Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 CrAccepted-AOC 1095 ELDECO 2 UPHAAR SECTOR 3 RAIBAREILLY ROAD LUCKNOW UP PIN 226002 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | ₹21.9 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹228.7 CrRejected-Finance | ₹228.7 Cr | L2 | Rejected-Finance being other than L1 |
Tender Value
₹22.9 Cr
EMD Value
₹14.7 L
Closing Date
9 Nov 2024, 6:00 pmClosed
Chief Enginner Lucknow Zone , Lucknow
Headquarter Chief Engineer Lucknow Zone, 17 Carriappa Marg Post Dilkusha, Lucknow Cantt PIN -226002
PROVISION OF OTM ACCN PH II OF II PHASES AT NEW CANTT PRAYAGRAJ
2024_MES_653962_2
CELZ/PRJ/T-06 OF 2024-25
Open Tender
Civil Works
540 days
Prayagraj
AS per NIT
8 documents required · 8 mandatory
₹3,000
GE(West) Prayagraj
₹14.7 L
28 Dec 2024
10 Sept 2024
16 Nov 2024
10 Sept 2024
9 Nov 2024
26 Oct 2024
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road, Path & Culvert)
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Sewage Disposal)
Total amount of Sch 'A' Part VIII (Compound, Wall, Fencing & Gate)
Total amount of Sch 'A' Part IX (External Water Supply )
Total amount of Sch 'A' Part X (Package Type Mechanical Laundry )
Total amount of Sch 'A' Part XI (External Electrification)
Total amount of Sch 'A' Part XII (Solar Water Heater)
Total amount of Sch 'A' Part XIII (Lighting Protection)
Sch 'A' Part - XIV (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
Internal Water Supply S&F Angle valves ,15mm, cast copper alloy, fancy type, CP, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for union and fixed. complete all as specified and directed.
S&F Bib taps 15mm,cast copper alloy, fancy type, CP long body with flanged screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F Pillar tap 15mm,ISI marked,cast copper alloy, fancy type, chromium plated,quarter turn screwed down high pressure,with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed.
S&F Concussive Push button taps 15mm,cast copper alloy, fancy type, chromium plated,screwed for iron pipe and fixed complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-(i) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only. (ii) Modular (switch, Socket,metal box, cover plate ) items measured and paid separately.
M&L for Point wiring complete for One light point controlled by two way switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-(i) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only. (ii) Modular (switch, Socket,metal box, cover plate ) items measured and paid separately.
M&L for Point wiring complete for 5 Amp independent board with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-(i) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only. (ii) Modular (switch, Socket,metal box, cover plate ) items measured and paid separately.
M&L for Point wiring complete for 5 Amp socket point on the same board controlled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-(i) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only. (ii) Modular (switch, Socket,metal box, cover plate ) items measured and paid separately.
M&L for power point wiring complete for one 15 Amps switch socket outlet point on independents board with PVC insulated and unsheathed, FRLSH cable 2.50 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and PVC conduit in roof/floor slab, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of required colour complete, including 2.50 Sqmm, FRLSH cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. Note :-(i) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only. (ii) Modular (switch, Socket,metal box, cover plate ) items measured and paid separately.
Supply and fixing Modular Metal Flush Box for 8 Module ,complete all as specified and dierected.
Supply and fixing Modular Metal Flush Box for 10 Module ,complete all as specified and dierected.
Supply and fixing Modular White cover plate with frame for 10 Module, complete all as specified and dierected.
S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.complete all as specified and directed
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.complete all as specified and directed.
S&F LED Building security light fitting 25 Watt with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (24W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
Supply and fixing LED Luminaire 600 mm x 600 mm 34/36 watts 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof/ ceiling/surface mounting type including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specifed and directed.
S&F LED Lamp 10/14 Watt retrofit type complete all as specified and directed by Engr-in-charge
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class insulation B, 3 Nos blades, 30/40 Cm long down rod, 2 no canopy, shackle kit, safety rope, copper winding, power factor not less than 0.90 services value (CMM/W) minimum 6.0 Air delivery min 210 CMM, 350 RPM (tolerance as per IS: 3742019) THD less than 10 % without remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nuts, bolts, washers, suitable for 230 V, 50 Hz single phase AC supply earthing etc and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed. Note:- (a) T&P will be provided by the contractor for reaching any height of the building/warehouse/Hanger
S&F MCCB 4 pole ,415 V ,AC fixed type 125 amps with breaking capacity 16 KA complete all as specified and directed.
S&F VTPN DB 4 way double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete without MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed by Engr in charge.
Supply and fixing Tele phone socket ,Modular, ISI marked complete all as specifed and directed.
S&F TV Socket modular type complete with ISI marked complete all as specified and directed .
M&L Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing wire beyond 7.5m shall be measured and paid separately.
S&F Air circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting complete all as specified and directed.
S&F LED high bay light of 100 Watts, electrical insulation class I, color temp 6000 K, IP-65, as per IEC standard complete all as specified and directed .
ROAD, PATH & CULVERT Provision for RCC culvert of 6.00 mtr long and clear width 450 mm and on required minimum depth & including excavation , parapet & two coats of colour wash over a coat of white wash complete all as specified and directed.
Provision for RCC culvert of 9.00 mtr long and clear width 450 mm and on required minimum depth & including excavation , parapet & two coats of colour wash over a coat of white wash complete all as specified and directed.
Provision for RCC culvert of 9.00 mtr long and clear width 600 mm and on required minimum depth & including excavation , parapet & two coats of colour wash over a coat of white wash complete all as specified and directed.
EXTERNAL WATER SUPPLY Construction of fly ash brick masonry valve pit chamber of size 1020 mm X 1020 mm X 1020 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 950mm X 950mm X 950mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 450 mm X 450 mm X 450 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Supply, laying, testing and commissioning Ductile Iron pipe, single socket 150 mm bore including Rubber gasket joints, Class K-9 in any length laid in trenches complete all as specified and directed.
Supply, laying, testing and commissioning Ductile Iron pipe, single socket 100 mm bore including Rubber gasket joints, Class K-9 in any length laid in trenches complete all as specified and directed.
Supply & Fixing cast iron Air release valve with two air outlets 150mm dia bore and fixing up in cast iron water supply mains complete all as specified and directed.
Cutting/threading of existing CI / DI 150 mm water main and insertion of Tee of existing size fittings / long and making leak proof joint for fresh connection complete all as specified and directed.
Cutting Road/PCC path, hardstanding depth not less than 60cm and width not less than 45cm for laying water supply pipe and making good the existing surface with PCC (1:2:4) type B-2 using 40mm graded stone aggregate of 150mm thick complete all as specified and directed.
BOREWELL Trial bore well of 250mm dia size pilot bore upto 180 mtr depth through any soil strata including hard stone/boulder by means of direct rotary method below ground level complete all as specified and directed by engr-in -charge.
Drilling reaming vertical bore 500mm to 610 mm dia at approved site/ location in any type of strata for 250 ERW casing pipe for various depth as shown below including all works pertaining to boring complete in all respects as specified and directd.
Supply and assembling including jointing, lowering and fixing in position ERW plain steel pipe (seamless) housing pipe 250 mm bore (nominal dia ) 8 mm thick and outer dia of pipe 322 mm conforming to IS-4270 class 8.1.1 plain end pipe jointed and welded coupler ring (welding shall be done throughout circumference of the pipe and coupler ring both sides all as specified and directed. NOTE - (a)Length of pipe shall not less than 2.40 mtr except where the pipe length required is less than 2.40 mtr (b) Effective length shall only be measured and paid.
All as item no 14.39 here-in-before but supply assembling jointing ERW plain steel pipe (seamless) casing 200 mm bore 8 mm thick and outer dia of pipe conforming to IS-4270 complete and lowering and fixing position after socket reducer of 250x150 mm bore complete all as specified and directed .
S&F MS strainer (slotted) pipe V wired 150 mm bore 8 mm thick conforming to IS-8110-2000 fabricated with pipe slote of size 1.55 mmx75 mm as per IS provision uniformly distributed on the surface complete all as specified and directed by engr-in -charger.
Supply and fix Mild Steel reducing socket 250 mm x 150 mm dia of suitable length including welding mild steel strip 40x6 mm 2 Nos on each joint extended in 75mm on each side complete all as specified and directed NOTE -The wall thickness of socket shall not be less than 7 mm thick
S&F wrought iron bail plug 150 mm bore complete all as specified and directed.
S&F well cap for 250 mm dia housing pipe complete all as specified and directed.
S&F centring guide made out of 50x6 mm MS flat iron on liner assembly complete all as specified and directed .
S&F 2 Nos MS flat iron 250 mmx15 mm housing clamp for holding to 250 mm dia housing pipe with 16 mm MS bolt& washers including casting of PCC block 1:2:4 type B-1( using 20 mm graded stone aggregate) of size 1.20 mx1.00 m including 50 mm dia MS pipe 2 nos each 1.5 m long with cap plug and cap top for filling pea gravel including necessary excavation & each work in any type of soil complete all as specified and directed.
M&Lfor packing pea gravel of size 3 to 5 mm natural shape brought direct form river ban and packing around casing pipe to entire depth up to ground level cpmplete all as specifed and directed Note- Length of assembly packed only will be measured for payment
M&Lfor development of tube well by means for over pumping high velocity fitting with 600 PSI air compressor all as specified in IS-8110-2000 para 4.3 including arrangement for equipment fitting and supply of sodium hepta sulphate 60 KG complete all as specified and directed
All as per SI item No 14.48 here-in-before but by means of over pumping for subsequent hours untill clear discharge as per clause 9.3 of IS 2800 (part-I) 2009 complete all as specified
Supply only strata sample box with glass cover 3mm thick and having internal dimension 1.0 mtr x 0.60 mtr x 0.10 mtr made out of shisham plank 20 mm thick with hinges, hasp and staples including polishing complete with samples at various depth met at the time of boring including strata chart in duplicatecoplete all as specified and directed.
Chemical bilogical and potability testing of water sample taken from the bore at Govt approved laboratories. Complete all as specifed and directed Note:- test Certificate obtained from approved lab will submitted by the contractor in orginal.
Yield testing for borewell by continuously pumping for 16 hours to determine safe pumping yield of the tube well complete all as specified and directed.
Electric logging in trail bore perecise delineation of granular zones and also the quility of ground water including report interpretation complete all as specifed and directed Note; (a) Electric logging shall be carried out by approved agency. (b) Unit rate quoted by tenderer shall be deemed to be inclusive of cost of MS pipe and transportation of ring accessories as required, developing and testing etc at site of work and removal of the same on completion from the site including necessary supervision and rental charges of rig machine compressor & OP unit ( any other T&P not specifically mentioned ) and no extra payment shall be admissible on this account
S&F H Frame as suitable for submersible pump and motor to connecte column pipe of rising main flanged and column pipe or submiersible pump set complete with nut bolt washer etc including grouting four bolts on PCC platforms complete all as specified and directed Note: PCC Plate form will be measured and paid seperately
Supply loweing jointing and testing MS black column pipe 3 mtr longh heavy duty 100 mm bore wall thickness 5.4mm both ends flanged with heavy duty MS fanged not less than 16mm screwed and welded in side and outside. The flanged end making surface shall be smooth including welding of 04 strip of 5.04mm thick 25mm wide and 50mm long covering pipe and flanged both end flanged having 08 Nos predrilled hole not less than 16mm including runbber gasket nut bolts and washers, pipe should be duly painted with anti corrosive paint complete all as specified and directed
S&F in replacement of PVC insulated flat copper submersible cable heavy duty 3 core 16 sqmm 1100 Volt grade complete all as specified and directed
S&F submersible pump with electric driven motors of suitable capacity as per design 3 Phasae 415 Volt with head 60.00 M to 120 Mtr and dicharge 1000 LPM to 1500 LPM complete instalation and making electrical connection and testing complete to entire satisfaction of Enginer in charge
Cutting jointing and making connection with 150mm dia CI existing pipe line with all fitting and making connection leak roof
S&F High pressure single head chemical dosing system. power input 230V, 50Hz, 40 SPM, 1/30 fractional horse power, pressure 5kg/sqcm, max output 6.5 ltr with accessories like lead tubing, connecting ferrule, check valve : preparation tank model AQUA1005 of net capacity 170 ltrs FRP dosing tank dia 650 x net height 375+ conical 300 mm, gross height with standrad 1000mm consisting of water inlet line, outlet strainer, drain, overflow, conical bottom of sludge deposition, pot hole with cover,Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller complete.
(i) MCCB 4, pole 25 kA with adjustable thermal setting, 415V, 160 Amp - 01 No. (ii) MCCB 4, pole 25 kA with adjustable thermal setting, 415V, 100 Amp - 01 No (iii) Star delta starter comprising suitale size of 3 pole contactors upto 40-60 HP submersible pump with thermal over load relay complete - 01 No (iv) Motor protection relay for single phase, over load, over voltage (v) Digital Volt meter 0-500 volts (vi) Ammeter 0-500 amps with suitable size of Cts (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set (ix) MCB' TP 32 Amps 10 KA - 01 No (X) MCB SPN 32 Amps 10 KA - 01 No (xi) Single phase preventer - 01 No
PACKAGE TYPE MECHANICAL LOUNDARY Supply and install testing commissioning washing Extractor with a built hydro extractor of capacity 25-30 Kg(Per charge) of minimum size of basket 305x840x550 mm front loading & unloading , High speed extraction , Fully suspended soft mount type, electricity heated/operated with motor capacity minimum 7.5 HP and operated stainless steel body controlled through programmable logic control(PLC) with LCD display showing complete informaton of programme, pause and continue features are provided in case of power outage, auto time reverse, auto sto, auto temp control, auto level control pneumatically operated valves for auto waterinlet, auto steam inlet, auto drain valve frequency drive for variable speed, inner basket and outer body stainless steel , Heavy duty MS fabricated structure safty features as both mannal and auto door lock mechanisms ensure the stays closed during operation, emergency stop switch all as specified and directed.
Drying thumbler electrically heated and operated having front loding open pocket type, auto cool down after activities of the drying, auto time, auto stop, auto reverse with fully die pressure door, inner basket stainless steel, outer drum double walled insulated with glass wool of capacity 25-30 kg per charge all as specified and directed.
Supply & fix Vaccum Ironing table of Size 130x80 cms with 2128 press Model No RV 4425-80 or equivalent all as specified and directed
Supply & fix Electrical Boiler of 02 Table capacity, Model No MR 06 or equivalent all as specified and directed.
LIGHTENING PROTECTION M&L for Earthing complete with copper plate 600 x 600 x 3.15 mm thick electrode and 20x3 mm copper strip as earthing lead thick, burried directly in ground ( earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected withcopper strip 20 x 3mm thick by means of bolts, nuts, check nutsa and excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B1 using (20 mm graded stone aggregate ) with cover with handle, watering arrengement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and comman salt complete all as shown in electrical plat no. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note:- If the desired earth resistance is not found, eathing shall be redone by the contractor at no extra coast to the department .
DG SETS Supply ,installation, commissioning & testing Silent/containerzed diesel engine driven generating set outdoor type and as per Emission norms CPCB IV + complete to give an output of minimum 57 KVA AC 415 Volts, 50 Cycles per second, 3 phase 4 wire supply with power factor 0.8, 1500 RPM diesel engine and alternator mounted on common base plate, anti vibration rubber mounting pad (AVM Pads "B" series) complete in all respect with and including accessories and components as specified below including sound proof integral accoustic enclosure for 57KVA Gen Sets ECO friendly and as per Ministry of Environment, forests notifaction 17 May 2002 complete including, emergency stop button, illumination inside canopy, Temperature sensor for high temp safety, exhaust fan etc complete as per IS 4722, AMF type with relay panel for automatic starting on mains failure.
(a) Diesel Driven Engine (Prime mover):- Multi cylinder, vertical/horizontal, 4 stroke cycle, suitable for 57 KVA alternator, water cooled conforming to BSS- 649 rated for continuous running diesel engine suitable to FF matching BHP at 1500 RPM as per latest ISS/BSS, capable of taking 10% over load for any one hour in any 12 hour running, complete with and including following accessories:- i) Fuel filter ii) Governor ( Electronic) iii) Complete battery set with lead & lugs as recommended by manufacturer. iv) Lubricant oil cooler v) Lubricant oil pump. vi) Lubricant oil filter vii)Digital oil pressure gauge viii) Any other parts as prescribed by manufacturer for its good functional performance. ix) Battery charging alternator suitable for charging Batteries. x) Dry type air filter xi) MS channel fabricated frame rigidly welded suitable for receiving the diesel engine and alternator and anti vibration pads. xii) Coupling guard. xiii) Exhaust pipe fully extended to exhaust gases outside the acoustic enclosure including silencer and necessary insulation lagging all as per manufacturer's recommendations. xiv) Fuel tank of MS sheet and of capacity for 12 hours running on full load with inlet and outlet connection, filling cap, drain valve, air vent with caliberated scale on outer surface, floor mounted with suitable angle iron supports. xv) Digital type RPM meter with hour meter. xvi)Self starter of suitable size xvii) Turbo chargerxviii) In line mono block xix)Fuel pump xx)Digital type Coolant temp gauge. xxi)Self starter with auto electric start accessories xxii) Engine safety low lubricant oil pressure and high coolant temperature. xxii) Test certificate
(e) Supply & install of Acoustic Enclosure suitable for 57 KVA DG set as under i) Fabricated out of CRCA sheet of suitable thickness as per manufacture design. Polyster based powder coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated. ii)The doors are gasketed with EPDM gaskets.iii) Sound proofing with high quality rock wool/ mineral wool confirming to IS 8183 of 50mm thickness and density at 96 Kg/M3 covered with fiber glass cloth and perforated powder coated sheet specialy designed allenuators (Sound controller) at air entry and exit of the container noice level shall be not exceed 75 Db at 1 meter distance as per CPCB/Government of India Norms. iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. v) Emergency stop push button outside the container. vi) Provn of light inside the canopy i.e. providing LED light fitting 1 x10 Watt with wiring and control switch. (f) MOUNTING ARRANGEMENT- Prime mover and alternator shall be mounted on skid mounting type base frame fabricated from ISMC channel or in sheet metal providing common bed for engine and alternator directly coupled together the base frame has provision for grouting on foundation bolt as well as fixing on vibration mounts provision is made in base frame for tilting arrangement of DG set as recommended by manufacturer. The base frame shall have provision of lifting hook for convenient lifting of complete set ie along the canopy engine and alternator. (g) cost of construction of PCC foundation and RCC plinth top side of DG Set as per manufuacture design and recommendation deemed to be included in this item.
REFRIGERATION& AIR CONDITIONING Supply and install Supply, installation,commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz 320 litre capacity having single door complete all as specified and directed..
Supply and installation of Water Cooler of capacity 80 litre storage and nominal cooling capacity 40 litre per hour, connecting to GI tubing by means of and incuding PVC pipe connection with brass coupling, nuts at both ends and PVC pipe flexible of suitable size for waste water an dother necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stablizer to water cooler complete all as specified and directed. Notes:- (i) GI pipe line will be measured and paid separately
Supply and installation of Dessert cooler electric fan driven (Single phase) having normal air flow capacity of 5000 Cum/ hour complete with exhaust fan motor 450 mm sweep RPM and submerisble water lifting pump of capcity 2.80 m head 230 Volt AC including locally fabricated cabinet with three side panels front top and tank including vertical mention made out of 22 SWG PGI sheet of size not more than 121.1 x 76.5 x 55.5 cm with front side chequerd mess, including 4 way PVC distributer, PVC pipe 3 to 4 mtr for spray water, wood wool pads, plastic electrical box having two Nos 5 amps piano switch and indicator including suitable size stand for outdoor mounting of dessert cooler complete with electric wiring for fan & pumps controlled separately all as specified and directed.
S&F Voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output viltage stabilized at 230 V with accuracy ± 2.5% and of capacity 1.0 KVA (for Deep Freezer & Water cooler)
All as per Item No-24 here-in-before but of capacity 4.0 KVA (for AC 1.5/2 Ton)
Supply and install hi wall split AC units 1.5 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity as shown complete with all as specified and directed.
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts.
EXTERNAL ELECTRIFICATION Supply installation, commissioning and testing of transformer copper wound step down 400 KVA outdoor type 11/0.433 KV at no load 3 ph, 4 wire 50 Hz 433 Volts AC with Onan cooled oil immersed copper wounded outdoor type, delta connected on HV side and star connected in LV side in accordance with vector symbol DY-II with neutral brought out on secondary side and having tapping in step + 2.50 % (-) (+) 7.5% to be changed by mean of hand operated OFF load tap changing gear including first fill of transformer oil as per IS 335 and including all fitting accessories as specified in SSR part-I and as per revised (fourth revision) Amendment No -04 Mar 2021 IS-1180, part-I 2014 (level 2) , Energy efficiency level -2 and losses as per IS -1180 Part -I 2014, Revised Amendment No -04 Mar 2021.transformer should have cable end terminal box on LV and HV side, oil temprature gauge, dehydrating breather with first fill of dehydrating agent, oil conservator tank, explosive vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthing terminal for neutral and body complete with all other standard accessories etc as specified and PCC foundation as per manufauture drawing of transformer all as specified and directed. The transformer shall be complete with the following fittings and accessories:-
Oil conservator tank with filling holes and cap filter type drain valve and oil level gauge- 01 Nos
Silica gel breather with connecting pipe and first fill of dehydrating agent- 01 Nos
Air Release valve plug- 01 Nos
01 No 100mm dia type thermometer vapour pressure type having rating 0-120 degree centigrate with max temp indicator and resetting device incl max reading pointer washers- 01 Nos
Thermometer pocket on tank cover
04 Nos plain solid CI detachable rollers
02 Nos Earthing terminals on tank cover to facilitate GI Earth Strip
Rating plate and terminal marking plate
Two no GI Tubing light grade100 mm dia 60 cm long embedded in brick/wall on LT/HT side for drawing UG Cable
First filling of oil confirming to IS-335 and tested upto 50KV/2.5mm dielectric strength
Lifting lugs/hook
Oil drain valve with plug
Cable end termination boxes on HV and LV sides
Explosive Vent
Name, Rating, Diagram plate- 01 Nos
Off circuit tap changing switch- 01 Nos
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32x6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B-1 using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply and fix LED street 70 W IP 66 230 V AC outdoor type are aerodynamically designed with high pressure die cast alluminum housing and heat resistant complete with driver incl bracket of 32 mm dia light grade GI tubing 1.2 m long bend to shape with suitable size nut bolt & washer etc including making cable connection with 3 core PVC insulated copper conductor cable of 1.5 sqmm all as specified and directed.
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 nos of single pole MCBs 6-32 amps,10KA inside the box and all as spcd and directed.
Supply and fix of automatic street Light switch using digital timer switch for automatic switching of street light Panel of following Configration as under-Single phase, Max Load 6 kw, digital timer, Contractor-32 Amps TP, MCB Rating- 40 Amp SPN complete should be enclosed in pole/wall/floor mountable enclosure made of rust proof electric shock proof, Termite proof and FR grade SMC box/CRCA sheet 2mm thick confirming to IP 54,with necessary PCC(1:2:4) all as specified and directed .
Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.15 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and mounting measuring instrument such as Volt meter, Ammeter,CT's, Phase indicator lamps including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed by the Engg-in-charge
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-55, 11.00 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 9.00 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and fixing Terrain post top lantern is a weather proof indirect lighting solution LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp and including necessary items for GI pipe etc for fixing of fitting complete all as specified and directed.
BD AGARWAL BUILDTECH INDIA PRIVATE LIMITED (BID ID -3155879)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid