Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹46.9 L+₹3.3 L (7.50%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹49.6 L+₹6.0 L (13.7%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹52.2 L+₹8.6 L (19.6%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹53.5 L+₹9.8 L (22.5%)Admitted-Finance REVENUE WARD 8 8 2 220 GANDLA STREET SULLURU SULLURPET NELLORE ANDHRA PRADESH 524121 | SPSR NELLORE | ANDHRA PRADESH | 524121 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | esquire electricals L3 | CHANDRA REDDY ELECTRICALS L5 | MSE CONTRACTOR L4 | GPK ELECTRICALS L2 | SRIRAM ELECTRICALS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supply, installation, testing and commissioning of the following LED Luminaires of suitable Wattage as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.16.0). | ||||||||
| 1.10 | Minimum lumen output of 4000 lm and minimum efficacy of 120 lm/w, 5700/6500 K, LED batten with CRCA/Steel/Extruded Aluminium housing, suitable for Ceiling, Wall and Downrod mounting. | 110 | Nos. | 2,372 ₹2,60,920 | 2,836 ₹3,11,960 | 2,200 ₹2,42,000 | 2,100 ₹2,31,000 Lowest | 2,325 ₹2,55,750 |
| 1.20 | Minimum lumen output of 2000 lm and minimum efficacy of 110 lm/w, 5700/6500 K, LED batten with CRCA/Steel/Extruded Aluminium housing, suitable for Ceiling, Wall and Downrod mounting. | 350 | Nos. | 2,071 ₹7,24,850 | 2,447 ₹8,56,450 | 2,000 ₹7,00,000 | 1,925 ₹6,73,750 Lowest | 2,050 ₹7,17,500 |
| 1.30 | Minimum lumen output of 1170 lm and minimum efficacy of 130 lm/w, 5700/6500 K, LED batten with extruded Aluminium housing, suitable for Ceiling and Wall mounting. | 80 | Nos. | 1,714 ₹1,37,120 | 1,668 ₹1,33,440 | 1,100 ₹88,000 Lowest | 1,550 ₹1,24,000 | 1,430 ₹1,14,400 |
| 1.40 | Minimum lumen output of 650 lm and minimum efficacy of 130 lm/w, 5700/6500 K, LED batten with extruded Aluminium housing, suitable for Ceiling and Wall mounting. | 20 | Nos. | 1,885 ₹37,700 | 1,027 ₹20,540 Lowest | 1,200 ₹24,000 | 1,250 ₹25,000 | 1,120 ₹22,400 |
| 1.50 | Minimum lumen output of 1320 lm and minimum efficacy of 110 lm/w, 5700/6500 K, LED downlight with pressure diecast Aluminium housing suitable for surface mounting. | 80 | Nos. | 1,314 ₹1,05,120 Lowest | 1,981 ₹1,58,480 | 1,600 ₹1,28,000 | 2,150 ₹1,72,000 | 2,200 ₹1,76,000 |
| 1.60 | Minimum lumen output of 1650 lm and minimum efficacy of 110 lm/w, 5700/6500 K, LED downlight with pressure diecast Aluminium housing, suitable for recessed mounting. | 30 | Nos. | 1,185 ₹35,550 Lowest | 1,675 ₹50,250 | 1,200 ₹36,000 | 1,820 ₹54,600 | 1,830 ₹54,900 |
| 1.70 | Minimum lumen output of 12000 lm and minimum efficacy of 120 lm/w, 5700 K, IP 66 grade LED flood light with pressure die cast Aluminium housing. | 5 | Nos. | 5,717 ₹28,585 Lowest | 10,359 ₹51,795 | 7,500 ₹37,500 | 6,300 ₹31,500 | 6,300 ₹31,500 |
| 1.80 | Minimum lumen output of 8400 lm and minimum efficacy of 120 lm/w, 5700 K, IP 66 grade LED flood light with pressure die cast Aluminium housing. | 3 | Nos. | 4,930 ₹14,790 | 8,305 ₹24,915 | 4,000 ₹12,000 | 5,000 ₹15,000 | 3,300 ₹9,900 Lowest |
| 1.90 | Water proof, IP 65 grade mounting frame with PC housing and PC cover, suitable for 2x18/20 W LED Tube. Note: Required LED Tube will be issued at free of cost by the Department. | 20 | Nos. | 2,400 ₹48,000 | 2,048 ₹40,960 Lowest | 3,500 ₹70,000 | 2,300 ₹46,000 | 2,300 ₹46,000 |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
17 Sept 2025, 3:00 pmClosed
Chief Engineer, CEG,GSO
Room No. 306, GSO Annex building, Kalpakkam - 603102
Providing lightning protection to schools buildings and improvement of indoor lighting
2025_GSO_874565_1
GSO/CTC/ESD/211/2025
Open Tender
Electrical Works
Item Rate
270 days
DAE Township, Kalpakkam
As stipulated in NIT/tender
8 documents required · 8 mandatory
₹0
₹1.1 L
7 Nov 2025
26 Aug 2025
18 Sept 2025
26 Aug 2025
17 Sept 2025
12 Sept 2025
27 Aug 2025 - 9 Sept 2025
Amount
Supply, installation, testing and commissioning of the following LED Luminaires of suitable Wattage as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.16.0).
Minimum lumen output of 4000 lm and minimum efficacy of 120 lm/w, 5700/6500 K, LED batten with CRCA/Steel/Extruded Aluminium housing, suitable for Ceiling, Wall and Downrod mounting.
Minimum lumen output of 2000 lm and minimum efficacy of 110 lm/w, 5700/6500 K, LED batten with CRCA/Steel/Extruded Aluminium housing, suitable for Ceiling, Wall and Downrod mounting.
Minimum lumen output of 1170 lm and minimum efficacy of 130 lm/w, 5700/6500 K, LED batten with extruded Aluminium housing, suitable for Ceiling and Wall mounting.
Minimum lumen output of 650 lm and minimum efficacy of 130 lm/w, 5700/6500 K, LED batten with extruded Aluminium housing, suitable for Ceiling and Wall mounting.
Minimum lumen output of 1320 lm and minimum efficacy of 110 lm/w, 5700/6500 K, LED downlight with pressure diecast Aluminium housing suitable for surface mounting.
Minimum lumen output of 1650 lm and minimum efficacy of 110 lm/w, 5700/6500 K, LED downlight with pressure diecast Aluminium housing, suitable for recessed mounting.
Minimum lumen output of 12000 lm and minimum efficacy of 120 lm/w, 5700 K, IP 66 grade LED flood light with pressure die cast Aluminium housing.
Minimum lumen output of 8400 lm and minimum efficacy of 120 lm/w, 5700 K, IP 66 grade LED flood light with pressure die cast Aluminium housing.
Water proof, IP 65 grade mounting frame with PC housing and PC cover, suitable for 2x18/20 W LED Tube. Note: Required LED Tube will be issued at free of cost by the Department.
Removal of light fixtures as per the detailed scope of work and as directed by the Engineer-in-charge.
Removal of light fixtures in low bay areas.
Removal of light fixtures in high bay areas
Supply and installation of Hylam sheet covers for MS/Wooden Switch Boxes/ JBs as per the detailed specification and as directed by the Engineer-in-charge.
Supply, installation and testing of GI Pipe Earth Electrode as per IS: 3043 including RCC Chamber and RCC cover slab as per Drawing Nos. IGC/ESD/5060/1007/1 & IGC/ESD/5060/1008/1 are enclosed. (50 Kg. Each Bentonite & Charcoal shall be provided for each earth pit). (Refer Sec VI, Clause No.12.4).
Supply, fabrication and installation of the following size of Hot dip Galvanised GI Flats including excavation and refilling as per the detailed specification. No cutting or drilling permitted after galvanisation.(Refer Sec VI, Clause No.12.9).
25 x 6 mm GI flat
Supply, fabrication and installation of the following size of Hot dip Galvanised GI Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. No cutting or drilling permitted after galvanisation. (Refer Sec VI, Clause No.12.9).
25 x 6 mm GI flat
Supply and fixing of 300 mm long Lightning Air Termination made out of 25mm GI Rod welded with 125 x 125 x 10mm GI Base Plate including supply of 4 Nos. of M10 stainless steel bolts, nuts and washers as per the detailed specification.
Supply and installation of 1 mm thickness, 5 Feet x 4 Feet, Matt finish,stainless steel engraved name board, as per the detailed specification and as directed by Engineer-In-Charge.
Plain Cement Concrete.(Refer Sec VI, Clause No.26)
1:2:4 Plain Cement Concrete
Providing and fixing double scaffolding system (cup lock type) on the exterior side at all height made with 40mm diameter M.S. tube spaced @ 1.5m center to center at both horizontal and vertical tubes, joining with cup and lock system with M.S.tube, M.S.tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners connection with the building, etc., Wherever required for the inspection of work at required location with essential safety features for the workmen, etc., complete as per directions and approval of Engineer-in-charge.(Note: The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.)
GPK ELECTRICALS (BID ID -3283653)
esquire electricals (BID ID -3282139)
MSE CONTRACTOR (BID ID -3283046)
CHANDRA REDDY ELECTRICALS (BID ID -3283908)
Bidder Name
CHANDRA REDDY ELECTRICALS
esquire electricals
MSE CONTRACTOR
GPK ELECTRICALS
SRIRAM ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .