Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC GAWATIYAPARA SHIVNANDANPUR BISHRAMPUR DISTT SURAJPUR CHHATTISGARH 497226 | BISHRAMPUR | SURAJPUR | CHHATTISGARH | 497226 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical VILL KAZIYAPUR POST SURATGANJ TAHSHEEL RAMNAGAR KAZIYAPUR NEAR JHEEL LUCKNOW UTTAR PRADESH 227115 UDYAM UP 14 0003184 | 227115 | - | Rejected-Technical L4 | |
| 3 | Rejected-Technical ETTA BHATTA MAINROAD SURAJPUR BHATGAON SURAJPUR CHHATTISGARH | DURG | CHHATTISGARH | 490001 | - | Rejected-Technical L2 | |
| 4 | Rejected-Technical MISSION HOSPITAL CHOWK KEDARPUR AMBIKAPUR DIST SURGUJA CG 497001 | SURGUJA | CHHATTISGARH | 497001 | - | Rejected-Technical L3 |
Tender Value
₹8.7 L
EMD Value
₹10,900
Closing Date
11 Apr 2024, 10:00 amClosed
SO EnM, SECL BHATGAON AREA
OFFICE OF SO EnM, SECL BHATGAON AREA
Complete Electrical wiring in newly constructed hall beside Manoranjan Grih Building, Jarhi Bhatgaon Area
2024_SECL_306008_1
GM/Bhat/EM/e-open tender/2023-24/91 dated.28.03.24
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
SECL, BHATGAON AREA
Refer to NIT
8 documents required · 8 mandatory
₹10,900
19 Jun 2024
29 Mar 2024
12 Apr 2024
29 Mar 2024
11 Apr 2024
29 Mar 2024
29 Mar 2024 - 5 Apr 2024
Amount
Item Description/ Heading
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (12 Module (200mmX150mm)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (2 X 6 sq. mm + 1 X 6 sq. mm earth wire)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group A)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group B)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (5/6 amps switch)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (3 pin 5/6 amp socket outlet)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Providing & Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, as per instruction of Engineer in Charge. (Industrial Exhaust Fan, 450 mm sweep, 1400 RPM, 230V)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (6 way (4 + 18), Double door)
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required (100 A 16 KA)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required (100 A rating, 4 Pole (TPN), 30mA, RCCB ), 415 Volt
Providing & Installation of 400 millimeter Bracket mounted fan for Wall mounting in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, as per instruction of Engineer in Charge (400 millimeter Bracket mounted fan for Wall mounting, 230 V)
Supplying and fixing MCB Protected AC power socket including connections etc. as required, as per instruction of Engineer in Charge (25A, MCB Protected socket (AC Power socket)
Providing and fixing of LED light fitting 2'x2' , 36 Watt, 230 V as per instruction of Engineer in Charge.
Providing and fixing of LED Side lighter 3W as per instruction of Engineer in Charge. (LED Side lighter 3W, 230 V
Total impact of GST for the purpose of CTC
M/S UMASHREE ENGINEERING
MS R.P. JAISWAL
AJAY KUMAR SINGH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_317094.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .