hoisted and fixed in position all as specified.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litre capacity, hoisted and fixed in position all as specified.
S & F ball valves, 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) fixed in repairs.
Fixing only in repair ball valves any bore or size.
Refixing old steel tubing and connections 15mm bore in new or old position (Walls, ceiling, floors, etc.)
Refixing old steel tubing and connections 20mm bore in new or old position (Walls, ceiling, floors, etc.)
15mm bore galvanised steel water tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors.
20mm bore galvanised steel water tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors.
S & F 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs.
S & F 20mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs.
Fixing only 15&20mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs.
S&F in repair Vitreous China water closet squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests and P trap (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding.
10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including flush pipe and brackets fixed in repairs.
Vitreous China wash down water closet (pedestal pattern), white including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete fixed in repairs.
Vitreous China wash basin white, flat back, size 550 X 400mm, including cutting for and pinning in ends of brackets or erecting stand, with and including 32mm waste fitting brass, chromium plated with long screwed shank and fly-nut, flange end bedded in red lead cement, brass chromium plated bottle trap with inlet and outlet screwed for pipe or connections 32mm bore, including necessary packing, union and cap and fixed in repairs.
Cast iron nahani trap 75mm dia of outlet, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
15mm bore bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repair.
S&F in repair hand shower (Health faucet) 1 Mtr PVC tube with wall hook (CP) complete all as specified and directed.
15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
15mm bore stop valves, cast copper alloy, fancy type, chromium plated (angle type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
PVC connections 15mm size with PTMT nuts of length 450mm
32mm bore low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm including fittings.
Brass chromium plated shower rose 125mm size with swivel joint, including fixing to steel pipe or union 15mm bore.
S&F in repair stainless steel drapery rod dia not less than 25mm and weight not less than 0.350Kg per RM, complete all as specified and directed.
Taking down aluminium door shutters of any description.
Taking down aluminium window shutters of any description.
Taking down aluminium door and window frame of any description.
Aluminium (minimum 50 micron powder coated) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
Aluminium (minimum 50 micron powder coated) door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
Aluminium (minimum 50 micron powder coated) window and ventilator shutters, side hung/sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.), rollers, grip etc. complete all as specified
5.5mm thick sheet glass plain or tinted, ordinary quality, fixed in aluminium doors and windows.
Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple or fixed in alumionium frames.
M&L for special treatment to sunken portion with 10mm thick plaster in CM 1:4 by using Ditachment DM 1% by weight of cement and surface made smooth after curing period two coat of Ditachment DS shall be applied @2.50 Kg/Sm. The paste like consistancy like is made by using 2.5 Kg of Ditachment DS powder in one litre of admixture (The admixture is made by dissolving 1 part by volume of Nafufill SBR & 4 part by volume of water). After 7 days curing, testing shall be done by flooring for 72 hours. Finally protective plaster coat of 10mm thick in CM 1:4 shall done by using Putz Ditachment 1% by weight of cement over layer of Detachment DS. All joints of CI Pipe, Nahani trap, WC connection etc. shall be filled by mixture of cement, fine sand and 10% Nafufill SBR by weight of cement 32mm dia 450mm long GI Spout light grade shall be provided in all sunken slabs to drain off water
Repairing broken edges of RCC chajjas, roof projections, fins, facia and similar works by dismantling of loose and damaged/ disintegrated portion of edges (cross sectional aerea not exceeding 100 sqcm) and cement mortar 1:4 or cement concrete 1:1½:3 type A0 and chicken wire mesh with nails (to hold fresh mortar/concrete) including necessary formwork etc. and scaffolding for work upto four storied buildings and finishing the surface by white wash or cement base paint to match the surface with existing work.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc ( Note - old serviceable switch /socket/ regulator/ switch-socket/ call bell/bell push shall be reused against apropriate items, all as specified and directed by Engr-in-Charge)
Taking down unserviceable/partly serviceable light fittings any type, tube light fitting and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes.(NOTE- old serviceable fitting shall be reused against apropriate items, all as specified and directed by Engr-in-Charge)
Taking down and refixing the ceiling fan/exhaust fan of any size and sweep in proper manner and connecting up including provision of cable from ceiling rose or connector to fan all as per specified and directed by Engr-in-Charge
Dismantling unserviceable main switch/DBs with MCBs and wooden board including making good disturbed surface of wall.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified .Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
(a) One light point controlled by one, one way switch
(b) One ceiling /exhaust fan point controlled by one switch and regulator
(c) One 3 pin 5 amp socket out point on the same board with other switches.
(d) One3 pin 5 amps socket out let point on independent board
(e) One bell/buzzer point controlled by one bell push.
All as per same in item No 119 above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
Material and labour for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface conduit not less then 20 mm, width with MS sheet metal sunken switch/Terminal box 1.2 mm thick or ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface wll / floor / roofs etc.complete all as specified and directed. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
(a) One light point controlled by one, one way switch
(b) One ceiling /exhaust fan point controlled by one switch and regulator
(c) One 3 pin 5 amp socket out point on the same board with other switches.
(d) One3 pin 5 amps socket out let point on independent board
(e) One bell/buzzer point controlled by one bell push.
All as per same in item No 121 above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
S &F Switch piano flush type single pole one way 5 amps.
S &F Socket out let 2 in one, 5/3 pin 5Amp
S &F Switch socket combination 5 Amps 5 pin flush type
S &F Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal .
S &F Ceiling rose, surface bakelite 65x50 mm three terminal
S &F Call bell AC-230 Volt single pole ding dong
S &F Bell push, flush type 5 Amps.
S &F Electronic regulator 100/120 Watt step type
Supply and fixing of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED bulb 9 watt.
Supply & fix LED down lighter, 12W including cutting of ceiling cutout and connecting up with twin core twisted flexible copper conductor cable of suitable size, 230V, 50Hz, complete all as specified and directed by Engr-in-Charge. Make: Crompton Cat Part No-LSDRMN-12W-CDL or eqvt in Bajaj/Havells/Philips
Supply & fix LED down lighter, 15W including cutting of ceiling cutout and connecting up with twin core twisted flexible copper conductor cable of suitable size, 230V, 50Hz, complete all as specified and directed by Engr-in-Charge. Make: Crompton Cat Part No-LSDRMN-15W-CDL or eqvt in Bajaj/Havells/Philips
S & F 20 Watt Batten (4 feet) suitable for LED T8 lamps including coneecting up with 2 core flexible coppper conductor cable and mounting clamps & PVC squre box 75x75mm - 2 Nos etc, all as specified and directed by Engr-in-Charge. Havells Cat Part No-REGALBATTENT 8UPTO1X22WDSBSWH or eqvt in Bajaj/Crompton/Philips
S & F 20 Watt LED Tube Light (4 feet) suitable for T8 Batten including provision of suitable type of bipin holders- 02 Nos for each fitting, internal wiring of old fitings/fixtures if required, all as specified and directed by Engr-in-Charge. Havells Cat Part No-CRYSTAL 1213T8DSTL20WLED865SGLASS or eqvt in Bajaj/Crompton/Philips
Supply & fix LED down lighter,6 W including cutting of ceiling cutout and connecting up with twin core twisted flexible copper conductor cable of suitable size, 230V, 50Hz, complete all as specified and directed by Engr-in-Charge. Make: Crompton Cat Part No-LSDRMN-6W-CDL or eqvt in Bajaj/Havells/Philips
Supply & fix LED down lighter, 9W including cutting of ceiling cutout and connecting up with twin core twisted flexible copper conductor cable of suitable size, 230V, 50Hz, complete all as specified and directed by Engr-in-Charge. Make: Havells Cat Part No-LHEBHDP7IZ1W009 or eqvt in Bajaj/Crompton/Philips
Supply and fix in repaires POLARIS NIO - I LED recessed full lit luminaire with glare free uniform illumination with longer life and less maintenance. (Make - Crompton Cat part No- LCTLRNE-36-FO-CDL, or eqt of Havells/ Bajaj / Philips)
Supply and fix in repaires VENUS NEO HE 2X2 ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination with its driver Cat No-LEDDRIVER36V18WS . Make - Havells Cat part No- VENUSNEOHE2X2PLR18-42WLED857MOD anddriver Cat No-LEDDRIVER36V18WS or eqt of Crompton/ Bajaj / Philips)
Supply & fix LED tube light along with fixture,10 W, 2 Feet including coneecting up with 2 core flexible coppper conductor cable and mounting clamps & PVC squre box 75x75mm - 2 Nos etc, all as specified and directed by Engr-in-Charge. Havells Cat No-LHEXACP7IN1W010 or eqvt of Crompton/ Bajaj / Philips)
Refixing of tube light from exisiting position to new position as required at site all as directed and specified . (Note:- The old serviceable fittings will be used as removed against item No-2 above)
Refixing of wooden/PVC rectangular block for mounting, switches, sockets,fan regulator, call bell, bell push etc. with 3 mm thick plastic laminated sheet cover/helum sheet of ISI mark as required on ground including casing capping /conduit of any size, all as specified and directed by Engr-in-Charge. (The old serviceable material will be used as removed against item No-1 above)
Refixing of DB's including MCB's of any size, all as specified and directed by Engr-in-Charge. Note:- The material shall be used as removed against item No 4.
Supply and fix LED security/street light 15 W IP 65 , including coneecting up with 2/3 core flexible coppper conductor cable , compete all as specified and directed by Engr-in-Charge. Havells Cat Part No-ENDURAPEARLSL15WLED757SASYTOPCMP or eqvt of Crompton/ Bajaj / Philips
Fabrication,supply & fixing of GI pipe bracket up to 40 mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 12/15 w LED security light fitting
S & F in repair 1X18W LED PL-Lamp suited for installation in existing 2G11 lamp holders including connecting up with twin core twisted flexible copper conductor cable, holders with suitable size, internal wiring of fittings , 230V, 50Hz, complete all as specified. Havells Cat Part No PHOTONULTRA PLL419TL18WLED865SPC or eqvt in Bajaj/Crompton/Philips
Taking down and fixing partly unserviceable surface/recess mounted LED fittings of any make and size for necessary repair including ractifing any kind of electronic disorder/Circuit disorder/replacement of LED strip/all other accessories and make it serviceable , complete all specified and directed by Engr-in-Charge. Note: (1) Ladder to be provided by contractor. (2) Spare i.e driver shall be measured seperately.
S & F in repair electronic driver upto 42W Watt suitable for surface/recess mounted LED fittings of any make and type, all as specified and directed by Engr-in-Charge.
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC CASING CAPING not less then 25mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing and one run of PVC casing/caping shall be measured as one unit.
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC conduit not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing and one run of PVC conduit shall be measured as one unit.
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through and including PVC casing capping not less then 25mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing and one run of PVC casing capping shall be measured as one unit.
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC CASING CAPPING not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 6 sqmm and one wire of 6 sqmm and one run of PVC casing capping shall be measured as one unit.
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through exsisting steel conduit any make and type fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing shall be measured as one unit.
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through exsisting steel conduit any make and type fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing shall be measured as one unit.
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through exsisting steel conduit any make and type fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 6 sqmm and one wire of 6 sqmm for earthing shall be measured as one unit.
S & F 4 way MCCB powerline vertical DBs in double door suitable for TP/FP MCCB, bus bar with current rating capacity upto 160A, IP-43-IK09 protection grade complete all as specified and directed by Engr-in-Charge, Make:- Standard Cat Part No-DSDPVDIBEOTO04 or eqvt in Legrand/L&T/Havells
S & F in repair for MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415 Volts TPN with 4 way Double door including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed
S&F in repair Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 12 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S & F in repair, MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail , 240Volts SPN with 8 way Double door , IP-43-IK09 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed
S & F in repair MCB DB made of sheet steel enclosures with detachable gland plates for flush/surface mounting with bus bars, neutral links and earth bar (without mcbs) , 240Volts SPN with 6 way Double door , IP-42 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed. Make- Standard Cat Part No-DSDNSHODXW06 or eqvt in Legrand/L&T/Havells
S & F in repair MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 240 Volts SPN with 4 way Double door IP-43-IK09 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed
Supply and fix in repair for MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
Supply and fix in repair for MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
Supply and fix in repair for MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 32-40 Amps
Supply and fix in repair for MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
S & F in repair MCCB TPN 63 Amps , 415Volts, 25KA ,4 pole. of Make - legrand , Cat part no. 4200 53 or eqvt in Standard/L&T/Havells
S & F in repair MCCB TPN 100Amps , 415Volts, 25KA ,4 pole of Make - LEGRAND, Cat part no. 4200 55 or eqvt in Standard/L&T/Havells
Taking down and fixing partly unserviceable LED security light fittings (building) of any make and type for necessary repair including ractifing any kind of electronic disorder/Circuit disorder/replacement of LED strip/all other accessories and make it serviceable , complete all specified and directed by Engr-in-Charge. Note: (1) Ladder to be provided by contractor. (2) Spare i.e driver shall be measured seperately.
S & F in repair electronic driver 12/15 Watt suitable for security light fittings new generation energy saving and environmental friendly long life LED street light/building security light of any make and type, all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in gound (Earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earht strip protected by provision of GI light grade pipe 15 mm light grade bore including provision of pit in PCC (1:2:4) type B-1 using 20 mm graded of stone aggregate with PCC cover including 20mm bore pipe for wetering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal (not less than 40 Kgs, 80 Kgs each) filling with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electircal plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
M/S SAMEER SUBHASH PATANI
M/S GURBAX AND CO
M/s. JBSR ENTERPRISES.
JEET CONSTRUCTIONS CO.
M/S MANISH CONSTRUCTION CO
Vishal Constructions
M/S K. K. Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .