Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.9 L+₹91,999 (2.97%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹33.3 L+₹2.3 L (7.28%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹33.8 L+₹2.8 L (9.04%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹34.0 L+₹3.0 L (9.60%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹46.8 L
EMD Value
₹93,500
Closing Date
29 Dec 2021, 6:00 pmClosed
GE I KANPUR
GE I KANPUR Cariappa Road Kanpur 208004
SPECIAL REPAIR REPLACEMENT OF LT OVERHEAD LINES INTO UG CABLE AT VARIOUS PLACES AT KANPUR CANTT
2021_MES_492871_2
GE(I)/KAN/T-60 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kanpur Cantt
Class D category b i
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹93,500
Yes
15 Jan 2022
8 Dec 2021
5 Jan 2022
8 Dec 2021
29 Dec 2021
23 Dec 2021
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables.
Returning filling, in including spreading, levelling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to underground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
Supplying and laying sub class b bricks old size, size 230mm x 115mm 75mm complete all as specified and directed.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection pipe upto 50 mm bore complete all as specified and as directed by Engineer in Charge. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
M&L for cutting of road depth upto 1.5 mtr below the normal ground level of suitable size to lay cable upto 185 Sqmm across the road in horizontal position incl making good all disturbed surfaces of road to match with existing surfaces by premix road material/PCC all as spcfd and directed.
Material and labour for GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as per srl item No 8 but 50mm bore
All as per srl item No 8 but 40mm bore
Supply laying , jointing, testing and commissioning of XLPE insulated, PVC sheathed, strip armoured heavy duty electric cable 240 Sqmm 3.5 Core with aluminium conductor (stranded) working voltage upto 1100 volt confirming to IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of aluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed of the following sizes: Note : 1.Cable laying and jointing are required to be carried out in short / long stretches as per site requirement.2.Necessary excavation and earth work , sand cusioning, cable cover will be measured seprately.
All as per srl item No 11 but 185 Sqmm 3.5 Core
All as per srl item No 11 but 120 Sqmm 3.5 Core
All as per srl item No 11 but 70 Sqmm 3.5 Core
All as per srl item No 11 but 50 Sqmm 3.5 Core
All as per srl item No 11 but 35 Sqmm 4 Core
All as per srl item No 11 but 25 Sqmm 4 Core
All as per srl item No 11 but 16 Sqmm 4 Core
All as per srl item No 11 but 10 Sqmm 2 Core
All as per srl item No 11 but 6 Sqmm 2 Core
M&L for Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 25 to 35 Sqmm 3.5/4 core.
All as per item No 21 but for 6 to 16 Sqmm size.
All as per item No 21 but for 50 to 95 Sqmm size.
All as per item No 21 but for 120 to 240 Sqmm size.
Supply and installation, connecting eclectically & commissioning of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated aluminium bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35 KA of make : Legrand/Havells/L&T complete all as required at site.
S&F of bus bar chamber with MCB SP 6 Amps-01 No outdoor type of size 400 x 380 x 190 mm made out of MS sheet 3mm thick with alum bus bar three phase & neutral each 320 x 20 x 6 mm of size fixed on insulators and fixing on steel pole with proper clamps, nuts , bolts & washers of required size and making connection of LT cables with thimbles, glands and making good the disturbed surfaces incl water proof PVC sticker like danger mark all as required at site.
Supply & fix of cable PVC insulated flexible copper conductor cable of size 1.5 Sqmm 3 core cut to pieces all as required for connetion with proper thimbles, drawn in existing/new GI pipe fixed to wall or pole all as directed by Engr-in-charge.Make of Cable : Havells/L&T/Grandlay/Polycab/Plaza
Dismantling from insulators and taking down ACSR conductor any size from HT/LT over head lines and removing from site
Dismantling insulator any type and any size from HT/LT over head lines and fixing other side or removing from site
Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside for reuse on the same or new location or removing from site complete all as required and as directed by Engr-in-charge.
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate removing from site complete all as required and as directed by Engr-in-charge.
Dismantling steel poles any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside and removing from site complete all as required and as directed by Engr-in-charge .
Supplying, installing, testing and commissioning outdoor cubical feeder pillar box suitable for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS:8623 / 93 comprising of the following:- OUTER SHELL- The outer shell shall be made out of 3.15 mm thick CRCA sheet & MS angle section 50x50x6 mm frame with front & back open able, double door system lockable / openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. 'U' type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The outer shell shall be powder coated with pure polyester Siemens grey structural RAL 7032 shade. The dimension of the outer shell should be adequate to accommodate inner shell described below giving 50 mm space all around & shall be fabricated in such a way that the whole inner shell alongwith its control gears & accessories could be taken outside without disturbing outer shell. The outer shell shall be mounted on a powder coated metal stand. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The degree of ingress protection of outer shell shall be IP-54.
Iitem no 33 contd.... INNER SHELL: Inner shell made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, front openable single door system lockable I openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers & air vent gasket for natural flow of air. 'U' type gasket shall be used to make the inner shell completely vermin proof & to accommodate incomer / outgoing MCCBs and 400 Amp TPN copper bus bar and extension links of rating not less than the 1.5 times the rated capacity of the respective MCCB. The TPN bus bar and extension links shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators . All control wires shall be with 2.5 sqmm multi strand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. The cubical shall have a bottom channel of size 75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at the bottom. The inner shell shall be of powder coated Siemens grey structural RAL7032 shade. Indicating lamps LED type, 230 volt. AC at the incomer of the unit to show three phase availability at the outgoing of incomer.: INCOMING:- (i) 4 pole MCCB of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with adjustable thermal megnatic release type - 01 No. (ii) Digital multifunctinal meter V, A,,- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 63 Amp, breaking capacity 25 KA with fixed thermal magnetic release, - 07 Nos
Supplying, installing, testing and commissioning outdoor cubical feeder pillar box suitable for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS:8623 / 93 comprising of the following:- OUTER SHELL- The outer shell shall be made out of 3.15 mm thick CRCA sheet & MS angle section 50x50x6 mm frame with front & back open able, double door system lockable / openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. 'U' type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The outer shell shall be powder coated with pure polyester Siemens grey structural RAL 7032 shade. The dimension of the outer shell should be adequate to accommodate inner shell described below giving 50 mm space all around & shall be fabricated in such a way that the whole inner shell alongwith its control gears & accessories could be taken outside without disturbing outer shell. The outer shell shall be mounted on a powder coated metal stand. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The degree of ingress protection of outer shell shall be IP-54.
Item no 34 Contd... INNER SHELL: Inner shell made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, front openable single door system lockable I openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers & air vent gasket for natural flow of air. 'U' type gasket shall be used to make the inner shell completely vermin proof & to accommodate incomer / outgoing MCCBs and 400 Amp TPN copper bus bar and extension links of rating not less than the 1.5 times the rated capacity of the respective MCCB. The TPN bus bar and extension links shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators . All control wires shall be with 2.5 sqmm multi strand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. The cubical shall have a bottom channel of size 75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at the bottom. The inner shell shall be of powder coated Siemens grey structural RAL7032 shade. Indicating lamps LED type, 230 volt. AC at the incomer of the unit to show three phase availability at the outgoing of incomer.: INCOMING:- (i) 4 pole MCCB of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with adjustable thermal megnatic release type - 01 No. (ii) Digital multifunctinal meter V, A, ,- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with fixed thermal magnetic release, - 01 Nos (b) 4 pole MCCB of capacity 63 A, breaking capacity 25 KA with therixed thermal magnetic release - 03 Nos
M&L for in renewal earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI earth strip 32 mm x 6 mm thick by means of bolts nuts,check nuts and washers at complete etc all as shown in electrical plate No-3 of SSR part-1 (2009) including necessary earth work, GI pipe 40mm dia light grade for protection of galvanised iron earthing stripe, etc. with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply compete all as specified and testing of earth resistance as required.
A.B.Enterprises
PAWAN COOL CORPORATION
M/S DARSHAN ENGINEERING WORKS
DEO Traders
Bharat Sales Corporation
VEE KAY ENTERPRISES
Lalta Prasad vijay kumar Forwarding Agency
Ashirwad Contractor and Supplier
U K Enterprises
M/S B.S ENTERPRISES
M/S VIKASH TRADERS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .