| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC | ₹15.4 L Quoted ₹13.6 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹17.8 LRejected-AOC | ₹17.8 L | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹23.1 LRejected-AOC PLOT NO 41 T H ROAD KESAVAPURAM MINJUR 601 203 | THIRUVALLUR | TAMIL NADU | 601203 | ₹23.1 L | L3 | Rejected-AOC L3 Bidder |
| Sl No | Description | Qty | Unit | SHARTHI TECKMA CONTRACTS L3 | SRI RAVI BALAJI ERECTORS L1 | SS ELECTRONICS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Charges for setting of open/close limit, open/close torque limit switches, replacing defective electronic cards and motor (Up to 3.7kW), checking of control & power circuits, as instructed by Maintenance Engineer in charge. (Including consumables and T&P items) | 300 | Nos | 1,800 ₹5.4 L | 1,000 ₹3 L | 1,407 ₹4.2 L |
| 2.00 | Charges for cleaning of motorized actuators and covering with polyethylene cover with proper tie arrangement in order to avoid water and dust entry inside the actuators. (Including consumables and T&P items) | 1,476 | Nos | 300 ₹4.4 L | 165 ₹2.4 L | 214 ₹3.2 L |
| 3.00 | Charges for testing of protection relays and attending defects, replacing defective Relays, transducers and meters, CT terminal tightness checking in 11 KV, 3.3KV, 415 V switchgear panels as instructed by Maintenance Engineer in charge. (Including consumables and T&P items) | 40 | Nos | 1,500 ₹60,000 | 700 ₹28,000 | 978 ₹39,120 |
| 4.00 | Charges for checking control circuits, replacing defective relays, transducers, meters, CT & VT terminal tightness checking and attending defects reported by operator in control panels like GRP, DAVR, BTS, RTCC, ECP, DATA Concentrator, DG Set, TDBFP EOP, Main turbine EOP, testing of relays in GRP panel as instructed by Maintenance Engineer in charge. (Including consumables and T&P items) | 60 | Nos | 2,500 ₹1.5 L | 1,500 ₹90,000 | 1,957 ₹1.2 L |
| 5.00 | Charges for cleaning GRP, DAVR, BTS, RTCC, ECP, DATA Concentrator, TDBFP and Main Turbine EOP Panels and relay compartments in 11KV, 3.3 KV, 415 V Switchgear panels. (Including consumables and T&P items) | 480 | Nos | 200 ₹96,000 | 60 ₹28,800 | 85 ₹40,800 |
| 6.00 | Charges for light up works, which includes checking the healthiness of protective equipment, ensuring the permissive for pre-synchronization and post synchronization, as instructed by Maintenance Engineer in charge. (Including consumables and T&P items) | 20 | Nos | 2,000 ₹40,000 | 1,250 ₹25,000 | 1,715 ₹34,300 |
| 7.00 | Charges for attending defects in Thyristor Bridges, Blowers, Control and LCI panels, replacing defective electronic modules, relays, Thyristor Bridges, timers, power & auxiliary contactors, checking of control circuits and terminal tightness of ID Fan VFD control. (Including consumables and T&P items) | 60 | Nos | 3,000 ₹1.8 L | 2,000 ₹1.2 L | 2,815 ₹1.7 L |
| 8.00 | Charges for cleaning of Thyristor Bridges, Blowers, Control and LCI panels of ID fan VFD. (Including consumables and T&P items).
Cleaning of 22 Nos panel/Shift= One operation. i.e., total operations= 60. | 60 | Nos | 2,500 ₹1.5 L | 1,500 ₹90,000 | 1,957 ₹1.2 L |
| 9.00 | Charges for daily walk down to 11KV, 3.3 KV, 415V switchgears, incomers and bus coupler panels, GRP, DAVR, VFD to check the healthiness of relay, meters and record the electrical parameters. (Including consumables and T&P items) | 360 | Opn | 1,800 ₹6.5 L | 1,200 ₹4.3 L | 1,460 ₹5.3 L |
Tender Value
Refer Docs
EMD Value
₹16,900
Closing Date
16 Feb 2026, 2:00 pmClosed
SEES NCTPS2
OFFICE OF SE ES NCTPS II
S.71 NCTPSII ES Circle MRT Division SDn III Unit II Generator, Turbine and Boiler areas and their Auxiliaries contract works for the Routine Maintenance of MRT equipment for a period of 360 Days Including Sundays All Government Holidays
2026_EB_650037_1
CE NCTPS II SE ES Spec No 71 2025 26
Open Tender
Electrical and Maintenance Works
360 days
NCTPS2
AS PER TENDER SPECIFICATION
2 documents required · 2 mandatory
₹0
₹16,900
Yes
11 May 2026
2 Feb 2026
17 Feb 2026
2 Feb 2026
16 Feb 2026
2 Feb 2026
Charges for setting of open/close limit, open/close torque limit switches, replacing defective electronic cards and motor (Up to 3.7kW), checking of control & power circuits, as instructed by Maintenance Engineer in charge. (Including consumables and T&P items)
Charges for cleaning of motorized actuators and covering with polyethylene cover with proper tie arrangement in order to avoid water and dust entry inside the actuators. (Including consumables and T&P items)
Charges for testing of protection relays and attending defects, replacing defective Relays, transducers and meters, CT terminal tightness checking in 11 KV, 3.3KV, 415 V switchgear panels as instructed by Maintenance Engineer in charge. (Including consumables and T&P items)
Charges for checking control circuits, replacing defective relays, transducers, meters, CT & VT terminal tightness checking and attending defects reported by operator in control panels like GRP, DAVR, BTS, RTCC, ECP, DATA Concentrator, DG Set, TDBFP EOP, Main turbine EOP, testing of relays in GRP panel as instructed by Maintenance Engineer in charge. (Including consumables and T&P items)
Charges for cleaning GRP, DAVR, BTS, RTCC, ECP, DATA Concentrator, TDBFP and Main Turbine EOP Panels and relay compartments in 11KV, 3.3 KV, 415 V Switchgear panels. (Including consumables and T&P items)
Charges for light up works, which includes checking the healthiness of protective equipment, ensuring the permissive for pre-synchronization and post synchronization, as instructed by Maintenance Engineer in charge. (Including consumables and T&P items)
Charges for attending defects in Thyristor Bridges, Blowers, Control and LCI panels, replacing defective electronic modules, relays, Thyristor Bridges, timers, power & auxiliary contactors, checking of control circuits and terminal tightness of ID Fan VFD control. (Including consumables and T&P items)
Charges for cleaning of Thyristor Bridges, Blowers, Control and LCI panels of ID fan VFD. (Including consumables and T&P items). Cleaning of 22 Nos panel/Shift= One operation. i.e., total operations= 60.
Charges for daily walk down to 11KV, 3.3 KV, 415V switchgears, incomers and bus coupler panels, GRP, DAVR, VFD to check the healthiness of relay, meters and record the electrical parameters. (Including consumables and T&P items)
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_779377.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid