Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L1 | Accepted-AOC DUE TO L1 RATE | |
| 2 | L2₹15.0 L+₹2.2 L (17.5%)Rejected-Finance A T T MILL COMPOUND BLOCK TINALI MARGHERITA MARGHERITA TINSUKIA ASSAM 786181 | TINSUKIA | ASSAM | 786181 | L2 | Rejected-Finance DUE RATE HIGH |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
13 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
GE LEKHAPANI, TINSUKIA, ASSAM
REPAIR/MAINT OF FEEDER PILLAR BOX, PANELS AND ITS ALLIED SERVICES AT LEKHAPANI MIL STN UNDER GE LEKHAPANI
2022_MES_557907_2
8701/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E Category b(I)
4 documents required · 4 mandatory
₹500
GE Lekhapani
₹29,800
Yes
28 Dec 2022
21 Nov 2022
16 Dec 2022
21 Nov 2022
13 Dec 2022
29 Nov 2022
Amount
M&L for Fabricate, install, testing and commissioning of Distribution board, pedestal and compartmental type suitable size enclosures cubical weather and vermin proof totally enclosed made out of 2.0 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ single door with front openable and PVC acrylic glass cover suitable size for checking of meter reading without opening door with locking arrangement incl inner shutters for mounting switch gear etc, suitable arrangement for fixing of electrical meter and SPN 40 Amp including pre wiring from Bus bar to Meter and Meter to MCB SPN (for pre wiring use 6.00 Sqmm Single core copper cable and suitable size of lugs for connection) including bottom gland plate with sufficient numbers of circular cable entry holes, prewired complete incl cutting wall and fixing panel partially inside wall and making good disturbed surfaces with necessary civil work and connection complete all as specified and directed by Eng-in-charge. The panel will comprise of the following:- INCOMING :- (i) MCCB 100 Amps FP, 415 Volt 10 KA adjustable thermal & fixed magnetic setting Ics = 100% = 01 No (ii) Phase indicating lamp LED type – 1 Set of three. (iii) Aluminium bus bar 150 Amps capacity with bus bar supports, DMC/SMC insulators of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUT GOING (i) MCB 63 Amp, 415 Volt, Single pole and neutral, 'C' Series, breaking capacity 10 kA -05 Nos (ii) S&F single phase electronic energy meter with LCD display of rating 10-60 Amp class 1.0, 240V 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire .-04 Nos
M&L for Fabricate, install, testing and commissioning of Distribution board, pedestal and compartmental type suitable size enclosures cubical weather and vermin proof totally enclosed made out of 2.0 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ single door with front openable and PVC acrylic glass cover suitable size for checking of meter reading without opening door with locking arrangement incl inner shutters for mounting switch gear etc, suitable arrangement for fixing of electrical meter and SPN 40 Amp including pre wiring from MCCB to Meter and Meter to MCB SPN (for pre wiring use 6.00 Sqmm Single core copper cable and suitable size of lugs for connection) including bottom gland plate with sufficient numbers of circular cable entry holes, prewired complete incl cutting wall and fixing panel partially inside wall and making good disturbed surfaces with necessary civil work and connection complete all as specified and directed by Eng-in-charge. The panel will comprise of the following:- INCOMING :- (i) MCCB 100 Amps FP, 415 Volt 25 KA adjustable thermal & fixed magnetic setting Ics = 100% = 01 No (ii) Phase indicating lamp LED type – 1 Set of three. OUT GOING (i) MCB 63 Amp,415 Volt, Single pole and neutral, 'C' Series, breaking capacity 10 kA -03 Nos (ii) S&F single phase electronic energy meter with LCD display of rating 10-60 Amp class 1.0, 240V 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire -02 Nos
Taking down old damaged panel door wings, cleaning, etc and S&F new hinges of suitable size fixing either by welding or with screws,as required at site including applying of two coats of synthetic enamel paint of approved colour over a coat of primer complete all as specified and directed by Eng-in-charge.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures etc complete from existing main boards and removing from site all complete all as directed.
S&F Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link complete all as directed by Engineer-in-Charge.
S&F Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 4 way (2 + 2 way) single pole and neutral link complete all as directed by Engineer-in-Charge.
Taking down old un serviceable MCB SPN and S&F MCB single pole and neutral (SP&N) 25 to 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs complete all as specified and directed.
Taking down old un serviceable MCB SP and S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'B' series with all incoming/outgoing connection with proper size lugs complete all as specified and directed.
Taking down old un serviceable MCCB DB TPN and S&F sheet metal enclousure MCCB DB TPN (without MCCB) double door type AC 415 V 4 way with 200 Amps rated bus bar vertical type, having provn for fixing MCCB as incomer, flush to wall and making good of disturbed surface complete all as specifed and directed.
S&F MCCB Triple pole & Neutral 100Amps, 35KA breaking capacity with adjustable microprocessor release complete all as specified and directed
Taking down old un serviceable panel meter and S & F 3 phase digital Panel Meter class 1 accuracy class 0.5 input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300VAC, flush mounting 96 mm X 96 mm including inbuilt CT/PT site programmable including making connection with copper conductor cable of suitable size complete all as specified and as directed.
Taking down old un serviceable volt meter and S & F in 3 phase digital voltmeter class 1 accuracy class 0.5 input voltage measurement range 17-520 VAC (P-P), Aux supply 90-300VAC, flush mounting 96 mm X 96 mm including inbuilt CT/PT site programmable including making connection with copper conductor cable of suitable size complete all as specified and as directed.
Taking down old un serviceable ammeter and S & F in repairs 3 phase 5A class 1 digital Ammeter accuracy class 0.5 input voltage measurement range 17-520 VAC (P-P), Aux supply 90-300VAC, flush mounting 96 mm X 96 mm including inbuilt CT/PT site programmable including making connection with copper conductor cable of suitable size complete all as specified and as directed.
Taking down old un serviceable sub main wiring and M&L sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated flame retardant unsheathed multi stranded copper conductor cable 1100 volts grade drawing through rigid PVC casing caping medium grade complete including 6.00 Sqmm PVC insulated unsheathed multi stranded flame retardant single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Two runs of single core 6.00 Sqmm multi stranded copper cable and one run of 6.00 Sqmm earth wire and one run of casing caping shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the conduit.
Taking down old un serviceable sub main wiring and M&L sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated flame retardant unsheathed multi stranded copper conductor cable 1100 volts grade drawing through rigid PVC casing caping medium grade complete including 4.00 Sqmm PVC insulated unsheathed multi stranded flame retardant single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Two runs of single core 4.00 Sqmm multi stranded copper cable and one run of 4.00 Sqmm earth wire and one run of casing caping shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the conduit.
Taking down old un serviceable on load change over switch and S&F On load change over switch 100 Amps, 415V, AC 50 Hz, front operated handle, totally enclosed in sheet metal enclosure including fixing on wall with suitable accessories and connecting the cable end with suitable size lugs, nuts/bolts/washers etc complete all as specified and directed by Eng-in-charge.
Taking down old un serviceable prime capacitor and S& F Standard duty prime capacitor of the self-healing type 3 KVAR, suitable for indoor use, ambient air temperature categories -5/C, box type, suitable for 415 V, 50 Hz AC supply including PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc. complete all as specified and directed by Eng-in-charge.
All as per item No 18 above but of capacity 5 KVAR complete all as specified and directed by Eng-in-charge. .
All as per item No 18 above but of capacity 7.5 KVAR complete all as specified and directed by Eng-in-charge. .
All as per item No 18 above but of capacity 10 KVAR complete all as specified and directed by Eng-in-charge.
All as per item No 18 above but of capacity 15 KVAR complete all as specified and directed by Eng-in-charge.
Taking down old un serviceable APFC Relay and S & F APFC relay 12 stage steps description 11 + 1* with auto set functioning as per catalogue part No ERPML12D500 of Make L&T or equivalent of Make as mentioned under Appendix "B" including PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc. complete all as specified and directed by Eng-in-charge.
Taking down old un serviceable APFC Relay and S & F APFC relay 8 stage steps description 7 + 1* with auto set functioning as per catalogue part No ERPML08D500 of Make L&T or equivalent of Make as mentioned under Appendix "B" including PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc. complete all as specified and directed by Eng-in-charge.
Taking down old un serviceable Capacitor and S & F Contactor, three pole, suitable for 3 KVAR capacitor, 415 V, 50 Hz AC supply including PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc. complete all as specified and directed by Eng-in-charge.
All as per item No 25 above but of capacity 8.5 KVAR.complete all as specified and directed by Eng-in-charge.
All as per item No 25 above but of capacity 12.5 KVAR.complete all as specified and directed by Eng-in-charge.
All as per item No 25 above but of capacity 15 KVAR.complete all as specified and directed by Eng-in-charge.
M&L Earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth strip 25 x 4 mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways and testing on completion,etc complete all as specified & directed by Engineer-in-Charge.
M&L Earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways and testing on completion,etc complete all as specified & directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out/for laying under ground cables/pipes etc and getting out in soft/loose soil ,complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm complete all as specified and directed.
Removing excavated soil to a distance n-exc 50 m and depositing where directed at a level n-exc 1.5 m above the starting point complete all as specified and directed.
Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts all as directed by Engr-in-Charge at site Note : - Only punned thickness shall be measured for payment purpose
Supply and laying old size brick, size 230x115x75mm burnt clay building bricks sub class (B) for protecting LT U/G cable,complete all as specified and directed.
Supply,laying and testing of LT UG cable XLPE insulated heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 2 core 16 sq mm including taking out old unserviceable cable complete all as specified and directed.
All as per item No 36 above but 35 sq mm 3.5 core complete all as specified and directed.
All as per item No 36 above but 70 sq mm 3.5 core complete all as specified and directed.
All as per item No 36 above but 300 sq mm 3.5 core complete all as specified and directed.
Supply and jointing of straight through joint kit epoxy type suitable for XLPE LT UG cable upto 3.5 core 25-50 sq mm 1100 volts grade including ferrules as per required size.
S & F Aluminium Bus bar chamber of capacity 63 Amps, four pole, 415 volts, AC supply, mounted on DMC type insulators, totally enclosed with metal body/rigid PVC enclosure, complete including opening for cable entry all as specified & directed. .
S&F 80 mm dia GI pipe (light grade) including fittings for cable protection , laid in trenches or fixed on pole/wall for passing LT cables including taking out old rusted pipe complete all as specified and directed.
All as per item No 42 above but 40 mm dia complete all as specified and directed.
M/S. MATA VAISHNO DEVI ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .