Loading…
Loading…
Tender Value
₹43.3 L
EMD Value
₹86,700
Closing Date
7 Jan 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
CONS
23 conditions · 10 needing a document upload
The tenderer should submit the consent in a mandate form of Enclosure-1 for receipt of payment through NEFT
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Certificates which may be an attested Certificate from the client, Audited Balance Sheet duly certified by the Chartered Accountant etc regarding contractual payments received in the past
Tenderer shall indicate their GSTIN No. & PAN No. with proper document proof.
If the tenderer wish to submit Bank guarantee for bid security (EMD), the Tenderer shall download the Tender Document Annexure -VI A for bid security in the form of bank guarantee and upload the Annexure -VI A duly filling the necessary details. The original Bank Guarantee should be delivered in person to Office of the PCEE, II floor, Shell Administrative building, ICF, Chennai - 600 038 before closing date for submission of bids (i.e. excluding the last date of submission of bids)
The Tenderer shall have valid required level Electrical License. Attested copy of the Electrical License shall be submitted along with the offer.
The successful tenderer shall prepare and submit the Scheme for wiring along with layout of arrangement of Electrical switchgear drawings according to the site and obtain approval from the competent authority or their authorized representative prior to the commencement of work.
After completion of all wiring and installation, the successful tenderer shall submit 3 sets of General arrangement and Schematic drawings along with the electrical wiring documentation.
The rate quoted shall be net inclusive of all taxes (GST) and duties.
The Contractor has to engage only Police verified Pvt. labour /Pvt. Employee. If any new person (other than already verified) to be engaged by the contractor, he has to submit proof of Police verification application for issuing a "Temporary permission" like present permit system. However, Contractor has to arrange PV report within permissible period of one month.
The tenderer shall download the Tender Document Annexure -I and upload the Annexure -I duly filling the necessary details.
Electrical Works for a) Extension of Traverser Pit at Eastern side of Shop-30/Fur & b) Provision of crane girders in I and II bay of New shed southern side of shop 33 and 39.
2025245212046~ICF
2025245212046
Open
Works - General
6 Months
Chennai, Tamil Nadu
₹0
₹86,700
7 Jan 2026
8 Dec 2025
24 Dec 2025
36 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 9,80,772 | ||
| — | 80.00 | — | — | ||
| Supply installation, testing & commissioning of Compact Shrouded Mobile Copper Conductor system, rating - 250Amps 4 line (R, Y, B & G), with accessories as per ICF Specification. Rate for straight Path (Rs/M) | — | — | — | 3,77,600 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing & commissioning of Expansion assembly for shrouded mobile copper conductor system as per ICF Specification. | — | — | — | 472 | |
| — | 80.00 | — | — | ||
| Supply of Support brackets for mounting the shrouded DSL mobile copper conductor system (one support required for every Meter of Straight path) including canopy with weatherproof coating for outdoor use as per ICF specification. | — | — | — | 1,88,800 | |
| — | 4.00 | — | — | ||
| Supply installation testing and commissioning of 125 Amps Double arm current collector as per ICF specification. (1 set=08 no's) | — | — | — | 75,520 | |
| — | 2.00 | — | — | ||
| Supply Installation n testing and commissioning of Indication Lamps (LED ARRAY MODULAR TYPE) with suitable fixing brackets to fix at both ends of the shrouded bus bar system (l Set =2 no's) | — | — | — | 9,440 | |
| — | 1.00 | — | — | ||
| Supply and erection of 315 Amps TPN SFU in sheet steel enclosure as per ICF Specification. | — | — | — | 33,040 | |
| — | 80.00 | — | — | ||
| Fixing of support bracket on Crane girders for mounting the Shrouded mobile copper conductor system. | — | — | — | 1,41,600 | |
| — | 80.00 | — | — | ||
| Removal of Old supporting brackets as per ICF specification. | — | — | — | 47,200 | |
| — | 5.00 | — | — | ||
| Supply, Erection, Testing & commissioning of Earthing Electrode to Drg No. ICF/EL/1289 inclusive of supply of all reqd. materials like 50 mm dia pipe, copper strip of size 25X3 mm, all reqd. hardware and all other materials etc., as per ICF Specification. | — | — | — | 44,800 | |
| — | 100.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
916TenderDocument.pdf
ATTACHMENT
LISTOFMachinery.pdf
ATTACHMENT
NEFTForm.pdf
ATTACHMENT
IRGCCACSCombined_2.pdf
ATTACHMENT
LISTOFPERSONNEL_1.pdf
ATTACHMENT
TenderFormAnnexure-I.pdf
ATTACHMENT
IRGCC_April-2022.pdf
ATTACHMENT
annex6B.pdf
ATTACHMENT
LISTOFWORKSONHAND.pdf
ATTACHMENT
LISTOFCONTRACT.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .