Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹66.4 L+₹43,769.10 (0.66%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹67.9 L+₹1.9 L (2.85%)Rejected-Finance B BLOCK 2 3 RAM BACHAN V B NAGAR PIPE ROAD KURLA W MUMBAI 400070 | MUMBAI SUBURBAN | MAHARASHTRA | 400070 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹70.3 L+₹4.3 L (6.55%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹71.9 L+₹5.9 L (8.98%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
1 May 2023, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
WELCOME MAINTENANCE WITH MISC E/M WORKS IN SAILOR ACCOMMODATIONS AND REPAIR MAINTENANCE AND REPLACEMENT OF STREET/BLDG SECURITY LIGHTS HIGHMAST LIGHTS SEARCH LIGHTS JUNCTION BOXES GARDEN LIGHTS POST TOP LANTERN AND THEIR CABLING WORKS AT RS AREA UNDE
2023_MES_587137_1
8239/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class C and Category b(i)
8 documents required · 8 mandatory
₹1,000
GE NW NAVY NAGAR COLABA MUMBAI
₹1.5 L
Yes
15 Jun 2023
27 Mar 2023
2 May 2023
27 Mar 2023
1 May 2023
17 Apr 2023
27 Mar 2023 - 24 Apr 2023
Amount
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/ points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
Material and labour for point wiring complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm size, ISI mark with all accessories on wall/ceiling/floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin socket outlet, 5 Amps on the same board with other switches
One 3 pin socket outlet, 5 Amps, on the independent board
One bell point controlled by one push button
All as per item No 2.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F in replacement with modular switch, 1 module, single pole one way 6 Amp confirming to IS:3854 and ISI marked complete all as direcred.
S & F in replacement with modular socket 6A, 3 pin, 2 module confirming to IS:1293 : 2019 and ISI marked complete all as direcred.
S & F in replacement with modular switch, 1 module, single pole one way 16 Amp confirming to IS:3854 and ISI marked complete all as direcred.
S & F in replacement with modular socket 6/16A, 3 pin, 2 module confirming to IS:1293 : 2019 and ISI marked complete all as direcred.
S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked.
S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked.
Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed.
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F in replacement with modular PVC Gang box of 12 module, ISI marked for mounting of modular switches and sockets including blank plate for blank module.
All as per Item No- 12.00 above but of modular PVC Gang box, 8 module.
All as per Item No- 12.00 above but of modular PVC Gang box, 6 module.
All as per Item No- 12.00 above but of modular PVC Gang box, 4 module.
All as per Item No- 12.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 12.00 above but of modular PVC Gang box, 1/2 module.
S&F modular white cover plate with frame, 12 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 4 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 1/2 module.
Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab.
All as per Item No-24.00 above but Slim LED integrated batten of 10 Watt 2ft complete.
S&F MCB DB SPN confirming to as per IEC 61439-3 and IP 43, IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls.
Taking out Old U/S and S&F MCB SPN, 32 Amp, 10 KA, 230 Volt.
Taking out Old U/S and S&F MCB, single pole, upto 20 Amp, 10 KA, 230 Volt.
Supply and fixing of MCCB DB VTPN 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB's with provision for 100 Amp 4pole MCCB as incomer and SP/TP MCB's as outgoing complele all as specified and directed.
Supply and fixing of MCCB 100A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu .
Supply and fix MCB TP 63A, 10kA, 415V.
Supply and fix MCB SP 63A, 10kA, 240V.
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified.
Taking out unserviceable exhaust Fan and deposit to MES Store, supply and replacement with exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz, 300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connecting with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified and directed.
Taking out & Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coat of painting and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Rate of petty items to be replace shall be included in quoted rate.
S & F in replacement with cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
S & F in replacement with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as directed.
S & F in replacement with power contactor 3 pole AC, with 240 volt coil, 32 Amp rating conforms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights complete all as directed.
S & F in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm.
S & F in replacement with electric bell ding dong, AC, 230V single pole.
Inspection/ checking of serviceability for Ceiling/Exhaust fan to avoid any accident on site a job shall be done as taking down ceiling fan from its position, checking and replacement of minor unserviceable and minor defective spare parts responsible for any accident (i.e. 'S' hooks, split pin, cotter pins, rubber bush etc) servicing the fan completely after removing of old grease from bearings and compulsury fixing of safety wire (SWR) from fan motor to Ceiling hook incl hanging it to its same location after complete assurence of any defect and connecting with copper conductor multi stranded 3 core wire of size 0.75 sqmm complete all as specified and as directed by Engr-in-Charge.
S & F in replacement with capacitor 2.5Mfd in ceiling fan 1200/1400 mm sweep.
Supply and Fix and replacement of15mm dia MS clamp assembly with Nut, Bolts & rubber bush suitable for down rods and split pins including taking out old one as approved by Engr-in-Charge
M & L for fabrication of fan hook made out of SS rod and fan Hook bend to shape 'S' after taking out old one.
Dismantling LED light fitting of of Make:Bajaj /Crompton/ Phillips/ Havells/ Wipro/Orient/C&S/Polycab/Shakti Henolix of capacity 200 to 400 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items.
Dismantling LED light fitting of of Make:Bajaj/ Crompton/ Phillips/ Havells/ Wipro/Orient/C&S/Polycab/Shakti of capacity 120 to 180 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of of Make:Bajaj /Crompton/ Phillips/ Havells/ Wipro/Orient/C&S/Polycab/Shakti of capacity 70 to 110 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of of Bajaj/ Crompton/ Phillips/ Havells /Wipro/ Orient/C&S/Polycab/Shakti of capacity 30 to 60 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 3.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site. d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
Supply only the following spares suitable for LED street/Flood light fittings of make: Bajaj/Crompton/Phillips/Havells/Wipro/Orient/C&S/Polycab/Shakti
Electronic driver suitable for outdoor LED fitting of capacity 200 to 400 Watt.
Electronic driver suitable for outdoor LED fitting of capacity 120 to 180 Watt.
Electronic driver suitable for outdoor LED fitting of capacity 70 to 110 Watt.
Electronic driver suitable for outdoor LED fitting of capacity 30 to 60 Watt.
Surge protection device compatible with industrial & outdoor LED fitting of capacity 5 KV complete all as specified and as directed.
Surge protection device compatible with industrial & outdoor LED fitting of capacity 10 KV complete all as specified and as directed.
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 45 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 9000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 25000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 250 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 35000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 350 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 40000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 400 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed.
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9. complete all as specified and direrected by Engr in Charge.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
Supply, laying and commissioning, testing armoured heavy duty electric cable with copper conductor, 1100 volts grade of size 4 sqmm 4 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles/bottle lugs and taking out old u/s damaged cables.
All as per item No- 63.00 here in before but of size 2.5 sqmm 3 core including taking out old u/s damaged cables.
All as per item No- 63.00 here in before but of size 1.5 sqmm 2 core including taking out old u/s damaged cables.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
S & F astronomical Timelite distribution board IP-54 with contactor, relay and prewired, 32A, 3 pole, 230 Volt , and Astronomical programmable time switch with backup of 6 years, 28 memory locations, current capacity 16 A with one CO time switches for street light complete.
S & F in repairs analog time switch 3 phase of current capacity 16 Amps incl any type of accessories for fixing of time switch after taking out unserviceable one.
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carrying capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
S & F in repair MCB TPN 32 Amp 230 volt AC complete all as directed.
S & F in repair MCB TPN 63 Amp 230 volt AC complete all as directed.
M&L for Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and GI wire 4 sqmm dia as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to earth wire 4 sqmm by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
S&F loop-in/loop-out box of outer size size 225mmx295mmx122mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm aluminium clamp not less than, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
S&F in repair thermoplastic cable junction water proof boxes of 130x130x77mm, with metric knockouts for cable entry and suitable size of gland for 4 to 10 Sqmm cable out door type with clamp for mounting on pole complete all as specified and as directed.
S&F street light bracket bend to shape made as required of 32/40mm dia 1 mtr long GI pipe light grade fixed to pole/wall with flat iron clamp of size 40x6mm two number with the help of nuts and bolts for fixing of street light fitting including making all electric connection including taking out old one complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of 9/11 mtr long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with white letters/ blackground etc complete all as directed
Repairs to High Mast/mid mast pole motor of Capacity 1.0 HP/0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary rewinding with super enamelled copper wire all as per existing and servicing/greasing of reduction gear box complete all as specified and as directed by Engr-in-Charge.
Decarbonising of the control panel of High mast/Mid mast and including sevicing of parts such as contactors/timers including replacement of pitted lugs,thimbles, control wiring etc complete including painting with a coat of synthetic enamel paint
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
All as per above item No.80 above but exceeding depth 1.5 mtr and n exceeding 3 mtrs.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
Removing excavated material from the site of work and transporting out of Station/site of work suitable to the contractor all as specified.
Supply, filling, spreading levelling and well ramming the river sand around cable in trenches for cable cushioning all as specified and directed.
Material and labour for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250x250 mm having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, with and including layer of 50 mm thick natural river sand bed compacted complete as specified and directed.
Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm.
Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces.
Material and labour for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate), for coping and finished surface without using extra cement.
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 50 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables.
All as per Item No-89.00 here in before but of sizes, 35 sqmm, 3.5 core.
All as per Item No-89.00 here in before but of sizes, 25 sqmm, 3.5 core.
All as per Item No-89.00 here in before but of sizes, 16 sqmm, 4 core.
All as per Item No-89.00 here in before but of sizes, 10 sqmm, 4 core.
All as per Item No-89.00 here in before but of sizes, 10 sqmm, 2 core.
M&L for 50mm dia High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface all as specified and directed.
All as per Item No-95.00 here in before but of sizes, 75mm dia
M&L for GI pipe ,light grade 50mm dia for road crossing or in hard standing for protection of cable above or under ground surface including taking out old one all as specified and directed.
All as per Item No-97.00 here in before but of sizes, 80mm dia
S&F manual operated security search light complete with brass body including LED 200 watt lamp with lens, handle for rotation of search light luminous flux 26000, operating temperature 20 deg C to 60 deg C, IP-65 protection, working humidity 5% to 95% RH of range cover 250 Mtr, THD<10%, power factor>0.95, CRI>70, mounting base cap, reflector complete system including taking out U/S complete all as directed.
Supply and fixing of MCCB 100A, 25kA, 4P, 415 V Thermal adjustable – 0.8 to 1In, Magnetic adjustable – 5 to 10In, Ics=100% Icu .
S&F in replacement of 20 watt LED RGB under water light IP68 luminaire, size - 190mmx250mm with stainless steel housing with driver including necessary stand for fixing of fountain light with mounting base including making all electrical connection complete.
All as per item No - 101.00 above but LED RGB under water, 12 watt.
S&F in replacement with LED fasad batten light of 36 watt, 4 feet with RGB wall washer made up of pressure die cast housing with aluminium LED with lense, IP-65, with stand and cover including driver and remote control operated including frame for mounting of light as required and making all electrical connection complete all as directed.
All as per item No - 103.00 above but LED fasad batten light of 2 feet, 18 watt.
Taking out old unsv security light fitting and S&F new bldg security light 60 watt with inbuilt smart motion sensor with with 25% dimmer illuminous in ideal time with all accessories comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 60 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc complete with following specification. (i) housing- epoxy powder coated housing, enclosed with glass cover , LED type- High Power LED ,Light distribution- Bat wing, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95 to 0.98, THD - <10%, Mounting/Fixing- GI Bracket, Ingress Protection - IP-65/66, Sensor type- HF inbuilt integral occupancy/movement sensor, Sensor type – Dusk Dawn sensor mounted on LED PCB, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of motion switches back to default operation, LED life- upto 50,000 Hrs. Surge Protection - 4 to 10 KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM.
Taking out old unsv security light fitting and S&F new bldg security light 72 watt with inbuilt smart motion sensor with with 25% dimmer illuminous in ideal time with all accessories comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 60 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc complete with following specification. (i) housing- epoxy powder coated housing, enclosed with glass cover , LED type- High Power LED ,Light distribution- Bat wing, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95 to 0.98, THD - <10%, Mounting/Fixing- GI Bracket, Ingress Protection - IP-65/66, Sensor type- HF inbuilt integral occupancy/movement sensor, Sensor type – Dusk Dawn sensor mounted on LED PCB, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of motion switches back to default operation, LED life- upto 50,000 Hrs. Surge Protection - 4 to 10 KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM.
Taking out old unsv bldg light fitting and S&F new bldg security light 90 watt with inbuilt smart motion sensor with with 25% dimmer illuminous in ideal time with all accessories comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 9000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 60 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc complete with following specification. (i) housing- epoxy powder coated housing, enclosed with glass cover , LED type- High Power LED ,Light distribution- Bat wing, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95 to 0.98, THD - <10%, Mounting/Fixing- GI Bracket, Ingress Protection - IP-65/66, Sensor type- HF inbuilt integral occupancy/movement sensor, Sensor type – Dusk Dawn sensor mounted on LED PCB, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of motion switches back to default operation, LED life- upto 50,000 Hrs. Surge Protection - 4 to 10 KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM.
S&F Decorative Ornamental Cast iron Pole of height 3 Mtr with base dia of 200mm, bottom-210mmx450mm above the foundation top level fabricated with cast iron embellishment, joints, column sections etc re-inforced internally with a MS pipe inside and inbuilt looping box for incoming and outgoing UG cable. The pole shall have cast iron design for double arm bracket . The pole shall be painted with polyurethane paint of approved colour finish including fixing and grouting to old existing foundation with the help of Nuts, bolts and washer, making all electrical conection to light fitting after taking out old CI pole and necessary PCC work, all as directed.
S&F CI casted two way bracket with centre hub for mounting on 3 mtr deco ornamental pole suitable for fixing LED decorative lantern fitting of 14/15 Watt and making all electrical connection to the light after taking out old U/S.
S&F Post type LED decorative lantern fitting 19"x11" of 14/15 Watt IP 65 with spun aluminium housing and reflector assembly with polycarbonate/Glass cover with protection for optical compartment complete including taking out old U/S.
S&F Decorative Ornamental Cast iron Pole of height upto 2.5 Mtr with base dia of 200mm, bottom-210mmx450mm with cast iron embellishment, joints, column sections with cross cutting groves etc cast iron design with cast iron designed double arm bracket for lantern. The pole shall be painted with polyurethane paint of approved colour finish including fixing and grouting on round PCC plateform of 60cm above ground level with the help of Nuts, bolts and washer, making all electrical conection to light fitting after taking out old CI pole and necessary PCC work, all as directed.
S&F Decorative Alluminium casted, powder coated lantern of size 21"x9" for decorative ornamental poles with holder for LED Lamp and with 6 Nos of Polycarbonate/frosted Glass for optical compartment as per sample and reconnecting all electrical connection to light complete including taking out old U/S.
S&F in replacement with new LED pin type lamp of 14 watt warm white after opening of post type lantern fitting from deco pole and checking of all electrical connection and refixing the lantern cover on its existing arm of deco pole.
S&F Aluminium casted pole of 1.5 Mtr long, powder coated with foundation bracket and holder for mounting of decorative Garden light including necessary PCC plateform for grouting pole and reconnecting all electrical connection to light complete including taking out old U/S.
Supply and fixing Frosted Glass suitable for optical compartment of Decorative light fittings (As per sample) approved by Engr-in-Charge.
Supply and fixing LED based bollard light 9 watt with MS pipe housing with glare free PMMA diffuser,IP-65 complete with necessary PCC foundation and PCC block of 60cm height above ground including taking out old, U/S complete all as directed.
S&F Integral decorative LED 45 Watts Post Top with opal acrylic with IP65 Protection mounted on 1.5 Mtr GI pole complete with necessary PCC foundation and PCC block of 60cm height above ground including taking out old, U/S complete all as directed.
All as per item No - 117.00 above but LED Post Top lantern 20 watt.
M&L for re-saddling of conduits with wiring on external wall surfaces of buildings for building security lights with provision of new PVC/MS clamp, screws and plugs etc as required at site complete all as specified and directed by Engr-in-Charge. Note : New PVC conduits and wiring if required at site shall be measured and paid separately under relevant items of the schedule.
NOEL ENGINEERS
Genius Construction Co.
S S ENTERPRISES
shubham construction
AGRAWAL ASSOCIATES
SHREE JAGDISH FURNITURE CO.
NARMARAJ ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .