Tender Value
₹3.8 Cr
EMD Value
₹7.6 L
Closing Date
14 Aug 2026, 3:00 pm
Provision of fire suppression system at MB station and replacement of non RDSO AFDAS with RDSO approved over MB Division.
SNT-AFDAS-FIRE-2025-26
SNT-AFDAS-FIRE-2025-26
Open
Works - General
12 Months
Unknown (Unspecified Location)
₹0
₹7.6 L
23 Jul 2026
23 Jul 2026
31 Jul 2026
01-Provision of Automatic fire detection and Alarm system at Telecom
Supply, Installation, Testing &Commissioning of Microprocessor based Networkable analog addressable and modular type of fire Alarm Control Panel with display with 2 loop expandable upto four loop ,power supply and battery back up as per RDSO specification no. RDSO/SPN/217/2025 01 Ver 3.1 or latest. Including GSM module-01 No. for sending SMS to configured mobile number and relay module -02 Nos. for connecting to Datalogger for remote monitoring. The panel should support sufficient devices of both detectors and modules in a single line circuit . Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing & Commissioning of Addressable heat and smoke Multi 02 sensor. As per RDSO specification No. RDSO/SPN/217/2025 Ver 3.1 or latest Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing & Commissioning of Analogue Addressable & resettable 03 Manual Call Point with inbuilt short circuit fault isolator (as per RDSO/SPN/217/2025 Ver 3.1 or latest. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre- commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing & Commissioning of Hooter cum Strobe including its control module As per RDSO specification No RDSO/SPN/217/2025 Ver 3.1 or latest. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre- commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing & Commissioning of Linear Heat Sensing (LHS) cable as 05 per RDSO Specification No. RDSO/SPN/217/2025 Ver 3.1 or latest. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing & Commissioning of LHS interface module as per RDSO 06 Specification No. RDSO/SPN/217/2025 Ver 3.1 or latest. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing & Commissioning of Aspiration systems with single pipe 07 slot along with required module and power supply interfacing module etc as per RDSO specification no RDSO/SPN/217/2025 Ver 3.1 or latest. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing & Commissioning CPVC Pipe and all other associated 08 fittings as per RDSO/SPN/217/2025 Ver 3.1 or latest. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of Fire Survival cable 2C X1.5 Sqmm (Meters) unarmoured, (As per RDSO 09 Specification No. RDSO/SPN/217/2025 Ver 3.1 or latest. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of PVC Conduit Pipe of 25 mm dia ISI marked heavy (HMS)series as per IS: 9537part-III - 1983 standards or latest. Inspection Authority: RITES Technical Specification: As per technical specification provided in Part III of Tender Document
Laying & Fixing of conduit 25mm (conduit Pipe must be fixed with clamp at the interval of 300mm)/HDPE/GI/RCC Pipe Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing and commissioning 70bar/180 Litres capacity Seamless cylinder CCOE approved, complete with valve assembly and pressure gauge with a safety burst disc 12 and a safety cap and and shall comply to RDSO/SPN/218/2016 VERSION 1.0-d2. or latest. Gauge with safety burst disc and a safety cap. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of FK-5-1-12 Fire Protection fluid compound of carbon, flourine and oxygen 13 (CF3CF2C(O)CF(CF3)2). Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing and commissioning Electric Control Head operated 14 electrically from the Detection & control system or locally with a manual lever on the control head. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre- commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing and commissioning Pressure operated Control Head 15 which allows for pressure actuation slave cylinders and is mounted directly on top of the slave cylinders valve. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply, Installation, Testing and commissioning of Discharge Nozzles are designed to 16 provide the proper flow rate and distribution of FK-5-1-12 to total flood a hazard area: 180deg / 360deg. Inspection Authority: Supply: RDSO, Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of Master Cylinder Adapter Kit used to actuate the slave cylinder. Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and Installation of Discharge Hose 1-1/2" (use with 34, 80, 120 & 140 Ltr. Cylinders. Inspection Authority: Supply: RDSO, Installation : Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and Installation of 1-1/2" manifold check valve installed at the discharge 19 manifold to allow removal of any FK-5-1-12 cylinder from the manifold while still retaining a closed system. Inspection Authority: Supply: RDSO, Installation : Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and Installation of Flexible Actuation Hose(Pilot pressure is directed to a 20 pressure operated control head on each cylinder valve using 1/4inch Actuation Hose. Inspection Authority: Supply: RDSO, Installation : Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and Installation of Manifold Supervisory Switch for indication of discharge of system. Inspection Authority: Supply: RDSO, Installation : Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and Installation of Cylinder Strap for 120 & 140 ltr Cylinder. Inspection Authority: Supply: RDSO, Installation : Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and Installation of Brass Male Elbow. Inspection Authority: Supply: RDSO, Installation : Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and Installation of M S Seamless pipes as per ASTM A 106 Gr.B.Sch.40 for the system. Inspection Authority: Supply: RDSO, Installation : Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and Installation of Cylinder rack support, Pipe support, Manifold and all other 25 accessories required to complete the system. Inspection Authority: Supply: RDSO, Installation : Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of Local manual Accuator. Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of WARNING PLATE-System warning Sign. Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of WARNING PLATE- Agent Discharge Warning sign. Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of Gas release Panel. Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of Manual release Switch. Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of Manual abort switch UL listed. Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document
Installation, Testing & commissioning of fire suppression system and accessories. In cabinet Fire suppression Inspection Authority: Installation & Commissioning: Site Engineer along with OEM Pre-commissioning checklist Technical Specification: As per technical specification provided in Part III of Tender Document
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
fireTDfinal_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].