Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.8 L+₹6.7 L (21.6%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance Rejected in AOC | |
| 3 | L3₹37.9 L+₹6.8 L (22.0%)Rejected-Finance 96 L BLOCK WARD NO 06 SRI VIJAYNAGAR SRI GANGANAGAR RAJASTHAN 335704 | SRI VIJAYNAGAR | SRI GANGANAGAR | RAJASTHAN | 335704 | L3 | Rejected-Finance Rejected in AOC | |
| 4 | L4₹40.9 L+₹9.9 L (31.8%)Rejected-Finance | L4 | Rejected-Finance Rejected in AOC |
Tender Value
₹44.2 L
EMD Value
₹88,400
Closing Date
14 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY SURATGARH
SURATGARH MIL STN
Provn of security watch tower at back side of Ramsingh Pura ASCON Node, walkway for perimeter patrolling and certain sanctioned works under GE (Army) Suratgarh at Suratgarh Mil Stn
2021_MES_460730_1
GE (A) SOG - 29/21-22
Open Tender
Civil Works
Item Rate
180 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹88,400
Yes
11 Sept 2021
17 Jul 2021
16 Aug 2021
17 Jul 2021
14 Aug 2021
31 Jul 2021
60 days
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Demolition and breaking up 150 mm bore drain pipes (salt glazed stone ware, AC or reinforced concrete) including concrete bed and haunching and removing rubbish to a distance not exc 50m complete all as specified and as directed by Engineer-in-charge.
Excavation over areas not exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each not exc 0.50 cum in soft / loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed by Engineer-in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance exc 250 metre and not exc 500 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance exc 1.5 KM and not exc 5 KM and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out complete all as specified and directed by Engineer-in-Charge.
Spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engineer-in-Charge
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for 150mm thick (spread thickness) soling (or sub base) with broken boulders or quarried stone, interstices filled, surface formed & rolled and consolidated to required gradient and camber with 8 to12 tonne power roller complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M&L for hard core of stone / boulders of gauge exceeding 63mm but n. exc 100mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for hard core of broken bricks aggregate of gauge exceeding 63mm but n. exc 100mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M & L for PCC (1:3:6) typeC-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed by Engineer-in-charge. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
M&L for cement concrete (1:3:6),type C-1, using 20mm graded stone aggregate as in coping, bed blocks, filling chowkats or similar work complete all as specified and directed by Engineer-in-Charge.
M&L precast cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in window or door cills, lintels, brssumers, steps, quoin blocks (for use with masonary), string courses, copings, kneelers, apex stones, kerb stone, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks and simillar articles with plain faces, corbels, brackets, etc (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc and set in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in landing, cover slab for manholes, septic tanks, soakage wells, chullah hood, chajjas, water troughs, mangers, shelves and similar articles with plain fair faces including chamferred, weatherings, throating etc including necessary form work complete all as specified and directed by Engineer-in-Charge Note: - Reinforcement shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) nominal mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc ; basement slabs, under- reamed piles and mass concrete complete all as specified and directed by Engineer-in -charge.
M&L for reinforced cement concrete M-25 design mix using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc ; basement slabs, under- reamed piles and mass concrete complete all as specified and directed by Engineer-in -charge.
M&L for reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in beams, cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for providing reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate as in column, pillars, piers, posts and sturts complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) nominal mix as in columns, pillars, piers, post and struts complete all as specified and directed. by Engineer-in -charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for brick work in half brick thick wall using fly ash bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick damp proof course to horizontal or vertical surfaces in PCC (1:2:4) type B0 including necessary form work and applying evenly a coat of blown type bitumen @1.50 Kg per Sqm and binding with clean dry sand @ 0.05 Cum per Sqm complete all as specified & directed by Engineer-in-Charge.
M&L for 40mm thick damp proof course to horizontal or vertical surfaces in PCC (1:2:4) type B0 including necessary form work and applying evenly a coat of blown type bitumen @1.50 Kg per Sqm and binding with clean dry sand @ 0.05 Cum per Sqm including polythene film 50 micron thick, laid on a coat of bitumen primer complete all as specified & directed by Engineer-in-Charge.
M&L for 40mm thick damp proof course to horizontal or vertical surfaces in PCC (1:2:4) type B0 using water proofing compound including necessary form work complete all as specified & directed by Engineer-in-Charge. Note : - Supply only water proofing compound shall be measured and paid for separately
M&L for continuous brick edging (sub class ‘B’) with width equal to the length of brick laid dry on edge vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified and directed by Engineer-in-Charge. Note : Each row shall be measured and paid separately.
M&L for continuous brick edging (sub class ‘B’) with width equal to the width of brick laid dry on end vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified. Note : Each row shall be measured and paid separately.
M&L for use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces of concrete flat complete all as specified and directed.
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
M&L for Square, Circular rectangular on plan or polygonal use and waste of form work to sides pillars, posts, struts, pier, columns and stanchions for rough finished surfaces of concrete complete all as specified and directed.
S&F 35 mm thick factory made plain framed, panelled shutter (any number of panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood (Hollock or Bonsum) complete all as specified and directed by Engineer-in-charge.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick one side prelaminated PVC sheet reinforced with MS square tube and edges painted to match the prelaminated sheet complete all as specified & shown in relevant drawing of item No. 08095 to 8097 in MES Schedule (Part-II) and directed by Engineer-in-Charge
S&F 30mm thick factory made solid core PVC door shutter (style) consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC sheet, 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in mild steel frame welded/ sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement, complete, all as specified & shown in relevant drawing of item No. 08080 in MES Schedule (Part-II) and directed by Engineer-in-Charge.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 200 mm long mild steel barrel tower bolt stove enamelled black with bright bolt (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size mild steel butt hinges cold rolled medium weight (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size butt hinges of extruded aluminium alloy with galvanized mild steel hinge pin, anodized type B-21 (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 125mm long extruded aluminium handles, anodised, fabricated type (ISI marked) complete all as specified and directed by Engineer-in-Charge
S&F 150mm long extruded aluminium handles, anodised, fabricated type (ISI marked) complete all as specified and directed by Engineer-in-Charge
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 140mm (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-charge.
S&F powder coated mild steel drapery rod of 20 mm inner dia (in lengths as directed) of approved colour with & including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam, including PVC curtain rings of matching colour @ 10cm C/C all as specified & as directed.
S&F mild steel work as in hold fast, wind tie for roof covering including securing bolts necessary drilling bolts or reiveting conforrming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge
M&L for mild steel pipes as in Hand rails,half round,nosing to steps including embedding in concrete securing bolts,posts and struts in fencing incld drilling bolting or riveting etc. wind tie for roof including cutting topes to shape as directed, drilling holes, notching for wire etc, flat iron (for securing wire mesh) conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer-in-Charge.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape as in tie bar fixed to chain link fencing including necessary welding where required as per site requirement & other similar works conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-charge.
S&F MS screw bolt 05 to 10mm dia, length of bolt not exceeding 50mm long machine made with hexagonal or square head at one end and screwed the other or serewed both ends, each screwed end fitted with washer and one hexagonal or square nut complete all as specified and directed by Engineer-in-Charge.
S&F 16 to 20mm dia, length exceeding 22.5 cm and not exceeding 30cm long, MS screw bolt (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and directed by Engineer-in-Charge.
Supply only mild steel galvanized chain link fencing of any mesh, size and type complete all as specified and directed by Engineer-in-charge. Note:- (i) Flat iron, round bars, nut bolts and washer shall be measured and paid for separately. (ii)The payment shall be made to the contractor for actual weight ascertain by the BOO as odered by GE.
Fixing only mild steel galvanized chain link fencing any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and directed by Engineer-in-charge. Note :- Supply only chain link fencing shall be measured and paid for separately under replace items of BOQ.
S&F mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
All as per serial item No 67 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers & binder etc.
S&F mild steel round bars as in window guard bars incl necessary welding and a shop coat of zinc primer confirming to Fe-290 (Gde-E-165) complete all as specified and directed by Engineer-in-Charge.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe-290 (Gde E- 165, complete all as specified & directed by Engineer-in-charge.
M&L for drain cover made of stainless steel grating width 230mm able to withstand 100 kg of load and having min weight 2.50 kg per running meter complete all as specified and directed by Engineer-in-charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
M&L for steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 including painted with one shop coat of zinc chromate primer paint including preparation of surface at contractor workshop before fabrication complete all as specified and directed by Engineer-in-charge.
S&F factory made steel ventilator with top hung shutter including hinges, steel peg stay, handle including one shop coat of Zinc Chromate primer and cutting holes in brick wall built in cement mortar for inserting lugs and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in-charge.
S&F pressed steel frames for door of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc made out of mild steel sheet of 1.25mm thickness complete all as specified and as directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F Anodised aluminium snap grid frame work of size 605mm x 605mm for false ceiling including necessary notching. The snap grid shall consist of anodized aluminium main & cross Tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM and 23.5mm x 26.4mm x1.40mm weighing 0.191Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminium angle bracket of size 15mm x 15mm x 1.5mm weighing 0.12Kg /RM fixed with suitable MS bolts, nuts and washer. The snap grid (main /cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size 35mm x 25mm x 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement duly suspended with 3mm dia GI wire length as required @ 600mm C/C with adjustable device including plugging in brick / concrete work with steel raw plugs including making good all the disturebed portion complete all as specified and directed by Engineer-in-Charge.
M&L for 4mm thick E board classic, fibre base cement boards, embosed texture, fixed to aluminium snap grid (size of grid 605mm x 605mm) in ceiling complete all as specified and directed by Engineer-in-charge. Note :- The aluminium snap grid frame work shall be measured & paid for separately.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 15mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L machine cut Kota stone slab 18 to 20mm thick on treads & risers of staircase laid over & including screed bed or bedding layer of 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified. Note :- The Kota stone shall be provided in single piece on each tread & riser. The front edges of treads shall be rounded off by grinding as directed. These provisions shall deemed to be included in quoted rates.
M&L stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide, 150mm deep and sides dressed, bedded in cement mortar 1:3, cement mortar 1:2 with an admixture of metallic floor hardener, 5% by weight of cement and struck flush complete all as specified and directed by Engineer-in-Charge.
M&L for edge stone to stone sett flooring with stone setts of size 250 to 300mm long, 150 to 200mm wide and 450mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as specified and directed by Engineer-in-charge.
M&L for 50 mm thick PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate as in flooring finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in flooring, finished even and smooth without using extra cement cement complete all as specified and as directed by Engineer-in-charge.
M&L for 100mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in floor, top surface finished fair & even including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed. Note :- PCC shall be laid in alternate bays in panels of size not exc 2m x 1m and joints shall be filled with bitumen mastic (1:3). Quoted rate shall deemed inclusive for same.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
S&F factory casted 60mm thick machine pressed cement concrete interlocking paving blocks M-35 having compressive strength not less than 350 Kg / Sqcm using grey cement and no pigment and of shape hexagon/ triangular / zigzag / I-shaped / Three-X etc as directed conforming to IS 15658-2006, laid over & including 25mm thick sand cushion (local tibba sand), laid dry, joint filled with dry sand complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in two layer on stone masonry surfaces or surfaces other than fair face of brick work of walls consisting of 1st layer of 10mm thick plaster in CM 1:6 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4 mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished fair & even, complete, all as specified and directed. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 5mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint and filling cement based putty in cracks complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new untreated steel and iron surfaces of any description, not exc. 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge
S&F 4mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. Note :- Excavation and earthwork shall be measured and paid for separately under respective items of BOQ.
S&F 25mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. Note :- Excavation and earthwork shall be measured and paid for separately under respective items of BOQ.
M&L cutting existing GI water main pipe line in position of 40mm bore and making connection of new pipe line of 40mm bore with & including insertion of new GI Tee of size 40mm x 40mm x 25mm including excavation & earth work in any type of soil complete all as directed.
S&F gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F 450mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S&F Towel rail, 450mm long of PTMT fixed with and including chromium plated brass screws and wooden and plastic cleats ( minimum weight 170gms ) complete all as specified & directed by Engineer-in-Charge.
S&F brass chromium plated tubular towel rail 20mm dia; 'D' type, 600mm long between flanges fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge.
S&F grating doom 100mm dia of PTMT with waste hole (minimum weight 25 grams) complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical double layered with closed top) hoisted and fixed in position of capacity 500 litres including ball brass valve, high pressure with polythene float and flynut screwed for 20 mm dia GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (All GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 117 here-in-before but 1000 ltrs capacity
S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shankS&Fly nuts, screwed suitable for iron pipes of 15mm bore complete all as specified and directed by Engineer-in-charge.
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Ball valves, high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball, screwed for iron pipe 20mm dia (minimum weight 210 gms) complete all as specified and as directed by Engineer-in-charge.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (angular type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F toilet paper holder chromium plated complete all as specified & directed by Engineer-in-Charge.
S&F chromium plated Soap dish holder including chromium plated brass screws and plastic cleats complete all as specified & directed by Engineer-in-Charge.
S&F vitreous china wash basin white flat back of size 630 x 450mm including a pair of angle iron brackets, PVC connection, 15mm dia fancy type, cast copper alloy chromium plated pillar tap with capastan head screwed down high pressure with long screwed shank and fly nuts, 32mm dia full threaded PTMT waste coupling including cutting for and pinning in ends of brackets and 32mm dia high density polythelene (HDPE) pipes for pressure rating 6 Kg/Sqcm with all fittings such as sockets, bends, tapers, etc complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash basin white, flat back of size 550x400mm including including a pair of cast iron brackets embedded in PCC 1:3:6 type C-1 blocks of size 10 x 7.5 x15 cm with & including 32 mm dia PVC waste pipe, 32mm dia PTMT waste coupling half or full thread (minimum wt 45 grms) flange end bedded in red lead cement & other end fixed to waste pipe and including brass chromium plated fancy type pillar tap, screwed suitable for iron pipes of 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed by Engineer-in-charge.
S&F 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge.
S&F plastic water closet seat, white, closet pattern with flat bottom and cover and mild steel chromoum plated or aluminised hinging device complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia inlcuding urinal spreader complete all as specified and directed by Engineer-in-charge.
S&F PVC toilet cabinet with mirror of size 450x600mm complete all as specified & directed by Engineer-in-Charge.
S&F jet spray chromium plated brass for ewc with & including PVC connection 600mm long suitable for 15mm bore GI pipe complete all as specified & directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
M&L 100mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) bends any radius jointed with adhesive with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) bends any radius jointed with adhesive with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge
S&F 75mm bore PVC (SWR) junction,single (single T) equal or unequal complete all as specified and directed by Engineer-in-Charge"
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe complete all as specified and directed by Engineer-in-charge.
M&L for 150mm bore salt glazed stone ware drain pipes of grade ‘A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified and directed by Engineer-in-charge.
Material & labour construction of Soak Well for 26 to 50 users as shown on drawing No.GE(A) /comp / 17 / 2016 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, brick work shall be in CM 1:4, over burnt brick bats shall be used for filling, PCC 1:4:8 type D2 using 40mm graded stone aggregate shall be provided in foundation, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided, PCC 1:3:6 type C2 using 40mm graded stone aggregate shall be provided in plinth protection, 1.50m long 150mm bore cast iron sand cast inlet pipe shall be provided and slab shall be Precast RCC (1:2:4). Other details shall be as shown on drawings & as specified in particular specifications.
Material & labour construction of Soak Well for 51 to 100 users as shown on drawing No.GE(A) /comp / 17 / 2016 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, brick work shall be in CM 1:4, over burnt brick bats shall be used for filling, PCC 1:4:8 type D2 using 40mm graded stone aggregate shall be provided in foundation, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided, PCC 1:3:6 type C2 using 40mm graded stone aggregate shall be provided in plinth protection, 1.50m long 150mm bore cast iron sand cast inlet pipe shall be provided and slab shall be Precast RCC (1:2:4). Other details shall be as shown on drawings & as specified in particular specifications.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 150 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 150 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per Srl item No. 150 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408618 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 32 Amps, Single Pole & Neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408617 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F LED Lamp 12 watts suitable for normal holder complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 or equivalent in makes mentioned in Appendix 'A' here-in-after. Make of MCB :- Legrand Cat Part No 408593 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim, prewired, lumiline 18 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS18WLED 865SPCWH / Syska Cat part No SSK-RA1801 Wipro cat part No LL20-221-XXX-65-NE / Philips cat part No 61009 BL CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED 865SPCWH / Syska cat part No SSK-T5T-9W / Crompton cat part No LCTLN-10-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F exhaust fan 300 mm sweep,900 RPM trans air, with louver shutter suitable for operation on 230 volts, single phase , AC and connecting up including 2 core,1.0 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge. Make :- Havells Model No Terbo Jet SP or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F wall mounted fan 450 mm sweep, 7500 CPM, single phase, 230 volts, 50 Hz with IP 55 protection and connecting up and including 3 core,1.5 sqmm PVC insulated if required & PVC sheathed copper conductor flexible cable drawn in flexible conduit fixed on wall complete all as specified & directed by Engr-in-charge. Make :- Havells Model Airbol-Hi Speed or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F water storage heater (geyser) of 25 ltr capacity, energy saving 5 star rating complete with fire retardant cable and 3 pin plug 15/16 Amp, including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge. Make :- Havells Product code GHWAMJSIV025 (Model Monza Digi) or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F street light bracket made out of 40mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing LED Street / Security light fitting of 30 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Syska Cat part No. SSK-SLG-CF-30W / Crompton Cat Part No LSTS-30-CDL-M / Havells Cat part No ENDURAPEARL SL30WLED757SASYTOPCMP / Wipro Cat Part No LR02-331-XXX-57-XX or equivalent in makes mentioned in Appendix 'A' here-in-after.
All as per Srl item No 173 above but LED street / security light of 45 watt. Make :- Syska Cat part No. SSK-SLF-F-45W-WL / Crompton Cat Part No LSTV-45-CDL / Havells Cat part No ENDURAPEARL NEOSL45WLED757SASYTOPC / Wipro Cat Part No LR02-501-XXX-57-XX or equivalent in makes mentioned in Appendix 'A' here-in-after.
Notes for srl Item No 173 & 174 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account. ------------------------------------------------------------------------- Note :- A sum of Rs. 970/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 40 (Schedule of Credit) of Tender documents.
M/S Shree Ram Enterprises
PACHAR BROTHERS
Gupta Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .