Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹89.3 LAccepted-AOC 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹91.7 L+₹2.0 L (2.26%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹91.9 L+₹2.3 L (2.54%)Rejected-Finance MCB Z 2 13519 ST NO 4 GREEN AVENUE BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹1.0 Cr+₹12.1 L (13.5%)Rejected-Finance | 4 | Rejected-Finance Not Lowest | |
| 5 | 5₹1.0 Cr+₹12.2 L (13.7%)Rejected-Finance PLOT NO D 25 INDUSTRIAL GROWTH CENTRE MANSA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 5 | Rejected-Finance Not Lowest |
Tender Value
₹93 L
EMD Value
₹1.6 L
Closing Date
29 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
PROVN OF 01 X GUARD ROOM FOR 08 MEN ALONG THE PERIMETER AT SECTOR IV AND SPL REPAIR TO STORE HOUSE NO. ESH NO 31 , 56 INCLUDING TRAVERSE UNDER GE (SOUTH) BATHINDA AT BATHINDA MIL STN
2022_MES_498782_1
CWE BTD 8246/E8
Open Tender
Civil Works
Lump-sum
Bathinda
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE (South) Bathinda
₹1.6 L
Yes
10 Feb 2022
1 Jan 2022
31 Jan 2022
1 Jan 2022
29 Jan 2022
17 Jan 2022
1 Jan 2022 - 17 Jan 2022
60 days
Amount
SCHEDULE 'A' PART-I (BUILDING AND STRUCTURE WORKS)
Lump sum price worked out by the Contractor for “Building / Structure Work” as listed in Schedule ‘A’ Part - I Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the Contractor for “Internal Water Supply Works” as listed in Schedule ‘A’ Part -II Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-III (SECTION-'A') (INTERNAL ELECTRIC SUPPLY)
Lump sum price worked out by the Contractor for “Internal ElectricSupply Works” as listed in Schedule ‘A’ Part -III (Section-'A') Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-III (SECTION-'B') (INTERNAL ELECTRIC SUPPLY)
S & F 18/20 watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS 16106/IS 16107, minimum 6000K batten decorative type 4 feet long polycarbonate body, white, in built LED driver, power factor>0.95 , Make – all as per Crompton Cat Part No. DMLN1LT8-16 (for batten) and Cat part No. LT8-20-865-2 (for tube light) OR Equivalent model of any make given in Appdx 'B' including 18/20 watt tube rod or equivalent model of any make given in Appx 'B' connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size all as specifies and as directed.
S & F energy efficient LED street light fitting of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP-66 degree of protection, PF > 0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 25 watt LED lamp with GI brackrt - 01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete all as specified.
S & F heavy duty Exhaust fan 300mm sweep . including electrical connection by providing twin core round copper conductor of suitable size complete all as specified. Make – Havells / Crompton / Bajaj
S & F MCB SP, 6 to 32 Amps, 10 KA, "C' series complete all as specified.
S & F MCB SPN, 20 Amps, 10 KA, "C' series complete all as specified.
S & F only LED Bulb 5 Watt , 6500K , 22 base not less than 100 lumen/watt complete all as specified. Make – Havells / Crompton / Bajaj
SUB TOTAL
SCHEDULE 'A' PART-IV (SECTION-'A')(SEWAGE DISPOSAL)
Lump sum price worked out by the Contractor for “Sewage Disposal Works” as listed in Schedule ‘A’ Part -V Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-IV (SECTION-'B') (SEWAGE DISPOSAL)
M&L for 10 user 2000 ltrs capacity FRP moulded Anaerobic Septic Tank for an anaerobic design in which bacteria treats waste under most favourable conditions, process effectively prevents rapid accumulation of sludge and suspended solids from passing through the system untreated with innovative engineering design of the inlet- outlet short circuit of wastewater which is prevented to ensure longg and enough retention time for effective treatment, thus the effluent dose not contain any solid or scum that could clog up the pipe line.The septic tank is buried underground, solid and liquid waste flow into it. Heavy solid waste settle to the bottom of the septic tank (known as sludge). The liquid wastes are also held in the septic tank while bacteria break down solids into liquids in an anaerobic environment, process is know as primary treatment some bacteria and viruses are adsorbed onto solid particles and held in the sludge or scum layers, allowing for limited removal of disease causing organisms at the stage. All that has to be done for fitting the tank is to fill the tank with water, connect the drain line to the inlet and outlet to the soak pit. Cover the manholes with the lids provided and tank is ready to use incl PCC 1:4:8 below foundation and vent shaft connection, including excavation, returning and filling, removal of excess soil, connection to existing sewage line incld site clearance etc. Make:-Sintex or equivalent / approved by GE. Complete all as specified and directed by Eng-In-Charge.
M & L for Soakage well of size 1.8 Mtr dia x 3.0 mtr effective depth including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM , RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/ DWC complete filled with brick bats complete all as per drawing and as specified.
SUB TOTAL
SCHEDULE 'A' PART- V (ROAD AND PATH)
Lump sum price worked out by the Contractor for “Road and path” as listed in Schedule ‘A’ Part -VI Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART- VI (SPL REPAIR TO STORE HOUSE NO 31 & 56 INCLUDING TRAVERSE OF FAD
Dismantling of structural steel work including doors, gates but excluding framed truss etc.
S & F steel rolling shutters, without ball bearings, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete, gear operated type with bevel gear box and crank handle with thickness of laths 1.25mm.
M & L for painting to new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of flame proof paint over a coat of red oxide primer including preparation of surfaces complete all as specified.
Taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish from the premises to a distance not exc 250 mtr away from site complete all as directed by Engr-in-Charge.
M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of internal wall surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified.
M & L for rendering 15 mm thick in cement mortar (1:4) on external wall surfaces of brick work or concrete surfaces finished even and fair without using extra cement mixed with liquid water proofing material 200 ml per bag of cement complete all as specified. (NOTE – WP material shall be measured and paid for separately.)
Supply only liquid water proofing material, ISI marked.
M&L for rendering 10 mm thick in cement mortar in (1:3) fair faces on ceiling finishing the surfaces even and smooth complete all as specified.
M & L for three coats of white washing on newly plastered wall surface including preparation of surface complete all as specified.
M&L for preparation of old plastered or previously treated surface and applying two coats of white wash on walls.
M & L for preparation of newly plastered surfaces of external walls and applying the following:- (i) Two coats of 100% acrylic exterior emulsion paint by using airless spray/ roller over and including a coat of external acylic primer. Make:- Apex Brand of Asian Paints/Excel Brand of Nerolac Paints/Berger Weather Coat Note :- Contractor may use manual tools for surface preparation with prior approval of Engr- in- charge in writing in case use of mechanical equipments are not possible.
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces and M & L for preparation of old plastered external surfaces of walls and applying the following:- (i) Two coats of weather proof (antifungal) exterior emulsion paint by using airless spray/ roller over and including a coat of exterior emulsion primer. Make:- Apex Brand of Asian Paints/Excel Brand of Nerolac Paints/Berger Weather Coat Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
M & L for preparing newly plastered surfaces of ceiling and applying three coats of white wash all as specified.
All as per ser item No. 36 above but two coats of white wash on old surface compete all as specified.
Demolition of PCC in ground floors and pavings not exc 15cm thickness (below or above ground level) and removing rubbish to a distance not exc 250 mtr away from site complete as directed by Engr-in-Charge.
M&L for 100 mm thick PCC (1:1.5:3) type A-2 using 40 mm graded stone aggregate as in floor finishing the surface even and smooth without using extra cement including making even and fair of base surface by watering & ramming as required and directed.
Forming 12mm thick expansion joints in 100mm thick concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' complete all as directed.
Racking out joints / pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs, etc built in cement mortar.
M & L for keyed pointing to brick walls in cement mortar (1:3) complet all as specified.
S&F PVC (SWR) 110mm bore pipes single socketed, ISI marked, pressure rating 6 Kg per sqm in any length with rubber ring joints, fixed to walls with MS clamp including taking down old eaves gutters and rain water pipes (any size or pattern ), including all fittings.
S&F PVC (SWR) 110mm bore bends of any radius fixed to PVC pipe complete.
Dismantling of brick work or boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, and removing rubbish from the premises to a distance not exc 250 mtr away complete all as specified.
M & L for Brick work using old size bricks, straight or curved on plan exceeding 6 meter mean radius built in cement mortar (1:4), complete all as specified..
All as per ser item No. 46 above but except bricks compete all as specified. Note:- Old serviceable bricks obtained from dismantling shall be re-used.
Excavation in trenches not exc 1.5 meter wide and not exc 1.5 meter depth for foundation etc or for shafts , wells, cesspits, manholes , septic tank, for laying of cables etc not exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specified and as directed .
Returning filling in, including spreading , leveling, watering and well ramming in layers each not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus excavated soil to a distance exc 250 mtr but not exceeding 500 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
M & L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation , sub base, filling and mass concrete complete all as specified..
M & L for PCC (1:2:4) type B0 using 12.5mm graded stone aggregate in coping, stitching, blocks, roof kerbs etc complete all as specified.
S&F wire netting of galvanised steel wire 0.91 mm dia, size of mesh 25mm x 25mm, fixed with tinned tacks of wire staples complete all as specified.
M & L for TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) for flat rough surfaces of concrete.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges with rough finished surface of concrete.
Providing and erecting adjustable ( jack type ) steel props (up to full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till required i.e chipping of unsound concrete/ demolition & complete treatment complete and as directed by Engr-in-Charge.
Chipping of unsound weak and cracked concrete/ cover of reinforcement over RCC member (ceiling beam, columns etc) or as per site requirement upto minimum half depth of bars by chiseling and disposal of rubbish form site to a distance not exc 250 mtr incl all required scaffolding/ ladders complete all as specified.
Cleaning of existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, diet etc, complete and proving applying two coats (0.4 Kg/Sqm) of alkline rust converting primer Sika Rust off-100 or equivalent in Fosrock/ Pidilite on the existing rebar and allowing it to react with rust for 6 hrs form corrosion resistant, insoluable and adherant protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls with time interval of 1 hour between the coats incl all required scaffolding / ladders complete all as specified as per manufacturer's instruction and as directed. Note:- Girth of RCC member shall be measured.
Providing and application of zinc rich epoxy anti-corrosive protective coating of sika friazinc (R) or equivalent for rebar corrosion protection system in 2 coats (of 0.4 kg/Sqm approx) complete all as specified and directed. The product should confirm carbonation resistance of 2mm and bond strength > 1N/Sqmm according to ASTM C-882-78 incl all required scaffolding/ ladders complete all as specified as per manufacturer's instruction and as directed..
Providing, mixing & applying two components Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer specification with Sikadur(R)-32 LP or equivalent in consumption of 0.4Kg /m2. The product should comply with ASTM C-881 Type II Grade 2 Class B+C and bond strength should be 10 MPa, including all required scaffolding/ ladders complete all as specified as per manufacturer's instruction and as directed..
Rebuilding the section of damaged RCC elements to its original size or as per consultants recommendations in thickness upto 20 mm in layer of 10 mm each by providing and applying with pre-batched, one component fiber reinforced cementations patch repair mortar Sika(R) Mono Top (R) -122 F or equivalent having compressive strength >= 50 N/Sqmm (28 days) according to ASTM C 109 : Flexural strength >= 50 N /Sqmm (7 days) according to ASTM C 293-79, including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed.
Providing & fixing 10mm dia & over rebar of required length & diameter with Sika Anchor Fix(R)-3+/Mungo/Fischer FISV 390/ Hilti RE-500 Epoxy resin where ever required in RCC members including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled with epoxy to ensure the nond as per manufacture recommendation complete as per site requirement including all required scaffolding / ladders complete all as specified as per manufacturer's instructions and directed.
Rebuilding the section of damaged RCC elements to its original size in thickness of up to 100 mm by providing and casting with ready to use non shrink. Cementations free flow micro-concrete Sika Rep Microcrete-4 or equivalent having compressive strength > 60 N / sqmm (28 days) according to ASTM C 1107-99 including providing and fixing of watertight foam faced finish shuttering of minimum 18 mm thickness and supporting formwork, all lead fit, mixing, placing, de-shuttering, leveling the surface by grinding off cementations slurry or cementations joints differences if any for satisfaction of Engr-in-Charge and curing thereof including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed.
Making 'V' groove of 5 mm wide and 5mm deep over crack line by electrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower and sealing of exposed 'V' groove of 5mm deep and 5mm wide with solvent free, moisture tolerant thyrotrophic, two part structural adhesive and repair mortar, based on epoxy resins and special fillers, designed for use at temperatures between +10ºC and +40ºC, Sikadur-31N or equivalent having conforms to ASTM C-881-78, Type I, Gde 3, Class B+C compressive strength > 60 N / sqmm (14 days) according to ASTM C 881: bond strength > 10 N / mm ² (7 days) according to ASTM C-882 including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed.
Drilling holes of 12mm dia upto 100 mm deep holes in structural members at the interval of 300mm in staggered manner or along the crack line in reinforced concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatitable with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix it inside the hole by applying thixotropic epoxy putty Sikagard-694 F(I) or equivalent to ensure complete sealing and allow to cure the system for minimum of 8 hrs before Grouting including nozzle projections, excess putty, if any, over concrete element remove by gridding , leveling and finishing the external surface after completion of the work etc including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed
Grouting injecting two part, low viscosity, moisture insensitive injection- liquid, based on high strength epoxy resin Sikadur (R) -52 LP(IN) or equivalent by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having mixed density 1.1 kg/Ltr (at + 27ºC) : Viscosity -250 m Pass at + 30ºC and should comply according to ASTM C 881 Type II and IV , Grade-I , class E+F and should have following properties. Compressive strength >= 70 N/Sqmm (7 days) according to ASTM C 579 : Tensile strength -5N / Sqmm after 7 days at +30ºC cure) according to ASTM D 638 : Tensile modul- 2000N / Sqmm after 7 days at +30ºC cure) according to ASTM D 638, Bond strength -10.8N /Sqmm (failure in concrete ) after 14 days at +30ºC cure) according to ASTM D 638 : Bond strength : Flexural strength -50 N / Sqmm according to ISO 178. Seal with nozzle with Sikadur 31 or equivalent thixotropic epoxy putty after the refusal of grout material from the nozzle. Note :- Leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed
M & L for removal of old roof treatment from RCC roof top by chieseling, cutting, grinding etc including cleaning of all loose dirt/ roots etc complete all as specified and directed.
Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, complete all as specified and as directed by Engr-in-Charge.
Rendering 20 mm thick on fair faces of brick work or concrete surfaces of roof, in cement mortar 1:4 rendering is to be finished even and smooth ( without using extra lime or cement), complete all as specified. Note:- WPC will be measured and paid for separately under respective item of BOQ.
M&L for water proofing treatment over RCC slab by applying oil bound bituminous primer @ 0.25 kg/Sqm and providing and laying 3mm thick APP modified water proofing memberane weighing not less than 3.50 kg/sqm, reinforced with non woven polyester reinforcement matt weighing not less than 160 gm/Sqm polyester core, having soften point not less than 150°C, longitudinal tensile strength not less than 650 N/ 5 cm, tearing strength of 180 N, torch application, side overlap 75 mm and end overlap 100 mm and tucked into the chases applying a coat of solar reflective aluminium paint @ 0.11 Kg/ Sqm on membrance surface all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, regulators, light fittings etc and removing the retrieved materials from site including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed.
M & L for flameproof point wiring for one light point controlled by one way flameproof switch with 1.5 sqmm (nominal area) PVC insulated unsheathed multi stand copper conductor cable FRLS in and including ERW stove enameled surface rigid conduit 20mm dia heavy duty ISI marked accessories such as flame proof joint/ junciton boxes, bends, corners, tees, unions, reducers, nipples etc all in LM6 , screws , clips, clamps etc and including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLS connected to common earth dolly complete and then making good the surface complete all as spcified. Note:- Switch with termination box shall be measured and paid for separately under appropriate items of Sch 'A'.
All as per ser item No. 73 above but for each additonal light point on the same switch circuit.
S & F switch flame proof rotary type with termination box in LM6 , 16 Amp , single pole 250 Volt complete all as specified.
S & F in repair flame proof distribution board SPN 8 way 230 volt made of die coast aluminium alloy (LM-6) gas groups IIA, iiB, IIC certified by CMRI conforming to IS-2148/2004 & IS-13346/2004 with anticorrosive epoxy powder coated paint with on /off rotary switches for MCBs complete including incoming 01 x MCB 20 A SPN and outgoing 06 x MCB 6A SP complete all as specified.
S & F LED 40 watt flameproof bulk head/ well glass luminair recommended for Gas / vapor group of IIA, IIB and Zone 1 & 2 made of die cast aluminium housing with heat resistant toughened glass, IP 65 protection, CMRI approved complete all as specified
S & F LED 15 watt flameproof bulk head/ well glass luminair recommended for Gas / vapor group of IIA, IIB and Zone 1 & 2 made of die cast aluminium housing with heat resistant toughened glass, IP 65 protection, CMRI approved complete all as specified
SUB TOTAL
V K CONTRACTOR
N.G BUILDERS
M/s Kataria Construction Company
M/S VERMA BUILDERS & DEVELOPERS
SARASWATI CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .