| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹8.8 L+₹1.5 L (20.0%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹9.7 L+₹2.3 L (31.9%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
26 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RANGIA
GE Rangia C/O 99 APO Rangia
REPAIR/ REPLACEMENT AND CLEANING OF SEWAGE LINES, MANHOLES, SEPTIC TANKS AND CONNECTED WORKS AT TAMULPUR AND DARRANGA MILITARY STATION UNDER GE RANGIA
2020_MES_372823_1
8396/E8
Open Tender
Civil Works
Item Rate
180 days
TAMULPUR AND DARRANGA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE RANGIA
₹16,000
Yes
1 Oct 2020
29 Aug 2020
28 Sept 2020
29 Aug 2020
26 Sept 2020
14 Sept 2020
60 days
Amount
M&L for cleaning of septic tanks of any capacity mechanically along with removing of sludges etc and carrying to a distance exc. 100 meters but n.exc 250 meters and depositing in ditches including necessary excavation and earth work in soft/loose soil for making ditches and refilling the ditches after the sludge’s are deposited with spreading and leveling of excavated soils in the ditches over the sludge, removing surplus soils to a distance n.exc 50m and supply and sprinkling bleaching powder over the area of ditches with one meter around complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 1 above but for cleaning of manholes of any size and depth.
M & L for cleaning of cast iron pipe 100mm dia (internal) by rodding/pumping carefully from water closet to first manholes/inspection chamber or cleaning eye and removing all blockage in pipe lines and well flushing with water including making good of leakage in joint wherever required in cement mortar (1:2) complete all as specified and as directed by Engineer-in-charge.
M & L for cleaning of salt glazed stone ware (SGSW) sewage pipe line 150mm dia (internal) by rodding/pumping between intermediate/1st manholes to manholes or between manholes to septic tanks or between septic tank to soak pits to remove all blockage and well flushing with water including making good of leakage in joints wherever required in cement mortar (1:2) complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 4 above but for salt glazed stone ware (SGSW) sewage pipe lines of 100mm dia (internal).
Demolition of brick work built in cement mortar at foul positions complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub class ‘B; bricks (using old size bricks) straight or curved on plan exc 6.00 meter mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Dismantaling of cast iron or reinforced concrete drain pipes 200mm dia (internal) jointed in cement mortar and taking out from the trenches complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced concrete pipes,class NP2, laid and jointed complete with collars with internal dia. of pipe 200 mm complete all as specified and as directed by Engineer-in-charge.
Demolition and breaking up including removing salt glazed stoneware pipe 150mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 10 above but 100mm bore (internal) sewage pipe lines.
M&L for 100mm dia (internal) salt glazed stone ware drain pipes (Grade A) ISI Marked as in sewage lines laid in trenches and jointed complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 12 above but of 150mm dia.
M&L for cement concrete bed to drain pipe 100mm bore (Internal) in cement concrete (1:4:8) type D-2 with using 40mm graded crushed stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested all complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 14 above but for 150mm bore (internal) pipe lines.
All as per serial item No. 14 above but for 200mm bore (internal) pipe lines.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, complete all as per specified and as directed by Engineer-in-charge.
M&L for pre-cast reinforced cement concrete (1:2:4) type B-1 with using 20mm graded crushed stone aggregate as in cover slabs of manholes, gully traps, septic tanks etc with plain faces set in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
S&F 10mm dia and over TMT bar cut to length bent to shape required including cranking, bending and binding with M.S wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound on other than fair faces of brick work of concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. (Note - WPC shall be measured and paid separately).
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floor including taking down old unserviceable pipe complete all as specified and as directed by Engineer-in-charge.
S&F 110 mm PVC (SWR) bends complete all as specified and as directed by Engineer-in-charge.
Supply only integral water proofing compound ISI marked complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S Rajkamal Enterprise
M/S SITAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .