Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC 62 | LUCKNOW | UTTAR PRADESH | 226001 | ₹26.2 L | L1 | Accepted-AOC Accepted as per first lowest and approved by competent authority |
| 2 | L2₹26.2 LRejected-AOC MOHALLA BAZAR MIRANPUR KATRA SHAHJAHANPUR | SHAHJAHANPUR | UTTAR PRADESH | 242001 | ₹26.2 L | L2 | Rejected-AOC Rejected as per second lowest |
| 3 | L3₹26.3 LRejected-AOC 15 KASARAK MIRANPUR KATRA TILHAR SHAHJAHANPUR | SHAHJAHANPUR | UTTAR PRADESH | 242001 | ₹26.3 L | L3 | Rejected-AOC Rejected as per third lowest |
| Sl No | Description | Qty | Unit | VRIDHHI ENTERPRISES L1 | JINDAL ASSOCIATES L2 | SHEELA ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00Schedule 'A' CONSTRUCTION OF RECHARGE WELL | ||||||
| 1.01 | Transportation of drilling Rig machine. | 1 | Job | 3,990 ₹3,990 | 3,996 ₹3,996 | 3,998 ₹3,998 |
| 1.02 | 350 mm Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment’s, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. | 180 | RM | 617.96 ₹1.1 L | 619 ₹1.1 L | 619 ₹1.1 L |
| 1.03 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of 150 mm dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. | 114 | RM | 633.29 ₹72,195.06 | 634 ₹72,276 | 635 ₹72,390 |
| 1.04 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. | 51 | RM | 644.62 ₹32,875.62 | 646 ₹32,946 | 646 ₹32,946 |
| 1.05 | Providing and fixing suitable size threaded mild steel cap or spot-welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell. | 3 | Each | 196.75 ₹590.25 | 197 ₹591 | 197 ₹591 |
| 1.06 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. | 3 | Each | 1,611.91 ₹4,835.73 | 1,614 ₹4,842 | 1,615 ₹4,845 |
| 1.07 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). | 3 | Each | 257.07 ₹771.21 | 257 ₹771 | 258 ₹774 |
| 1.08 | Development of tube/bore well by hi-capacity pump. | 60 | Per Hour | 498.75 ₹29,925 | 500 ₹30,000 | 500 ₹30,000 |
| 1.09 | Supply & filling of Pea Gravel around PVC pipe assembly at drilling site. | 24 | Per Cum | 6,284.25 ₹1.5 L | 6,294 ₹1.5 L | 6,297 ₹1.5 L |
Tender Value
Refer Docs
EMD Value
₹53,000
Closing Date
24 Nov 2025, 10:00 amClosed
Executive Engineer GWD Division Kanpur
Plot No. 34, W-2, Damodar Nagar, Kanpur
Installation/Construction of Roof Top Rain Water Harvesting Structure at buildings in campus of Jawahar Navoday Vidyalay Sarasul, Kanpur Nagar
2025_UPGWD_1091642_1
09/RWH/KNP/2025-26
Open Tender
Civil Works - Others
75 days
Jawahar Navoday Vidyalay Sarasul, Kanpur Nagar
As per Tender Notice
5 documents required · 5 mandatory
₹2,354
₹53,000
6 Feb 2026
18 Nov 2025
24 Nov 2025
18 Nov 2025
24 Nov 2025
18 Nov 2025
Amount
Schedule 'A' CONSTRUCTION OF RECHARGE WELL
Transportation of drilling Rig machine.
350 mm Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment’s, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of 150 mm dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot-welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
Development of tube/bore well by hi-capacity pump.
Supply & filling of Pea Gravel around PVC pipe assembly at drilling site.
Supply & Proving of Bentonite powder as per site requirment.
Supply & installation of 150 mm dai B-Class MS pipe.
Supply and installation of 150 mm dai MS air vent system.
Schedule 'B' CONSTRUCTION OF RECHARGE TANK AND FILTER CHAMBER
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavataed soil and disposal of surplus excavated soils as directed, within lead of 50 m including dressing of sides and ramming of bottoms, lift up to 1.5 m including getting out the all kind of soil.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.
Filling of excavated earth in trenches, plinth, sides of foundation etc. by ramming and watering.
Providing & laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand (zone III) : 8 graded stone aggregate 40 mm nominal size) excluding of cost of centering, shuttering all work upto plinth level.
Brick work with common burnt clay (non modular) bricks of class 150 in foundation and plinth in cement mortar 1:4 (1 cement : coarse sand).
Providing and laying damp proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone III):4 graded stone aggregate 12.5 mm nominal size).
Providing and laying in position 1:2:4(1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal) of RCC, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level.
Centering and shuttering including strutting, propping etc. and removal of foundations, footings, bases of column, etc. for mass concrete.
8 mm dia TMT bars of grade Fe- 500D or more Steel reinforcement for RCC work including straightening, cutting, bending and placing in position binding all complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement , including cement slurry, but excluding the cost of nosing of steps etc. complete: 40 mm thick with 20 mm nominal size aggregate.
12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
Cartage of excavated soil 15 km away from the site including loading & unloading etc. complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Mosquito/Fly proof stainless steel grade 304 wire mesh gauge with 0.50 mm dia sia and 1.4 mm wide aperture.
Supply and fixing of Nylon mess for recharge filter including cutting, wastage etc.
Suppling & filling of following materials in recharge filter:
Loose Bricks at top.
Coarse sand layer below loose bricks.
Pea gravel of size 1.2 mm to 4.6 mm below coarse sand.
40 mm gauged stone ballast below Pea gravel.
Making provision of overflow system complete in all respect including cost of all materials.
Ledder
Schedule 'C' CONVEYANCE PIPE LINE WORK WITH CHAMBERS
Providing of PVC blind pipe as per IS: 12818 as follows:
100 mm dia. 6 Kgf/cm2 Pressure PVC Pipe.
150 mm dia. 6 Kgf/cm2 Pressure PVC Pipe.
200 mm dia. 6 Kgf/cm2 Pressure PVC Pipe.
Excavating trenches for pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m.
Demolishing cement concrete Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level in 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) in foundation & floors.
Two coats Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Construction of 900x900x900 mm size inlet chamber with class 150 brick work 1:3 cement mortar with RCC slab on top along with proper by-pass arrangement to run-off excess rain water.
Construction of 750x750x750 mm size inlet chamber with class 150 brick work 1:3 cement mortar with RCC slab on top along with proper by-pass arrangement to run-off excess rain water.
Construction of 600x600x600 mm size inlet chamber with class 150 brick work 1:3 cement mortar with RCC slab on top along with proper by-pass arrangement to run-off excess rain water.
Construction of 450x450x450 mm size inlet chamber with class 150 brick work 1:3 cement mortar with RCC slab on top along with proper by-pass arrangement to run-off excess rain water.
Schedule 'D' MAKING ROOF TOP SUITABLE FOR RAIN WATER HARVESTING
Supply & fixing of new down pipe with all required Tee, Coupler, Elbow, Reducer etc.
100 mm dia. 6 Kgf/cm2 Pressure PVC Pipe.
Providing & fixing of Ball Valve system with all required accessories for provision of drained off first rain water as per site requirment & instructions.
Schedule 'E' CONSTRUCTION OF PIEZOMETER 110 MM DIAMETER PVC PIPE ASSEMBLY
Water supply charges for drilling work.
Drilling of 200 mm dia bore well by DC rig machine including cost of labour, equipment etc, complete required for proper completion of work.
Providing of 100 mm dia CS/CM Casing Pipe (confirming IS:12818) assembly.
Providing of 100 mm dia CS/CM Ribbed Screen (confirming IS:12818) assembly.
Providing & fixing of 100mm dia threaded PVC end cap.
Providing & fixing of 150 mm dia MS pipe (confirming IS:1239)
Providing & fixing of MS clamp for holding of MS pipe.
Providing & fixing of 200 mm x 200 mm square MS plate including 4 nos. fasteners etc.
Providing & filling of Pea Gravel of size 2 mm to 4 mm dia into bore well including cost of labour, material etc. required for proper completion of work.
Development of bore well by 3 HP submersible pump.
Earth wprk in excavation in trenches for foundation in ordinary soil (Loam, Clay or Sand) including lift up to 1.50 m and lead up to 50 m.
Providing & laying of Cement Concrete of size 1.5mx1.5mx0.15m below CC block in 1:4:8 (Cement, fine sand and brick ballast 40 mm size) in foundation with ramming & dressing etc. complete work with all material, labour, T&P as required.
Providing & laying of Cement Concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ballast 20 mm nominal size ) including supply of all materials, labour and T&P etc. required for proper completion of work.
Fabrication & fixing of Security System as per design including cost of material, labour, etc. required for proper completion of work.
Fabrication & supply of angle Iron Sign board of frame size 1.20x0.90x1.95 mt. with cross strip & beading of size 30x4 mm welded on frame of MS angle size 40x40x5 mm and MS sheet of 18 gauge as per drawing & design including all labour, material and T&P etc. complete.
Fixing of legs of sign board on cement concrete block of size 0.30x0.30x0.60 mt. in ratio 1:3:6 as per drawing & design including all labour, material etc. complete.
Painting of angle iron sign board with double coat primer and enamel paint of black colour on frame both side and sky blue on MS sheet both side including all labour, material etc. complete.
Writing on angle iron sign board both sides of given matter with Post Office Red Color Fluorescent Paint as per drawing and detail given including all labour, material etc. complete.
JINDAL ASSOCIATES (BID ID -5692076)
SHEELA ENTERPRISES (BID ID -5693161)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
BOQ_2005457.xls
BOQ • 0.29 MB
Biddocument9.pdf
Tender Documents • 2.27 MB
Download all tender documents and submit your bid