Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹24.1 L+₹1.3 L (5.67%)Rejected-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L2 | Rejected-Finance L1 BEING ACCEPTED | |
| 3 | L3₹25.4 L+₹2.7 L (11.7%)Rejected-Finance | L3 | Rejected-Finance L1 BEING ACCEPTED |
Tender Value
₹22.9 L
EMD Value
₹45,800
Closing Date
3 Apr 2023, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
Repair / Routine Maintenance Fire Alarm system and Fire Fighting Installations EOT/HOT cranes, AMC for cranes and Automatic gate for hanger at AGE B/R Mandapam ,Maint/Repair/Repalcement of External Electrification,HT/LT Panel, VCB/OCB, Transformer,
2023_MES_585728_1
8024/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹45,800
Yes
27 Apr 2023
14 Mar 2023
5 Apr 2023
14 Mar 2023
3 Apr 2023
21 Mar 2023
Amount
Preventive and Break down maintenance comprehensive in nature for electrically operated flame proof EOT crane of 3 Ton capacity capacity floor operated, comprising of Hoist motor, Long travel motor, Cross travel motor, Gear box, Control panel and other connected accessories installed at IC Workshop
Preventive and Break down maintenance comprehensive in nature for manualy opearated HOT crane of 1 Ton capacity capacity floor operated, comprising of other connected accessories installed at new Workshop Building.
NOTE FOR ITEM NO 1 & 2 :- (i) Quoted unit rate is comprehensive in nature and deemed to include to attend the break down any number of times as and when required by user including replacement of any type nature spare parts including rewinding of any type of motor. (ii) The unit rate quotated by the tenderer is deemed to be included in the cost of grease, cotton waste, lugs, small piece of wire/cables, nut, bolt and washers and T&P etc complete. (iii) Contractor must employ minimum one crane mechanic 3 days in a week having electrical knowledge and minimum five years experience and the cost deemed to be included in the rate quoted by the contractor. (iv) These items shall be measured only when carrying out the maintenance alongwith documents to be submitted duly signed by Engineer-in-Charge. Log sheet, Daily Maint, Weekly maint and monthly maint records must be maintained as directed by GE.
Material and labour for carrying out load test on EOT Crane 03 Ton capacity with 110% of full load capacity of crane on hoisting long travel and cross travel for checking the performance including loading and unloading and returning the test loads obtained from the concerned unit/firm and submission of test certificate to the department
Material and labour for carrying out load test on HOT Crane of 01 Ton capacity with 110% of full load capacity of crane on hoisting long travel and cross travel for checking the performance including loading and unloading and returning the test loads obtained from the concerned unit/firm and submission of test certificate to the department
NOTE FOR ITEM NO 3 & 4 :- The Unit Rate quoted by the tenderer shall be inclusive of the cost for arranging the load & load testing of each crane as recommended by manufacturer at 110% of its capacity from authorised/recognised by State/Central Govt agencies and testing to be carried out once during the current year contract.
Supply & Fix addressable type multi sensor Detector with a combination of both heat and smoke type detection arrangement complete as required UL listed NEPA 72 E compliance all as directed. Make : Notifier/Morley IAS/RAVEL/Honeywell
Supply & Fix of Manual push button to initiate audio alarm resetable, intelligent and addressable type enclose in a sturdy box complete as required UL listed compliance all as directed Make : Notifier/Morley IAS/RAVEL/Honeywell
Supply & Fix addressable type fire alarm Hooter cum strobe complete as required and suitable for wall/ceiling mounting and UL listed NFPA 72 E complete all as directed. Make : Notifier/Morley IAS/RAVEL/Honeywell
Supply & Fix intellegent analog addressable short circuit/Fault isolator modules including all acessories like juction boxes, glands, terminating lugs as required and as per specification and UL listed NFPA 72 E compliance. Make : Notifier/Morley IAS/RAVEL/Honeywell
Supply & Fix Remote response indication addressable detectors all as directed. Make : Notifier/Morley IAS/RAVEL/Honeywell
Supply & Fix Copper FRLS cable 2x2.5 sqmm ISI marked with proper clamping, supports and terminations all as directed Make: Finolex/Polycab/Havells
Supply & Fix Rigid Steel conduit -25 mm dia stove enameled , on wall/ceiling etc. with proper clamping, supports.
Supply & Fix Data card for interconnection and communication between fire alaram panels all as directed.
Supply & Fix Fire Extinguisher Class K Type 4 kg Capacity, MS Cylinder, Nitrogen expellent, Discharge range more than 02 meter. Make : VariEx Mode Class K Type : VFE-4K
Supply & Fix Fire Extinguisher CO2 Type 4.5 kg Capacity, MS Cylinder Make: Finolex/Polycab/Havells
Periodical maintenance and servicing of Fire alarm control panel, single loop panel at Technical Building including 99 detectors & 99 modules in a system etc, complete by making regular servicing of the system to ensure proper functioning including replacement of spare materials all as directed by Engineer-in-charge.
Periodical maintenance and servicing of Fire alarm control panel, single loop panel at HMU Workshop Building ncluding 99 detectors & 99 modules in a system etc, complete by making regular servicing of the system to ensure proper functioning including replacement of spare materials all as directed by Engineer-in-charge.
Periodical maintenance and servicing of Fire Alarm control panel, double loop panel at Technical Building including 199 detectors & 199 modules in a system and Repeater panel at Hanger, complete by making regular servicing of the system to ensure proper functioning including replacement of spare materials all as directed by Engineer-in-charge.
NOTE FOR ITEM NO 15,16 & 17 :- (i) Quoted unit rate is comprehensive in nature and deemed to include to attend the break down or any type faults showng in panels, modules and detectores, password resetting etc in any number of times as and when required by user including replacement of any type nature spare parts. (ii) The unit rate quotated by the tenderer is deemed to be included in the cost of minor parts and T&P etc complete. (iv) These items shall be measured only when carrying out the maintenance alongwith documents to be submitted duly signed by Engineer-in-Charge. Monthly maint records must be maintained as directed by GE.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of stays, laying cables etc and getting out in soft / loose soil complete all as specified and as directed
Supply, lay , spread in trenches, river sand including cleaning, spreading, levelling, punning for laying /cushioning of cable complete all as specified and as directed. Note: Punning thickness shall be measured and paid.
Supply, lay in trenches burnt Bricks, old size, Sub class "B" for cable protection complete all as specified and as directed.
Removing excavated surplus soil not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm using excavted soil complete all as specified and as directed.
Removing the old unserviceable LT UG cable including lugs and glands and taken as credit including supply and Lay in trenches/poles/wall etc LT UG Cable XLPE insulated sheathed with multistranded aluminium conductor armoured with galvanised steel wire /taps 1100 volts grade conforming to IS specifications and of following sizes:-Make:Gloster/Polycab/Nicco
LT UG Cable of size 4.0 Core 10 sqmm.
LT UG Cable of size 4.0 Core 25 sqmm..
LT UG Cable of size 3.5 Core 35 sqmm
LT UG Cable of size 3,5 Core 70 sqmm
LT UG Cable of size 3.5 Core 120 sqmm
LT UG Cable of size 3.5 Core 185 sqmm
Taking out from trenches/poles/wall etc LT XLPE UG Cable /PVC Sheathed aluminium conductor armoured during emegency break down times, attending and rectifying break down immediately and relaying after fault rectification duly tested in trenches/Poles/Wall of HT/LT UG Cable size of any size complete all as specified and as directed. Note:(1) Attending break down immediately, rectifying the cable fault, testing etc are inclusive of the rate quoted under this item. (2) Earth Work and excavation , Jointing Kit will be measured and paid separatly under relevent Items.
Material and labour for cutting the existing bituminous road / cement concrete surface 150 mm thick to the required width and depth for laying pipe lines and making good the disturbed area to match with the existing surface complete all as specified and as directed.
Supply and fix Straight through joints (epoxy) for underground cable including joint kits and labour complete for making joints suitable for LT PVC sheathed / armoured heavy duty cables with aluminium conductor of following sizes :-
LT UG cable of size 4 core up to 16 sq mm, Make Denson/M seal/siemens
LT UG cable of size 3.5 core 25 to 50 sq mm, Make Denson/M seal /siemens
LT UG cable of size 3.5 core 70 to 150 sq mm, Make Denson/M seal/siemens
LT UG cable of size 3.5 core185 to 300 sq mm, Make Denson/M seal /siemens
Supply and lay 50 mm dia steel water tubing galvanised medium grade including all fittings such as bends belows tee, unions, sockets etc laid in trenches for drawing cables under road/drain crossing etc complete all as specified and as directed. Make- TATA/Jindal/Zenith with ISI marked.
Supply and lay 80 mm dia steel water tubing galvanised medium grade including all fittings such as bends belows tee, unions, sockets etc laid in trenches for drawing cables under road/drain crossing etc complete all as specified and as directed. Make- TATA/Jindal/Zenith with ISI marked.
Repair and welding the existing panel board door and provide MS hinges for door and lock arrangement with a provision of pad lock with keys and making good the electric connection, wirings, PROVIDING or REPLACING CABLE LUGS OF SUIITABLE SIZE and cleaning the welding surfaces by rubbing and painting with one coat of synthetic enamel paint complete all is specified and as directed.
Supply and Replacement of MCCB 4 POLE with breaking capacity 35 KA 415 volts Adjustable thermal & adjustable magnetic setting directly fixed to board/panel /walls complete all as specified and directed of following capacitiesMake: Siemen/Schneider/ABB
Supply and Replacement of MCCB 3 POLE 415 volts Adjustable type directly fixing to board/panel /walls all as specified and directed of following capacitiesMake: Siemen/Schneider/ABB
125 Amps with breaking capacity 25 KA
100 Amps with breaking capacity 25 KA
Supply and Replacement of MCB TPN 415 volts C Curve directly fixed to board/panel /walls completeall as specified and as directed of following capacitiesMake: Siemen/Schneider/ABB
Supply and Replacement of Following capacitors in Power Factor correction panel:
5 Kvar Capacitor Make: Epcos/Crompton Greaves/L&T
3 Kvar Capacitor Make: Epcos/Crompton Greaves/L&T
1 Kvar Capacitor Make:Epcos/Crompton Greaves/L&T
10 Kvar Capacitor Make: Epcos/Crompton Greaves/L&T
Supply and Replacement of Change Over Switch of the following Amps : Make:ABB/L&T/GE
Supply and Replacement of Current Tranformer of the following Amps Make;Alstom/Kappa/AE
Supply and fix Aluminium Cable lugs suitable for cable of following sizes
3.5 Core 120 to 185 sq mm
3.5 Core 50 to 90sq mm
3.5 Core 16 to 35 sq mm
Supply only Transformer oil
Supply and fix Breather for transfomer up to 500 KVA
Supply and fix Polymer Type Insulators for 2 pole structure(ISI Marked) Note: Make:
M & L for draining out of transformer oil complete & dismantling of 500KVA transformer complete for replacement of gasket all around and assembling of all the dismantled parts with new nuts and bolts etc, refilling of filtered oil including filtration of oil , checking of HT and LT connections including testing with megger complete all as specified and as directed by Engg-in-Charge. Note: Rate includes filtration of existing transformer oil, topping up of extra tranformer oil will be paid separately
M & L for draining out of transformer oil complete & dismantling of 250KVA mobile transformer complete for replacement of gasket all around and assembling of all the dismantled parts with new nuts and bolts etc, refilling of filtered oil including filtration of oil , checking of HT and LT connections including testing with megger complete all as specified and as directed by Engg-in-Charge. Note: Rate includes filtration of existing transformer oil, topping up of extra tranformer oil will be paid separately
Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 2mm dia galvanised iron or steel wire complete and all as specifed and as directed .
Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth iead wire 4mm dia by means of bolts,nuts check nuts and washers of GI all as shown in electric plate No 3 connecting to earthing test point including necssary exacavation in any earth strata , PCC chambers in PCC 1:3:6 type C1, RCC 1:2:4 type B1 cover slab 50mm thick with 8 mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle watering pipe of GI 20 mm dia medium grade, funnels, lug and charcol,salt etc all as applicable and as per plate No 3 of SSR part 1 connecting test point and testing on completion complete and all as specifed and as directed . Notes:-The rates quoted is inclusive of galvanised earth lead wire 4mm dia conductor upto a length of 7.5m from the earth pit.
Supply and fix electrical insulating mate HT 22 KV grade of size 2mx1mx3mm thick confirms to IS: 15652:2006 including taking down u/s rubber mate and taken as credit complete all as specified
Supply only Digital AC/DC clamp meter with standard measuring capacities AC/DC Voltage/current. Resistance compelete. Make Meco Model: 1080/IMP/AE
Material & Labour for Cross arms,Bracing,Supports,clamps and back plates fabricated of mild steel as required/ directed to the shape required for fixing to steel tubular pole/pole structures or required at any location of flood street light distribution system fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including preparation and applying two coats of synthetic enamel paint over a coat of oxide primer complete all as directed.
Material & Labour for replacement of Meter box at ICGS 2 pole structure with dimentions (0.7m x 0.7m x 1.0m) made of CRCA sheet 2.0mm thichness complete with 2 partitions of top and bottom, transparent glass cutting on top portion for visibility of meter readings inside the box complete same as existing meter box including hinged doors for opening and closing, rubber washers for water proofing complete including taking down of old meter box and replacing all nuts, bolts, washers, welding, bending cold or hot, drilling holes & fixing with bolts to the 2 pole structure in any shape or size as indicated or directed including preparation and applaying RAL coat paint for anti corrosion complete all as directed.
Servicing/Comprehesive maintenace of DG set of 250 KVA capacity ,kirloskar Make Including servicing of all parts as per maintenace manual, replacement of filters, coolant, engine oil, belts etc,and attending breakdown as and when requried complete all as specified and as directed. (NOTE: Spare Parts and consumables shall be measured and paid seperately)
Servicing/Comprehesive maintenace of DG set of 200 KVA capacity ,kirloskar Make Including servicing of all parts as per maintenace manual, replacement of filters, coolant, engine oil, belts etc,and attending breakdown as and when requried complete all as specified and as directed. (NOTE: Spare Parts and consumables shall be measured and paid seperately)
Servicing/Comprehesive maintenace of DG set of 15 KVA to 50 KVA capacity ,kirloskar Make Including servicing of all parts as per maintenace manual, replacement of filters, coolant, engine oil, belts etc,and attending breakdown as and when requried complete all as specified and as directed. (NOTE: Spare Parts and consumables shall be measured and paid seperately)
Supply only Automatic Battery Charger for 12 Volt 10A Make:Greaves power/Mahindra/Ashok leyland
Supply of fuel filters, Lub oil filters for 250 KVA DG Set Make:Greaves power/Mahindra/Ashok leyland
Supply of fuel filters, Lub oil filters for 200 KVA DG Set Make:Greaves power/Mahindra/Ashok leyland
Supply of fuel filters, Lub oil filters for 40KVA/50 KVA DG Set Make:Greaves power/Mahindra/Ashok leyland
Supply of fuel filters, Lub oil filters for 25 KVA DG Set Make:Greaves power/Mahindra/Ashok leyland
Supply of fuel filters, Lub oil filters for 15 KVA DG Set Make:Greaves power/Mahindra/Ashok leyland
Supply and fix V belt for DG Set as per exisitng size
Supply only cotton waste for cleaning
Supply and fix PVC transparent pipe 8mm bore dia and 2 mm thick for fuel lines
Supply and fix Asbestos rope 10mm dia wound on exhaust pipe
S & F Copper Washer for fuel line Hose
Supply and Fix battery lead with flexible copper conductors PVC insulated of size single core 50sqmm suitable for 24 volts batteries.Make:Finolex/Polycab/RR Kabel
Supply and Fix battery terminal clamp with bolts and nuts , brass suitable for 50 sqmm single core copper multistranded cable for 12V, upto 180 AH battery terminal posts.
Material and Labour for self motor complete dismantling press kit cut out, armature polishing checking testing complete for 200 KVA DG Set
Material and Labour of Preparation of old painted steel surface of DG Set and applying one coat of synthetic enamel paint for 200 KVA Genset complete all as specified and as directed
Material and Labour of Preparation of old painted steel surface of DG Set and applying one coat of synthetic enamel paint for 40 KVA Genset complete all as specified and as directed
Material and Labour of Preparation of old painted steel surface of DG Set and applying one coat of synthetic enamel paint for 25 KVA Genset complete all as specified and as directed
Supply and replacement of old unserviceable dynamo assembly of existing 200 KVA capacity with new one complete all as specified and as directed.
Material and Labour for Removing Radiator Completely of 200 KVA DG Set, Acid Cleaning , water servicing , packing assembly fitting welding work and refilling checking turbo raditor servicing pressure testing and reassembling complete all as specified and as directed.
Supply and Replacement of unserviceable battery 12 Volts, 180AH with new one complete all as specified and as directed. Make: Exide
Supply and Replacement of unserviceable battery 12 Volts, 100AH with new one complete all as specified and as directed. Make: Exide
Supply and Replacement of AVR for 200 KVA/250 KVA DG Set with new one complete all as specified and as directed.
Supply and Replacement of AVR for 15 KVA to 50 KVA DG Set with new one complete all as specified and as directed.
Material and Labour for Removing/rewinding/refixing of alternator rotor assembly for 15 KVA DG set including replacement of minor spares complete all as specified and as directed.
Materil and Labour for Removing/refixing and servicing of cylinder heads, valve, valve guides, valve steel exhaust assembly, stem seal, facing , Lapping after making proper boring to seal the oil leakage for 200 KVA DG set including replacement of minor spares complete all as specified and as directed
Supply and replacement of Cylinder heads after removing the old unservicable cylinder head for 200 KVA DG Set including replacement of minor spares complete all as specified and as directed.
Supply only High grade Engine oil suitable for DG sets upto 200 KVA .Make :Servo/Greaves power/Mahindra
Supply only coolant oil heavy duty suitable for DG set complete all as specified and as directed.Make:Servo/Greaves power/Mahindra
Supply only distilled water for battery.
Supply and replace insulator set at the junction of alternator and supply output cables, for 200KVA Dg set including replacement of nuts and bolts with washer complete all as specified and as directed
Supply and replace thermal/ temparature sensor for 50KVA DG set of Make: Greeves power
M & L for attending of cable fault, trimming of cable near junction boxes of street light pole by cutting uninsulated part of cable near junction boxes, reconnection of cable complete with lugs, cleaning of pole coping and making of proper looping of extra cable complete all as specified and as directed. Note: Cable lugs will be mesaured separately
Supply only aluminium Cable lugs of suitable size from 10Smm to 35Sqmm.
Supply and replace junction box clamps of a PCC pole of any size complete including proper bending, making of holes as per requirement of junction box taking down of old clamps and fitting new clamps with bolts and nuts, painting with 2 coats of anti corrosive paint all as specified and directed by Engg-in-Charge.
Supply only the following items to incorporate in street light fittings included vide item 115, here-in-before.
(a) Driver for LED Light driver 60W/90W watts LED street light fitiing
Supply and fix 60 Watts LED street light with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection luminaire with high power LED 60 watts including removing old unsv fitting all as directed by Engr-in-charge Make: Phillips, Model : BRP062 LED 65 CW LSA S1 PSU or equivalent in Bajaj, Havells approved by GE.
Supply only for replacement of (bracket) 40 mm dia GI pipe light grade,1.5 mtr long, 30 degree bent to shape and fixed with 40 x 6 mm flat iron clamp-02 Nos suitable size of nuts and bolts of GI etc on poles complete all as specified and directed .
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armuored, electric power cables (heavy duty) 1100 Volts grade with Stranded aluminium conductor of size 4 core 25 Sqmm inlcluding taking down of old unservicaeble UG cable all as directed
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armuored, electric power cables (heavy duty) 1100 Volts grade with Stranded aluminium conductor of size 4 core 10 Sqmm inlcluding taking down of old unservicaeble UG cable all as directed
Supply and fix twin core 4 Sq mm multi stranded copper conductor PVC insulated and sheathed cable to connect fron junction box to street light fitting through PVC Conduit / Pole inluding taking down old unservicable cabve of any size and any type from pole ( Rate of PVC Conduit shall meaured and paid seperately)
Supply and fix PVC Conduit 20 mm bore medium grade with all fitting and provide minimum 3 Nos clamping arrangement to fix with street light poles
Supply and Fix Integral decorative 8 Watt LED bollard with opal acrylic and IP65 Protection 8 watts fixing bollard light with bolts, nuts and connecting with twin core with PVC junction box including removing old garden lights all as directed by Engr-in ChargeMake : Philips Model: BAMBOOBLS8WLED830PSYMTOPC or equivalent in bajaj/havells/ CG
Supply and Fix PVC junction box of size 205x255x112 mm including removing old unsv box all as dirceted Make : Hensel KF 2525G or its equivalent in Syntex
Supply and Fix PVC junction box of size 130x180x77 mm including removing old unsv box all as dirceted Make : Hensel KF 1000G or its equivalent in Syntex
Supply and Fix PVC junction box of size 325x220x150 mm including removing old unsv box all as dirceted Make : Syntex or its equivalent in Hensel
Supply and lay steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 50mm laid in trenches for drawing cables under road/drain crossingsetc all as specified and directed
S&F Battery 100 AH 12 Volt suitbale for TATA BP solar ligts Make: Exide, Amaron, Tata
S&F Battery box suitable for TATA BP solar lights battery as per existing size
S&F Petroleum jelly
S&F 15 watts LED light fiiting, Make:Phillips, Model BRP040 LED 14 CW MR S1 PSU GR or Equivalen in Bajaj, Havells, CG approved by GE.
Servicing and providing minor parts required for functiong of the the inverter MV3 MV6 suitable for TATA BP solar lights
Supply and fix iron rope 6 mm dia 7/19 construction size and length inclding old unserviceable rope complete all as specified and directed by Engr-in-charge.
Dismantling of high mast rope motor from pully and replace old and burnt copper winding and replace on the same position including testing complete all as specified and directed by Engr-in-charge.
Disconnecting and dismantling, taking down of high mast lantern carriage and lowering at ground level and re-fix it in same position after repair and replacement of old unserviceable connectors, nuts and bolts etc, including all allied fittings and fixtures complete all as directed.
Supply only the following items to incorporate for Highmast light
(a)MNX 18 Contactor with MNX A2 auxillary contactor including suitable wiring for Clock wise and anti clock wise motor operation with push button
(b) MCB TPN 63 Amps 4 pole
Servicing of High Mast Gear system for Tool motor, double drum winch with toping up gear oil, pulley assembly, replacement of oil seal, link chain complete all as directed.
Supply and fix 5 core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, incuding removing old wires all as directed
Painting of Highmast ring with choke box and other pipings with two coat of enamel paint
S&F LED 200 W Flood light luminaire with secondary optics made in pressure die-cast housing and heat sink in aluminium extrusion with IP 66. Make : Philips Model : BVP483 LED235 CW NB PSU GR or its equivalent in bajaj / havells/ CG
S&F Integral LED Aviation light comprising of aluminium housing with polycarbonate enclosure fixed in OHT or high raise or jetty building or mast light with all accessories including removing old one all as directed Make: Bajaj Cat No:110731 or equivalent
M&L Preparation of old surface of RCC electric pole 7.5 m long above ground level applying two coats of cement based paint on pole and painting two coats with aluminium paint on cross arms, clamps all as directed
M&L Painting of the solar light poles, bracket panel frame and battery box with one coat of synthetic enamel alumium paint matching with the existing colour
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .