SPECIAL REPAIR TO SEWAGE TREATMENT PLANT (STP) IN THE PREMISES OF AT CGDA HQRS, DELHI CANTT.
2020_DRDO_594546_1
CCE(RD)N/DAD/MAJ/ENQI(R2/20-21
Limited
Miscellaneous Works
Item Rate
120 days
HQ CGDA, DELHI CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
CHIEF CONSTRUCTION ENGINEER(RnD) NORTH
₹14,110
Yes
2 Dec 2020
3 Nov 2020
16 Nov 2020
4 Nov 2020
13 Nov 2020
5 Nov 2020
Amount
Dismantling of old FCD and Supply, Installation, Testing - Commissioning of new Flow Control Device (FCD) for control of 2000 LPH External capacity in let flow. The device shall be consisted for accessive flow return to main source of inflow. The MOC of FCD shall be MS internally fibre re-inforced complete with nozzles, leg supports and accessories complete with external 2 coats of epoxy paint over anticorrossive red oxide primer for smooth operation of sewage treatment plant and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Supply, installation, testing & commissioning of twin lobe type rotary air blower driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP operated on 415 ± 10% volts, 3 phase, 50 cycles, A/C supply.suitable for delivering 74cum/hr free air at 0.5kg / cm2 / user and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Supply, installation, testing & commissioning of fine bubble air diffusers complete with jointers and necessary fittings as required.for smooth operation and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Dismentalling of old unused / damaged air pipe line and Providing, fixing and recommissioning of new air turbine (Partly) where as required, including pipe line for connecting of new standby air blower. The Pipe line shall be comprising of UPVC pipe droppers with laterals and M S Header complete in all respect including required fittings like tee, crosses, plugs, sockets, elbows, reducers, supports, Clamps and flanges etc. complete.
Supply, installation, testing & commissioning of coarse air diffusers in equalization tank and sludge holding tank for providing proper mixing and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Supply , installation, testing and commissioning of high surface area ring type media for smooth functioning of STP. The specification of media shall be as follows: Type : Ring type Random Bio-Pac Media (Semi-clog) and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent. M.O.C : Virgin PP with UV stabilisation for high resistance to erosion and chemical attack Structure : Self supporting cylindrical shape ,Black in colour with internal ribs and concentric circular sections. Size : 22mm (L) X 22mm (Dia) Sp. Wt. : 0.37 kg/m2 S.A Density : 0.93 Percentage fill of Volume : 45 to 60 % Voidage : >95%
Supply, Installation, testing and commissioning of UPVC Tube deck Settling Media for the proper functioning of STP plants having the characteristics as follows :- Type : Tub-Pac Media, Make : as per direction of Engineer -in-charge or equevalent. M.O.C : Virgin PPVC with UV stabilisation for high resistance to erosion and chemical attack , Structure : Self supporting Hexagonal Chevron shaped, Length : 750mm, Laying Angle : 60 deg. From Horizental,Working Temprature : 55deg.C. , Fitting Arrangement : Tongue & Groove.
Dismentling of existing pumps and Supply, Installation , testing and commissioning of single stage horizental centrifugal self priming pump with C.I body, Bronze impeller, EN-8 shaft and delivery casing in C.I with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with base frame bolted to existing cement concrete foundations complete as per following :
Sludge Transfer Pump - (Pumps to be suitable to handle Solid handling upto 7 mm size) - Capacity - 2 M3/Hr - Head - 10.0 Mtr. and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Supply, installation, testing & commissioning of metering pump type chemical doser with 100 lits. PVC/HDPE solution tank, injection fitting assembly, suction and delivery hose upto the point of injection, capacity 0-4 lph, complete in all respects and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Supply, Installation, Testing & Commissioning of water proof Electronic contact Type Float Control Switches to synchronise water level for auto level controlled operation for entire Water treatment Plant and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Dismentling of old relay tank and Supply, Installation and commissioning of new Relay Tank of MOC : HDPE, Capacity : 1000 Ltr. and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Dismentling of old A - 42 V belt of existing air blower and re- fixing the new belt including servicing of blower like greasing, Servo - 90 - Oil refil, air filter, supply and fixing of new oil filled analog type 4"dial x 3/8" Pressure Indicator, nut bolts etc. as required for smooth operation of the system..
Dismentling of existing unused / damaged pipe fittings / connectors etc. of existing pumps including nut bolts, rubber gaskets, pump glands and replacement of these with new items including oiling, greasing of pumps,pressure indicators etc for smooth operation of existing sewage treatment plant-complete
Supplying and laying the PVC insulated & sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor including supplying and making and termination with brass compression glands:
3 Core x 4 Sq.mm and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Dismantling / Repair / Re-Installation and recommissioning of Existing Dual Media Filter having the capacity of 2000 LPH and dia of 350 mm & HOS : 1500 mm, MOC: MSEC.. The old and discharged media of this existing DMF would be thrown away and recharged with fresh media. The vessel would be repainted /repaired. Thel destroyed nut-bolts,packings/internal collection and distribution /defusers system would be repaired/re-commissioned for smooth operation and for the satisfaction of Engineer In-charge.
Repair of existing MS Fabricated sewage plant by using of new MS sheets,ISA:25/40/50(where as required) and internal fibre re-enforcement / 2 coats of Epoxy paint (where as required) for smooth operation of plant and for the satisfaction of Engineer In-Charge.
Supply of following operating chemicals for recommissioning of STP plant
Biocid / Bionit and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Flocazol / Amalgazol and satisfaction of Engineer In-Charge / User. Make : as per existing setup or equivalent.
Sodium Hypo-Chlorite
Credit for following items on as is where is basis :-
Air diffuser
UPVC Pipe fitting including Tee, Socket, Bends etc. all complete.
Flow control device
Single stage horizentel sludge transfer pump
Chemical dozing pump
Float control switch
1000 ltrs syntex tank
Scrap of MS sheet / angle iron MS chennel etc. complete
SYSTEMS ASSOCIATE
Santosh & Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .