Major S K Yadav GE(S) BATHINDA
GE(S)Bathinda Bathinda Mil Stn
GE(S) BTD TOKEN NO 83 OF 2023-24 PERVISION OF CERTAIN REVENUE MINOR AND SPECIAL REPAIR WORKS UNDER AGE BR I AGE BR II AND AGE EM IV UNDER GARRISON ENGINEER (SOUTH) BATHINDA AT BATHINDA MILITARY STATION
2023_MES_632425_1
GE(S)/BTD/TOKEN NO 83 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE(S)Bathinda
Class D
category a(i) and b(i)
9 documents required · 9 mandatory
₹500
GE(S)Bathinda
₹85,400
Yes
12 Feb 2024
12 Dec 2023
11 Jan 2024
12 Dec 2023
9 Jan 2024
26 Dec 2023
Amount
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 m depth for foundation etc. and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches exceeding 1.50m wide and not exceeding 3.0m depth for foundation etc. and getting out in soft/loose soil complete all as specified and as directed.
M & L for PCC (1:4:8) type D-2, using 40mm graded stone aggregates as in foundation filling & mass concrete complete all as specified and as directed.
M & L 100mm thick PCC (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base for flooring complete all as specified and as directed.
M & L Brick work built in CM 1:6 with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
M & L Brick work built in CM 1:4 with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
Ditto all as per item No 6 above but half brick wall built in CM 1:4 complete all as specified and as directed.
M & L for DPC (1:2:4) type B-0 to horizontal or vertical surfaces including necessary form work 40 mm thick complete all as specified and as directed.
M & L RCC 1:2:4 using 20 mm graded aggregate foundation, including rafts, footings, foundation beams, plinth beams, bases for columns and mass concrete etc. complete all as specified and as directed.
M & L RCC 1:2:4 .using 20 mm graded aggregate for slabs support on walls beams and columns, in floors roofs landings balconies etc. complete all as specified and as directed.
M & L RCC 1:2:4 type B1 using 20 mm graded aggregate for columns, pillars, piers and post etc. complete all as specified and as directed.
All as per item 11 here in before but in lintels complete all as specified and as directed.
M & L form work for soffits and sides of suspended slabs such roof slabs, floor slabs, landing and similar works not exceeding 200 mm thick (horizontal or soffits) rough finished surfaces of concrete flat complete all as specified and as directed.
M & L form work for sides of concrete rough finished surfaces of concrete foundation, footings and base of columns raft and raft beams rough finished surfaces of concrete flat complete all as specified and as directed.
M & L form work for sides of pillars, posts, struts, piers, columns and stanchion rough finished surfaces of concrete flat complete all as specified and as directed.
M & L TMT bars 10 mm dia and over cut to length bent to shape required, including cranking and binding spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed.
Ditto all as per item 16 above but 5 mm dia and over up to including 10 mm dia in stirrups spacers and binders complete all as specified and as directed.
M & L rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finishing even and smooth without using extra cement complete all as specified and as directed.
Ditto all as per item 15 above but 15 mm thick on other than fare faces of brick work in CM 1:6 complete all as specified and as directed.
Ditto all as per item 15 above but 5 mm thick on ceiling in CM 1:3 complete all as specified and as directed.
M & L hard core of gauge not exceeding 63 mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface with broken bricks bats complete all as specified and as directed.
M & L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate surface finished even and smooth using extra cement as in flooring complete all as specified and as directed.
S & F solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and fixing in opening as per specification and drawing complete all as specified and as directed.
S & F factory made solid panel PVC door shutter 28 to 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail and bottom rail on either side and gap insert for top rail and bottom rail: Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site as per specification and drawing complete all as specified and as directed.
S&F 100 mm long extruded aluminium alloy butt hinges fixed to PVC door with screws complete all as specified and as directed.
S&F aluminium anodiesed barrel tower bolt of extruded section size 150 mm complete all as specified and as directed.
S&F aluminium handles cast type anodized size 125 mm long complete all as specified and as directed.
S&F for pressed steel frames of size 105 X 60 mm with one or more rebates including necessary fixing lugs hinges, locks strike plate etc (thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6 complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1 (using 20mm gde stone agg) as in filling of Chowkhats complete all as specified and as directed.
M & L 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
M&L for preparation of new wood and wood based surfaces of any description exc 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description exc 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S & F vitreous china wash basin, white, flat back, size 550 x 400mm excluding taps, wastes but including brackets complete all as specified and as directed.
S & F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
M & L 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
S & F Jet spray, CP, brass body with wall hook and 1 mtr SS pipe complete all as specified and as directed.
S & F health faucet brass body with wall hook and 1 mtr SS pipe complete all as specified and as directed.
S&F vitreous china wash down water closet pan (pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, ant-syphonage pipe, etc. complete all as specified and as directed.
S & F in repairs 110 mm bore of 6 kg/CM Square pressure fixed to walls with MS clamps of 25 x 3 mm flat iron and fixed with 75 mm long screw with PVC gutties n.exc .1.80 mtr centre to centre distance complete all as specified and as directed.
S & F 10 litre capacity PVC valve less syphonic action type flushing cistern low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
S & F 15mm bore tubes medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc. complete all as specified and as directed.
S & F 20mm bore tubes medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc. complete all as specified and as directed.
S&F 1000 litre capacity rotational moulded polyethylene water storage, tanks (Cylindrical, vertical with closed top) hoisted and fixed in position including all fittings complete all as specified and as directed.
S & F cast copper alloy, chromium plated bib tap for 15 mm bore of pipe screwed down, screwed for iron pipe or for brass furrel and fixed complete all as specified and as directed.
S & F cast copper alloy, Chromium plated angular stop valves for 15 mm bore of pipe screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S & F 20mm bore Ball brass valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F cast iron sand cast 100mm size soil waste or vent pipe without ears with cement joint laid in wall/floors/trenches complete all as specified and as directed.
S&F cast iron sand cast 75mm size soil waste or vent pipe without ears with cement joint laid in wall/floors/trenches complete all as specified and as directed.
S&F Cl bend 100 mm bore with heal rest complete all as specified and as directed.
S&F 100 mm bore, CI branch pieces single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed.
S&F Cl cowl 100 mm bore complete all as specified and as directed.
M & F salt-glazed stoneware gully trap square mounted etc S type 150 x 150 mm size complete all as specified and as directed.
M&L for non skid ceramic coloured tiles jointfree, in floors etc., 7 to 8 mm thick set and jointed in neat cement slurry and pointed to match including 15 mm thick screed (1:4) as in floor etc, area exc 0.11 sqm but n.exc 0.18 sqm complete all as specified and as directed.
M&L for ceramic glazed coloured tiles jointfree 450x350x7 mm thick in skirting/dado etc set and jointed in neat cement slurry and pointed to match the surfaces etc, over and including10mm thick plaster in CM 1:4, complete all as specified and as directed.
S&F CP grating 150 mm size square fixed on gully trap etc complete all as specified and as directed.
Supply and laying salt glazed stone ware drain pipes 150 mm bore trenches and jointed with cement complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; of 150 mm dia pipes complete all as specified and as directed.
S&F 100 mm dia cast iron floor trap with grating including jointing to waste pipe in run lead complete all as specified and as directed.
M & L for 75mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in plinth protection and path finished surfaces smooth and even without using extra cement complete all as specified and as directed.
M & L Continuous brick edging 75mm wide with brick laid on end vertically with sub class 'B' brick complete all as specified and as directed.
M & L preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
All as per item 61 here in before but three coat of white wash in ceiling complete all as specified and as directed.
All as per item 61 here in before but three coat of white wash on walls complete all as specified and as directed.
M & L returning filling including spreading levelling watering and well ramming in layers n exc 25 cm in soft/loose soil complete all as specified and as directed.
M & L removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed.
S & F 15mm bore chromium plated quarter turn pillar taps screwed down high pressure with or without lettered Hot or Cold with ling screwed shanks/flunuts screwed for iron pipe complete all as specified and as directed.
S&F 32 mm bore of pipe low density (LDPE) of pressure rating 6 kg/ sqcm fixed to wall or floor etc including fittings complete all as specified and as directed.
S&Fbrass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed.
S & F PVC connections 15 mm dia with PTMT Nuts of length for 450 mm Long complete all as specified and as directed.
S&F for steel ventilators with top hung shutters including hinges wih steel peg stay complete all as specified and as directed.
S & F 4.0mm thick figuered glass, pin head type and glazing with oil putty in squares n. exc 0.50 Sqm in each pane complete all as specified and as directed.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out of soft soil complete all as specified and as directed.
M&L for 60mm thick machine pressed precast concrete interlocking tiles any shape, size, colour/pattern (as approved) conforming to IS-15658-2006 of M-35 grade and of ISI marked complete all as specified and as directed.
M&L for 75mm thick cement concrete type D2 1:4:8 (40mm graded stone aggregate) as in subfloors, subbases, path and pavings etc complete all as specified
M&L for sand filling under interlocking tiles including watering and consolidating complete all as specified and as directed.
Demolition of PCC of any description in any position, not otherwise specifically provided for in foul condition complete all as specified and as directed.
Demolition of brick work built in cement mortor in foul condition complete all as specified and as directed.
M&L 150mm dia (internal) DWCPE (SN8) pipes as per IS-16098 (part-II) laid in trenches including all accessories & jointed complete all as specified and as directed.
M&L 200mm dia (internal) DWCPE (SN8) pipes as per IS-16098 (part-II) laid in trenches including all accessories & jointed complete all as specified and as directed.
M&L PCC 1:2:4 type B-1 using graded stone aggregate at manhole benching & coping complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 using graded crudhed/stone aggregate for foundation, filling and mass concrete complete all as specified and as directed.
Cutting in to existing manhaoles for connecting new drains, making good to pipe and rendering, cutting out existing benching for as specified dia of pipe 150mm complete all as specified and as directed.
M & L rendering 15 mm thick on brick work or concrete surface in CM (1:4) with water proofing compound (WPC to be measured & paid separately) and finishing the surface even and smooth with using. extra cement complete all as specified and as directed.
Supply only integral water proofing compound, ISI marked complete all as specified and as directed.
S & F SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) conforming to IS 12592 and sizes suitable for MH as per drg No BTD-806 & fixed with cement mortar 1:6 complete all as specified and as directed.
M & L for RCC M-30 Desgin Mix using 20mm graded crushed stone aggregate as in slabs supported on walls, beams & columns in roofs, balconies and in shelves and the like complete all as specified and as directed.
M & L for RCC M-30 Desgin Mix using 20mm graded crushed stone aggregate as foundation, footing and in static tank wall, retaining wall, basement wall complete all as specified and as directed.
Use and waste of formwork to faces of wall, retaining wall abutments, parapets and foundation footing base of colomns raft and raft footings complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick for rough finished surfaces complete all as specified and as directed.
Dismantling and disconnecting of existing CI soil vent pipe 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed.
Dismantling and disconnecting of existing CI soil vent pipe 75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed.
M & L for 100mm dia cast iron pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified and as directed.
M & L for 75mm dia cast iron pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified and as directed.
M & L 100mm bends of (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
M & L 75mm bends of (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
Add or deduct from Item No 97 here-in-before, for each 25mm girth or part thereof over or under 30cm
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing serviceable tiles to store and rubbish off the premises etc complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping,clean and washing down with water to remove dust,etc. complete all as specified and as directed.
M & L for 25 mm thick PCC type B-0, 1:2:4 (20mm graded aggregate) complete all as specified and as directed.
M&L, Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover cement screed bed laid over 15mm screed base in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Taking down Chowkhats or frames with shutters (without taking off from the frames)not exc. 1.5 sq. m each and removing from site complete all as specified and as directed.
Dismantling wall and ceiling board (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
Anodised aluminium snap grid frame work for false ceiling all as specified fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified amd directed
Refixing roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
S & F roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
M&L applying Two coat of oil bound distemper on New plastered surfaces of wall over a coat of primer incl preparation etc complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof covering etc complete all as specified and as directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F ceiling fans copper wound complete with three blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep min air delivery 210 CFM with service value 6.00 BEE. 5 star rated with brushless direct current motor (BLDC) complete all as specified amd directed
S 7 F for 3 core 1.5 Sqmm, PVC insulated round sheathed copper conductor cable for connection of ceiling fan from ceilling rose to fan complete all as specified amd directed
taking down or up GI tubing 15mm bore including cleaning for refixing etc. complete all as specified and directed
taking down or up GI tubing 20mm bore including cleaning for refixing etc. complete all as specified and directed
Refixing 15mm bore old steel tubing and connections in new or old position (wall, ceiling, floor etc) complete all as specified and directed
Refixing 20 mm bore old steel tubing and connections in new or old position (wall, ceiling, floor etc) complete all as specified and directed
S & F GI tubing 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed
S & F GI tubing 20mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed
Disconnecting existing tanks, 1000 ltr setting a side (or lowering if required) for repairs, cleaning etc and hoisting if required reconnection and re-fixing in position (cleaning repairing, etc. Easured separately) including cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes, etc complete all as specified and directed
Dismantling water tank of any size and removing complete all as specified and directed
S & F PVC water tank 1000 Ltrs including 20mm bore PTMT flot valve complete all as specified and directed
S & F Draining board of 1 st class hardwood, 25mm thick, as described in SSR Part-I section 8 Clause 8.30 9area of top of board only to be measured) including fixing with bolt to MS tank stagging etc complete all as specified and directed
M & L for preparing steel surface over 10cm width or grith and applying two coat synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
S & F framed work as in tank plateform of angle channel or other section etc complete drilled for fastening with existing tank plateform to increse height of plateform including cutting of existing plateform and fixing complete Fe-290 (Gde E-165) complete all as specified and directed
M & L for point wiring for one light / fan point controlled by one switch with 4 Sqmm PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including PVC conduit 20mm dia heavy duty ISI conduit accessories, PVC gang box for mounting switches/sockets for 15 Amps power point including PVC insulated unsheathed 4 Sqmm copper conductor cable FR-LSH for earth wire connected to common earth dolly complete all as specified and directed . (Note:- Switches, sockets etc shall be measured and paid for separately under respective items of schedule.)
S & F switch piano, flush type single pole, one way 15Amp complete all as specified and directed
S & F Socket outlet 2 in 1, 3 pin, 5/15A combined complete all as specified and directed
S & F MCB SP 5-32 Amp 10KA 'C' series complete all as specified and directed
S & F stoage type water heater (Geyser) electrical operated 230/240 volts 25 ltr capacity, BEE 5 star complete with all safety equipment and accessories such as safety value, thermostat, plug top, etc. required for proper functionaly & including electric/earth connections and carrying out grounting 7 conplete installations with mounting bolts, nuts including testing after installation complete all as specified and directed
S & F bib taps 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed
S & F Pillar taps 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without ettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed
S & F PVC connections 15mm size with PTMT nuts of length 300mm suitable for hot and cold water complete all as specified and directed
M & L for Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified and directed
One Socket outlet three pin, 6 Amp, on the same board, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and directed
One Socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and directed
Note for serial item No 13.00 to 13.06: 1. Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. 2. GI boxes shall be fixed flush in position with cement mortar (1:4) complete all as directed.
S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified and directed
S&F Switch modular type single pole one way, 16 Amp, one module, complete all as specified and directed
S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6 Amp, two module, shutter type complete all as specified and directed
S&F Socket outlet modular type multipurpose 3 pin, 2 in 1 single pole one way 6/16 Amp, two module, shutter type complete all as specified and directed
S & F Ceiling rose, 3 phase / PVC / polycarbonate, isolated body complete all as specified and directed
S&F in replacement sheet metal encloser double door 8 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
S & F MCB 6-32 Amp SP 10 KA 'B' series complete all as specified and directed
S&F RCBO for EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION 415 V 40-63A AC type 10kA Four pole 30mA ISI marked complete all as specified and directed
S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, 1.2 m 3000/6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver complete complete including making connection complete all as specified and directed.
S & F wall mounted LED batten fitting 1x10 watt, 6500K, 2 ft complete with decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviroment friendly, energy efficient complete with all light fittings connection complete all as specified and directed.
S&F angle lamp PVC/polycarbonate type with back plate complete all as specified
S&F LED 7W lamp(base B-22) complete all as specified and directed.
S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 & IK 08 protection including fixing with suitable bolt and nuts complete with making connection complete all as specified and directed.
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable. Note:- It is mandatory to paint a sqaure shape notice board of yellow color with legible black color letters of earthing mentioned details as below; Cost incurred deemed to be inlcuded in quoted rate:- (i) CA No. (ii) Date of installation after initial testing & Value of earth resistance in Ohm (iii) Date of last testing (iv) Value of earth resistance in Ohm in last test
S & F Heavy duty plastic body ventilation fan of 250mm sweep, 240 volt, having RPM not less than 1200, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including grouting of bolts and making good to distubed wall complete all as specified and directed.
S & F 1100volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing odf PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular of size 10.0 sqmm including 01x house service brackets made up of 40mm dia medium grade GI pipe bent at 90 digree angle of length not more than 3.0m complete all as specified and directed.
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
M/s Manav Builders
LM CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .