| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹22.4 L+₹1.4 L (6.66%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹23.8 L
EMD Value
₹47,520
Closing Date
5 Oct 2023, 6:00 pmClosed
Headquarters CWE Khadki, Military Engineer Service
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
PROVISION OF 1 X RMU 22 KV 630 AMPS ALONGWITH VCB PANEL 11 KV WITH ALLIED PROTECTION RELAY AT NEW 22 KV / 11 KV SUB STATION FOR MH KIRKEE UNDER GE MH AND RH KHADKI
2023_MES_617568_1
CWE/KEE/TOKEN-15 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
CWE Khadki
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MH AND RH KHADKI
₹47,520
11 Dec 2023
6 Sept 2023
10 Oct 2023
6 Sept 2023
5 Oct 2023
21 Sept 2023
8 Sept 2023 - 10 Sept 2023
Amount
Supply, installation, testing and commisioning of RMU 3 way outdoor type extendable motorised SCADA compitable RMU as per MSEDCL specification of capacity 630A, 22kV, 21kA/3sec, consisting of 2Nos. feeder with Load Break Switch (Incomer) and 1No. feeder with VCB (outgoing). (2LBS + 1VCB+M) - Qty. – 1No. complete with PCC foundation as per OEM drawing, including disconnection of exisitng HT XLPE cable of size 300 sq mm, 22 KV (02 Nos incomer and 01 No outgoing) from 04 pole structure,. shifting up to newly installed RMU, necessary all electrical connection terminatin and earth work complete all as directed. Each Incomer feeder with Switch consists of:
(A) i) Motorised 630A load breaker switch with built-in earth switch with full making capacity. - 01 Nos. ii) Mechanical position indicator. Switch ON/OFF/EARTHED - 1 No. iii) Live Cable Indication - 1 No iv) Cable compartment cover interlocked with earth switch. 1 No. v) Cable termination bushings suitable for 3 no. 1C X 300mm2 XLPE cable. - 03 Nos vi) 22kV Screened touch proof Cable termination kit with boots - 1 Set vii) NO/NC contact for - 1 Set a) Isolator ON/OFF b) Earth Switch ON/OFF c) Fault Indicator Operated viii) Command Output for: - 1 Set a) Isolator Close b) Isolator Open c) FPI reset
B. Each Outgoing VCB feeder consists of: i) Motorised 630A Vacuum Circuit Breaker with manual spring charging arrangement and manual close & open push buttons, ON / OFF indication and series trip coil for self powered relay & shunt trip coil for external tripping - 1 Nos ii) Self powered Numerical O/C & E/F relay with CTs of ratio 400- 200/1A, 2.5VA, 5P10 (Protection core) & 2.5VA, Cl 0.5 (Metering core). - 1 Set iii) Manually operated 630A load breaker switch with built-in earth switch with full making capacity. 1 No iv) Mechanical position indicator. Switch ON/OFF/EARTHED. 1 No. v) Live Cable Indication. 1 No. vi) Cable compartment cover interlocked with earth switch. 1 No. vii) Cable termination bushings suitable for 1no. 3CX300mm2 XLPE cable. - 03 Nos viii) 22kV Screened touch proof Cable termination kit with boots. - 1 Set ix) NO/NC contact for a) Breaker ON/OFF b) Relay operated. - 1 Set
C. Metering Module as Bus PT- 01 Nos Metering Bus i) Set of 03nos. Single Phase Potential Transformers having ratio 22 kV/rt3:110V/ rt3, 50VA, Class 0.5 - 01 Nos ii) Provision for installation of Multifunction Meters for energy reading in breaker functions. - 01 Nos D.Common Items per RMU i) SF6 Gas Pressure indicator with auxiliary contacts. ii) 1No. Handles for RMU iii) 2Nos. Fault Passage Indicator with associated CT’s. iv) Battery & Battery Charger. v) 500VA Auxiliary Transformer vi) water level controller
Supply, installation, testing and commissioning of 3 way outdoor Extensible motorized SCADA compatible VCB panel as per MSEDCL specification consisting with Vaccume Circuit Breakaer 01 Nos (Incomer) and 02Nos. feeder with VCB (outgoing) of capacity 630A, 11kV, 21kA/3sec, consisting of 3 Nos. feeder with VCB. (3VCB+M) - Qty.-1No. complete with PCC foundation as per OEM drawing, including disconnection of exisitng cable of size 240 sq mm, 11 KV (01 Nos incomer and 01 No outgoing) from near by breaker to newly installed VCB Panel, necessary all electrical connection terminatin and earth work complete all as directed.
A. Each Incomer & outgoing VCB feeder consists of:
i) Motorised 630A Vacuum Circuit Breaker with manual spring charging arrangement and manual close & open push buttons, ON / OFF indication and series trip coil for self powered relay & shunt trip coil for external tripping. - 01 No ii) Self powered Numerical O/C & E/F relay with CTs of ratio 400-200/1A, 2.5VA, 5P10 for (Protection core) & 2.5VA, Cl 0.5 (Metering core). - 01 Set iii) Manually operated 630A Disconnector. - 1 No. iv) Mechanical position indicator. Switch ON/OFF/EARTHED. - 1 No. v) Live Cable Indication. - 1 No. vi) Cable compartment cover interlocked with earth switch. - 1 No. vii) Cable termination bushings suitable for 1no. 3CX300mm2 XLPE cable. - 03 Nos viii) Cable termination cover boots (Push on type) - 01 Set ix) NO/NC contact for: a) Breaker ON/OFF b) Relay operated.
B.Metering Module as Bus PT - 01 Nos i) Set of 03 nos. Single Phase Potential Transformers having ratio 11kV/rt3:110V/rt3, 50VA, Class 0.5 - 01 No ii) Provision for installation of Multifunction Meters for energy reading in breaker functions. - 01 No
C.Common Items per RMU i) SF6 Gas Pressure indicator with auxiliary contacts. ii) 1No. Handles for RMU iii) 1No. Fault Passage Indicator with associated CT’s. iv) Battery & Battery Charger. v) 500VA Auxiliary Transformer vi) water level controller Note : (i) PCC for foundation will be measured and paid sepretaly under relavant items of schedule (ii) Earthing for RMU 22 KV & VCB 11 KV panel are exist at site
M & L PCC type B-1, 1:2:4 (20 mm grade stone aggregate) Cement concrete in foundations, filling and mass concrete in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases)
M & L PCC type B-2, 1:2:4 (40 mm grade stone aggregate) slab flooring, beded and jointed in cement mortar 1:6 and painted in cement mortar 1:3 (100 mm thick) all as specified and as directed.
Adinath Technical Services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .