Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-Finance | L1 | Accepted-Finance The Qouted rates first lowest minimum | |
| 2 | L2₹1.1 L+₹1,315 (1.16%)Accepted-Finance 113 F BLOCK HOUSE NUMBER 113 F BLOCK PANKI KANPUR NAGAR UTTAR PRADESH 208020 | KANPUR NAGAR | UTTAR PRADESH | 208020 | L2 | Accepted-Finance The Qouted rates second lowest minimum | |
| 3 | L3₹1.2 L+₹2,375 (2.09%)Accepted-Finance | L3 | Accepted-Finance The Qouted rates third lowest minimum |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
1 Apr 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
57-George Town ETD -IV Prayagraj
For replacement of defective electro mechanical relays of 33 KV capacitor bank panel (2x5 MVAR) with numerical relay at 132 KV S/S manauri under ETD-IV, Prayagraj
2024_UPTCL_919855_1
19 ETD-IV(P)/2023-24
Open Tender
Electrical Works
Item Rate
60 days
132 KV S/S Manauri
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer ETD IV, Prayagraj
₹2,000
Yes
30 Apr 2024
22 Mar 2024
1 Apr 2024
22 Mar 2024
1 Apr 2024
22 Mar 2024
Amount
Supply and retrofitting of old, used and defective 33 KV Electromechanical O/C & E/F relay, Under Voltage relay, Over Voltage relay and Neutral Displacement Relay (NDR) suitable for 33 KV Capacitor Bank unit (2x5 MVAR) installed at 132 KV S/S Manauri as per following works. Supply of Numerical O/C & E/F relay (IDMT 50/51N) with time delayed of ABB/Siemens make having atleast 6BI, 6BO with 01 alarm output, Auxiliary supply-1Amp suitable for 110 V DC auxiliary voltage with communication interface RS-485 for 33 KV Capacitor Bank Panel (2x5 MVAR) as per sample.
Supply of Numerical Under Voltage relay, Over Voltage relay alongwith Trip circuit supervision relay of ABB/Siemens make having one alarm output, Auxiliary supply-1Amp suitable for 110V DC auxiliary voltage for 33 KV Capacitor Bank Panel (2x5 MVAR). PT ratio-33 KV/110V
Supply of Numerical 86 Relay of ABB/Siemens make at 132 KV S/S Manauri for 33 KV C&R Panel of Capacitor Bank.
Retrofitting of New Numerical O/C & E/F relay (IDMT 50/51N) with time delayed relay by dismantling of old and defective electro mechanical 50/51N Non Directional O/C & E/F relay installed in C&R panel of 33 KV Capacitor Bank (2x5 MVAR) at 132 KV S/S Manauri by fabricating MS sheet as well as testing & commissioning of these relays with all other associated work.
Retrofitting of new Numerical under voltage relay, Over Voltage relay alongwith Trip circuit supervision relay and 86 relay by dismantling of old and defective electro mechanical Over/Under Voltage and NDR relay installed in C&R panel of 33 KV Capacitor Bank (2x5 MVAR) at 132 KV S/S Manauri by fabricating MS sheet as well as testing & commissioning of these relays with all other associated work.
B.R. ENTERPRISES
M/S OM SHANTI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .