Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹27.5 L+₹2.9 L (11.7%)Accepted-AOC | L2 | Accepted-AOC Other than lowest bid | |
| 3 | L3₹27.9 L+₹3.3 L (13.4%)Accepted-AOC | L3 | Accepted-AOC Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
22 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 874 EWS
GE 874 EWS C/O 56 APO
REPAIR MAINT OF EXTERNAL ELECTRIC SUPPLY NETWORK POWER AT ZANGLI AND DRUGMULLA
2024_MES_660686_1
GE 874/EWS-42/2024-25
Open Tender
Civil Works
Works
180 days
KUPWARA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 874 EWS C/O 56 APO
₹64,000
26 Oct 2024
19 Jun 2024
25 Jul 2024
20 Jun 2024
22 Jul 2024
8 Jul 2024
Amount
Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for foundation of poles, stay assembly and laying of LT/HT cable in any type of soil and getting out complete all as specified and directed.
All as per ser item No 1 above but depth exceeding 1.5 m and not exceeding 3 m.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removal of excavated material to a distance not exc. 50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
M&L for sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and directed. Note: Punned thickness 18 CM shall be measured.
Material and labour for kiln burnt Sub class 'B' bricks laid dry, flat width wise along the length of cable in trenches after sand cushioning for protection of underground cable complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in bed of poles and stays complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type C-2 using 40 mm graded crushed stone aggregate as in pole coping and stay assembly complete all as specified and directed.
M&L for plain cement concrete in foundation of poles streets and stays (1:3:6), type D-2 using 40 mm graded crushed stone aggregate complete all as specified and directed.
Supplying, laying, commissioning and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old unserviceable damaged cables of following sizes.
(a) 16 sqmm, 4 core
(b) 25 sqmm, 3.5 core
(c) 35 sqmm, 3.5 core
(d) 50 sqmm, 3.5 core
(e) 70 sqmm, 3.5 core
(f) 95 sqmm, 3.5 core
(g) 120 sqmm, 3.5 core
(h) 185 sqmm, 3.5 core
(j) 240 sqmm, 3.5 core
Supplying, laying, commissioning and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old unserviceable damaged cables of following sizes.
(a) 95 sqmm, 3 core
(b) 120 sqmm, 3 core
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination, Cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE /(ABC), armoured, Aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE /(ABC), armoured, Aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE /(ABC), armoured, Aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE /(ABC), armoured, Al conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
M&L for straight through joint, heat shrinkable tubular type of size 70 to 150 sqmm,3.5 core, 1100 volts grade complete all as specified and directed.
M&L for GI pipe 40mm dia bore, light grade for road crossing of cable or for protection of cable above ground surface complete all as specified and directed.
M&L for GI pipe, light grade 50mm dia bore for road crossing of cable or for protection of cable above ground surface complete all as specified and directed.
Taking down old unserviceable indicator lamp S&F in repair Phase LED indicator lamp R, Y & B complete all as specified and directed.
S & F in replacement steel tubular swaged poles erected truly vertical or planted as strut complete with 300 x300x 6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II. type 410 SP-31 (9.0 metres long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally & portion embedded in concrete, making five black & yellow bands at lower portion of pole each 300mm wide alternately, and making pole No. with black paint at suitable height complete all as specified and directed.
S & F in replacement steel tubular swaged poles erected truly vertical or planted as strut complete with 300 x300x 6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II. type 410 SP-55 (11.0 metres long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally & portion embedded in concrete, making five black & red bands at lower portion of pole each 300mm wide alternately, and making pole No. with black paint at suitable height all as specified and directed.
M&L for mild steel cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, including taking down unserviceable/old cross arms complete all as specified and directed.
Supply & fixing following LT, PVC line spacer/separator complete all as specified and directed.
(a) PVC line spacer 2 wire
(b) PVC line spacer 3 wire
(C) PVC line spacer 4 wire
M&L in replacement of ACSR conductor of any size and any type including stretching, fixing and binding to insulator on OH HT/LT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified. This item includes all consumables (such as binding wire and replacement insulators and cross arms, etc., for replacement of damaged ones found after/ during replacement process) complete all as specified and directed.
M&L in replacement of pin type porcelain vitreous white brown or green insulator including one galvanized mild steel spindle, two galvanized iron, washers and one galvanized iron nut, 150 mm height, 150 mm dia for 11000-volt grade complete all as specified and directed.
S&F disc type porcelain, vitreous, white, brown or green insulators for working pressure 11000 volts grade, with bolts, washers and nuts, complete all as specified and directed.
M&L in replacement of Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 31 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified and directed.
M&L in replacement of pin type porcelain vitreous white brown or green insulator including one galvanized mild steel spindle, two galvanized iron, washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100-volt grade complete all as specified and directed.
M&L in replacement of Stay assembly for electric pole complete with accessories as shown in electrical plate No 1 of SSR Pt-I and drawing using loop type insulator, stay clamps, stay rod of 16 mm dia including stay wire of size 7/3.15 mm complete all as specified and directed. Excavation, earth work and concrete shall be measured and paid separately under respective item of BOQ.
M&L for servicing of LT Panel indoor/outdoor by Welding, greasing, tightening of nut bolts, insulation of bus bar with colour code, checking of continuity of internal wiring of panel, replacing burnt MCCB of capacity 63/100/200/250 Amps, including scrapping old worn out paint from panels and painting with two coats of synthetic enamel paint over a coat of primer with spray painting complete all as specified and directed. NOTE :- MCCB will be measured and paid separately under respective item.
S&F in replacement of Manual change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 63 Amp complete all as per existing sample complete all as specified and directed.
S&F in replacement of Manual change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 100 Amp complete all as per existing sample complete all as specified and directed.
S&F in replacement of Manual change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 125 Amp complete all as per existing sample complete all as specified and directed.
S&F in replacement of Manual change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 160 Amp complete all as per existing sample complete all as specified and directed.
S&F in replacement of Manual change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 200 Amp complete all as per existing sample complete all as specified and directed.
S&F in replacement of on load change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 100 Amp complete all as per existing sample complete all as specified and directed.
S&F in replacement of on load change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 125 Amp complete all as per existing sample complete all as specified and directed.
S&F in replacement of on load change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 160 Amp complete all as per existing sample complete all as specified and directed.
S&F in replacement of on load change over switch 415 volt in sheet metal enclosure 4 pole of capacity from 320 Amp complete all as per existing sample complete all as specified and directed.
S&F of MCCB 125 Amp 4 pole 415 Volt breaking capacity 35 kA.as per sample which is suitable for existing panel Make Havells or Equivelent Make of L & Tor C&S
S&F of MCCB 200 Amp 4 pole 415 Volt breaking capacity 35 kA. as per sample which is suitable for existing panel Make Havells or Equivelent Make of L & Tor C&S
S&F of MCCB 320 Amp 4 pole 415 Volt breaking capacity 35 kA.as per sample which is suitable for existing panel Make Havells or Equivelent Make of L & Tor C&S
S&F of MCCB 400 Amp 4 pole 415 Volt breaking capacity 35 kA. as per sample which is suitable for existing panel complete all as specified and directed.
S&F of MCCB 630 Amp 4 pole 415 Volt breaking capacity 50 kA. as per sample which is suitable for existing panel complete all as specified and directed.
S&F lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, 11000 volts grade complete all as specified and directed.
Supply, installation, commissioning and testing switch air break, gang operated with 12 insulator switch triple pole mechanically operated, mounted on insulators and steel frame with mechanism worked from ground level for current rating 400 Amp operating voltage 11 KV outdoor type vertical mounted type complete with locking arrangement, assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV Fuse (drop out type) of capacity 10 Amps. complete with DO fuses with one number operating rod of 25 mm dia bore grade GI pipe of suitable length worked out from ground level and handle complete including flat iron clamp 50mmx6mm, MS channel of suitable size & length for fixing GOD including nut bolt washers including taking down existing set complete all as specified and directed.
Scraping of old paint from pole and painting to poles, 11 mtr with cross arms, bracing and clamps with one coat of synthetic enamelled paint over one coat of red oxide primer including scrapping the old paint carefully to make smoothen complete and painting strips of Yellow and black from foot of pole up to 5 feet each strip of 30 cm height complete all as specified and directed.
All as per description of srl item No 49 here-in-before but for LT pole 9 mtr long and painting strips of yellow & black from foot of pole up to 5 feet each strip of 30 cm height.
Supply, installation in replacement, connecting electrically and testing of street light junction box size 450x250x300mm, pole mounted made out of CRCA sheet 2 mm thick , powder coated having door with magnetic lock complete with bus bar 4 Nos suitable for 3 phase 4 wire supply system, made of aluminium strip of size 20X3mm, one single pole MCB, 240 volts 'C' Curve type, 6 Amps with rupturing cap 10 KA, including fixing arrangement made of MS FI Clamps of requisite size nuts, bolts and washers complete all as specified and directed.
Supply and fixing in replacement GI bracket for fixing of street light fittings bend to shape, made out of 32mm GI pipe light grade up to 1.5m long fixed with and including clamps made from flat iron of size 40x4mm, MS clamps bolt, nuts & washers & two coats of aluminium paint over a coat of red oxide primer, including taking down old unserviceable complete all as specified and directed.
M & L for Multistranded copper conductor heavy duty cable PVC insulated minimum conductor, served with inner sheathing of PVC tape and overall PVC sheathed of size 2.5 sqmm 3 core for street light connection including taking down existing old unserviceable cable and removal from site complete all as specified and directed.
S&F for rigid non-metallic PVC conduit of 20 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. heavy-duty wall thickness 2.00mm for street light fittings including taking down old unserviceable PVC conduit complete all as specified and directed. Note- PVC conduit will be fix with suitable MS flat iron clamp including bolts and nuts etc fix on pole.
Supply and fixing LED Flood light fitting 50-Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED Flood light fitting 100-Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED street light fitting 35-Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED street light fitting 60-Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm × 60cm and 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Supply and fix danger sign board made out of 1.6 mm thick MS sheet vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed on LT poles with MS Bolts and Clamps, bolts, nuts of size 20x15cm complete all as specified and directed.
Supply and Fixing LT/HT Cable route marker (self-embossed LT Cable and HT Cable) round shaped alloy metal plate fixed with 2 feet angle iron which includes red and yellow colour synthetic enamel painting work, excavation and PCC works complete all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 16 Sqmm complete all as specified and directed
M/S MOHD MAQBOOL RATHER
GH MOHD SHAH AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .