Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.5 LAccepted-AOC | 1 | Accepted-AOC Rates are reasonable being single Bidder |
Tender Value
₹15.2 L
EMD Value
₹30,446
Closing Date
27 Sept 2024, 3:00 pmClosed
Director NCL Pune
CSIR National Chemical laboratory, DR Homi Bhabha Road, Pashan Pune 411008
Variuos Electrical works related to Platinum Jubilee celebration at CSIR NCL
2024_CSIR_207662_1
Elect/PJ Cel/2024-25/01
Open Tender
Electrical Works
Works
90 days
CSIR National Chemical Laboratory Pune
As per NIT
3 documents required · 3 mandatory
₹500
Director NCL Pune
₹30,446
5 Nov 2024
9 Sept 2024
30 Sept 2024
9 Sept 2024
27 Sept 2024
9 Sept 2024
9 Sept 2024 - 20 Sept 2024
Amount
Dismantling the existing light point carefully inPVC casing capping/PVC conduit/conceales or surface type.The dismantled material should be returned to the NCL stores at no extra cost.
Dismantling the existing light fitting carefully from Ceiling/False ceiling without damaging the fittings.The dismantled material should be returned to the NCL stores at no extra cost.
Supplying, fixing & connecting on ceiling prewired LED light fitting Surface 4' long Philips,Samrt Bright XTRA with 4000Ljmens uptput cat no.BN100C LED40S-6500 PSU L120 GR S4 or equvalent of Havells or Wipro make complete with driver and fixing arrnagement. The fitting should installed on the ceiling by.The LED Light fiting should have minumum 3 years replacement warranty.(For corridors in buildings )
Supplying, fixing & connecting on ceiling/wall with prewired LED tube light fitting with metal body Philips make cat No.BN170C LED20S-6500 PSU L120 or equvalent of / Havells/Wipro mak, 4' long complete with accessories.The LED Light fiting should have minumum 3 years replacement warranty (Staircases)
Supplying, fixing & connecting on metal bracket LED Flood Light fitting with metal body Philips make cat Uniflood BVP120 LED093 CW FLNB FG A1 PSU GR 100Watts or equivalent of Havells or Wipro make, 100W or higher wattage IP65 complete with accessories. The LED Light fiting should have minumum 3 years replacement warranty (For main building & Gate flood light)
Supplying, fixing & connecting on metal bracket LED Flood Light fitting with metal body , Havells make JETA RESOLUTE cat No.JETARESOLUTEFLS250WLED75760DTOTG or Philips make Field Star cat BVP283 LED240 CW FG SY5NB 200W SPD V1 or Equivalent of Havells or Wipro make, 50W, IP65 complete with accessories.The LED Light fiting should have minumum 3 years replacement warranty (For main building & Gate flood light)
Supplying, fixing & connecting LED Spike Light fitting with metal body Havells Cat No. IRVINESPS5WLED830PSYMTG or Philips make cat No.BGP150 LED580/NW 8W 45D GM complete with accessories.The LED Light fiting should have minumum 3 years replacement warranty (For Gearden lights at Main gate)
Wiring for surface/Concealed Light/Fan/Exhaust fan point with 2 x 1.5 Sq.mm PVC insulated FRLS wires copper conductor Polycab/Finolex/RPG make 1100Volts grade in PVC conduit pipe Asian/Diamond/ PVC Casing capping Modi/ASIAN/DIAMOND make & Modular switches MK Blenz PLUS/ Legrand Myrius Nex Gen make with MS/PVC surface box & modular plate complete with connection & holder/ceiling rose. Also to run an earth wire of 1sqmm all along the length of the point. (For Gaps in corridor of existing lights in Main bldg)
Wiring for circuit wiring with 2x2.5sqmm + 1 x 2.5 sqmm as earth PVC insu.copper cond. FRLS wires Polycab/Finolex/RPG make, 1100V grade in PVC conduit pipe Asina/Diamond make including accessories & connections at both ends. (circuit mains for lighting)
Wiring for circuit wiring with 4x2.5sqmm + 2 x 2.5sqmm as earth cond, PVC insu.copper cond. FRLS wires Polycab/Finolex/RPG make, 1100V grade in PVC conduit pipe Asina/Diamond make including accessories & connections at both ends. (circuit mains for lighting)
Painting of Transformer substation fencing including all supports, doors iron work on both sides by scrapping existing paint, with one coat of red oxide and two coats of Aluminium paint complete. (At Substation I & II)
Painting of feeder pillars/Panel board on both sides by scrapping existing paint, with one coat of red oxide and two coats of approved coloured enamel paint by spray paint complete. ( Main Panels at Main Building)
Painting of street light pipe pole upto 6 meters along with street lights, pole brackets/clamps etc by scrapping the existing paint completely anf applying one coat of red oxide and two coats of Aluminium paint. ( Street Light Poles in Laboratory campus)
Painting of street light pipe pole above 6 meters along with street lights, pole brackets/clamps etc by scrapping the existing paint completely anf applying one coat of red oxide and two coats of Aluminium paint. ( Poles at Main Garden from main gate to Main building)
Supplying and erecting, Testing & commissiosning 6mtr high Hot Deep Galvanised Octagonal pole 6 mtr long with Bottom 130mmA/F and top of 70mm A/F, 3mm thickness with base plate 200x200x12mm of approved shape on provided foundation with single arm cap type bracket arm of approved design suitable to accomodate 45 Watts/70Watts LED street light fitting. The pole should be provided with MS base plate of suitable size with tamplate & GI nut bolts.Test certificate from manufacturer should be produced.The pole should be provided with in built junction box with SPMCB 6A mounted on channel & Bakelite connectors of suitable size for looping.The pole should have bolting arrangement for terminating GI earthing wire/Strip. rate is inclusive of the single arm bracket made of GI of approved shape & design. (Rate is without pit.) (For Gate Lights & Parkng Lights)
Providing & casting cement concrete foundation for grouting above pole mentioned in item No.1 in M-20 grade reinforced cement concrete of size up to 600mm x 600mmx1.20 mtr. deep including excavation in all stratas suitable for 5 to 6 Mtr high octagonal /Conical GI pole. Rate should be inclusive of supply of steel, concrete, excavation & fixing provided nut bolts wih the help of template as per design in an approved manner.The foundation should be watered for curing & painted with cement paint as required by site engineer.(For street light poles )
Making trench 90 cm deep & 45cm wide in ground including excavation in ground for laying cables and refilling the same with sand, bricks above the cable & remaining portion duly filled with excavated material after removing stone and other sharp material, etc including site cleaning as required by site Engineer.Rate is inclusive of laying 2x 2.5sqmm. cable in trench or through G.I.pipe laid at road crossing).
Supplying, fixing & laying of 50 mm Dia DWC pipe of Polyethylene (confirming to Is 14930-II) (Similar to TELEREX/ELETREX) with necessary connecting sockets /couplings ,tees of same material at required depth & fixed to the pole with necessary clamp of MS.The pipe should be fixed to the pole & coping in such a way that it should be easy to replace the cable through it.(For swan neck poles)
Supplying & erecting C.I.Cable route marker with inscription engraved as “LT CABLE” on it.The flag should be of 100mm dia 5mm thick & MS angle of 30cm long for grouting.The marker should be grouted in cement concrete with necessary curing thereof with silver painting.
Supplying & laying ,erecting in excavated cable trench PVC armoured cable, 2 core x 2.5 sqmm, Polycab/ Gloster/ Havell's/ Finolex-Make, copper conductor 1.1KV grade at NCL site. Also to supply & lay a contineous eath wire of 2 x 12 swg all along the length of cable. (Before supplying the cable actual measurements at site should be taken in consultation with site Engineer.)
Supplying laying inside the octagonal pole & Connecting PVC insulated Cu cond 3 core flexible cable FRLS Polycab/Finolex/RPG make of size 3 x 2.5sqmm by taking inside the pole & connecting to fitting.
Earthing with G.I. earth plate of size 60cm x 60cm x 6.35mm thick in 2 mtr deep & 1mtr wide pit with ¾” G.I.pipe for watering & ½”G.I.pipe for earth conductor. Refilling the pit with 30 Kg charcoal & 30 Kg salt as per IS. Also constructing a cement concrete chamber with C.I.cover with locking arrangement & funnel for watering. Item should be carried out as per IS drawing.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .