Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.7 LAccepted-AOC VPO ALAWALPUR TEH AND DISTT PALWAL 121102 | ALAWALPUR | PALWAL | HARYANA | 121102 | ₹99.7 L Quoted ₹99.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹1.1 CrRejected-Finance H NO 02 NEAR GOVT BOYS SR SEC SCHOOL 121102 | PALWAL | HARYANA | 121102 | ₹1.1 Cr | L2 | Rejected-Finance Reject due to higher rate quoted |
| 3 | L3₹1.1 CrRejected-Finance | ₹1.1 Cr | L3 | Rejected-Finance Reject due to higher rate quoted |
| 4 | Not Admitted-Fee/PreQual/Technical VILLAGE LOHINA TEHSIL HODAL DISTRICT PALWAL 121106 | LOHINA | PALWAL | HARYANA | 121106 | - | - | Not Admitted-Fee/PreQual/Technical Others-As per Notification 480-C-7-2025/4728 dated 27.06.2025 work upto One Crore is reserved for Cooperative Labour and Construction Societies. Therefore agency is not considered for Technical Evaluation |
| 5 | Not Admitted-Fee/PreQual/Technical H NO 12 N EXTENSION NEW PALAM VIHAR GURUGRAM H NO 12 N EXTENSION NEW PALAM VIHAR GURUGRAM 122001 | GURUGRAM | HARYANA | 122001 | - | - | Not Admitted-Fee/PreQual/Technical Others-As per Notification 480-C-7-2025/4728 dated 27.06.2025 work upto One Crore is reserved for Cooperative Labour and Construction Societies. Therefore agency is not considered for Technical Evaluation |
Tender Value
₹97.8 L
EMD Value
₹2.0 L
Closing Date
9 Mar 2026, 5:00 pmClosed
MANOJ KUMAR
Municipal Council Palwal
Construction of Road (RMC Road) and drain from Ramkishan ki Dukan to Dalip Sarpanch, Birpal to Ramphal, Birpal to Sitaram, Sita Ram to Lal Cand, Lal Chand to Hari Ram Hari Ram to Karishan Garden via HO Pappu and Krishna Garden to Patli Road ward 30
2026_HRY_505184_1
20265ED115EE DDC5 4128 AE2E D2ADD0E334B3294ULB
Open Tender
Civil Works
180 days
Palwal
2 documents required · 2 mandatory
₹5,000
₹2.0 L
Yes
16 Apr 2026
26 Feb 2026
10 Mar 2026
26 Feb 2026
9 Mar 2026
26 Feb 2026
[10.17]Providing and laying polythene sheet under CC M-25 in road and parking complete in all respect [Through Rate]
[10.8]Providing and laying of conglomerate floor 40mm thick cement concrete topping 1:2:4 [Through Rate]
[11.8.1]12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) [Through Rate]
[13.29.1]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete [Through Rate]
[17.13]Granular Sub-Base (Mix in place) Construction of granular sub-base by providing Material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H technical specifications [Through Rate]
[17.23.2]Water Bound Macadam Grading - II 2. Water Bound Macadam - II with Screening Type A / Type B Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications [Through Rate]
[17.6]Construction of Embankment with Material obtained from Borrow pits NA Construction of Embankment CBR 8% (for new road/ raising/ berms/ etc.) with approved material obtained from borrow pits, including compensation of earth with all lead and lift transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2, as per technical clause 305 of MORT&H specifications. [Through Rate]
[17.70]Removal of existing IPB by manual means and disposal of dismantled material with all lead and lift as per technical specification clause 202.3. [Through Rate]
[21.52]Constructing standard drain, type house connection complete consisting of concrete drain moulded and laid over lime concrete foundation rendered and finished smooth with 6mm thick rendering concrete to be of 1:3:6 parts by volume of cement sand stone bajri and rendering to be 1:1 cement sand mortar. [Through Rate]
[21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate]
[6.22.1.3]Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1.3. All works above plinth and up to floor IV level : M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) [Through Rate]
[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]
[6.26.3]Extra for providing richer mixes up to plinth and at all floor levels. 3. Providing M-40 grade concrete instead of M-25 grade BMC/ RMC.(Note : Cement content considered in M-40 is @ 360 kg/ cum) [Through Rate]
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Material Rate]
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
technical_583907.pdf
techsummary_583907.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_583907.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid