| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.1 LAccepted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 1 | Accepted-Finance being L1 | |
| 2 | 2₹26.2 L+₹18,718.50 (0.72%)Rejected-Finance | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹26.6 L+₹52,276.50 (2.01%)Rejected-Finance | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹26.9 L+₹83,701 (3.21%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹27.4 L+₹1.3 L (4.99%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹45.1 L
EMD Value
₹90,300
Closing Date
24 Sept 2024, 6:00 pmClosed
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT-10
SPECIAL REPAIR REPLACEMENT OF UNDERGROUND ELECTRIC CABLES IN UNIT AREA OF 512 LIGHT AD MSL REGT SP AND SPL REPAIR TO LT CABLE FOR STREET LIGHTS AND CONNECTED ITEMS AT DIPAC IN THE AREA OF AGE U ES NO 1 UNDER GE U ELECT SUPPLY DELHI CANTT 10
2024_MES_669745_1
GE ELEC/D-37/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY ELEC SUPPLY
₹90,300
Yes
7 Nov 2024
2 Sept 2024
25 Sept 2024
2 Sept 2024
24 Sept 2024
16 Sept 2024
Amount
Dismantling of MS channel or Angle iron or flat iron sections from LT/HT poles complete all as specified and directed by Engr-in-Charge.
Dismantling of insulators of any type and any size from RCC/PCC LT/HT poles complete all as specified and directed by Engr-in-Charge.
Dismantling carefully Old unserviceable ACSR conductor / jumper from LT/HT Poles complete all as specified and directed by Engr-in-Charge.
Dismantling & Removing carefully Old unserviceable LT cables/ Service cable of size 16 sqmm to 35 sqmm from LT Pole to MCB DB complete all as specified and directed by Engr-in-Charge.
Dismantling of of any type 2/4/6 pole structure complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by the Engg--in Charge of the following sizes:- Note :- 1. Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. 2. LT cable of size :-16 sqmm:- 800 rm 25 sqmm-1800 Rm,35sqmm-1500 Rm,50 sqmm-500Rm & 95 Sqmm-300 Rm Consider against Replacement of Old Damaged Cables
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core
50 Sq mm 3.5 core
95 Sqmm 3.5 core
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level complete all as specified and directed by Engr-in-Charge.
Returning filling in, Including spreading, leveling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated material (i.e. soil) from site to a distance n. exec 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc. complete all as specified and directed by Engr –in-charge. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 12 here-in-before but using old bricks complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.1 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized ironsides complete all as specified, including testing and commissioning complete all as specified and directed by Engr-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe up to 7.5 meter beyond the earth plates electrode.
S&F in replacement of KIOSK box weather proof made out of PVC, one piece molded SMC base and out door pole mounted hinged door size 333 x 233 x 120 mm out side and 300 x 200 x 105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 6 Amp MCB SP with base for controlling the street light, FI clamps 30x4 mm with necessary MS nuts bolts and washers including embossing/painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed by Engineer-in-Charge.
Supply drawing, connecting and testing in replacement of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting and flood light including providing suitable copper lugs complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED street light Fitting 70 watt LED, IP-66 protection, single piece pressure die cast aluminum housing high grade powder coated finish with heat resistant toughened clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable along with GI pipe bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts, bolts and washers and painting on steel surfaces with two coats of aluminum paint complete all as specified and directed by Engr-in-Charge.
S&F in replacement bracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts, bolts and washers and painting on steel surfaces with two coats of aluminum paint over a coat of primer complete all as specified and directed by Engr-in-Charge.
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of HDPE/GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engr-in-Charge.
Supply and laying of HDPE pipe suitable for 5 kgf/cm 2 working pressure with all fitting , laid in trenches for protection of cable in road /drain crossing or similar works complete all as specified and directed by Engineer-in-Charge, of following sizes:-
40 mm dia
50 mm dia
80 mm dia
Platform :- M&L for Brick Masonry ( Using sub class 'B' Brick) platform of size 3m x 3m x 1 m height , built in CM 1:4 complete with excavation & earth work , PCC 1:4:8 type D-2 in foundation , 15 mm thick rendering in CM 1:6 on sides and top of the brick work , up to 150 mm below ground level , supply and fixing of 02 Nos MS Channels of size ISMC-100 for balancing of Transformer embedded in PCC 1:2:4 type B-1 up to 100 mm Thick RCC 1:2:4 with 10 mm steel bar including 20 mm graded aggregate , including provn of steps on one side complete all as specified and directed by Engr-in-Charge.
Disconnecting electrically and mechanically outdoor transformers up to 400 KVA capacity, lowering down from 4/6/8 pole structure carefully using hydra machine and Re-installation of transformer on plinth, connecting electrically and mechanically, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Fencing :- M&L for perimeter fencing of size 04m x 04m x 2m (as per site condition) having MS work of angle iron for post and struts of fencing around the transformer plinth/substation/LT panels etc drilling holes flat iron fillet for securing wire mess by welding to angle iron frame and framed work as in door/gate of angle iron and wiremesh.Door to be fixed by 03 nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified and directed by Engr-in-Charge. Consisting of the following:- (a) Angle iron post to post distance maintained not more than 02mtr ,size of angle shall be 40x40x5mm.Angle Iron shall be embedded in natural ground not less than 0.90 m deep. (b) MS wire 75x75mm mesh 3.15 mm dia ,2mtr height and shall be fixed to post with flat iron 32 x 6 mm fillet with two coats of synthetic enamel paint over a coat of red oxide primer. (c)Cement concrete type D-2 ,1:4:8 using grade crushed stone aggregate for mass concrete/ foundation. (d) Brickwork with subclass 'B ' bricks ,straights or curved on plane exc 6m mean radius ,built in cement mortar 1:6 complete for toe wall along the perimeter fencing. The toe wall shall be one brick thick,30cm high (15cm above GL and 15cm below GL) on 75mm thick PCC lean concrete. (e) The exposed surfaces of brickwork shall be rendered 15mm thick in CM (1:4) finished fair and even without using extra cement. (f) The steel gate shall be of size 1.00m x2.00 m fabricated from angle iron 40x40x5 mm frame and 12x12 mm square guard bars. (g) All the exposed surfaces of steel shall be painted with two coats of Synthetic enamel paint over one coat of Red Oxide Primer. (h) Dry stone aggregate of size 40mm spreaded ,leveled & compacted up to 100mm thick. (h) Necessary excavation and earthwork shall be included in the quoted rate.
S&F in replacement of Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 LED flood light suitable for high lighiting architectural façade and general purpose lighiting of capacity 200 Watt LED complete all as specified and directed by Engr-in-Charge.
Disconnecting LT Supply from timer panel of High mast lowering down the mast fitting for repair, fixing of LED flood lights and raising up in the the original position complete all as specified and directed by Engr-in-Charge.
S&F in replacement stainless steel rope 6mm dia for lowering down of High mast fitting complete all as specified and directed by Engr-in-Charge.
S&F D clamp including nut bolt and washers etc for high mast ligth fittings complete all as specified and directed by Engr-in-Charge.
S&F in replacement 6 Sqmm 5 Core flexible copper cable incl making necessary connections complete all as specified and directed by Engr-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
Microsys Controls India (BID ID -3111518)
M/s JAIMAA ASSOCIATES (BID ID -3111213)
Vijay Electricals (BID ID -3107942)
Commercial Traders (BID ID -3111505)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3108273)
P S TRADERS (BID ID -3110772)
Rajindera Enterprises (BID ID -3109850)
Ridhi engineers and builders (BID ID -3111733)
MV Engineers And Contractors (BID ID -3100070)
M/S Rohit Enterprises (BID ID -3111435)
DS CONSTRUCTION (BID ID -3106984)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .