Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.0 CrAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹2.0 Cr+₹5.9 L (2.97%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹2.4 Cr+₹40.6 L (20.5%)Admitted-Finance 1464 1 GURUDWARA ROAD KOTLA MUBARAKPUR NEW DELHI 110003 | NEW DELHI | NEW DELHI | DELHI | 110003 | L3 | Admitted-Finance | ||
| 4 | Rejected-Technical 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | - | Rejected-Technical Due to Turnover Profit loss and Networth not uploaded | ||
| 5 | Rejected-Technical 1774 AMAN COLONY DHANAS CHANDIGARH DHANAS DHANAS CHANDIGARH CHANDIGARH 160014 | CHANDIGARH | CHANDIGARH | 160014 | - | Rejected-Technical Due to enlistment limit |
Tender Value
₹2.4 Cr
Closing Date
8 Nov 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Hospital Engineer (Elect.), PGIMER Chandigarh
Hospital Engineer (Elect.), PGIMER Chandigarh
Modernisation of Research Block A and B at PGIMER, Chandigarh. Electrical Works Floor Panels
2021_PGIME_653413_1
PGI/Engg./Elect./2021/28
Open Tender
Electrical Works
Percentage
365 days
Hospital Engineer (Elect.), PGIMER Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
24 Nov 2021
19 Oct 2021
9 Nov 2021
19 Oct 2021
8 Nov 2021
19 Oct 2021
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Sub Head -I : Electrical Work | |||||
| 1.01 | Supply Erection, Testing and Commissioning of Cubical Type Totally enclosed single door dust and vermin proof ingress protection IP-54 Floor Mounted TTA Switchboard with Hinged Lockable Doors fabricated out of 14SWG CRCA Sheet with Powder Coating through 7 tank process with all accessories live parts shrouded and busbars insulated with heat shrinkable sleeves including solid/flexible connections, earthing etc., having 3mm thickness Gland Plate. LT Panel should have withstand fault level of equal to 50 KA for 1 second. Electrical standard complying -IEC-61439-1&2 and RAL 7032. Fitted with gaskets, Lifting Hooks, Cable Entry Top, Approx. size: 1700mm(W) x 440mm(D) x 2475mm(H), The solid insulated bus bar shall be of Aluminium conductor with Color Coded Tag Block Heat Shrinkable PVC Sleeves LT panel comprising of the following:- INCOMING:- Feeder 1 and 2:- 250A 4 Pole 36KA Motorized MCCB with Microprocessor Based Release having LSIG Protection and on-off -trip indication . Ics=100%Icu: 1 No. each Spreader Terminals Auxiliary + Alarm Contact Block Auxiliary Contactor 2NO+2NC R,Y,B Phase Indication lamps LED Type MCB 6A SP 10KA "C" Curve, Outgoing Feeder Bus Section-1 : 63A , 25 KA TP Thermal magnetic, MCCB Feeder, with Adj. O/L and adj. S/C protection : 12 nos , Outgoing Feeder Bus Section 2: 20A, 25 KA TP Thermal magnetic, MCCB Feeder, with Adj. O/L and adj. S/C protection : 4 nos, Bus Bar: 250 Amp TPN, 300 Sqmm Aluminium busbar and horizontal and vertical busbar as per load with color coded heat shrinkable sleeves and SMC support insulators. RYB 1x50mmx6mm, Neutral 1x50mm x 6mm Earthing: 1x50mm x 6mm, Automatic Transfer controller : 1 No. controller for automatic control of both the incomer MCCB with auto manual selector switch. The controller will facilitate auto switching on pre defined Source-1 even when the other Source-2 is available. further, in absence of either Source, the supply will be switched on to the other available Source automatically.Metering: Bus Section 2: Light Feeder: Digital multifunction meter CL 1.0 with RS485, CT CL 1.0 100/5, 10VA, CTTB Connections by copper flexible wire: for 63 A MCCB: min. 16 sqmm; for 20 A MCCB: min. 6 sqmm The drawing of the panel to be got approved before fabrication by Engineer Incharge. | 24 | Nos | 4,56,909 | ₹1,09,65,816 |
| 2Rising Mains: Supplying, installing , mounting on wall, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. | |||||
| 2.01 | 400 A 30kA SC for 1 sec | 100 | Mtr. | 12,022 | ₹12,02,200 |
| 2.02 | 630 A 50kA SC for 1 sec | 200 | Mtr. | 13,833 | ₹27,66,600 |
| 2.03 | Supplying, installation, testing & commissioning of following capacity End Feed Unit for the existing rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 400 A 30kA SC for 1 sec | 4 | Nos | 7,307 | ₹29,228 |
| 2.04 | 630 A 50kA SC for 1 sec | 8 | Nos | 9,344 | ₹74,752 |
| 2.05 | Supplying, installation, testing & commissioning of following capacity Plug In/ tap off box on the existing rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required 125 A 15kA SC for 1 sec | 24 | Nos | 6,358 | ₹1,52,592 |
| 2.06 | 200 A 25kA SC for 1 sec | 48 | Nos | 8,048 | ₹3,86,304 |
| 3Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.30 MB
Tendernotice_1.pdf
Tender Document • 5.30 MB
BOQ_687820.xls
BOQ • 0.40 MB
BOQ_687820.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .