| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC C O MR M K BHOWMIK NEAR TAPAN VARIETIES JOYNAGAR 06 AGARTALA TRIPURA W 799001 | WEST TRIPURA | TRIPURA | 799001 | ₹8.5 L Quoted ₹8.7 L | L1 | Accepted-AOC SUCCESSFUL BIDDER |
| 2 | L2₹9.5 LRejected-Finance | ₹9.5 L | L2 | Rejected-Finance REJECTED NOT BEING L2 BIDDER |
| Sl No | Description | Qty | Unit | SHRI SUBRATA GUHA L1 | M/S NIYATI NETWORK L2 |
|---|---|---|---|---|---|
| 1.00 | Disconnecting electrical connection and taking down/removing unserviceable window type Air conditioner 1.5 or 2.0 Ton capacity of any make and transporting same to MES Yard for annual repair/ servicing / cleaning / maintenance. Dismantling the Air conditioner segregating unserviceable/wornout parts, carryout repair including replacement of worn out parts, section and reaching line including insulation of copper pipe line UNSV caliform dismantling and required new fixing, reassembling all components and transporting the same upto its original location, fittings/fixing and making electrical connection including testing for effective cooling all specified and directed. (Note : New spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of AC are deemed to be included in the quoted rate) | 2 | Each JOB | 1,175 ₹2,350 | 1,150 ₹2,300 |
| 2.00 | Disconnecting electrical connection and taking down/removing unserviceable Split type Air conditioner 1.5 or 2.0 Ton capacity of any make and transporting same to MES Yard for annual repair/ servicing / cleaning / maintenance. Dismantling the Air conditioner segregating unserviceable/wornout parts, carryout repair including replacement of worn out parts, section and reaching line including insulation of copper pipe line UNSV caliform dismantling and required new fixing, reassembling all components and transporting the same upto its original location, fittings/fixing and making electrical connection including testing for effective cooling all specified and directed. (Note : New spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of AC are deemed to be included in the quoted rate) | 12 | Each JOB | 1,528 ₹18,336 | 1,600 ₹19,200 |
| 3.00 | Supply only new starting capacitor of capacity 80/100 mfd suitable for operating voltage 240 volt, 50 HZ all as specified and directed. | 12 | Each | 733 ₹8,796 | 750 ₹9,000 |
| 4.00 | Supply only capacitor 6 mfd of blower motor suitable for operating voltage 240 volt, 50 HZ all as specified and directed. | 12 | Each | 392 ₹4,704 | 400 ₹4,800 |
| 5.00 | Supply only new running capacitor of 36 to 45 mfd suitable for operating voltage 240 Volt, 50 HZ all as specified and directed. | 12 | Each | 822 ₹9,864 | 800 ₹9,600 |
| 6.00 | Supply only new thermostat suitable for any type and make of window Air conditioner 1.5/2 ton capacity all as specified and directed. | 2 | Each | 1,095 ₹2,190 | 1,200 ₹2,400 |
| 7.00 | Supply only new blower motor 0.5 to 1 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of window air conditioner of 1.5/2 ton capacity all as specified and directed. | 3 | Each | 4,437 ₹13,311 | 4,500 ₹13,500 |
| 8.00 | Supply only new blower motor 0.5 to 1 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of Split type air conditioner of 1.5/2 ton capacity all as specified and directed. | 10 | Each | 4,437 ₹44,370 | 4,500 ₹45,000 |
| 9.00 | Supply only new swing motor complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of window air conditioner of 1.5/2 Ton capacity all as specified and directed. | 2 | Each | 666 ₹1,332 | 500 ₹1,000 |
| 10.00 | Supply only new swing motor complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of Split type air conditioner of 1.5/2 Ton capacity all as specified and directed. | 10 | Each | 638 ₹6,380 | 600 ₹6,000 |
Updated dates
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
9 Apr 2026, 6:00 pmClosed
AGE (I) Agartala
AGE (I) AGARTALA PIN-901184 C/O 99 APO
REPAIR REPLACEMENT AND MAINT OF COOLING APPLIANCES INCL REPLACEMENT OF WORN OUT ACCESSORIES OF WINDOW TYPE, SPLIT TYPE AIR CONDITIONER, WATER COOLER, REFRIGERATOR, DEEP FREEZER AND VOLTAGE STABILIZER AT MIL STN AGARTALA
2026_MES_756104_1
8868/E8
Open Tender
Electrical and Maintenance Works
180 days
AGARTALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Agartala
₹17,000
Yes
16 May 2026
12 Mar 2026
11 Apr 2026
12 Mar 2026
9 Apr 2026
26 Mar 2026
Supply only new starting capacitor of capacity 80/100 mfd suitable for operating voltage 240 volt, 50 HZ all as specified and directed.
Supply only capacitor 6 mfd of blower motor suitable for operating voltage 240 volt, 50 HZ all as specified and directed.
Supply only new running capacitor of 36 to 45 mfd suitable for operating voltage 240 Volt, 50 HZ all as specified and directed.
Supply only new thermostat suitable for any type and make of window Air conditioner 1.5/2 ton capacity all as specified and directed.
Supply only new blower motor 0.5 to 1 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of window air conditioner of 1.5/2 ton capacity all as specified and directed.
Supply only new blower motor 0.5 to 1 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of Split type air conditioner of 1.5/2 ton capacity all as specified and directed.
Supply only new swing motor complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of window air conditioner of 1.5/2 Ton capacity all as specified and directed.
Supply only new swing motor complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of Split type air conditioner of 1.5/2 Ton capacity all as specified and directed.
Supply only new starting relay 3 or 4 terminal with connecting leads suitable for any type and make of window air/ split type air conditioner of 1.5 Ton/2 Ton capacity all as specified and directed.
Supply only new sealed compressor suitable for 1.5 Ton split type air conditioner having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed.
Supply only new sealed compressor suitable for 2.0 Ton split type air conditioner having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-22/R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed.
Supply only new sealed compressor suitable for 1.5 Ton window type air conditioner having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-22/R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed.
Supply only Indoor AC display unit complete all as specified and directed
Supply only Indoor AC cooling condenser unit complete all as specified and directed
Supply only Indoor AC blower fan bush complete all as specified and directed
Supply only AC remote window/ split type complete all as specified.
Taking out unserviciable Split type air conditioner 1.5 ton of any type and make after opening the electrical connections, preparing the compressor for refilling and recharging the compressor and M&L for refilling the compressor oil in adequate quantity and recharging the R-134A gas in adequate quantity to acheive effective cooling and refixing the complete component of A/C including refixing the window A/C at its location and testing for effective cooling all as specified and directed.
Taking out unserviciable Split type air conditioner 2.0 ton of any type and make after opening the electrical connections, preparing the compressor for refilling and recharging the compressor and M&L for refilling the compressor oil in adequate quantity and recharging the R-134A gas in adequate quantity to acheive effective cooling and refixing the complete component of A/C including refixing the window A/C at its location and testing for effective cooling in all as specified and directed.
Taking out unserviciable window type air conditioner 1.5 ton of any type and make after opening the electrical connections, preparing the compressor for refilling and recharging the compressor and M&L for refilling the compressor oil in adequate quantity and recharging the R-134A gas in adequate quantity to acheive effective cooling and refixing the complete component of A/C including refixing the window A/C at its location and testing for effective cooling in all as specified and directed.
Supply only PVC insulated, sheathed flexible multi stranded copper conductor 1100 Volt, 3 core cable of size 40/0.0076 for electrical connection of window A/C, voltage stabilizer and charging sets all as specified and directed.
Material & Labour for rewinding of blower fan motor of window type of AC 1.5 TR capacity with proper gauge super enameled copper wire not less than 300 gm/unit including testing etc all as specified and directed.
Material & Labour for rewinding of blower fan motor of split type of AC 1.5/2 TR capacity with proper gauge super enameled copper wire not less than 300 gm/unit including testing etc all as specified and directed.
Supply only electronic (PCB) for circuit plate suitable for window/Split type AC 1.5/2 ton capacity.
Scrubbing down of old paint from 1.5/2 ton capacity window type /Split type AC with emery paper, cleaning, washing, filling cavities, welding, soldering, denting etc and M&L for spray painting to AC unit with two coats of synthetic enamel white paint and after drying writing MES No complete all as specified and directed.
Supply only cut off Relay for any type of make voltage stablizer 4/5 KVA of any type and make.
Supply only electronic (PCB) for circuit plate for voltage stablizer 4 KVA or 5 KVA capacity of any make and type.
Supply only volt meter for voltage stabilzer 0.5KVA capacity of any make and type.
Supply only control transformer for voltage stablizer 4 KVA or 5 KVA capacity of any make and type.
Supply only new sealed compressor suitable for following capacity of refrigerator having operating voltage 200 to 240 volts, 50 HZ, duly filled compressor oil and M&L for charging of R-134A gas in adequate quantity so that during testing effective cooling can be achieved including making all connections and all as specified and directed.
(a) 280 Ltrs Capacity
(b) 290/300 Ltrs capacity
Supply only new starting relay 3 or 4 terminal with connecting leads suitable for any type and make of refrigerator 300/280 ltrs capacity all as specified and directed.
Supply only new thermostat suitable for any type and make of refrigerator 300/280 ltrs capacity all as specified and directed.
Supply only new OLP for any type and make of refrigerator 300/280 ltrs capacity all as specified and directed.
Supply only new condensing unit suitable for refrigerator of 300/280 ltrs capacity all as specified and directed.
Supply only bio matel timer suitable for refrigiration 280/300 ltr capacity.
Supply only frost free fan motor suitable for double door refrigiration 280/300 ltr capacity.
Taking out Refrigerator any type and make after opening the electrical connections, preparing the compressor for refilling and recharging the compressor and M&L for refilling the compressor oil in adequate quantity and recharging the R-134A gas in adequate quantity to acheive effective cooling and refixing the complete component of Refrigerator and testing for effective cooling in all as specified and directed.
Supply only new sealed compressor for water cooler of 120/60 ltrs capacity with filling of compressor oil and charging of R-134A gas including testing for effective cooling of water
Supply only new sealed compressor for water cooler of 80/40 ltrs capacity with filling of compressor oil and charging of R-134A gas including testing for effective cooling of water.
Supply only new blower fan motor including fan blade assembly complete in all respect, 240 volt, 50 HZ for any type and make of water cooler having 80/40 ltrs capacity.
Supply only new OLP for water cooler for any type and make of water cooler 80/40 ltr capacity
Supply only new starting relay for any type and make of water cooler 80/40 ltr capacity .
Supply only new hose pipe (of dia not less than inlet/outlet pipe) including clamps, check nuts complete all as specified and directed.
Supply only new float valve having brass rod, spindle and PVC ball for water cooler for any type and make of water cooler any make 120/60 or 80/40 ltr capacity as per site reqirement all as specified directed .
M&L for charging R-134A gas to sealed compressor unit of water cooler of any type and make of unit of water cooler 80/40 ltr capacity complete including testing against leakage and effective cooling all as specified and directed .
Supply only new thermostat for 80/40 ltr capacity of water cooler.
Supply only new capillary tube suitable for 120/60 or 80/40 Ltr capacity of water cooler all as specified and directed.
Supply only push faucets suitable for 120/60 or 80/40 Ltr capacity of water cooler all as apecified and directed,
Cutting the existing damaged body surfaces of water cooler, including repairing and making good to the surface with 20 gauge MS Sheet by welding, denting, soldering complete and spray painting with synthetic enamel paint of approved tint and after drying writing MES Nos for the following capicity of water cooler Unsv docan handle change in a new with steel stand replace all as specified and directed
(b) 120/60 Ltrs
Material and Labour for preparation of steel surface of water coller of following capacity by Scrubbing the existing paint with emery paper, washing, filling of cavities removing denting etc and carry out two coat of synthetic enamel paint of approved tint over a coat of red oxide primer including writing MES Nos all as specified and directed.
(b) 120/60 Ltrs
Supply only new capacitor suitable for 40/60 or 80/40 Ltr capacity of water cooler all as specified and directed.
Supply only new capacitor suitable for 10/15 or 80/40 Ltr capacity of water cooler all as specified and directed.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule 'A' notes for details.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
TENDERDOCUS8868.pdf
Tender Documents • 1.37 MB
BOQ_846935.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid