| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹2.2 Cr | L1 | Accepted-AOC Being lowest and reasonable. |
| 2 | L2₹2.4 Cr+₹13.3 L (5.91%)Rejected-Finance 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | ₹2.4 Cr+₹13.3 L (5.91%) | L2 | Rejected-Finance Other lowest. |
| 3 | L3₹2.6 Cr+₹38.6 L (17.2%)Rejected-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | ₹2.6 Cr+₹38.6 L (17.2%) | L3 | Rejected-Finance Other lowest. |
Tender Value
Refer Docs
EMD Value
₹3.2 L
Closing Date
27 Jul 2022, 6:00 pmClosed
Chief Engineer Delhi Zone
HQ CE Delhi Zone
ADDN/ALTN AND UPGRADATION OF MULTIPLE TEMP BLDGS AT 21 SIG GROUP AT ANAND PRABAT IN THE AREA OF AGE B/R-II UNDER GE (NORTH) DELHI CANTT
2022_MES_516243_1
CEDZ / TOKEN - 18 OF 2022
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt
Refer NIT Documents
9 documents required · 9 mandatory
₹2,000
GE North
₹3.2 L
Yes
7 Sept 2022
1 Apr 2022
29 Jul 2022
1 Apr 2022
27 Jul 2022
9 Jul 2022
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified.
Dismantling framed work timber scantling 40 sq cm and over in section and in any position complete all as specified.
Dismantling Wall & ceiling boards any thickness, including cover fillets etc complete all as specified and directed.
Dismantling unframed timber scantlings in fillets,rails, posts, rafters, purlins, etc under 40 sq. cm in section complte all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not other wise specifically provided for complete all as specified.
Demolition of Brickwork built in cement mortar including all quioins, arches, pillars etc complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each and removing to store complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but n.exc 4 sqm each and removing to store complete all as specified.
S&F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified.
S&F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified.
S&F Roof trusses (framed), trussed, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe -290 (Gde E-165) complete all as specified.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe -290 (Gde E-165) complete all as specified.
S&F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks, angle as in vertical pole, and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc confirming to Fe -290 (Gde E-165) complete all as specified.
S&F mild steel bolts. Purpose made. With hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut exc 30 cm long and dia exc 12 mm n.exc 20mm complete all as specified.
S & F MS plates (plain or chequered) channels, square cut or notched ordinary and counter sunk) forming holes, without any attachment confirming to Fe -290 (Gde E-165) complete all as specified.
M & L 4 mm thick size non asbestos fibre cement building boards fixed or laid / inserted to timber/ GI / Aluminium frame work with screws complete all as per manufacturers instructions and as directed.
S&F GI powder coated frame work of size 605 x 605 mm, for seamless celing comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling with cement mortar bedding, backing and dispose rubbish out off the premises complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick in CM 1:6 complete all as apecified and directed.
All as per Item No 19 above but on vertical surface as in dados/skirting over and including 10mm thick rendering as backing coat in CM 1:4 complete all as specified and directed.
M & L coloured Glazed ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in dado/skirting set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for non skid coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11Sqm and not exc 0.18Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match, over and including screed bed 15mm thick in CM 1:6 complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc. 0.50 cum, getting out , returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n exc. 50 m and making good surface.
M&L for cement concrete (1:2:4) using 20mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified.
M & L for Reused old brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified.
M & L Cutting holes in brick walls exc half bricks not exc one bricks built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
M & L for RCC type M-25 design mix using 20mm graded aggregates as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.
Form work to sides and soffits of floor or roof beam, beam haunchings, girders, bressum-mers, lintels, cantileverrs, shelves including supports, overhangs, etc also splays between floors and beams etc.for rough finished flat surfaces of concrete
M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality all as specified and directed.
M & L for mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to IS complete all as specified and directed.
M&L for preparation of old decorated previously treated surfaces of wall by brooming down scrapping down smoke and efflorescent etc.complete and applying two coats of oil bound distemper on wall complete all as specified and directed.
Taking down cement plaster on brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc.completeall as specified
M&L for 15mm thick Ready mix plaster in CM (1:6) on other than fair faces of brick work or concrete surfaces,using water proofing compound to be finished even and smooth without using extra cement, complete all as specified and directed.
M&L for prepartion of newly plastered surface of wall and applying 3 mm thick wall care putty two or more coat to get eeven and smooth surface (Birla white or equivalent) and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for 15mm thick Ready mix plaster in CM (1:4) on fair faces of brick work or concrete surfaces,using water proofing compound to be finished even and smooth without using extra cement, complete all as specified and directed.
M/L for preparation of newly plastered surfaces of any description and applying two coats of cement base paint over a coat of primer all as specified and directed.
M&L for preparation of old decorated surfaces of any description and applying two coats of cement base paint on external wall surface complete all as specified and directed.
S & F for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders; framed baluster; walk ways; railings; framework of watertanks and similar work confirming to Fe-290. Gde-E-165
S&F for 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F for 35mm thick, second class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc edges of framing plain, chamfered or rounded , fitted with cut and mitered beads for securing wire cloth etc,sizes of members of shutters as specified in SSR Part I, Section 8,clause 8.24(a) complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks/stainless steel wire staples complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for one coats of synthetic enamel paint on old steel painted surfaces including preparation of surfaces of any description not otherwise descriped over 10 cm width or grith complete all as specified and directed.
S&F Solid PVC factory made door frame of size 50x47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F for 200mm long aluminium anodised, barrel tower bolt , extruded section complete all as specified.
S&F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S&F 75 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed.
S&F for 150mm size extruded aluminium handle, fabricated type, anodised complete all as specified and directed.
S&F 300mm,Mild steel ordinary rat tailrod pattern springs including roller and roller plate complete.
S& F 250 mm long Aluminium alloy, anodised , sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S&F for anodised aluminium grill (anodised transparent or dyed to required shade accoring to IS : 1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to the existing window frame with CP . brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows & ventilators and partitions (fixed partition) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (fitting shall be paid separatly) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete all as specified and directed. Note:- The rate includes the cost of the materials and labour involved in all the operations described above for fixing of shutters.The cost of anchor bolts or screws for joining the frame is also included in this rate. Only any other hardware (i. e. tower bolt, sliding door bolt, handle , Glass etc), which may be required, shall be paid for separately.
S&F Figured glass 4.0mm thick, pin head type & glazing with oil putty in squares n exc 0.5 sq.m in each pane completed all as specified and directed.
S&F glazing of tinted glass 5.5mm thick in aluminium door window shutters and partitions etc with PVC/neoprene gasket etc Complete all as per specified and directed.
M&L brass coated aluminium decorative curtain rod 20mm dia including brackets, side knobs and fixed to wall complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-1 using 40mm graded stone aggregate, 75mm thick as in plinth protection/pavment , and the like, finish the surfaces even and fair without using extra cement complete all as directed and specified
Taking up or down steel tubing 15mm bore complete all as specified and directed.
Taking up or down steel tubing 20mm bore complete all as specified and directed.
S&F in 15mm bore tubes medium grade galvanized with all fittings andfixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good,cutting not exceeding 10cm girth
S&F in 20 mm bore tubes medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair 15mm bore bib taps cast copper alloy chromium plated with crutch or butterfly handle screwed down, complete all as specified and directed.
S & F Stop valves,fancy type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S & F Health haucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S & F CP toilet paper holder with flat recessed type stainless steel complete all as specified.
S&F CP soap dish fixed to wall with suitable rawl plug complete all as specified and directed. Make : Jaquar (AKP-35731P) or Prayag Cat Part No BA - 25 or equivalent.
S&F 20mm dia brass CP Tubular towel rail , D type, 60cm long between flanges complete all as specified and directed.
S&F in repairs Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain & plug & porcelain stopper but including brackets complete all as specified and directed.
M & L 32mm bore brass CP bottle traps for wash basins with inlet & outlet screwed for pipe or connections including necessary packing, union & cap. all as specified and directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white(including fixing bolts, flushing cistern & flush pipe) incl black seat cover complete all as specified and directed.
Supply only PVC low level flushing cistern valveless, 10 ltr capacity syphonic action type with inlet ball valve, float handle including brackets and (HDPE) flush pipe of 32mm dia with brass nut & washer, PVC connecting pipe, etc. connecting with WC inlet and making good the surface to match with existing complete all as directed and specified.
S&F PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed
S&F in 100 mm bore Cast iron soil,waste and vent pipes sand cast, in any length with or without ears, with cement joints,laid in trenches or in floors complete and including dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F 75mm bore Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) and fitted with oval access door complete all as specified and directed.
S&F in 75 mm bore Cast iron soil,waste and vent pipes sand cast, in any length with or without ears, with cement joints,laid in trenches or in floors complete complete all as specified and directed.
S&F in 100 mm bore Cast iron soil,waste and vent pipes sand cast, in any length with or without ears, with cement joints,fixed in wall complete complete all as specified and directed.
S & F 100mm cast iron cowls complete all as specified and directed.
S & F 100 mm dia stack clamp out of 50 mm by 5mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends ofstays to wall or roof
S&F 100mm bore Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed.
M & L in repair 75 mm CI floor traps including joint to waste pipe fixed in cement concrete B1 (1:2:4) complete all as specified and directed.
S & F Traps ‘P’ or ‘S’ 100mm complete all as specified and directed.
S & F 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches and fitted with oval access door complete all as specified and directed.
S & F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
S & F in repair greating doom 100mm dia PTMT (Minimum weight 25 gms) complete all as specified and directed
S& F in repair 15 mm dia brass CP Mixture for mixing hot and cold water screwed down for iron pipe and fixed.
Dismantling water tanks exc. 250 ltr & n.exc 500 ltr and removing complete all as specified and directed
Dismantling water tanks exc 500 ltr & n.exc 1000 ltr and removing complete all as specified and directed
S&F rotational moulded polythene water storage tanks, multi-layered, 500 Ltr capacity, cylindrical, vertical with closed top, hoisted and fixed in position including 20mm bore PTMT high pressure rate float valve with aluminium rod and ball screwed for iron pipe complete all as specified and directed.
S&F rotational moulded polythene water storage tanks, multi-layered, 1000Ltr capacity, cylindrical, vertical with closed top, hoisted and fixed in position including 20mm bore PTMT high pressure rate float valve with aluminium rod and ball screwed for iron pipe complete all as specified and directed.
S & F sink with draining board, made of Stainless steel out 1 mm thick for kitchen or laboratory with plugs, washers and wastes;including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 915mmx460mm with bowl size 410mm x330mm x160mm complete all as specified and directed.
S & F brass chromium plated shower rose 125mm size Complete all as specified.
S & F 150mm Floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc and getting out in soft/loose soil all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing surpluses excavated soil to a distance n.exc 50m and depositing at a level not exc 1.50m above the starting point complete all as specified and as directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M & L sand filling under floors including watering and consolidation complete all as specified
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls with clamps etc including taking out/dismantling of old pipes complete all as specified.
S&F PVC (SWR) bends any radius bore 110 mm
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
M&L in repair for Ultra design coloured tiles with PU coating of size 300x300x25 mm thick rubber moulded with white cement, as in floors incl over 15 mm thick screed bed in CM 1:6 jointed and pointed in neat cement slurry all as directed.
M & L machine pressed precast colour concrete interlocking paver block any shape and sizewith grey cement and pigment confirming to IS 15658-2006 of 60mm thickness,M-35 grade complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate)as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M & L for providing precast cement concrete type B1 (1:2:4) block masonary with solid blocks exc 10 cm in with and set in CM (1:4) complete all as specified and directed.
Supplying, laying and testing of 150mm dia SGSW (salt glazed stone ware) drain pipe grade 'A' laid in trenches to level/gradient, jointed in CM (1:1), all as specified for the following internal dia, complete all as specified and as directed by Engineer-in-Charge.
M&L for concrete bed to 150mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate including necessary shuttering and supports to concrete and for laying beds to falls complete all as specified and directed for the following bore of pipes :-
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in benching and coping of manholes etc including necessary form work, complete all as specified and as directed by Engineer-in-Charge.
M&L for providing precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded aggregate set as in CM 1:4 in man holes covers slabs all as specified.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150 mm dia pipes omplete all as specified and as directed.
M&L 40 mm thick plain cement concrete 1:2:4 type B-1 ( using 20 mm graded stone aggregate) as in floors finished even and smooth using extra cement all as specified.
Supply only Liquid integral water proofing compound complete all as specified and as directed.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified.
M & L for providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in copings,Bed blocks,and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified.
M&L for 15mm thick Ready mix plaster in CM (1:4) on fair/un-even surfaces of brick work or concrete surfaces,using water proofing compound to be finished even and smooth without using extra cement, complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm ditto
M&L for PCC 1:3:6 type C-1 (using 20 mm graded course aggregate) as in surface channels, drains, side guide wall including all necessary form work complete all as specified and directed.
Description of Work / Item(s)
Amount
Taking down copper/aluminium point wiring (light, fan,buzzer, socket or power & AC Points) complete, including fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets, light fitting etc. removing materials to store for keeping safe custody or for taking credit and making good disturbed surfaces of walls, floors etc as per existing all as specified and directed
Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, for light/fan pointPVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories, necessary fixing clamps, saddles of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc.,including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :-
(a) One light point controlled by one one way switch
(b) One fan point controlled by one one way switch
(c) One buzzer point controlled by one one way switch
(d) One 5 Amps 3/5 pin socket outlet on same board with other switches.
(e) One 5 Amps 3/6 pin socket outlet on independent board
Description all as per item no 2 above but with using 4 sq mm PVC insulated multi-stranded copper conductor for independent switch socket outlet 6 pin 5/15 Amps and incl 4.0 sqmm PVC insulated multi-stranded copper conductor single core as earth continuity conductor wire duly connected to all common earth point, drawn through 20 mm dia PVC conduit in any length all as directed at site.
Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, for light/fan pointPVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories, necessary fixing clamps, saddles, GI metal flush box of 1.60 mm thick suitable for modular type switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- (Note: Rates deemed to be included for GI modular metal flush box,modular plate covers inner and outer type, blanking plates etc complete).
(a) One light point controlled by one one way switch
(b) One fan point controlled by one one way switch
(c) One buzzer point controlled by one one way switch
(d) One 5 Amps 3/5 pin socket outlet on same board with other switches.
(e) One 5 Amps 3/6 pin socket outlet on independent board
Description all as per item no 04 above but with using 4 sq mm PVC insulated multi-stranded copper conductor for independent switch socket outlet 6 pin 5/15 Amps and incl 4.0 sqmm PVC insulated multi-stranded copper conductor single core as earth continuity conductor wire duly connected to all common earth point, drawn through 20 mm dia PVC conduit in any length all as directed at site.
S&F Switch piano flush type 5/6 Amps single pole one way 230 Volts complete
S&F Switch piano flush type 15/16 A single pole one way 230 Volts complete
S&F Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volt complete
S&F Socket Outlet 2 in 1, 3/6 pin 5 and 15 Amp flush type 230 Volts complete
S/F Bell push, flush type 5 Amps 230 Volts complete
S&F electronic fan step regulator flush type 120 watt, 230 Volt complete
S&F modular switch 6/10 Amps, one way, one module 240 volts complete
S&F modular socket, 3 pin 6/10 Amps,240 volts, 2 module complete
S&F modular switch 16 A, 1 module,240 volts complete
S&F modular socket 6/16 A, 5 pin, 2 module, 240 volts complete
S&F modular Bell push 6 Amps, one module 240 volts complete
S&F modular fan regulator, step type, 120 W, humfree, AC, 230 volts, 2 module complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F lamp holder, 230 volt AC, PVC / Polycarbonate type of angular shape with back plate suitable for batten fittings complete
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete.
M&L For Sub main wiring with 6 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 6 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed.
Supply and fixing loadline distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415V AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable for MCCB, 63 Amps as incomer and MCB,SP as out going all as directed.
S & F Sheet metal enclosure DB 8 way,Single pole and neutral with 200 Amps rated bus bar,230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs & arrangements, all as specified and directed.
S&F MCB, DP, 240 Volts, AC 32/40 Amps of breaking capacity 10 KA C curve of sizes.
S&F MCB SP 240 Volts AC 6 - 40 Amps of breaking capacity 10 KA C curve.
S&F sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB with 20 Amps complete.
S & F LED Batten type fitting for surface/wall mounted 22W,230V,6500K integrated electronic driver completely pre wired, LED 4 feet fitting with polycarbonate housing & integrated electronic driver complete with connector blok, screws , gutties etc.and removing the UNSV fitting and all as specified and directed.
S & F LED Batten type fitting for surface/wall mounted 9W,230V,6500K integrated electronic driver completely pre wired, LED 2 feet fitting with polycarbonate housing & integrated electronic driver complete with connector blok, screws , gutties etc.and removing the UNSV fitting and all as specified and directed.
S&F bldg security light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 65 protection and 25 watt with suitabe size GI pipe bracket,clamps incl taking down old unserviceable one all specified and directed.
S&F Indoor Decorative wall light fixture suitable for 12 W LED lamp,230V for soft light ambiance, plastic diffuser with painted CRCA bracket, B22 lamp holder used,cylindrical shape, fixed on wall with the help of screws incl LED lamp 9 /12W and remove the UNSV fittings and all as specified and directed.
Supply and fixing of High speed ceiling fan energy efficient, BLDC motor type 5 star rated in white colour 1400mm sweep 220-240 volt with one set of 3 blades, down rod, hanger clamping, PVC canopy complete all as specified and directed.
Supply and fixing of 200mm dia, 900 RPM, fresh air ventilation fan with plastic blades, louvers incl frame, blades incl making hole and making good the diturbed area complete all as specified and directed.
Supply and fixing of 300mm dia, 900 RPM, heavy duty exhast fan witlh louvers including frame, blades incl making hole and making good the disturbed area complete all as specified and directed.
Supply and fixing of Water heater storage type, electric, capacity 25 Ltrs BEE 5 star rated, wattage 2KW, ABS plastic body, temparature indicating dial, enamel coated heating element, glass line coated inner tank, magnesium anode type, adjustable thermostat, inlet (cold water) and out let(Hot water) pipes incl fixing with fasteners at wall and making good, finishing to disturbed surface to match the existing surface incl connection complete.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised iron wire of size 4mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or DB's/Indoor type LT PBs or any other indicated situation for loop earthing etc. 4mm dia galvanised iron or steel wire all as specified and directed.
Supply and laying galvanised steel water tubing 50 mm dia medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends,elbow,tees,short pieces,connectors,caps,plugs and unions,etc) and fixing complete with clips,wall hookswooden plugs,or laying in trenches,etc.,also cutting,screwing and waste and for making forged bends on piping as required complete all as specified and directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 20 mm dia.
Supply and fixing gunmetal gate valve 50 mm dia screwed down high pressure with iron wheel head, screwed both ends for iron pipe.
Supply and fixing gunmetal gate valve 20 mm dia screwed down high pressure with iron wheel head, screwed both ends for iron pipe.
M&L for Construction of valve chambers 900 mmx900mmx900 mm with 15 cm thick solid concrete block masonary,block casted using PCC 1:3:6 type C-1mix built in cement and sand mortar 1:4,15 mm plaster to thick internal surface and external surface up to 15 cm below ground level and top of floor in CM 1:4 finished even and smooth without using extra cement 15 mm thick,MS sheet cover 3.15mm thick including 50x50x6 mm MS angle frame embedded in 150 mm thick PCC 1:2:4 type B-1,with 25x6 mm flat iron hold fast,handles,hinges with locking arrangments, applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface and earth work in type of soil.
M&L for cutting the existing pipe line 80/100 mm dia and fixing the suitable tee 80x40x80/100x40x100 mm dia and all as specified and directed.
Taking down old unsv GI pipe of 20 to 50 mm dia from in trenches/surface on walls complete.
Taking down old unsv Gate valves of 20 to 50 mm dia complete
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable/pipes in any type of soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core
M&L for Steel Tubular Pole 410 SP-31 (9 metres long) complete with cast iron base plate, finial taper plug, nuts, bolts and washers all as specified including loop junction box (3 phase/1 phase system) to be fixed at bottom of pole with one MCB SP 10 amp, outdoor type complete incl the followings :- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points. (b) Providing PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in foundations up to ground level complete (Size 1.57 x0.9 x0.9 Mtrs). (c) Providing PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation including necessary form work with cement mortor 1:4 for plinth block/collar above GL(Size 0.45x0.45x0.45 Mtrs) all as specified and directed. (d) The complete embedded portion shall be painted with two coats of black bituminus paint. Painting of Poles with two coats of aluminium paint over a coat of red oxide primer in full length of pole. Black and yellow strips up to 1.5mtr over a PCC coping alternatively including numbering the pole complete
S&F street light LED street light 45 watt IP 66 incl street light bracket suitable for street/security light fittings upto 1.5 RM make out of GI pipe of light grade up to 40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed complete all as directed and specified .
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI strip 32 x 6mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20mm bore light grade, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point/equipment and testing complete
M & L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI earth wire 4mm dia by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20mm bore light grade, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point/equipment and testing complete
M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover all as specified and directed
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed.
M & L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed.
M & L for steel tubes, light grade galvanised 80 mm bore laid in trenches/walls and spreading for cable cushioning/protection all as specified and directed.
M & L for steel tubes, light grade galvanised 50 mm bore laid in trenches/walls and spreading for cable cushioning/protection all as specified and directed.
M&L for PVC, sheathed copper cable of 2.5 sqmm, 3 core for street light connection from steel pole /PCC pole /Jn box complete all as directed
V M CONSTRUCTION
GLIBS CONSTRUCTION
V M CONSTRUCTION
GLIBS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .