| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹24.7 L+₹4.3 L (20.9%)Rejected-AOC | L2 | Rejected-AOC other than L1 |
| Sl No | Description | Qty | Unit | SHSS ASSOCIATES L2 | M/S AKHILESHWAR ASSOCIATES L1 |
|---|---|---|---|---|---|
| 1.00 | LED street light fitting 70 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and directed | 66 | Each | 3,250 ₹2,14,500 | 2,000 ₹1,32,000 Lowest |
| 2.00 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 25 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. | 2,300 | RM | 235 ₹5,40,500 | 220 ₹5,06,000 Lowest |
| 3.00 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. | 70 | RM | 370 ₹25,900 | 300 ₹21,000 Lowest |
| 4.00 | Supply and fixing weather proof flat three Core PVC insulated & sheathed Copper stranded conductor cables 1.5 sqmm drawn through street light pole duly making the hole upper and down both place and connecting the street light to DB Box all as specified and directed. | 660 | RM | 55 ₹36,300 Lowest | 85 ₹56,100 |
| 5.00 | 15mm bore light grade GI tubing for protection to cable including fixing along pipe, along pole complete all as specified and directed. | 396 | RM | 160 ₹63,360 | 100 ₹39,600 Lowest |
| 6.00 | Street light bracket made out of MS angle 40mm X 5mm, 1.5 meter long and both end hole for fixing of street light incl MS Clamps, back plates fabricated from structural steel scetion 50 x 6mm, including nuts, bolts, washers welding cold or hot, drilling of holes for bolts, in any shape or size including two coats of Aluminium paint over a coat of Red Oxide primer after preparation of steel surfaces complete all as specified and directed. | 66 | Each | 450 ₹29,700 Lowest | 600 ₹39,600 |
| 7.00 | Loop In and Loop Out Box pole mounted out door type Hot press Moulded SMC Junction Box of inside dimension not less than 300x200x150mm with locking arrangement suitable for 240 V, 50 Hz including MCB SP of 6 Amp cap, fixing with 4 Nos Aluminium busbar of 06 Amp rating for Three/single phase with neutral, painted with powder coating in siemens grey colour including clamp for fixing with steel pole all as specified and directed. | 66 | Each | 1,500 ₹99,000 | 900 ₹59,400 Lowest |
| 8.00 | S&F in replacement 40mm bore tube 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable complete all as specified and directed. | 102 | RM | 300 ₹30,600 Lowest | 300 ₹30,600 Lowest |
| 9.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying cable including getting out in any type soil complete all as specified and directed. | 510 | Cum | 130 ₹66,300 Lowest | 190 ₹96,900 |
| 10.00 | Returning filling in including spreading watering and well ramming in layers not exc 25 cm complete all as specified. | 305 | Cum | 20 ₹6,100 Lowest | 80 ₹24,400 |
Tender Value
₹29.9 L
EMD Value
₹60,000
Closing Date
18 Dec 2025, 6:00 pmClosed
GE (N) Akhnoor
GE (N) Akhnoor C/O 56 APO PIN-181201
REPLACEMENT OF EXISTING SECURITY LIGHT CABLE AT FD WKSP COY EME AND SPL REPAIR REPLACEMENT OF AC PLANT AT SHOOTING NODE AND COLD STORAGE ROOM UNDER GE N AKHNOOR
2025_MES_741735_1
GE(N)/AKH-53/2025-26
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
Class D Cat b i
8 documents required · 8 mandatory
₹500
GE (N) Akhnoor
₹60,000
Yes
11 Feb 2026
27 Nov 2025
25 Dec 2025
27 Nov 2025
18 Dec 2025
11 Dec 2025
Amount
LED street light fitting 70 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and directed
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 25 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Supply and fixing weather proof flat three Core PVC insulated & sheathed Copper stranded conductor cables 1.5 sqmm drawn through street light pole duly making the hole upper and down both place and connecting the street light to DB Box all as specified and directed.
15mm bore light grade GI tubing for protection to cable including fixing along pipe, along pole complete all as specified and directed.
Street light bracket made out of MS angle 40mm X 5mm, 1.5 meter long and both end hole for fixing of street light incl MS Clamps, back plates fabricated from structural steel scetion 50 x 6mm, including nuts, bolts, washers welding cold or hot, drilling of holes for bolts, in any shape or size including two coats of Aluminium paint over a coat of Red Oxide primer after preparation of steel surfaces complete all as specified and directed.
Loop In and Loop Out Box pole mounted out door type Hot press Moulded SMC Junction Box of inside dimension not less than 300x200x150mm with locking arrangement suitable for 240 V, 50 Hz including MCB SP of 6 Amp cap, fixing with 4 Nos Aluminium busbar of 06 Amp rating for Three/single phase with neutral, painted with powder coating in siemens grey colour including clamp for fixing with steel pole all as specified and directed.
S&F in replacement 40mm bore tube 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying cable including getting out in any type soil complete all as specified and directed.
Returning filling in including spreading watering and well ramming in layers not exc 25 cm complete all as specified.
Removing surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
Protection to cable with one layer of brick laid flat across the cable using old size sub class 'B' Bricks all as specified an directed.
Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying and stretching the cable in trenches including hand punning and consolidating, punned to 18cm thickness, complete all as specified and directed. Note : For payment purpose, only punned thickness shall be measured.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised earth wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45cm x 45cm x 45 cm,RCC cover 1:2:4 type B1 of size 45x45x6 cm, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. Note:- The required resistance of Earthing shall be less than 3 ohm, If not found to the required resisstance, the contractor has to re earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
Testing after complete servicing, cleaning and repairing of microprocessor controlled air cooled scroll chiller 48 TR capacity (2 Nos Each) with energy efficient scroll compressor complete having facility of digital setting of temp levels, built in time relay and restoration after testing all electrical connection with the help of lugs from control box to AHU complete as per satisfaction of the Engr-in-charge all as specified and directed. Note 1:- All items which are required for connection and servicing ( i.e MCB, copper cable) are deemed to be included in quoted rate only Note 2:- After complete servicing and repairing, functionality check of plant and AHU will be done in presence of Engr-in-charge for both hot and cold operation.
Compressor Gas (R-407C/R-410A/R-134A/R507/R-22/R-32) all as specified and directed.
Capilliary tubing and removing existing tubing all as specified and directed.
Replacement of old MS duct insulation and repair of any leakage in chiller/AHU duct all as specified and directed.
Replacement of old/ damage MS duct of AHU/chiller duct all as specified and directed.
TEV ( Thermal expansion valve) all as specified and directed.
Replacement of fan motor and condenser fan of AHU all as specified and directed.
Connector (MX-32) of AC plant in control box and rewiring of control box all as specified and directed.
Servicing and repairing of AHU unit and replacement of AHU filter also maintenance and servicing for louvers for fresh air after cleaning all as specified and directed.
Servicing, testing and cleaning of Cold storage room of size 18X11X8 feet with compressor unit ( Make: Blue star) after detecting the leakage of gas and repair and refixing after servicing, changing the filter and dryer and changing the relay all as specified and directed.
Running capacitor suitable for cold storage room as approved all as specified and directed.
Compressor (12 TR capacity) of AC plant for existing make ( danfoss commercial compressors) Model No:- SZ185S4RC having voltage range (380-400 V at 50 Hz frequency) and thermally protected or its equivalent in Carrier, Voltas, Kirloskar suitable for existing AC Plant as approved all as specified and directed.
Thermocol for cold storage room all as specified and directed.
Compressor for cold storage room of capacity 3 TR as per existing make or its equivalent in Carrier, Voltas, Kirloskar as approved complete all as specified and directed.
Servicing and repairing of outdoor unit, axle fan (12 inch) for cold storage room complete to make it fully functional to the satisfaction of Engr-in-charge all as specified and directed.
Strip heater of capacity 8-10 KW of cold storage room all as specified and directed.
SHSS ASSOCIATES (BID ID -3498260)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tender53.pdf
Tender Documents • 1.09 MB
BOQ_830578.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .